Control of an Active Filter by Duty Cycle Modulation (DCM) for the Harmonic Decontamination of a Three-Phase Electrical Network 被引量:1
1
作者 Théodore Patrice Nna Nna Salomé Ndjakomo Essiane Stève Pérabi Ngoffé 《Journal of Power and Energy Engineering》 2020年第7期1-14,共14页
This paper presents the control of the active filter by Duty Cycle Modulation (DCM) for the harmonic pollution control of a three-phase electrical system. Several research works have preceded this work, but most of th... This paper presents the control of the active filter by Duty Cycle Modulation (DCM) for the harmonic pollution control of a three-phase electrical system. Several research works have preceded this work, but most of them deal with the control by pulse-width modulation and the differences lie around the THD reduction performance, the quality of the wave obtained, the simplicity of the scheme and the cost of the control. For this purpose, we propose a very innovative approach to active filter control which aims at reducing the current THD at a lower rate than pulse-width modulation techniques improving at the same time the wave quality with a more simplified control scheme. First we present the schematic diagram of the active filter, then we present the design of the control of this active filter based on the real and imaginary instantaneous power method which uses the algebraic “Clark” transformation. The Duty Cycle Modulation controller is used to obtain the required control commands to be injected to the inverter. We then developed a simulink model of the active filter to validate this study. The simulations were performed in the Matlab/Simulink environment. The results obtained show a significant improvement on the harmonic current control techniques for the THD of 1.02% which was 26.25%, the elimination of noise in the signal and the simplicity of the control with an easier implementation than the pulse width modulation (PWM) make the Duty Cycle Modulation (DCM) control a very promising tool. 展开更多
关键词 PWM DCM active filter INVERTER
下载PDF
Implementation of PSOANN Optimized PI Control Algorithm for Shunt Active Filter
2
作者 M.Sujith S.Padma 《Computer Modeling in Engineering & Sciences》 SCIE EI 2020年第3期863-888,共26页
This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI... This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI),series inductor and DC bus and nonlinear load.The proposed hybrid approach is a combination of Particle Swarm Optimization(PSO)and Artificial Neural Network(ANN)termed as PSOANN.The PI controller gain parameters of kp and ki are optimized with the help of PSOANN.The PSOANN improves the accuracy of tuning the gain parameters under steady and dynamic load conditions;thereby it reduces the values of THD within the prescribed limits of IEEE 519.The PSO optimizes the dataset of terminal voltage and DC voltage present in shunt active filter for different load condition.The optimized dataset acts as the input for the controller to predict the optimal gain with minimal error and to generate the optimized control signal for the SAF.The proposed methodology is modelled and simulated with the help of MATLAB/Simulink platform and illustrated the few test cases considered for exhibiting the performance of proposed hybrid controller.The experimental results are measured with developed laboratory prototype and compared with the simulation results to validate the effectiveness of the proposed control methodology. 展开更多
关键词 Artificial neural network particle swarm optimization shunt active filter voltage source inverter total harmonic distortions.
