When using traditional drive circuits,the enhancement-mode GaN(eGaN)HEMT will be affected by high switching speed characteristics and parasitic parameters leading to worse crosstalk problems.Currently,the existing cro...When using traditional drive circuits,the enhancement-mode GaN(eGaN)HEMT will be affected by high switching speed characteristics and parasitic parameters leading to worse crosstalk problems.Currently,the existing crosstalk suppression drive circuits often have the disadvantages of increased switching loss,control complexity,and overall electromagnetic interference(EMI).Therefore,this paper combines the driving loop impedance control and the active Miller clamp method to propose an improved active Miller clamp drive circuit.First,the crosstalk mechanism is analyzed,and the crosstalk voltage model is established.Through the crosstalk voltage evaluation platform,the influencing factors are evaluated experimentally.Then,the operating principle of the improved active Miller clamp drive circuit is discussed,and the optimized parameter design method is given.Finally,the effect of the improved active Miller clamp method for suppressing crosstalk is experimentally verified.The crosstalk voltage was suppressed from 3.5 V and-3.5 V to 1 V and-1.3 V,respectively,by the improved circuit.展开更多
A simple single-stage AC/DC converter circuit with active clamp is presented. The operation theory and state are analyzed. The experimental results show that the voltage across main switch can be clamped to a certain ...A simple single-stage AC/DC converter circuit with active clamp is presented. The operation theory and state are analyzed. The experimental results show that the voltage across main switch can be clamped to a certain value,and zero voltage switching (ZVS) can be achieved. The voltage stress and switching loss are both decreased. In range of the whole load,power factors can be always more than 97%,and the highest efficiency can reach 88%.展开更多
In medium voltage-high power(MV-HP)applications,the high switching frequency of power converter will result in unnecessary energy losses,which directly affect efficiency.To resolve this issue,a novel finite control se...In medium voltage-high power(MV-HP)applications,the high switching frequency of power converter will result in unnecessary energy losses,which directly affect efficiency.To resolve this issue,a novel finite control set-model predictive control(FCS-MPC)with low switching frequency for three-level neutral point clamped-active front-end converters(NPC-AFEs)is proposed.With this approach,the prediction model of three-level NPC-AFEs is established inα-βreference frame,and the control objective of low average switching frequency is introduced into a cost function.The proposed method not only achieves the desired control performance under low switching frequency,but also performs the efficient operation for the three-level NPC-AFEs.The simulation results are provided to verify the effectiveness of proposed control scheme.展开更多
The four-level active neutral point clamped(ANPC)inverter has become increasingly widely used in the renewable energy indus-try since it offers one more voltage level without increasing the total number of active swit...The four-level active neutral point clamped(ANPC)inverter has become increasingly widely used in the renewable energy indus-try since it offers one more voltage level without increasing the total number of active switches compared to the three-level ANPC inverter.The model predictive current control(MPCC)is a promising control method for multi-level inverters.However,the conven-tional MPCC suffers from high computational complexity and tedious weighting factor tuning in multi-level inverter applications.A low-complexity MPCC without weighting factors for a four-level ANPC inverter is proposed in this paper.The computational burden and voltage vector candidate set are reduced according to the relationship between voltage vector and neutral point voltage balance.The proposed MPCC shows excellent steady-state and dynamics performances while ensuring the neutral point voltage balancing.The efficacy of the proposed MPCC is verified by simulation and experimental results.展开更多
The study examined the inhibitory effect of Atractylodes macrocephala (AM) on the uterine contraction during premature delivery and explored its electrophysiological mechanism by studying the effects of AM on the C...The study examined the inhibitory effect of Atractylodes macrocephala (AM) on the uterine contraction during premature delivery and explored its electrophysiological mechanism by studying the effects of AM on the Ca^2+-activated K^+ currents of pregnant human myometrial smooth muscle cells with or without the treatment with intedeukin-6. Single cells were acutely isolated from pregnant human myometrial smooth muscles. Whole-cell Ca^2+-activated K^+ currents were recorded by using an Axopatchl-D amplifier. The cells were divided into three groups: group A in which AM was added into perfusate, group B, in which interleukin-6 was added into perfusate) and group C in which AM was added into perfusate after addition of interleukin-6. IL-6 10 ng/mL inhibited BKca by 36.9%±13.7% as compared with control (P〈0.01). AM at 2 mg/mL raised BKca by 36.7%±22.6% or 45.2%±13.7% with or without the treatment of IL-6, respectively (P〈0.01). It is concluded that AM was able to enhance the BKca of pregnant human myometrial smooth muscle cells treated or untreated with interleukin-6 and its effect on the BKca IL-treated cells was stronger that its effect on BKca of untreated cells. Our results suggested that AM can help to maintain the membrane potentials and the resting status of pregnant human myometrial smooth muscle cells.展开更多
高速磁浮交通牵引变流器采用24 MVA背靠背三电平有源中点钳位拓扑,其中两台整流器和两台逆变器共用直流母线。该文分析整流侧和逆变侧在不同功率因数下中点电压(neutral point voltage,NPV)偏移机理及不同电压矢量对NPV的具体影响。据此...高速磁浮交通牵引变流器采用24 MVA背靠背三电平有源中点钳位拓扑,其中两台整流器和两台逆变器共用直流母线。该文分析整流侧和逆变侧在不同功率因数下中点电压(neutral point voltage,NPV)偏移机理及不同电压矢量对NPV的具体影响。据此,针对高速磁浮逆变器并联和串联两种模式,建立NPV偏移模型,得到在调制比和功率因数同时变化时NPV的可控区域。为在全速范围保证NPV平衡,提出一种基于平移调制波的协同控制策略。为减轻整流器功率因数和调制比对NPV的影响,采用一种具有相电压半波对称性的载波脉宽调制,并证明其具备NPV自平衡能力。仿真和硬件在环实验表明,所提策略具有NPV恢复到平衡状态所需时间短、可控范围大等优点,可在高速磁浮全速工况下保证NPV平衡。展开更多
基金supported by the Foundation of State Key Laboratory of Wide-Bandgap Semi-conductor Power Electronic Devices(No.2019KF001)National Natural Science Foundation of China(No.51677089)。
文摘When using traditional drive circuits,the enhancement-mode GaN(eGaN)HEMT will be affected by high switching speed characteristics and parasitic parameters leading to worse crosstalk problems.Currently,the existing crosstalk suppression drive circuits often have the disadvantages of increased switching loss,control complexity,and overall electromagnetic interference(EMI).Therefore,this paper combines the driving loop impedance control and the active Miller clamp method to propose an improved active Miller clamp drive circuit.First,the crosstalk mechanism is analyzed,and the crosstalk voltage model is established.Through the crosstalk voltage evaluation platform,the influencing factors are evaluated experimentally.Then,the operating principle of the improved active Miller clamp drive circuit is discussed,and the optimized parameter design method is given.Finally,the effect of the improved active Miller clamp method for suppressing crosstalk is experimentally verified.The crosstalk voltage was suppressed from 3.5 V and-3.5 V to 1 V and-1.3 V,respectively,by the improved circuit.
