期刊文献+
共找到446篇文章
< 1 2 23 >
每页显示 20 50 100
Stepped-up development of accelerator mass spectrometry method for the detection of ^(60)Fe with the HI-13 tandem accelerator
1
作者 Yang Zhang Sheng-Quan Yan +36 位作者 Ming He Qing-Zhang Zhao Wen-Hui Zhang Chao-Xin Kan Jian-Ming Zhou Kang-Ning Li Xiao-Fei Wang Jian-Cheng Liu Zhao-Hua Peng Zhuo Liang Ai-Ling Li Jian Zheng Qi-Wen Fan Yun-Ju Li You-Bao Wang Zhi-Hong Li Yang-Ping Shen Ding Nan Wei Nan Yu-Qiang Zhang Jia-Ying-Hao Li Jun-Wen Tian Jiang-Lin Hou Chang-Xin Guo Zhi-Cheng Zhang Ming-Hao Zhu Yu-Wen Chen Yu-Chen Jiang Tao Tian Jin-Long Ma Yi-Hui Liu Jing-Yu Dong Run-Long Liu Mei-Yue-Nan Ma Yong-Shou Chen Wei-Ping Liu Bing Guo 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期136-143,共8页
The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides... The Moon provides a unique environment for investigating nearby astrophysical events such as supernovae.Lunar samples retain valuable information from these events,via detectable long-lived“fingerprint”radionuclides such as^(60)Fe.In this work,we stepped up the development of an accelerator mass spectrometry(AMS)method for detecting^(60)Fe using the HI-13tandem accelerator at the China Institute of Atomic Energy(CIAE).Since interferences could not be sufficiently removed solely with the existing magnetic systems of the tandem accelerator and the following Q3D magnetic spectrograph,a Wien filter with a maximum voltage of±60 kV and a maximum magnetic field of 0.3 T was installed after the accelerator magnetic systems to lower the detection background for the low abundance nuclide^(60)Fe.A 1μm thick Si_(3)N_(4) foil was installed in front of the Q3D as an energy degrader.For particle detection,a multi-anode gas ionization chamber was mounted at the center of the focal plane of the spectrograph.Finally,an^(60)Fe sample with an abundance of 1.125×10^(-10)was used to test the new AMS system.These results indicate that^(60)Fe can be clearly distinguished from the isobar^(60)Ni.The sensitivity was assessed to be better than 4.3×10^(-14)based on blank sample measurements lasting 5.8 h,and the sensitivity could,in principle,be expected to be approximately 2.5×10^(-15)when the data were accumulated for 100 h,which is feasible for future lunar sample measurements because the main contaminants were sufficiently separated. 展开更多