下载PDF
Harmonic Reduction in Wind Power Generating System Using Shunt Active Filter with SPWM Technique
3
作者 R. Zahira A. Peer Fathima Ranganath Muthu 《Circuits and Systems》 2016年第4期157-165,共9页
Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear... Due to environmental conditions, the wind power generation is fluctuating in nature. This affects the electrical network interconnected with these systems. When the wind power generators are connected to the nonlinear loads, there is distortion in the waveform. These distortions should be within limits according to national and international guidelines framed for power quality. This paper presents a mitigation technique with a shunt active filter, which reduces harmonic distortion to the permitted limit. Sine pulse width modulation (SPWM) control scheme is used to control shunt active filter. This technique eliminates harmonic distortion and maintains unity power factor. The simulation for proposed method is carried out using MATLAB/SIMULINK and results are validated. 展开更多
关键词 Wind Power Generation SPWM Shunt active filter HARMONIC Power Quality
下载PDF
CCII-Based Inverse Active Filters with Grounded Passive Components
4
作者 Takao Tsukutani Yasutomo Kunugasa Noboru Yabuki 《Journal of Electrical Engineering》 2018年第4期212-215,共4页
关键词 Analog circuits inverse active filters second generation current conveyors
下载PDF
DC active power filter based on model predictive control for DC bus overvoltage suppression of accelerator grid power supply 被引量:1
5
作者 张鸿淇 朱帮友 +3 位作者 马少翔 李志恒 张明 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第6期1-13,共13页
The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated... The China Fusion Engineering Test Reactor plans to build a 200 k V/25 A acceleration grid power supply(AGPS)for the negative-ion-based neutral beam injector prototype system.The AGPS uses a rectifier-inverter-isolated step-up structure.There is a DC bus between the rectifier and the inverter.In order to limit DC bus voltage ripple and transient fluctuations,a large number of capacitors are used,which degrades the reliability of the power supply and occupies a large amount of space.This work finds that due to the difference in the turn-off time of the rectifier and the inverter,the capacitance mainly depends on the rectifier current when the inverter is turned off.On this basis,an active power filter(APF)scheme is proposed to absorb the current.To enhance the dynamic response ability of the APF,model predictive control is adopted.In this paper,the circuit structure of the APF is introduced,the prediction model is deduced,the corresponding control strategy and signal detection method are proposed,and the simulation and experimental results show that APF can track the transient current of the DC bus and reduce the voltage fluctuation significantly. 展开更多
关键词 CFETR NBI accelerator grid power supply power active filter model predictive control
下载PDF
A new shunt DC active filter of power supply in a steady high magnetic field facility 被引量:1
6
作者 王磊 刘小宁 王灿 《Chinese Physics C》 SCIE CAS CSCD 2011年第5期494-499,共6页
A DC active power filter is an indispensable part in a high power and high stability power supply system, especially in the power supply system of the Steady High Magnetic Field Facility, which requires that the curre... A DC active power filter is an indispensable part in a high power and high stability power supply system, especially in the power supply system of the Steady High Magnetic Field Facility, which requires that the current ripple should be limited to 50 parts per million. In view of the disadvantages of the series DC active power filter and shunt Pulse Width Modulation DC active filter, this paper puts forward a novel DC active filter by combining the advantages of the transistor regulator and the shunt type. The structure and principle of the new shunt linear active filter are introduced. Meanwhile, the design of several key components that construct the new shunt linear active filter is also analyzed. The simulation model and an experimental prototype of the shunt linear active filter are developed, and the results verify that the parameter design is reasonable and the shunt active filter has a good filter effect. 展开更多
关键词 high stable power supply RIPPLE SHUNT linear DC active filter
原文传递
Rapid transaction to load variations of active filter supplied by PV system 被引量:1
7
作者 M. BENADJA S. SAAD A. BELHAMRA 《Frontiers in Energy》 SCIE CSCD 2014年第3期335-344,共10页
