This paper dynamically captures the out-of-step center for a bulk power system based on measurement information.First,the position characteristics of the out-of-step center are discussed from the perspective of triang...This paper dynamically captures the out-of-step center for a bulk power system based on measurement information.First,the position characteristics of the out-of-step center are discussed from the perspective of triangular geometry under different potential and uniform impedance distributions based on a two-machine system.The correlation between the out-of-step center and the oscillation center is analyzed.Second,combined with analytical geometry,it is inferred that the distribution characteristics of the out-of-step center voltage vector ends are a circle or a straight line,and the position of the out-of-step center corresponds to the intersection between the voltage drop of the line and the distribution characteristics;then,the accurate location of the out-of-step center and the determination of the appearance moment is realized.Finally,a dynamic equivalence method for a power grid is proposed based on the electrical parameters of the transmission line,and an alternative iterative correction of equivalent parameters is carried out by trajectory sensitivity,which provides a new way for capturing the out-ofstep center dynamically in a multimachine system.The proposed method is validated using a three-machine system,the IEEE-39 system and the Northwest China Power Grid,and shows potential for online applications.展开更多
基金supported in part by State Grid Corporation of China(5100-202055293A-0-0-00)。
文摘This paper dynamically captures the out-of-step center for a bulk power system based on measurement information.First,the position characteristics of the out-of-step center are discussed from the perspective of triangular geometry under different potential and uniform impedance distributions based on a two-machine system.The correlation between the out-of-step center and the oscillation center is analyzed.Second,combined with analytical geometry,it is inferred that the distribution characteristics of the out-of-step center voltage vector ends are a circle or a straight line,and the position of the out-of-step center corresponds to the intersection between the voltage drop of the line and the distribution characteristics;then,the accurate location of the out-of-step center and the determination of the appearance moment is realized.Finally,a dynamic equivalence method for a power grid is proposed based on the electrical parameters of the transmission line,and an alternative iterative correction of equivalent parameters is carried out by trajectory sensitivity,which provides a new way for capturing the out-ofstep center dynamically in a multimachine system.The proposed method is validated using a three-machine system,the IEEE-39 system and the Northwest China Power Grid,and shows potential for online applications.