期刊文献+
共找到152,254篇文章
< 1 2 250 >
每页显示 20 50 100
Management of geriatric acetabular fractures:Contemporary treatment strategies
1
作者 Theodoros Tosounidis Byron Chalidis 《World Journal of Clinical Cases》 SCIE 2024年第13期2151-2156,共6页
Acetabular fractures in the geriatric population are typically low-energy fractures resulting from a fall from standing height.Compromised bone quality in the elderly,as well as this population’s concomitant medical ... Acetabular fractures in the geriatric population are typically low-energy fractures resulting from a fall from standing height.Compromised bone quality in the elderly,as well as this population’s concomitant medical comorbidities,render the management of such fractures challenging and controversial.Non-operative management remains the mainstay of treatment,although such a choice is associated with numerous and serious complications related to both the hip joint as well as the general condition of the patient.On the other hand,operatively treating acetabular fractures(e.g.,with osteosynthesis or total hip arthroplasty)is gaining popularity.Osteosynthesis can be performed with open reduction and internal fixation or with minimally invasive techniques.Total hip arthroplasty could be performed either in the acute phase combined with osteosynthesis or as a delayed procedure after a period of non-operative management or after failed osteosynthesis of the acetabulum.Regardless of the implemented treatment,orthogeriatric co-management is considered extremely crucial,and it is currently one of the pillars of a successful outcome after an acetabular fracture. 展开更多
关键词 acetabular fractures Geriatric fractures Fracture fixation Total hip arthroplasty MORTALITY MORBIDITY
下载PDF
The analysis of relevant risk factors of traumatic arthritis resulting from the surgery of acetabular fractures
2
作者 黄金城 《外科研究与新技术》 2011年第2期116-116,共1页
Objective To explore the relevant risk factors of tramatic arthritis resulting from the surgery of acetabular fractures. Methods From January 2000 to January 2009,88 patients aged from 20 to 60 years old with acetabul... Objective To explore the relevant risk factors of tramatic arthritis resulting from the surgery of acetabular fractures. Methods From January 2000 to January 2009,88 patients aged from 20 to 60 years old with acetabular fractures 展开更多
关键词 The analysis of relevant risk factors of traumatic arthritis resulting from the surgery of acetabular fractures
下载PDF
Fix and replace:An emerging paradigm for treating acetabular fractures in older patients 被引量:2
3
作者 Elizabeth K Tissingh Abigail Johnson +1 位作者 Joseph M Queally Andrew D Carrothers 《World Journal of Orthopedics》 2017年第3期218-220,共3页
Acetabular fractures in older patients are challenging to manage.The "fix and replace" construct may present a new paradigm for the management of these injuries.We present the current challenge of acetabular... Acetabular fractures in older patients are challenging to manage.The "fix and replace" construct may present a new paradigm for the management of these injuries.We present the current challenge of acetabular fractures in older patients.We present this in the context of the current literature.This invited editorial presents early results from our centre and the ongoing challenges are discussed. 展开更多
关键词 acetabular fracture Total HIP ARTHROPLASTY TRAUMA
下载PDF
Open Reduction by Fenestration to the Ilium for Central Acetabular Depression Fractures: A Case Report and Operative Technique
4
作者 Kazushige Yoshida Masaaki Maruyama +2 位作者 Kentaro Kasama Hiroyuki Hashidate Kazumi Kitagawa 《Open Journal of Orthopedics》 2016年第8期221-226,共6页
Aim: The aim was to report a fenestration technique for gap reduction of acetabular depression fractures. Case presentation: A 76-year-old man suffered from severe left leg pain. The computed tomography scanning showe... Aim: The aim was to report a fenestration technique for gap reduction of acetabular depression fractures. Case presentation: A 76-year-old man suffered from severe left leg pain. The computed tomography scanning showed a displaced acetabular depression fracture, including a third fracture fragment in the center of the acetabular weight-bearing area. We performed a fenestration technique to fenestrate the outer plate of ilium to push down the dislocated fragment of the fracture. The patient was pain-free with good functional outcome of the hip joint at three years after operation. Conclusion: The fenestration technique is useful for displaced acetabular depression fractures. We performed open reduction in this particular case, but the technique may be done less invasively with the use of hip arthroscopy. 展开更多
关键词 Hip Fracture FENESTRATION acetabular Fracture
下载PDF
Total hip arthroplastyvs. osteosynthesis in acute complex acetabular fractures in the elderly:Evaluation of surgical management and outcomes 被引量:3
5
作者 Serafino Carta Gabriele Falzarano +7 位作者 Giuseppe Rollo Predrag Grubor Mattia Fortina Luigi Meccariello Antonio Medici Alberto Riva Luca Sampieri Paolo Ferrata 《Journal of Acute Disease》 2017年第1期12-17,共6页