This paper deals with the analysis and control of a photovoltaic (PV) system connected to the main supply through a Boost converter and shunt active filter supplied by a PV system providing continuous supply of nonl... This paper deals with the analysis and control of a photovoltaic (PV) system connected to the main supply through a Boost converter and shunt active filter supplied by a PV system providing continuous supply of nonlinear load in variation. A robust control of a PV system connected to the grid while feeding a variable nonlinear load is developed and highlighted. This development is based on the control of the Boost converter to extract the maximum power from the PV system using the Perturb and Observe (P and O) algorithm in the presence of temperature and illumination. The proposed modeling and control strategy provide power to the variable nonlinear load and facilitates the transfer of power from solar panel to the grid while improving the quality of energy (harmonic currents compensation, power factor compensation and dc bus voltage regulation). Validation of the developed model and control strategy is conducted using power system simulator Sim-Power System Blockset Matlab/Simulink. To demonstrate the effectiveness of the shunt active filter to load changes, the method of instantaneous power (pq theory) is used to identify harmonic currents. The obtained results show an accurate extraction of harmonic currents and perfect compensation of both reactive power and harmonic currents with a lower THD and in accordance with the IEEE-519 standard. 展开更多
关键词 solar panels maximum power point tracking(MPPT) DC/DC converter (Boost) shunt active filter instantaneous power control power quality harmonics imbalances reactive energy
原文传递
A simple digital control algorithm for three phase shunt active filter: simulation and experimentation 被引量:1
8
作者 Subbaraman SRINATH Chandan KUMAR, M. P. SELVAN 《Frontiers in Energy》 SCIE CSCD 2014年第1期119-128,共10页
A novel and simple ifrea! control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt active filter (SAF). The simulation and prototype construction of SAF is cond... A novel and simple ifrea! control algorithm using digital signal processor (DSP) has been proposed and realized for a three phase shunt active filter (SAF). The simulation and prototype construction of SAF is conducted to compensate the reactive power and harmonics in a distribution system. The major feature of the proposed ifreal algorithm is that it does not require unit vector templates and any transformations for the reference current genera- tion of SAF. This reduces the computational complexity and makes the control flexible and faster. The simulation is conducted in MATLAB/SIMULINK while DSP TMS320LF2407 is employed in the digital implementation of hysteresis current control (HCC) for experimentation. The hardware results correlate with the simulation results in reducing the total harmonic distortion (THD) of the source current and achieving unity power factor. 展开更多
关键词 shunt active filter (SAF) power quality voltage source inverter (VSI) digital signal processor(DSP) total harmonic distortion (THD) power factorimprovement
原文传递
Improved PLL Tuning of Shunt Active Power Filter for Grid Connected Photo Voltaic Energy System
9
作者 Rajmohan Rajalakshmi Vairamani Rajasekaran 《Circuits and Systems》 2016年第10期3063-3080,共18页
This research work brings out the unique predictive current control method for attaining an efficient grid connected Photo Voltaic (PV) system by Shunt Active Power Filter (SAPF) as grid connected converter. The major... This research work brings out the unique predictive current control method for attaining an efficient grid connected Photo Voltaic (PV) system by Shunt Active Power Filter (SAPF) as grid connected converter. The major objective of the research work is to address the presence of Direct Current (DC) component, frequency improvement, quicker theta response, voltage magnitude estimation in the input signal of the Phase Locked Loop (PLL) which is challenging. This work focuses on tuning the PLL block (K<sub>p</sub>, K<sub>i</sub>, K<sub>v</sub> and K<sub>o</sub>) through Artificial Bee Colony (ABC) optimization algorithm. The proposed ABC based modified three-phase PLL method is based on adding a new loop inside the PLL structure. In power converters, ABC algorithm is used to select the optimal switching states. The voltage vector which minimizes a cost optimization function is selected. Simulation is carried out for both balanced and unbalanced system and the results validate that the performance of the proposed approach is better in terms of harmonic compensation as per the IEEE standards within ±5%, power factor improvement of the system, quicker theta tracking and suppression of frequency jump with the interconnection of PV system. 展开更多
关键词 Shunt active filter Phase Locked Loop Artificial Bee Colony Current Control Method PV System
下载PDF
Invertebrate community characteristics in biologically active carbon filter 被引量:5
10
作者 Xiaowei Li Yufeng Yang +2 位作者 Lijun Liu Jinsong Zhang Qing Wang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2010年第5期648-655,共8页
