We present the design of micro-helix metamaterial supporting high sound absorption characteristic by 3D printing. The sample structure which is fabricated out of polylactide (PLA) material, many micro-helix are arra...We present the design of micro-helix metamaterial supporting high sound absorption characteristic by 3D printing. The sample structure which is fabricated out of polylactide (PLA) material, many micro-helix are arranged by periodic arrays on XY plane. Experiment measurement results show that different geometrical dimensions of helix vestibule and cavity depth have a great effect on sound absorption coefficient. Physical mechanism depends on the friction and viscosity between the air and the helix vestibule. This work shows great potential of micro-structure metamaterial in noise control applications require light weight and large rigid of sound absorption.展开更多
Direct-comb spectroscopy techniques uses optical frequency combs(OFCs)as spectroscopic light source.They deliver high sensitivity,high frequency resolution and precision in a broad spectral range.Due to these features...Direct-comb spectroscopy techniques uses optical frequency combs(OFCs)as spectroscopic light source.They deliver high sensitivity,high frequency resolution and precision in a broad spectral range.Due to these features,the field has burgeoned in recent years.In this work we constructed an OFC-based cavity-enhanced Fourier-transform spectrometer in the nearinfrared region and used it for a line-shape study of rovibrational transitions of CO perturbed by Ar.The highly sensitive measurements spanned the wavenumber range from 6270 cm^-1 to 6410 cm^-1,which covered both P and R branch of the second overtone band of CO.The spectrometer delivers high-resolution surpassing the Fourier-transform resolution limit determined by interferogram length,successfully removing ringing and broadening effects caused by instrumental line shape function.The instrumental-line-shape-free method and high signal-to-noise ratio in the measurement allowed us to observe collisional effects beyond those described by the Voigt profile.We retrieved collisional line-shape parameters by fitting the speed-dependent Voigt profile and found good agreement with the values given by precise cavity ring-down spectroscopy measurements that used a continuous-wave laser referenced to a stabilized OFC.The results demonstrate that OFC-based cavity-enhanced Fouriertransform spectroscopy is a strong tool for accurate line-shape studies that will be crucial for future spectral databases.展开更多
基金supported by the National Natural Science Foundation of China (11704314 and 11474230)the Fundamental Research Funds for the Central Universities (3102016QD056) for financial support
文摘We present the design of micro-helix metamaterial supporting high sound absorption characteristic by 3D printing. The sample structure which is fabricated out of polylactide (PLA) material, many micro-helix are arranged by periodic arrays on XY plane. Experiment measurement results show that different geometrical dimensions of helix vestibule and cavity depth have a great effect on sound absorption coefficient. Physical mechanism depends on the friction and viscosity between the air and the helix vestibule. This work shows great potential of micro-structure metamaterial in noise control applications require light weight and large rigid of sound absorption.
文摘Direct-comb spectroscopy techniques uses optical frequency combs(OFCs)as spectroscopic light source.They deliver high sensitivity,high frequency resolution and precision in a broad spectral range.Due to these features,the field has burgeoned in recent years.In this work we constructed an OFC-based cavity-enhanced Fourier-transform spectrometer in the nearinfrared region and used it for a line-shape study of rovibrational transitions of CO perturbed by Ar.The highly sensitive measurements spanned the wavenumber range from 6270 cm^-1 to 6410 cm^-1,which covered both P and R branch of the second overtone band of CO.The spectrometer delivers high-resolution surpassing the Fourier-transform resolution limit determined by interferogram length,successfully removing ringing and broadening effects caused by instrumental line shape function.The instrumental-line-shape-free method and high signal-to-noise ratio in the measurement allowed us to observe collisional effects beyond those described by the Voigt profile.We retrieved collisional line-shape parameters by fitting the speed-dependent Voigt profile and found good agreement with the values given by precise cavity ring-down spectroscopy measurements that used a continuous-wave laser referenced to a stabilized OFC.The results demonstrate that OFC-based cavity-enhanced Fouriertransform spectroscopy is a strong tool for accurate line-shape studies that will be crucial for future spectral databases.