Objective: To retrospectively evaluate the open reduction internal fixation and total hip arthroplasty directions, results and complications associated with internal fixation in managing these fractures. <br> Me... Objective: To retrospectively evaluate the open reduction internal fixation and total hip arthroplasty directions, results and complications associated with internal fixation in managing these fractures. <br> Methods: In 8 years at 4 centers, 61 patients with associated acetabular fractures (Letournel classification) were treated. The patients were divided into two groups. The total hip arthoplasty (THA) group consisted of 30 patients, while the open reduction internal fixation group had 31 patients. The average age of the patients was 74.7 years. The following parameters were compared: the duration of surgery and hospitalization, the international unit of red blood cell concentrate transfusion, the time for the verticalization of the patient, perioperative complications, Harris hip score, and the short form (12) health survey. The clinical and radiographic follow-up was performed at 1 month, 3 months, 6 months and 12 months and annually thereafter. Patients with post-traumatic osteoarthritis formed the third comparison group.P≤ 0.05 was considered statistically significant according to the analytical Student’s t-test. <br> Results: TheP < 0.05 in favor of theTHAgroup was: surgical time, length of stay, number of the international unit of red blood cell concentrate transfusions, verticalization, quality of life and hip function, a reduction of perioperative complications and reinterventions. <br> Conclusions: Our experience shows that theTHA treatment for acetabular fractures in the elderly is to be preferred. 展开更多
关键词 ACETABULUM Fracture Elderly OSTEOPOROSIS Total HIP ARTHROPLASTY OSTEOSYNTHESIS
下载PDF
Technical note for intraoperative determination of proper acetabular cup size in primary total hip arthroplasty
6
作者 Panagiotis Karampinas John Vlamis +5 位作者 Athanasios Galanis Michail Vavourakis Anastasia Krexi Evangelos Sakellariou Christos Patilas Spiros Pneumaticos 《World Journal of Methodology》 2024年第1期94-101,共8页
BACKGROUND Selecting the optimal size of components is crucial when performing a primary total hip arthroplasty.Implanting the accurate size of the acetabular component can occasionally be exacting,chiefly for surgeon... BACKGROUND Selecting the optimal size of components is crucial when performing a primary total hip arthroplasty.Implanting the accurate size of the acetabular component can occasionally be exacting,chiefly for surgeons with little experience,whilst the complications of imprecise acetabular sizing or over-reaming can be potentially devastating.AIM To assist clinicians intraoperatively with a simple and repeatable tip in elucidating the ambivalence when determining the proper acetabular component size is not straightforwardly achieved,specifically when surgeons are inexperienced or preoperative templating is unavailable.METHODS This method was employed in 263 operations in our department from June 2021 to December 2022.All operations were performed by the same team of joint reconstruction surgeons,employing a typical posterior hip approach technique.The types of acetabular shells implanted were:The Dynasty®acetabular cup system(MicroPort Orthopedics,Shanghai,China)and the R3®acetabular system(Smith&Nephew,Watford,United Kingdom),which both feature cementless press-fit design.RESULTS The mean value of all cases was calculated and collated with each other.We distinguished as oversized an implanted acetabular shell when its size was>2 mm larger than the size of the acetabular size indicator reamer(ASIR)or when the implanted shell was larger than 4 mm compared to the preoperative planned cup.The median size of the implanted acetabular shell was 52(48–54)mm,while the median size of the preoperatively planned cup was 50(48–56)mm,and the median size of the ASIR was 52(50–54)mm.The correlation coefficient between ASIR size and implanted acetabular component size exhibited a high positive correlation with r=0.719(P<0.001).Contrariwise,intraoperative ASIR measurements precisely predicted the implanted cups’size or differed by only one size(2 mm)in 245 cases.CONCLUSION In our study,we demonstrated that the size of the first acetabular reamer not entering freely in the acetabular rim corroborates the final acetabular component size to implant.This was also corresponding in the majority of the cases with conventional preoperative templating.It can be featured as a valid tool for avoiding the potentially pernicious complications of acetabular cup over-reaming and over-sizing in primary total hip arthroplasty.It is a simple and reproducible technical note useful for confirming the predicted acetabular cup size preoperatively;thus,its application could be considered routinely,even in cases where preoperative templating is unavailable. 展开更多
关键词 acetabular shell Total hip arthroplasty HIP ACETABULUM acetabular component Primary hip arthroplasty
下载PDF
Finite Element Analysis of Coronal Shear Fractures of the Femoral Neck: Displacement of the Femoral Head and Effect of Osteosynthetic Implants
7
作者 Yukino Mori Hiroaki Kijima +2 位作者 Mei Terashi Takehiro Iwami Naohisa Miyakoshi 《World Journal of Engineering and Technology》 2024年第3期651-664,共14页