Biologically active carbon (BAC) system was set up in a water plant of South China during January to December 2007,to study the invertebrate community characteristics of BAC filter.Thirty-seven invertebrate species ... Biologically active carbon (BAC) system was set up in a water plant of South China during January to December 2007,to study the invertebrate community characteristics of BAC filter.Thirty-seven invertebrate species were found,of which 28 belonging to rotifers.Filter operation could lead to an output of invertebrates in high abundances with the filtrate,and the maximum density could reach 5608 individuals/m 3.Average abundances in the effluent water increased in 27-33 folds in comparison to the influent water during the sampling period.Invertebrate community succession had the following trend:filter-feeding animals → small benthic invertebrates → large benthic and resistant invertebrates.Abundances of large-sized invertebrates (copepod adult and oligochaete) at bigger-media column were significantly higher than that at small-media column.The results implied the abundant species diversity of invertebrate in BAC filter.The relationship between invertebrate and biofilm still remain to be studied in detail. 展开更多
关键词 biologically active carbon filter INVERTEBRATE community characteristics filter media
下载PDF
Current control for a shunt hybrid active power filter using recursive integral PI 被引量:1
11
作者 Wei ZHAO An LUO Ke PENG Xia DENG 《控制理论与应用(英文版)》 EI 2009年第1期77-80,共4页
This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of d... This paper presents a current control method for a shunt hybrid active power filter (HAPF) using recursive integral PI algorithm. The method improves the performance of the HAPF system by reducing the influence of detection accuracy, time delay of instruction current calculation and phase displacement of output filter. Fuzzy logic based set-point weighing algorithm is combined in the control scheme to enhance its robustness and anti-interference ability. The proposed algorithm is easy to implement for engineering applications and easy to compute. Experiment results have verified the validity of the proposed controller. Furthermore, the proposed recursive integral PI algorithm can also be applied in the control of periodic current as in AC drivers. 展开更多
关键词 Power electronics Shunt hybrid active power filter Recursive integral PI Fuzzy inference
下载PDF
Increasing the operating area of shunt active filters by advanced nonlinear control
12
作者 Andrea TILLI Christian CONFICONI 《Control Theory and Technology》 EI CSCD 2015年第2期115-140,共3页
This work is aimed to rigorously manage voltage saturation and maximum current constraints in Shunt Active Filters. In this respect, assuming 'unconstrained' control algorithms have already been defined to ach... This work is aimed to rigorously manage voltage saturation and maximum current constraints in Shunt Active Filters. In this respect, assuming 'unconstrained' control algorithms have already been defined to achieve standard objectives for such devices(i.e. current tracking for harmonic compensation and DC-bus voltage boundness), a plug-in unit, oriented to extend the system operating region and at the same time preserving good performance under large transients and overload conditions, is presented.This solution allows to improve availability, robustness and composability of Shunt Active Filters, which are expected to be key features in present and next generation complex and possibly 'smart' power grids. The proposed unit is composed by two parts.First, a suitable anti-windup strategy is defined in order to deal with control input saturation. Its main purpose is to preserve the original 'unconstrained error dynamics', in face of input saturation, while guaranteeing low computational burden and reduced performance impairment(the latter goal, in harmonic compensation context, leads to rather non-standard problem formulation).To this aim, the anti-windup acts on the current references through a suitably-designed additional dynamics. Then, in order to cope with current limitations, an additional strategy has been designed; again the current references is suitably shaped to comply with the features and bounds of the system, augmented with the above-mentioned anti-windup solution. The proposed scheme can be simply joined to any kind of unconstrained controller adopted to steer Shunt Active Filters. In this work, an Internal-Model-based current controller is adopted as a benchmark case. The proposed approach is validate through extensive simulation tests. 展开更多
关键词 Shunt active filters power quality anti-windup units control of constrained systems
全文增补中
Coordinated Control Strategy for Harmonic Compensation of Multiple Active Power Filters 被引量:1
13
作者 Jianfeng Yang Rende Qi +1 位作者 Yang Liu Yu Ding 《Energy Engineering》 EI 2022年第2期609-620,共12页