文摘A simple single-stage AC/DC converter circuit with active clamp is presented. The operation theory and state are analyzed. The experimental results show that the voltage across main switch can be clamped to a certain value,and zero voltage switching (ZVS) can be achieved. The voltage stress and switching loss are both decreased. In range of the whole load,power factors can be always more than 97%,and the highest efficiency can reach 88%.
文摘In medium voltage-high power(MV-HP)applications,the high switching frequency of power converter will result in unnecessary energy losses,which directly affect efficiency.To resolve this issue,a novel finite control set-model predictive control(FCS-MPC)with low switching frequency for three-level neutral point clamped-active front-end converters(NPC-AFEs)is proposed.With this approach,the prediction model of three-level NPC-AFEs is established inα-βreference frame,and the control objective of low average switching frequency is introduced into a cost function.The proposed method not only achieves the desired control performance under low switching frequency,but also performs the efficient operation for the three-level NPC-AFEs.The simulation results are provided to verify the effectiveness of proposed control scheme.
基金supported by the National Key Research and Development Program of China(Grant No.2022YFB4201602)the National Natural Science Foundation of China(Grant No.52002409).
文摘The four-level active neutral point clamped(ANPC)inverter has become increasingly widely used in the renewable energy indus-try since it offers one more voltage level without increasing the total number of active switches compared to the three-level ANPC inverter.The model predictive current control(MPCC)is a promising control method for multi-level inverters.However,the conven-tional MPCC suffers from high computational complexity and tedious weighting factor tuning in multi-level inverter applications.A low-complexity MPCC without weighting factors for a four-level ANPC inverter is proposed in this paper.The computational burden and voltage vector candidate set are reduced according to the relationship between voltage vector and neutral point voltage balance.The proposed MPCC shows excellent steady-state and dynamics performances while ensuring the neutral point voltage balancing.The efficacy of the proposed MPCC is verified by simulation and experimental results.
文摘The study examined the inhibitory effect of Atractylodes macrocephala (AM) on the uterine contraction during premature delivery and explored its electrophysiological mechanism by studying the effects of AM on the Ca^2+-activated K^+ currents of pregnant human myometrial smooth muscle cells with or without the treatment with intedeukin-6. Single cells were acutely isolated from pregnant human myometrial smooth muscles. Whole-cell Ca^2+-activated K^+ currents were recorded by using an Axopatchl-D amplifier. The cells were divided into three groups: group A in which AM was added into perfusate, group B, in which interleukin-6 was added into perfusate) and group C in which AM was added into perfusate after addition of interleukin-6. IL-6 10 ng/mL inhibited BKca by 36.9%±13.7% as compared with control (P〈0.01). AM at 2 mg/mL raised BKca by 36.7%±22.6% or 45.2%±13.7% with or without the treatment of IL-6, respectively (P〈0.01). It is concluded that AM was able to enhance the BKca of pregnant human myometrial smooth muscle cells treated or untreated with interleukin-6 and its effect on the BKca IL-treated cells was stronger that its effect on BKca of untreated cells. Our results suggested that AM can help to maintain the membrane potentials and the resting status of pregnant human myometrial smooth muscle cells.
文摘高速磁浮交通牵引变流器采用24 MVA背靠背三电平有源中点钳位拓扑,其中两台整流器和两台逆变器共用直流母线。该文分析整流侧和逆变侧在不同功率因数下中点电压(neutral point voltage,NPV)偏移机理及不同电压矢量对NPV的具体影响。据此,针对高速磁浮逆变器并联和串联两种模式,建立NPV偏移模型,得到在调制比和功率因数同时变化时NPV的可控区域。为在全速范围保证NPV平衡,提出一种基于平移调制波的协同控制策略。为减轻整流器功率因数和调制比对NPV的影响,采用一种具有相电压半波对称性的载波脉宽调制,并证明其具备NPV自平衡能力。仿真和硬件在环实验表明,所提策略具有NPV恢复到平衡状态所需时间短、可控范围大等优点,可在高速磁浮全速工况下保证NPV平衡。