Coronal shear fractures of the femoral neck (CSFF) are the most challenging to treat among proximal femur fractures, directly affecting the life expectancy of patients with osteoporosis. However, an adequate osteosynt... Coronal shear fractures of the femoral neck (CSFF) are the most challenging to treat among proximal femur fractures, directly affecting the life expectancy of patients with osteoporosis. However, an adequate osteosynthesis method has not been elucidated yet. This study investigated the displacement direction of the femoral head fragment and its effect on the bone using finite element method. A finite element model for CSFF was developed from CT image data of a patient with osteoporosis using Mechanical Finder (ver. 11). Subsequently, finite element analyses were performed on six osteosynthesis models under maximum load applied during walking. The compressive stresses, tensile stresses, and compressive strains of each model were examined. The results suggested that the compressive and tensile stress distributions were concentrated on the anterior side of the femoral neck. Compressive strain distribution in the femoral head and neck was concentrated in four areas: at the tip of the blade or lag screw, the anteroinferior side of the blade or lag screw near the fracture site, and the upper right and lower left near the junction of the blade or lag screw and nail. Thus, the distribution of both these stresses revealed that the femoral head fragment was prone to anterior and inferior displacement. Distribution of compressive strains revealed the direction of the stress exerted by the osteosynthetic implant on the bone. The same results were observed in all osteosynthetic implants;thus, the findings could lay the foundation for developing methods for placing osteosynthetic implants less prone to displacement and the osteosynthetic implants themselves. In particular, the study provides insight into the optimal treatment of CSFF. 展开更多
关键词 Finite Element Analysis Proximal Femur fractures Intramedullary Fixation Coronal Shear fractures Femoral Neck
下载PDF
Stress tensor determination by modified hydraulic tests on pre-existing fractures:Method and stress constraints
8
作者 Guiyun Gao Chenghu Wang Ke Gao 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第5期1637-1648,共12页
The hydraulic testing of pre-existing fractures(HTPF)is one of the most promising in situ stress measurement methods,particularly for three-dimensional stress tensor determination.However,the stress tensor determinati... The hydraulic testing of pre-existing fractures(HTPF)is one of the most promising in situ stress measurement methods,particularly for three-dimensional stress tensor determination.However,the stress tensor determination based on the HTPF method requires at least six tests or a minimum of 14-15 tests(under different conditions)for reliable results.In this study,we modified the HTPF method by considering the shear stress on each pre-existing fracture,which increased the number of equations for the stress tensor determination and decreased the number of tests required.Different shear stresses were attributed to different fractures by random sampling;therefore,the stress tensors were obtained by searching for the optimal solution using the least squares criterion based on the Monte Carlo method.Thereafter,we constrained the stress tensor based on the tensile strength criterion,compressive strength criterion,and vertical stress constraints.The inverted stress tensors were presented and analyzed based on the tensorial nature of the stress using the Euclidean mean stress tensor.Two stress-measurement campaigns in Weifang(Shandong Province,China)and Mercantour road tunnel(France)were implemented to highlight the validity and efficiency of the modified HTPF(M-HTPF)method.The results showed that the M-HTPF method can be applied for stress tensor inversion using only three to four tests on pre-existing fractures,neglecting the stress gradient.The inversion results were confined to relatively small distribution dispersions and were significantly reliable and stable due to the shear stresses on the fractures and the stress constraints employed.The M-HTPF method is highly feasible and efficient for complete stress tensor determination in a single borehole. 展开更多
关键词 Stress tensor Hydraulic tests on pre-existing fractures Mean stress Stress constraint Hydraulic fracturing
下载PDF
Bone graft incorporation failure with inappropriate limb load transfer can lead to aseptic acetabular loosening of metal-on-metal prosthesis: A case report
9
作者 RafałStanisław Domagalski Bogdan Dugiełło +6 位作者 Sonia Rokicka Szymon Czech RafałSkowroński Dominika Rokicka Marta Patrycja Wróbel Krzysztof Strojek Tomasz Stołtny 《World Journal of Orthopedics》 2024年第7期668-674,共7页