In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of acti... In order to minimize the harmonic distortion rate of the current at the common coupling point,this paper proposes a coordinated allocation strategy of harmonic compensation capacity considering the performance of active power filters(APF).On the premise of proportional distribution of harmonic compensation capacity,the harmonic compensation rate of each APF is considered,and the harmonic current value of each APF to be compensated is obtained.At the same time,the communication topology is introduced.Each APF takes into account the compensation ability of other APFs.Finally,three APFs with different capacity and performance are configured at the harmonic source to suppress the same harmonic source,and the harmonic distortion rate is reduced to 1.73%.The simulation results show that the strategy can effectively improve the compensation capability of the multiple APF cascaded system to the power grid without increasing the installed capacity. 展开更多
关键词 active power filter collaborative optimization harmonic compensation rate weighting factor communication topology
下载PDF
Lag compensation errors in active power filters based on DSP controllers
14
作者 WANG, Xuedan JIANG, Jianguo GAO, Baichen 《Mining Science and Technology》 EI CAS 2010年第2期312-316,共5页
The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the det... The growing problems of harmonic pollution on coal mine power lines caused by high-power DC drive systems has increased the use of active power filters.We analyzed compensation errors caused by the time lag in the detecting circuits of an active power filter based on DSP control.We derived a mathematical model for the compensation error starting from the error estimation when a single distortion frequency is present.This model was then extended to the case where multiple frequencies are present in the distortion.A formula for a general theory of compensation error with fixed load and fixed lag time is presented.The theoretical analysis and experimental results show that the delay time of an active power filter mainly arises from the sampling time.Lower sampling frequencies introduce larger compensation errors in the active power filter reference current. 展开更多
关键词 active power filter digital signal processing MODELING compensation error
下载PDF
A Novel Starting Impulse Suppression Method for Active Power Filter Based on Slowly Rising Curve
15
作者 Jianfeng Yang Yu Ding 《Energy Engineering》 EI 2021年第6期1839-1853,共15页
With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,a... With the widespread application of power electronic equipment in the power grid,the harmonic problem of the power grid becomes more pronounced,reducing the efficiency of power production,transmission,and utilization,and interfering with the normal operation of the power grid.Based on the requirements of harmonic suppression and power system protection,a shunt active power filter(SAPF)is proposed as an effective harmonic suppression method.However,there are problems with impulse current and impulse voltage in the starting process of SAPF.Impulse current and impulse voltage cause the power grid and switchgear to bear greater current stress and voltage stress,which seriously affect the security and reliability of the power grid and may damage the switchgear.To effectively solve the problem of impulse current and impulse voltage,the starting process of SAPF is divided into the uncontrolled rectification stage and the transition stage.The mathematical model of the DC side of APF is established.The causes of impulse current and impulse voltage in the uncontrolled rectifier and transition phases are analyzed.By introducing voltage square,a new starting impulse suppression strategy of active power filter based on the slow rising curve is proposed,fundamentally solving the problems of impulse current and impulse voltage.Simulation results verify the effectiveness and feasibility of this method. 展开更多
关键词 Shunt active power filter starting shock impulse current impulse voltage
下载PDF
Research on Direct Power Control of DC Side for the Active Power Filter
16
作者 XU Zhenfang WANG Lei 《Instrumentation》 2017年第2期16-21,共6页
This paper addresses the principle and control topology of active pow er filter( APF). The control strategy of direct pow er control based on DC side is introduced,and the control output is implemented by using the pr... This paper addresses the principle and control topology of active pow er filter( APF). The control strategy of direct pow er control based on DC side is introduced,and the control output is implemented by using the principle of hysteresis control.The active pow er filter can effectively control the pow er system harmonics,improve the quality of electricity and purify pow er grid. The experimental results are provided to illustrate that the direct pow er control based on DC side has the advantages of simple structure,stable DC output voltage and fast dynamic response. 展开更多
关键词 DC Side Power Control active Power filter Hysteresis Control
下载PDF
An Efficient Particle Swarm Optimization Technique for 4-Leg Shunt Active Power Filter
17
作者 V. Parimala S. Chenthur Pandian D. Ganeshkumar 《Circuits and Systems》 2016年第8期1546-1559,共14页