关键词 accelerator mass spectrometry Wien filter Isobar separation SUPERNOVAE Chang'e-5 lunar samples
下载PDF
Simulation of experimental spectra for medium-heavy nuclides in accelerator mass spectrometry 被引量:1
2
作者 WANG Hui-Juan GUAN Yong-Jin +6 位作者 HE Ming RUAN Xiang-Dong DONG Ke-Jun LI Guo-Qiang Wu Shao-Yong WU Wei-Ming JIANG Shan 《Nuclear Science and Techniques》 SCIE CAS CSCD 2005年第5期273-277,共5页
Some interferences are often encountered in accelerator mass spectrometry (AMS) measurements, espe-cially for medium-heavy nuclide measurement. It is difficult for online discrimination of the nuclide of interest from... Some interferences are often encountered in accelerator mass spectrometry (AMS) measurements, espe-cially for medium-heavy nuclide measurement. It is difficult for online discrimination of the nuclide of interest from the interfering ones. In order to solve this problem, we developed a method to simulate the experimental spectra of medium-heavy nuclides in AMS measurements. The results obtained from this method are in good agreement with experimental values. 展开更多
关键词 核素 加速器 光谱分析 ams 灵敏度
下载PDF
A DATA ACQUISITION SYSTEM FOR ACCELERATOR MASS SPECTROMETRY
3
作者 张如菊 刘洪涛 +1 位作者 郭之虞 李坤 《Nuclear Science and Techniques》 SCIE CAS CSCD 1990年第3期149-155,共7页
A single and dual parameter data acquisition, ion beam measurements and control system for accelerator mass spectrometry is described. The system hardware has been constructed with the advantage of the lower cost and ... A single and dual parameter data acquisition, ion beam measurements and control system for accelerator mass spectrometry is described. The system hardware has been constructed with the advantage of the lower cost and higher reliability. It is provided with varieties of functions such as selecting acquisition mode carrying out the multiple display, analyzing data and especially viewing isometric spectrum at different directions. It can also be used for ordinary nuclear spectrum system. 展开更多
关键词 accelerator mass spectrometry (ams) Single and dual parameter DATA ACQUISITION Nuclear spectrum ISOMETRIC display DATA analysis
下载PDF