BACKGROUND Aseptic acetabular loosening can result from various factors that can be categorized into groups:patient-related,surgeon-related and implant-related.We present a case of a 63-year-old patient who at first u... BACKGROUND Aseptic acetabular loosening can result from various factors that can be categorized into groups:patient-related,surgeon-related and implant-related.We present a case of a 63-year-old patient who at first underwent a total hip arthro-plasty(THA)using a metal-on-metal bearing due to hip arthrosis.Follow-up visits revealed no complications after the procedure.Two years after the THA,acetabular component loosening occurred due to subsequent trauma of the opposite hip,necessitating a revision THA using a ceramic-on-ceramic bearing.CASE SUMMARY We aim to illustrate a rare case where the primary reason for undergoing THA revision was not only incomplete bone graft incorporation but also improper limb load distribution.Following the revision arthroplasty,a 9-year follow-up visit revealed improvements in all evaluation measures on questionnaire compared to the state before surgery:Harris Hip Score(before surgery:15;after surgery:95),Western Ontario and McMaster Universities Arthritis Index(before surgery:96;after surgery:0),and Visual Analogue Scale(before surgery:10;after surgery:1).CONCLUSION Opposite-hip trauma caused a weight transfer to the limb after a THA procedure.This process led to a stress shielding effect,resulting in acetabular component loosening. 展开更多
关键词 acetabular loosening Limb load Stress shielding effect Revision hip arthroplasty Case report
下载PDF
Roles of combined femoral and acetabular anteversion in pathological changes of hip dysplasia and hip reconstructive surgery
10
作者 Can Liu Zheng Xu +5 位作者 Jian-Fa Zeng Zhen-Qi Song Yu-Yin Xie Zhong-Wen Tang Jie Wen Sheng Xiao 《World Journal of Orthopedics》 2024年第5期390-399,共10页
Combined femoral and acetabular anteversion is the sum of femoral and acetabular anteversion,representing their morphological relationship in the axial plane.Along with the increasing understanding of hip dysplasia in... Combined femoral and acetabular anteversion is the sum of femoral and acetabular anteversion,representing their morphological relationship in the axial plane.Along with the increasing understanding of hip dysplasia in recent years,numerous scholars have confirmed the role of combined femoral and acetabular anteversion in the pathological changes of hip dysplasia.At present,the reconstructive surgery for hip dysplasia includes total hip replacement and redirectional hip preservation surgery.As an important surgery index,combined femoral and acetabular anteversion have a crucial role in these surgeries.Herein,we discuss the role of combined femoral and acetabular anteversion in pathological changes of hip dysplasia,total hip replacement,and redirectional hip preservation surgery. 展开更多
关键词 Combined anteversion Femoral anteversion acetabular anteversion Hip dysplasia Hip preservation surgery Total hip replacement
下载PDF
Functional Outcomes of Adult Tibia Shaft Fractures Treated with Solid Intramedullary Nails versus Hollow Nails: A Systematic Review
11
作者 Kwadwo Aning Abu Bernard Hammond +5 位作者 Mohammed Issah Suglo Bukari Kizito Kakra Vormawor Ronald Awoonor-Williams David Anyitey-Kokor Paa Kwesi Baidoo Dominic Konadu-Yeboah 《Open Journal of Orthopedics》 2024年第3期149-172,共24页
Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current rev... Introduction: The management of fractures of the tibia shaft is an important aspect of orthopaedic care, and the selection of the surgical method for fixation can substantially impact patient outcomes. The current review aims to compare the outcomes of adult tibia fractures treated with solid nails to those treated with hollow nails. Methods: A search on Scopus, PubMed, and Cochrane Library, using three keywords (Outcome, Tibia shaft fractures, Nail) was conducted in April 2023. Results were compiled and two independent reviewers screened and selected eligible articles After removing duplicates, titles and abstracts were read to exclude ineligible studies. Full-text articles of the remaining papers were read to select eligible studies which were further critically appraised to ascertain their methodological quality. The data extracted from the selected papers were synthesized using a combination of pooling of results, tests of statistical difference (t-test and chi-square) and narrative synthesis methods. Results: A total of 2295 articles were obtained from the databases and citation searching. A total of 9 papers were identified as eligible and included in the review. Findings revealed that there is no statistical difference in the outcomes of tibia fractures treated with either solid or hollow nail groups such as duration of surgery (p = 0.541), rate of delayed and non-union (p = 0.342), and rate of surgical site infections (p = 0.395). Conclusion: Intramedullary nailing of tibia shaft fractures with either solid or hollow nails have similar functional outcomes. 展开更多
关键词 Tibia Shaft fractures Functional Outcome SIGN Nail Hollow Nail
下载PDF
Lateral femoral neck stress fractures: A case report
12
作者 Christiaan AJ Oudmaijer Nuno R Paulino Pereira +3 位作者 David Visser Alexander M Wakker Wout S Veltman Robbart van Linschoten 《World Journal of Orthopedics》 2024年第9期891-901,共11页