This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Opt... This paper describes the mitigation of harmonics in source and neutral current in three phase four wire system based on 4-leg shunt active power filter under balanced and unbalanced load conditions. Particle Swarm Optimization (PSO) and conventional Proportional Integral (PI) controller are used as control techniques to analyze the control performance of 4-leg shunt active power filter. The synchronous reference frame (SRF) method is used to extract reference current in 4-leg shunt active filter. The Hysteresis Current Controller (HCC) is used to generate gate pulses for Voltage Source Inverter (VSI) based 4-leg shunt active power filter. The proposed PSO technique gives less percentage of Total Harmonic Distortion (THD) value in source and neutral current and settling time of the DC capacitor voltage compared to conventional PI controller technique. The model of the proposed system performance was validated using MATLAB/Simulink environment. 展开更多
关键词 Hysteresis Current Controller Particle Swarm Optimization Shunt active Power filter SRF Method
下载PDF
Real-Time Method for Detecting Harmonic and Reactive Currents of Single-Phase Circuits 被引量:1
18
作者 张秀峰 丁菊霞 《Journal of Southwest Jiaotong University(English Edition)》 2006年第2期135-141,共7页
According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. Th... According to the characteristics of single-phase circuits and demand of using active filter for real-time detecting harmonic and reactive currents, a detecting method based on Fryze's power definition is proposed. The results of theoretical analysis and simula- tion show that the proposed method is effective in realtime detecting of instantaneous harmonic and reactive currents in single-phase circuits. When only detecting the total reactive currents, this method does not need a phase-locked loop circuit, and it also can be used in some special applications to provide different compensations on the ground of different requirements of electric network. Compared with the other methods based on the theory of instantaneous reactive power, this method is simple and easy to realize. 展开更多
关键词 active filter HARMONIC Reactive current Real-time detection Single-phase circuit Electric-network
下载PDF
Contribution to Harmonic Depollution Control by the Use of Adaptive Hybrid Filter Type TLC: Case of Control by Modulated Hysteresis
19
作者 Luc Vivien Assiene Mouodo Jean Gaston Tamba +4 位作者 Olivier Sosso Mayi Antoine Hanna Nohra Lawren Bibaya Maurice Fadel Hadi Kanaan 《Energy and Power Engineering》 2020年第10期578-602,共25页
In this article, we propose a topology of a TLC-HAPF power filter as a harmonic compensator for an optimization of the pollution control of electrical networks. This filter consists of an active part and a passive par... In this article, we propose a topology of a TLC-HAPF power filter as a harmonic compensator for an optimization of the pollution control of electrical networks. This filter consists of an active part and a passive part in order to reduce or limit switching losses during current injection into networks thanks to its TLC module. This topology also provides solutions dynamic performance issues, resonance and lack of compensation capacity for imbalance cases. It also offers a greater range of compensation than conventional active models which do not offer as well as an intermediate circuit voltage in the order of 105 V to 109 V relatively lower than others models (600 v). A modulated hysteresis control of this topology is therefore also developed in this article and allows to obtain a network analysis on the three phases at three levels: source side, load side, and finally at the connection of the filter to the network, allowing to specify for these different positions the value of the current spectrum and its THD at this well-defined moment. 展开更多
关键词 Hybrid Adaptive active filter Modulated Hysteresis THD Harmonic Pollution Control
下载PDF
Multifunction Filter Employing Current Differencing Buffered Amplifier
20
作者 Tajinder Singh Arora Udit Rana 《Circuits and Systems》 2016年第5期543-550,共8页
This paper proposes a new filter biquad circuit, which utilizes three Current Differencing Buffered Amplifiers (CDBA), two capacitors and five resistors, and operates in the trans-resistance mode. This multi-input and... This paper proposes a new filter biquad circuit, which utilizes three Current Differencing Buffered Amplifiers (CDBA), two capacitors and five resistors, and operates in the trans-resistance mode. This multi-input and single-output multifunction filter uses only grounded capacitors. All the employed resistors are either grounded or virtually grounded, which is an important parameter for its implementation as an integrated circuit. The circuit enjoys independent tunability of angular frequency and bandwidth. The 0.5 μm technology process parameters have been utilized to test and verify the performance characteristics of the circuit using PSPICE. The non-ideal analysis and sensitivity analysis, transient response, Monte-Carlo analysis and calculations of total harmonic distortion have also been shown. 展开更多
关键词 active filters Current Differencing Buffered Amplifier Biquadratic filter KHN-Biquad