Studies of Al metabolism in animal by accelerator mass spectrometry
4
作者 WangNa-Xiu ZhuHan-Min 《Nuclear Science and Techniques》 SCIE CAS CSCD 1997年第4期249-250,共2页
StudiesofAlmetabolisminanimalbyaceleratormasspectrometryWangNaXiu,ZhouWeiNan,LiuLianFan,ChengXiaoWu,ZhuJinHu... StudiesofAlmetabolisminanimalbyaceleratormasspectrometryWangNaXiu,ZhouWeiNan,LiuLianFan,ChengXiaoWu,ZhuJinHua,QiuHuiYu... 展开更多
关键词 ^26Al 新陈代谢 加速器质量光谱测定
下载PDF
Measurement of the natural ^(36)Cl and ^(236)U in uranium mineral with accelerator mass spectrometry
5
作者 WANG Xianggao JIANG Shan +2 位作者 HE Ming DONG Kejun GUAN Yongjing 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第2期25-30,共6页
The concentration of the natural ultra-trace radionuclides CI and U in the uranium depended on the neutron flux.In this article,a method for measuring 36C1 and 236U in the same uranium mineral with accelerator mass sp... The concentration of the natural ultra-trace radionuclides CI and U in the uranium depended on the neutron flux.In this article,a method for measuring 36C1 and 236U in the same uranium mineral with accelerator mass spectrometry was developed in China Institute of Atomic Energy,providing a protocol of the potential application of 236U in uranium mining,environmental,and geological research.The two samples were from Guangxi and Shanxi province,China,and their ratios 36Cl/C1 and 236U/238U were measured.More experimental data conduced to understand the natural nuclides in the uranium mineral.We plan to conduct more efforts on the research. 展开更多
关键词 铀矿开采 加速器质谱 质谱测量 中国原子能科学研究院 自然 天然放射性核素 中子通量 实验数据
下载PDF
^(36)Cl-AMS measurements with 3-MV tandem accelerator
6
作者 WANG Huijuan GUAN Yongjing +2 位作者 ZHANG Wei JIANG Shan Ming He 《Nuclear Science and Techniques》 SCIE CAS CSCD 2013年第1期22-25,共4页
36Cl is one of the most interesting nuclides in accelerator mass spectrometry (AMS) measurements. The application of 36Cl has been widely applied in various fields. All most all of 36Cl AMS measurements at natural iso... 36Cl is one of the most interesting nuclides in accelerator mass spectrometry (AMS) measurements. The application of 36Cl has been widely applied in various fields. All most all of 36Cl AMS measurements at natural isotopic concentrations have yet been performed