BACKGROUND Sport-induced injuries particularly affect young,healthy,and active individuals.Running,a popular and accessible sport,can cause a wide range of injuries,including stress fractures.Stress fractures can occu... BACKGROUND Sport-induced injuries particularly affect young,healthy,and active individuals.Running,a popular and accessible sport,can cause a wide range of injuries,including stress fractures.Stress fractures can occur during high-intensity training or competitions,especially among well-trained amateurs and professional athletes.Adequate diagnosis can be complicated by the typically young age,unremarkable medical history,and vital condition of the patient.Stress fractures present insidiously,and this is specifically the case with stress fractures of the femoral neck.Timely intervention is crucial to prevent progressive displacement,as this can damage the blood supply to the femoral head.CASE SUMMARY A 30-year-old male runner presented to our outpatient clinic with persistent pain 3 weeks after running a marathon.X-ray showed a complete lateral fracture of the left femoral neck,which was treated surgically with a dynamic hip screw.CONCLUSION It is essential for healthcare providers to be vigilant for the subtle symptoms of stress fractures to ensure timely treatment.Early recognition prevents com-plication and leads to a better prognosis. 展开更多
关键词 Stress fractures ATYPICAL Femoral Neck MARATHON DIAGNOSIS Case report
下载PDF
P-and SV-wave dispersion and attenuation in saturated microcracked porous rock with aligned penny-shaped fractures
13
作者 Sheng-Qing Li Wen-Hao Wang +2 位作者 Yuan-Da Su Jun-Xin Guo Xiao-Ming Tang 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期143-161,共19页
P-and SV-wave dispersion and attenuation have been extensively investigated in saturated poroelastic media with aligned fractures.However,there are few existing models that incorporate the multiple wave attenuation me... P-and SV-wave dispersion and attenuation have been extensively investigated in saturated poroelastic media with aligned fractures.However,there are few existing models that incorporate the multiple wave attenuation mechanisms from the microscopic scale to the macroscopic scale.Hence,in this work,we developed a unified model to incorporate the wave attenuation mechanisms at different scales,which includes the microscopic squirt flow between the microcracks and pores,the mesoscopic wave-induced fluid flow between fractures and background(FB-WIFF),and the macroscopic Biot's global flow and elastic scattering(ES)from the fractures.Using Tang's modified Biot's theory and the mixed-boundary conditions,we derived the exact frequency-dependent solutions of the scattering problem for a single penny-shaped fracture with oblique incident P-and SV-waves.We then developed theoretical models for a set of aligned fractures and randomly oriented fractures using the Foldy approximation.The results indicated that microcrack squirt flow considerably influences the dispersion and attenuation of P-and SV-wave velocities.The coupling effects of microcrack squirt flow with the FB-WIFF and ES of fractures cause much higher velocity dispersion and attenuation for P waves than for SV waves.Randomly oriented fractures substantially reduce the attenuation caused by the FB-WIFF and ES,particularly for the ES attenuation of SV waves.Through a comparison with existing models in the limiting cases and previous experimental measurements,we validated our model. 展开更多
关键词 Aligned fractures P-and SV-wave Dispersion and attenuation Microcracked porous background FB-WIFF Elastic scattering Squirt flow
下载PDF
Percutaneous Fixation as an Option for Traumatic Neurologically Intact Thoracolumbar Vertebral Fractures
14
作者 Ahmed Hosameldin Ashraf Osman +1 位作者 Mahmoud Gomaa Mahmoud Ramadan 《Open Journal of Modern Neurosurgery》 2024年第4期246-255,共10页
Background: The most frequent spinal fracture is the thoracolumbar fracture. Minimally invasive percutaneous fixation of cases having thoracolumbar vertebral fractures without neurological impairments has remained con... Background: The most frequent spinal fracture is the thoracolumbar fracture. Minimally invasive percutaneous fixation of cases having thoracolumbar vertebral fractures without neurological impairments has remained controversial. The advantages of minimally invasive percutaneous fixation are decreasing muscle and soft tissue injury, decreasing blood loss and infection rate, in addition to shortening hospital stay and recovery times. In comparison to the open technique, percutaneous fixation is adequate for treating thoracolumbar (TL) fractures without causing neurological impairments & with satisfactory outcomes in terms of kyphosis decline. Elevated radiation exposure to the surgeon &the patient, lack of decompression and fusion via bone graft, & a steep learning curve are all disadvantages of percutaneous fixation of vertebral fractures. Methods: This study was retrospectively conducted on forty-eight patients, age ranging from 16 to 65 years old, with a thoracolumbar (TL) fracture without causing neurological impairments who were meeting the eligibility criteria for fixation in the period from July 2019 to January 2024. Results: We included the forty-eight patients who met the inclusion criteria (34 males and 14 females) their ages ranged from 16 to 65 years. The most common pathology was L1 fracture in 38 patients. No major complications were experienced, only wound infection in five patients which was treated efficiently with repeated dressings and broad-spectrum antibiotics. Four patients experienced misdirected screws, only in one patient the screw encroach into the spinal canal with no deficit experienced, while the other three showed minimally laterally deviated screws. Conclusion: The advantages of percutaneous pedicle screw fixation in thoracolumbar fractures through preservation of posterior musculature, are less blood loss, shorter operative time, lower infection risk, less post-operative pain, shorter rehabilitation time as well as a shorter hospital stay. Limitations of percutaneous fixation include the inability to achieve direct spinal canal decompression and, not having the option to perform a fusion and also requiring a learning curve to master the anatomy and technique. 展开更多
关键词 Thoracolumbar fractures Fracture Stability Percutaneous Fixation
下载PDF
Bipolar hip arthroplasty using conjoined tendon preserving posterior lateral approach in treatment of displaced femoral neck fractures
15
作者 Ting-Xin Yan Sheng-Jie Dong +1 位作者 Bo Ning Yu-Chi Zhao 《World Journal of Clinical Cases》 SCIE 2024年第6期1076-1083,共8页
BACKGROUND Hip fractures account for 23.8%of all fractures in patients over the age of 75 years.More than half of these patients are older than 80 years.Bipolar hemiarthroplasty(BHA)was established as an effective man... BACKGROUND Hip fractures account for 23.8%of all fractures in patients over the age of 75 years.More than half of these patients are older than 80 years.Bipolar hemiarthroplasty(BHA)was established as an effective management option for these patients.Various approaches can be used for the BHA procedure.However,there is a high risk of postoperative dislocation.The conjoined tendon-preserving posterior(CPP)lateral approach was introduced to reduce postoperative dislocation rates.AIM To evaluate the effectiveness and safety of the CPP lateral approach for BHA in elderly patients.METHODS We retrospectively analyzed medical data from 80 patients with displaced femoral neck fractures who underwent BHA.The patients were followed up for at least 1 year.Among the 80 patients,57(71.3%)were female.The time to operation averaged 2.3 d(range:1-5 d).The mean age was 80.5 years(range:67-90 years),and the mean body mass index was 24.9 kg/m^(2)(range:17-36 kg/m^(2)).According to the Garden classification,42.5%of patients were typeⅢand 57.5%of patients were typeⅣ.Uncemented bipolar hip prostheses were used for all patients.Torn conjoined tendons,dislocations,and adverse complications during and after surgery were recorded.RESULTS The mean postoperative follow-up time was 15.3 months(range:12-18 months).The average surgery time was 52 min(range:40-70 min)with an average blood loss of 120 mL(range:80-320 mL).The transfusion rate was 10%(8 of 80 patients).The gemellus inferior was torn in 4 patients(5%),while it was difficult to identify in 2 patients(2.5%)during surgery.The posterior capsule was punctured by the fractured femoral neck in 3 patients,but the conjoined tendon and the piriformis tendon remained intact.No patients had stem varus greater than 3 degrees or femoral fracture.There were no patients with stem subsidence more than 5 mm at the last follow-up.No postoperative dislocations were observed throughout the follow-up period.No significance was found between preoperative and postoperative mean Health Service System scores(87.30±2.98 vs 86.10±6.10,t=1.89,P=0.063).CONCLUSION The CPP lateral approach can effectively reduce the incidence of postoperative dislocation without increasing perioperative complications.For surgeons familiar with the posterior lateral approach,there is no need for additional surgical instruments,and it does not increase surgical difficulty. 展开更多
关键词 Conjoined tendon preserving Bipolar hip arthroplasty Femoral neck fractures Postoperative dislocation Posterolateral approach
下载PDF
Meta-analysis of the clinical efficacy of the Gamma3 nail vs Gamma3U-blade system in the treatment of intertrochanteric fractures
16
作者 Xuan Wu Bo Gao 《World Journal of Orthopedics》 2024年第3期285-292,共8页
BACKGROUND The traditional Gamma3 nail is a mainstream treatment for femoral intertrochanteric fractures.Literature reports that the Gamma3U-blade system can increase the stability of the Gamma3 nail and reduce compli... BACKGROUND The traditional Gamma3 nail is a mainstream treatment for femoral intertrochanteric fractures.Literature reports that the Gamma3U-blade system can increase the stability of the Gamma3 nail and reduce complication incidence.However,comparative studies between the Gamma3U-blade and Gamma3 systems are limited;hence,this meta-analysis was performed to explore the clinical efficacy of these two surgical methods.AIM To investigate the clinical efficacy of Gamma3 and Gamma3 U-blade for intertrochanteric fractures.METHODS A computerized search for Chinese and English literature published from 2010 to 2022 was conducted in PubMed,Cochrane,CNKI,Wanfang,and VIP databases.The search keywords were gamma 3,gamma 3 U blade,and intertrochanteric fracture.Additionally,literature tracking was performed on the references of published literature.The data were analyzed using Revman 5.3 software.Two individuals checked the inputs for accuracy.Continuous variables were described using mean difference and standard deviation,and outcome effect sizes were expressed using