at tandem accelerator with 5 MV or higher terminal voltage. The measure improvement of 36Cl and other medium heavy isotopes performed at 3 MV in AMS facilities is one of the hottest topics in AMS measurements. In order to increase the suppression factor of 36S, the energy loss straggling and angular straggling of 36Cl and 36S ions in various counter gases (P10, isobutane and propane) were investigated. Some groundwater samples were measured with energy of 32 MeV, and the results were in good agreement with the result obtained with ion energy of 72 MeV. The results indicate that the approximate detection limit of 36Cl in 3 MV AMS facility is 36Cl/Cl=1×10-14 , and the uncertainty is 30% when the sample with isotopic ration 36Cl/Cl≈10-13. 展开更多
关键词 串列加速器 ams 测量 天然同位素 能量损失 离子能量 加速器质谱 抑制因子
下载PDF
基于AMS的^(14)C法对生物质与煤混燃掺烧比测定的研究进展
7
作者 王睿思 孙堂磊 +2 位作者 杨延涛 刘鹏 雷廷宙 《林产工业》 北大核心 2023年第10期33-39,共7页
生物质与煤耦合燃烧不仅可以提高生物质资源利用率,还可以达到减排效果,以符合碳交易市场要求。将生物质与煤混燃技术广泛应用于发电厂,需要对生物质掺混比进行高精度测定。然而,当前工业技术测量的速度和精度还有待提高。基于加速器质... 生物质与煤耦合燃烧不仅可以提高生物质资源利用率,还可以达到减排效果,以符合碳交易市场要求。将生物质与煤混燃技术广泛应用于发电厂,需要对生物质掺混比进行高精度测定。然而,当前工业技术测量的速度和精度还有待提高。基于加速器质谱(AMS)的^(14)C检测法能够更准确迅速地进行^(14)C含量的测定,从而得出生物质掺混比例。本文阐述了生物质掺混比的高精度快速测定方法,并从采样方法、^(14)C含量测定、掺烧比计算模型、误差分析等方面对基于AMS的^(14)C检测方法进行了分析,并提出了测量方法的改进建议和展望,以期对生物质与煤耦合燃烧输入侧掺混比精确快速测定提供科学参考和建议。 展开更多
关键词 混燃技术 生物质与煤掺混比 ^(14)C检测 加速器质谱 研究进展
下载PDF
真空冻干/快速溶剂萃取-气相色谱-质谱法测定土壤中35种不同种类半挥发性有机物
8
作者 邓云江 邓昭祥 +4 位作者 韩洁莲 杨健 钟蕾 杜作灵 张安丰 《分析科学学报》 CAS CSCD 北大核心 2024年第2期190-198,共9页
建立了真空冻干/快速溶剂萃取-气相色谱-质谱法(GC-MS)测定土壤中35种不同种类半挥发性有机物(SVOCs)的方法。样品经真空冷冻脱水、快速溶剂萃取、旋转蒸发浓缩以及固相萃取SPE小柱净化后,氮吹定容,采用GC-MS上机测定。结果表明:土壤中3... 建立了真空冻干/快速溶剂萃取-气相色谱-质谱法(GC-MS)测定土壤中35种不同种类半挥发性有机物(SVOCs)的方法。样品经真空冷冻脱水、快速溶剂萃取、旋转蒸发浓缩以及固相萃取SPE小柱净化后,氮吹定容,采用GC-MS上机测定。结果表明:土壤中35种SVOCs在10~1000μg/L范围内线性相关系数r^(2)≥0.991,方法检出限为0.034~0.40μg/kg,方法定量限为0.14~1.20μg/kg;以空白样品为基体进行加标回收实验,所得加标回收率为71.2%~113%,相对标准偏差(RSDs,n=7)为0.38%~13.3%,替代物荧蒽-D 10回收率为84.0%~92.5%;经实际样品检测验证,该方法灵敏、快速、准确可靠,适用于土壤中35种不同种类SVOCs的分析检测。 展开更多
关键词 土壤 真空冻干 半挥发性有机物 快速溶剂萃取 气相色谱-质谱
下载PDF
大气^(14)CO_(2)的加速器质谱分析技术研究进展
9
作者 崔晓宇 邢冠华 +2 位作者 王超 于建钊 袁懋 《中国环境监测》 CAS CSCD 北大核心 2024年第2期41-52,共12页