ratio OR and 95%confidence interval(CI).High heterogeneity was considered at(P<0.05,I2>50%),moderate heterogeneity at I2 from 25%to 50%,and low heterogeneity at(P≥0.05,I2<50%).RESULTS Following a comprehensive literature search,review,and analysis,six articles were selected for inclusion in this study.This selection comprised five articles in English and one in Chinese,with publication years spanning from 2016 to 2022.The study with the largest sample size,conducted by Seungbae in 2021,included a total of 304 cases.Statistical analysis:A total of 1063 patients were included in this meta-analysis.The main outcome indicators were:Surgical time:The Gamma3U blade system had a longer surgical time compared to Gamma3 nails(P=0.006,I2=76%).Tip-apex distance:No statistical significance or heterogeneity was observed(P=0.65,I2=0%).Harris Hip score:No statistical significance was found,and low heterogeneity was detected(P=0.26,I2=22%).Union time:No statistical significance was found,and high heterogeneity was detected(P=0.05,I2=75%).CONCLUSION Our study indicated that the Gamma3 system reduces operative time compared to the Gamma3 U-blade system in treating intertrochanteric fractures.Both surgical methods proved to be safe and effective for this patient group.These findings may offer valuable insights and guidance for future surgical protocols in hip fracture patients. 展开更多
关键词 Gamma3 nail Gamma3U-Blade system Femoral intertrochanteric fractures META-ANALYSIS
下载PDF
Direct anterior compared to posterior approach for hip hemiarthroplasty following femoral neck fractures
17
作者 Kevin A Wu Alexandra N Krez Albert T Anastasio 《World Journal of Orthopedics》 2024年第6期605-607,共3页
The differences in complication rates between the direct anterior and posterior approaches for hemiarthroplasty in elderly patients with femoral neck fractures are not yet fully understood.Dislocation,a severe complic... The differences in complication rates between the direct anterior and posterior approaches for hemiarthroplasty in elderly patients with femoral neck fractures are not yet fully understood.Dislocation,a severe complication associated with increased mortality and often requiring additional surgery,may occur less frequently with the direct anterior approach compared to the posterior approach.Careful consideration of patient demographics is essential when planning the surgical approach.Future research in this area should focus on robust randomized controlled trials involving elderly patients recovering from femoral neck fractures. 展开更多
关键词 Direct anterior approach Posterior approach HEMIARTHROPLASTY Femoral neck fractures ARTHROPLASTY DISLOCATION Surgical technique
下载PDF
Factors influencing further vertebral height loss following percutaneous vertebroplasty in osteoporotic vertebral compression fractures:A 1-year follow-up study
18
作者 Zhong-Qiu Tang Shao-Bo He +3 位作者 Dong-Yang Yu Hai-Mao Luo Xue-Hong Xing Yong-Wen Zhou 《World Journal of Clinical Cases》 SCIE 2024年第21期4609-4617,共9页
BACKGROUND Osteoporotic vertebral compression fractures(OVCFs)contribute to back pain and functional limitations in older individuals,with percutaneous vertebroplasty(PVP)emerging as a minimally invasive treatment.How... BACKGROUND Osteoporotic vertebral compression fractures(OVCFs)contribute to back pain and functional limitations in older individuals,with percutaneous vertebroplasty(PVP)emerging as a minimally invasive treatment.However,further height loss post-PVP prompts investigation into contributing factors.AIM To investigate the factors associated with further height loss following PVP with cement augmentation in OVCF patients.METHODS A total of 200 OVCF patients who underwent successful PVP between January 2021 and December 2022 were included in this study.“Further height loss”during 1 year of follow-up in OVCF patients with bone edema was defined as a vertical height loss of≥4 mm.The study population was divided into two groups for analysis:The“No Further Height Loss group(n=179)”and the“Further Height Loss group(n=21).”RESULTS In comparing two distinct groups of patients,significant differences existed in bone mineral density(BMD),vertebral compression degree,prevalence of intravertebral cleft(IVF),type of bone cement used,and cement distribution patterns.Results from binary univariate regression analysis revealed that lower BMD,the presence of IVF,cleft distribution of bone cement,and higher vertebral compression degree were all significantly associated with further height loss.Notably,the use of mineralized collagen modified-poly(methyl methacrylate)bone cement was associated with a significant reduction in the risk of further height loss.In multivariate regression analysis,lower BMD and the presence of IVF remained significantly associated with further height loss.CONCLUSION Further height loss following PVP in OVCF patients is influenced by a complex interplay of factors,especially lower BMD and the presence of IVF.These findings underscore the importance of assessing and managing these factors when addressing height loss following PVP in OVCF patients. 展开更多
关键词 Percutaneous vertebroplasty Osteoporotic vertebral compression fractures Further height loss Bone mineral density Intravertebral cleft
下载PDF