利用加速器质谱技术测定大气^(14)CO_(2)以示踪大气化石源CO_(2)成为当前减污降碳工作的热点。该文从加速器质谱14 C分析基础出发,系统介绍了加速器质谱的工作原理、大气样品的采集及纯化、石墨化样品的制备和测定,阐述了大气碳监测领域... 利用加速器质谱技术测定大气^(14)CO_(2)以示踪大气化石源CO_(2)成为当前减污降碳工作的热点。该文从加速器质谱14 C分析基础出发,系统介绍了加速器质谱的工作原理、大气样品的采集及纯化、石墨化样品的制备和测定,阐述了大气碳监测领域^(14)CO_(2)测试的研究进展。随着加速器质谱技术的不断发展,大气^(14)CO_(2)的研究将会更加广泛和深入,有助于进一步认识大气化石源CO_(2)的来源,更有针对性地开展减污降碳工作。未来应统一制定^(14)CO_(2)监测方法标准,规范操作流程和质控手段,完善实验仪器配套设施,加快提升监测能力和水平。 展开更多
关键词 加速器质谱 ^(14)CO_(2)分析技术 研究进展
下载PDF
低能核反应产物^(26)Al的AMS测量方法研究 被引量:4
10
作者 郑元丰 阮向东 +4 位作者 何明 武绍勇 管永精 董克君 姜山 《质谱学报》 EI CAS CSCD 2003年第1期295-297,共3页
分别选用 Ti N、Al2 O3和 2 6 Al7+为靶材料、载体和被测离子 ,用加速器质谱计 (AMS)分别测量了 O、N重离子低能熔合反应产物和标准样品的 2 6 Al,研究结果显示测量方法是准确。
关键词 低能核反应产物 ams 测量 加速器质谱计 重离子 铝26
下载PDF
一台用于AMS的鉴别同量异位素的气体电离室 被引量:9
11
作者 姜山 蒋崧生 +1 位作者 王洵 马铁军 《原子能科学技术》 EI CAS CSCD 北大核心 1991年第3期40-44,共5页
文章描述一台用于加速器质谱计(AMS)的鉴别同量异位素的气体电离室,它由三个分离的阳极、一个栅极和阴极组成。利用这台电离室,在加速器上进行了^(36)Cl的测定。它有效地排除了^(36)S等本底的干扰。
关键词 气体电离室 加速器 质谱计
下载PDF
黄土样品的BeO制备及AMS测量 被引量:5
12
作者 武振坤 周卫健 +4 位作者 刘敏 余华贵 潘彩文 孔祥辉 卢雪峰 《核技术》 CAS CSCD 北大核心 2008年第6期427-432,共6页
采用常规方法提取黄土-古土壤样品中的10Be,制备BeO样品时,无法有效降低样品中B含量,导致在10BeAMS测量中本底值偏高。本文对BeO制备方法进行了优化。新的制备流程改进了阳离子树脂交换、Be(OH)2转化为BeO的灼烧方式以及实验所采用的仪... 采用常规方法提取黄土-古土壤样品中的10Be,制备BeO样品时,无法有效降低样品中B含量,导致在10BeAMS测量中本底值偏高。本文对BeO制备方法进行了优化。新的制备流程改进了阳离子树脂交换、Be(OH)2转化为BeO的灼烧方式以及实验所采用的仪器设备。在西安加速器质谱仪(Xi’an-AMS)上测试结果表明,采用该化学流程制备的BeO样品化学本底可以达到2.04×10-14。本文还介绍了Xi’an-AMS测量10Be的方法与测量结果。 展开更多
关键词 黄土 BEO 加速器质谱(ams)
下载PDF
用^(41)Ca-AMS法测定谷氨酸毒性对PC12细胞外钙内流的影响 被引量:4
13
作者 袁媛 李世红 +4 位作者 张东正 何明 董克君 张根发 姜山 《核技术》 EI CAS CSCD 北大核心 2006年第11期821-825,共5页
本工作用41Ca示踪PC12细胞,以CaF2作为最终测量样品,用加速器质谱计(全称AMS)测量41Ca。从谷氨酸毒性对PC12细胞的时间效应,MK-801对PC12细胞受体门控钙通道(全称ROC)阻断效应两方面进行分析,以激光扫描共聚焦显微镜的检测结果作为参照... 本工作用41Ca示踪PC12细胞,以CaF2作为最终测量样品,用加速器质谱计(全称AMS)测量41Ca。从谷氨酸毒性对PC12细胞的时间效应,MK-801对PC12细胞受体门控钙通道(全称ROC)阻断效应两方面进行分析,以激光扫描共聚焦显微镜的检测结果作为参照,结果表明41Ca的加速器质谱(AMS)测量方法能有效地检测到在不同情况下谷氨酸引起PC12细胞中外钙内流的情况。综合两种方法推测在谷氨酸引起的钙超载中,NMDAR介导的外钙内流起了重要作用。 展开更多
关键词 ^41Ca 加速器质谱计 激光扫描共聚焦显微镜 PC12细胞 谷氨酸 MK-801
下载PDF
^(14)C-AMS在生物医学研究中的应用 被引量:4
14
作者 孙红芳 王海芳 刘元方 《核技术》 CAS CSCD 北大核心 2001年第9期748-754,共7页
加速器质谱 (AMS)法是一种超灵敏的核分析技术 ,可用于体内14 C标记的痕量分子的示踪以及评估致癌性的生物标志物的检测。本文综述了14 C
关键词 加速器质谱法 DNA加合物 蛋白质加合物 生物标志物 外源物 示踪 生物标记物 石炭14 生物医学研究
下载PDF
AMS测量中同量异位素的鉴别方法 被引量:4
15
作者 管永精 何明 +3 位作者 阮向东 董克君 吴伟明 姜山 《原子核物理评论》 CAS CSCD 北大核心 2003年第4期290-294,共5页
在加速器质谱测量中,存在同位素和同量异位素的干扰.排除同位素的干扰是开展超微量核素分析的重要课题之一.主要介绍了加速器质谱测量中同量异位素的几种鉴别、排除方法,以及这些方法的原理、发展及应用.
关键词 加速器质谱 同量异位素 离子鉴别 望远镜法 充气磁谱仪法 Bragg谱仪探测 充气飞行时间法