Axial load-share ratio testing to assess the healing of open tibial fractures treated with the Taylor Spatial Frame
19
作者 Zhao Liu Jin-Wei Liu +7 位作者 Qi-Jun Zhao Hong-Zhou Li Ning-Ning Zhang Hong-Liang Zhang Yu Gou Xun Sun Tao Zhang Wei-Guo Xu 《Biomedical Engineering Communications》 2024年第3期23-30,共8页
Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy ... Background:The Taylor Spatial Frame(TSF)has gained popularity among orthopedic surgeons for treating open fractures.However,a key challenge is the timely and safe removal of the frame.This study assessed the efficacy and safety of axial load-share ratio(ALSR)testing to evaluate callus healing strength after TSF treatment of open tibial fractures.Methods:A retrospective case-control study was conducted,analyzing 180 adult patients with open tibial fractures treated at Tianjin Hospital’s Orthopedic Limb Correction Unit between August 2019 and August 2022.All patients underwent TSF external fixation surgery,and were divided into two groups based on ALSR testing.Group I(92 patients)underwent ALSR testing,with frame removal if the test value fell below 5%.Traditional methods were used for fixator removal guidance in Group II(88 patients).Clinical outcomes,including fixation duration,complications after fixator removal,and Johner-Wruhs functional scores,were compared between the two groups.Results:The groups showed no statistically significant differences(P>0.05)in sex,age,injury side,body mass index,surgery timing,or fracture type.Group I had a significantly shorter fixation duration(25.85±5.57 weeks)compared to Group II(31.82±6.98 weeks)(P<0.05).Following fixator removal,Group I demonstrated superior Johner-Wruhs scores compared to Group II,indicating better outcomes(P<0.05).Complication rates did not differ significantly between the groups at the last follow-up(P>0.05).Conclusion:Regular postoperative ALSR testing could safely and effectively guide TSF removal following open tibial fracture treatment.This method significantly reduced fixation duration compared to traditional guidance methods while maintaining efficacy and safety. 展开更多
关键词 tibial fractures external fixators fracture healing axial load
下载PDF
Pelvic fractures in blunt trauma patients:A comparative study
20
作者 Alexander A Fokin Joanna Wycech Knight +5 位作者 Madison E Tharp Kyler C Brinton Phoebe K Gallagher Justin Fengyuan Xie Russell D Weisz Ivan Puente 《World Journal of Orthopedics》 2024年第5期418-434,共17页
BACKGROUND Pelvic fractures(PF)with concomitant injuries are on the rise due to an increase of high-energy trauma.Increase of the elderly population with age related comorbidities further complicates the management.Ab... BACKGROUND Pelvic fractures(PF)with concomitant injuries are on the rise due to an increase of high-energy trauma.Increase of the elderly population with age related comorbidities further complicates the management.Abdominal organ injuries are kindred with PF due to the proximity to pelvic bones.Presence of contrast blush(CB)on computed tomography in patients with PF is considered a sign of active bleeding,however,its clinical significance and association with outcomes is debatable.AIM To analyze polytrauma patients with PF with a focus on the geriatric population,co-injuries and the value of contrast blush.METHODS This retrospective cohort study included 558 patients with PF admitted to level 1 trauma center(01/2017-01/2023).Analyzed variables included:Age,sex,mechanism of injury(MOI),injury severity score(ISS),Glasgow coma scale(GCS),abbreviated injury scale(AIS),co-injuries,transfusion requirements,pelvic angiography,embolization,laparotomy,orthopedic pelvic surgery,intensive care unit and hospital lengths of stay,discharge disposition and mortality.The study compared geriatric and non-geriatric patients,patients with and without CB and abdominal co-injuries.Propensity score matching was implemented in comparison groups.RESULTS PF comprised 4%of all trauma admissions.89 patients had CB.286(52%)patients had concomitant injuries including 93(17%)patients with abdominal co-injuries.Geriatric patients compared to non-geriatric had more falls as MOI,lower ISS and AIS pelvis,higher GCS,less abdominal co-injuries,similar CB and angio-embolization rates,less orthopedic pelvic surgeries,shorter lengths of stay and higher mortality.After propensity matching,orthopedic pelvic surgery rates remained lower(8%vs 19%,P<0.001),hospital length of stay shorter,and mortality higher(13%vs 4%,P<0.001)in geriatric patients.Out of 89 patients with CB,45(51%)were embolized.After propensity matching,patients with CB compared to without CB had more pelvic angiography(71%vs 12%,P<0.001),higher embolization rates(64%vs 22%,P=0.02)and comparable mortality.CONCLUSION Half of the patients with PF had concomitant co-injuries,including abdominal co-injuries in 17%.Similarly injured geriatric patients had higher mortality.Half of the patients with CB required an embolization. 展开更多
关键词 Pelvic fractures Geriatric trauma patients Abdominal co-injuries Contrast blush Contrast extravasation ANGIOEMBOLIZATION Polytrauma patients Surgical interventions Blunt trauma External and internal fixation for pelvic stabilization
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部