下载PDF
环境中^(129)I的AMS方法测定 被引量:5
16
作者 蒋崧生 何明 +2 位作者 谢运棉 姜山 武绍勇 《核技术》 EI CAS CSCD 北大核心 2000年第1期43-46,共4页
基于中国原子能科学研究院的串列静电加速器在我国建立了超高灵敏加速器质谱技术(AMS)测定129I核素的方法,对我国可能受到人工放射性影响的环境中的129I进行了初步研究。结果表明,该地区129I含量比一般地区的含量明... 基于中国原子能科学研究院的串列静电加速器在我国建立了超高灵敏加速器质谱技术(AMS)测定129I核素的方法,对我国可能受到人工放射性影响的环境中的129I进行了初步研究。结果表明,该地区129I含量比一般地区的含量明显偏高,其含量大小同取样地点相关。数据充分显示我国环境中129I核素含量也在增加。对于环境监测以及对于129I作为示踪剂在地球科学的应用而言,建立我国环境中的129I数据库是十分重要的。 展开更多
关键词 加速器质谱技术 碘核素 环境科学
下载PDF
加速器质谱(AMS)测量中^(41)Ca标准样品的制备 被引量:2
17
作者 武绍勇 姜山 +3 位作者 董克君 何明 许国基 游曲波 《质谱学报》 EI CAS CSCD 2002年第4期248-251,共4页
简要介绍加速器质谱 ( MAS)测量样品采用 Ca H2 以排除 4 1K的干扰。其制备主要包括两步 :首先是Ca O与过量的 Zr粉混合 ,在高温下还原出金属钙 ,然后金属钙与氢气在密闭容器中加热反应生成 Ca H2 。从金属钙到 Ca H2 的转换效率大于 9... 简要介绍加速器质谱 ( MAS)测量样品采用 Ca H2 以排除 4 1K的干扰。其制备主要包括两步 :首先是Ca O与过量的 Zr粉混合 ,在高温下还原出金属钙 ,然后金属钙与氢气在密闭容器中加热反应生成 Ca H2 。从金属钙到 Ca H2 的转换效率大于 90 %。 展开更多
关键词 加速器质谱 标准样品 制备 质谱学 氢化钙 钙41 同位素 人工合成
下载PDF
AMS-BeO制备技术及^(10)Be的测定 被引量:4
18
作者 易惟熙 沈承德 +4 位作者 欧阳自远 胡妙君 刘联璠 周慰囡 章晖 《核技术》 CAS CSCD 北大核心 1991年第1期33-35,共3页
报道了用于AMS^(10)Be分析的BeO的制备流程,用EDTA作掩蔽剂,在不同pH值下沉淀不同的离子,从而达到纯化Be的目的,再在高温灼烧下转换成BeO。目前制备的样品有空白、陨石、沉积物及锰结核。用本流程制得的空白的^(10)Be/~9Be比值为1.1... 报道了用于AMS^(10)Be分析的BeO的制备流程,用EDTA作掩蔽剂,在不同pH值下沉淀不同的离子,从而达到纯化Be的目的,再在高温灼烧下转换成BeO。目前制备的样品有空白、陨石、沉积物及锰结核。用本流程制得的空白的^(10)Be/~9Be比值为1.1×10^(-13),略高于Zürich ETH及Pennsylvania实验室,而低于其他二实验室,显示了我们制得的BeO中^(10)B干扰小,因而制样流程是成功的。 展开更多
关键词 加速器质谱 ^10BE BEO
下载PDF
加速器质谱(AMS)测量中充气飞行时间探测方法研究 被引量:2
19
作者 管永精 阮向东 +4 位作者 郑元丰 董克君 武绍勇 何明 姜山 《质谱学报》 EI CAS CSCD 2003年第2期381-383,共3页
为了提高加速器质谱 (AMS)测量中同量异位素的分辨能力 ,设计了一种新型探测器即充气飞行时间探测器。主要探讨了充气飞行时间谱仪 (GF-TOF)的原理、结构和测试方法 ,给出了用α源调试的结果。通过增加离子的能量并合理选择气体和飞行... 为了提高加速器质谱 (AMS)测量中同量异位素的分辨能力 ,设计了一种新型探测器即充气飞行时间探测器。主要探讨了充气飞行时间谱仪 (GF-TOF)的原理、结构和测试方法 ,给出了用α源调试的结果。通过增加离子的能量并合理选择气体和飞行距离提高 展开更多
关键词 加速器质谱 ams 测量 充气飞行时间探测器 充气飞行时间谱仪 原理 结构 同量异位索 分辨能力
下载PDF
加速器质谱(AMS)测量中的粒子鉴别探测器 被引量:2
20
作者 阮向东 王慧娟 +3 位作者 管永精 李国强 何明 姜山 《核电子学与探测技术》 CAS CSCD 北大核心 2005年第1期8-12,共5页
描述了中国原子能科学研究院AMS测量中使用的飞行时间探测器、多阳极电离室、Bragg探测器、入射离子X射线探测器以及充气飞行时间探测器。通过它们可以获得粒子的飞行时间、部分能量和总能量,从而达到粒子鉴别的目的。介绍了采用这些探... 描述了中国原子能科学研究院AMS测量中使用的飞行时间探测器、多阳极电离室、Bragg探测器、入射离子X射线探测器以及充气飞行时间探测器。通过它们可以获得粒子的飞行时间、部分能量和总能量,从而达到粒子鉴别的目的。介绍了采用这些探测器在HI-13串列AMS系统上做的相关工作以及取得成果。 展开更多
关键词 粒子鉴别 总能量 加速器质谱 飞行时间 ams X射线探测器 离子 电离室 充气 阳极
下载PDF
上一页 1 2 23 下一页 到第
使用帮助 返回顶部