期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Parameters Optimization and Performance Evaluation of the Tuned Inerter Damper for the Seismic Protection of Adjacent Building Structures
1
作者 Xiaofang Kang Jian Wu +1 位作者 Xinqi Wang Shancheng Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第1期551-593,共43页
In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in ... In order to improve the seismic performance of adjacent buildings,two types of tuned inerter damper(TID)damping systems for adjacent buildings are proposed,which are composed of springs,inerter devices and dampers in serial or in parallel.The dynamic equations of TID adjacent building damping systems were derived,and the H2 norm criterion was used to optimize and adjust them,so that the system had the optimum damping performance under white noise random excitation.Taking TID frequency ratio and damping ratio as optimization parameters,the optimum analytical solutions of the displacement frequency response of the undamped structure under white noise excitation were obtained.The results showed that compared with the classic TMD,TID could obtain a better damping effect in the adjacent buildings.Comparing the TIDs composed of serial or parallel,it was found that the parallel TIDs had more significant advantages in controlling the peak displacement frequency response,while the H2 norm of the displacement frequency response of the damping system under the coupling of serial TID was smaller.Taking the adjacent building composed of two ten-story frame structures as an example,the displacement and energy collection time history analysis of the adjacent building coupled with the optimum design parameter TIDs were carried out.It was found that TID had a better damping effect in the full-time range compared with the classic TMD.This paper also studied the potential power of TID in adjacent buildings,which can be converted into available power resources during earthquakes. 展开更多
关键词 adjacent buildings tuned inerter damper(TID) H2 norm optimization vibration control energy harvesting
下载PDF
Earthquake induced pounding between adjacent buildings considering soil-structure interaction 被引量:3
2
作者 Sadegh Naserkhaki Farah N.A.Abdul Aziz Hassan Pourmohammad 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第3期343-358,共16页
Many closely located adjacent buildings have suffered from pounding during past earthquakes because they vibrated out of phase. Furthermore, buildings are usually constructed on soil; hence, there are interactions bet... Many closely located adjacent buildings have suffered from pounding during past earthquakes because they vibrated out of phase. Furthermore, buildings are usually constructed on soil; hence, there are interactions between the buildings and the underlying soil that should also be considered. This paper examines both the interaction between adjacent buildings due to pounding and the interaction between the buildings through the soil as they affect the buildings' seismic responses. The developed model consists of adjacent shear buildings resting on a discrete soil model and a linear visco- elastic contact force model that connects the buildings during pounding. The seismic responses of' adjacent buildings due to ground accelerations are obtained for two conditions: fixed-based (FB) and structure-soil-structure interaction (SSSI). The results indicate that pounding worsens the buildings' condition because their seismic responses are amplified after pounding. Moreover, the underlying soil negatively impacts the buildings' seismic responses during pounding because the ratio of their seismic response under SSSI conditions with pounding to those without pounding is greater than that of the FB condition. 展开更多
关键词 adjacent buildings underlying soil POUNDING seismic response fixed-based (FB) structure-soil-structureinteraction (SSSI)
下载PDF
Maximum Relative Displacement of Adjacent Buildings During Ground Motions
3
作者 卢明奇 杨庆山 杨娜 《Transactions of Tianjin University》 EI CAS 2012年第5期366-371,共6页
In order to give the reasonable width of seismic gaps to prevent the structural pounding during ground motions,the maximum relative displacement of adjacent structures is studied in this paper.The factors that may hav... In order to give the reasonable width of seismic gaps to prevent the structural pounding during ground motions,the maximum relative displacement of adjacent structures is studied in this paper.The factors that may have effects on the maximum relative displacement are discussed.As for multi-degree-of-freedom(MDOF) systems,they can be equivalent to single-degree-of-freedom(SDOF) systems with the influences of high modes neglected.The results show that the period ratio,height ratio and peak ground acceleration are the main factors that have great effects on the maximum relative displacement of adjacent structures.The maximum relative displacement of MDOF systems can be obtained from calculating the maximum relative displacement of the equivalent SDOF systems. 展开更多
关键词 adjacent buildings maximum relative displacement period ratio height ratio equivalent SDOF system
下载PDF
Optimal Vibration Control of Adjacent Building Structures Interconnected by Viscoelastic Dampers
4
作者 Ming-Yi Liu An-Pei Wang Ming-Yi Chiu 《Journal of Civil Engineering and Architecture》 2017年第5期468-476,共9页
The objective of this paper is to investigate the dynamic characteristics of two adjacent building structures interconnected by viscoelastic dampers under seismic excitations. The computational procedure for an analyt... The objective of this paper is to investigate the dynamic characteristics of two adjacent building structures interconnected by viscoelastic dampers under seismic excitations. The computational procedure for an analytical model including the system model formulation, complex modal analysis and seismic time history analysis is presented for this purpose. A numerical example is also provided to illustrate the analytical model. The complex modal analysis is conducted to determine the optimal damping ratio, the optimal damper stiffness and the optimal damper damping of the viscoelastic dampers for each mode of the system. For the damper stiffness and damping with optimal values, the responses can be categorized into underdamped and critically damped vibrations. Furthermore, compared to the viscous dampers with only the energy dissipation mechanism, the viscoelastic dampers with both the energy dissipation and redistribution mechanisms are more effective for increasing the damping ratio of the system. The seismic time history analysis is conducted to assess the effectiveness of the viscoelastic dampers for vibration control. Based on the optimal damping ratio, the optimal damper stiffness, the optimal damper damping of the viscoelastic dampers for a certain mode of the system, and the viscoelastic dampers can be used to effectively suppress the root-mean-square responses as well as the peak responses of the two adjacent buildings. 展开更多
关键词 adjacent building structure viscoelastic damper complex modal analysis seismic time history analysis.
下载PDF
Numerical study on the seismic response of the underground subway station-surrounding soil mass-ground adjacent building system 被引量:3
5
作者 Guobo WANG Mingzhi YUAN +1 位作者 Xianfeng MA Jun WU 《Frontiers of Earth Science》 SCIE CAS CSCD 2017年第4期424-435,共12页
Ground buildings constructed above metro station have increased very quickly due to the limited land resources in urban areas. In this paper, the seismic response of the Underground subway station-Surrounding soil mas... Ground buildings constructed above metro station have increased very quickly due to the limited land resources in urban areas. In this paper, the seismic response of the Underground subway station-Surrounding soil mass- Ground adjacent buildings (USG) system subjected to various seismic loading is studied through numerical analysis. The numerical model is established in terms of the calculation domain, boundary condition, and contact property between soil and structure based on the real project. The reciprocal influence between subway station and ground adjacent building, and their effects on the dynamic characteristics of surrounding soil mass are also investigated. Through the numerical study, it is found that the impact of underground structure on the dynamic characteristics of the surrounding soil mass depends on its own dimension, and the presence of underground structure has certain impact on the seismic response of ground adjacent building. Due to the presence of underground structure and ground adjacent building, the vertical acceleration generated by the USG system cannot be ignored. The outcomes of this study can provide references for seismic design of structures in the USG system. 展开更多
关键词 underground subway station ground adjacent building seismic response
原文传递
DYNAMIC ANALYSIS OF DAMPER CONNECTED ADJACENT BUILDINGS UNDER EARTHQUAKE 被引量:1
6
作者 何琦 徐幼麟 《Transactions of Tianjin University》 EI CAS 1998年第2期20-25,共6页
A formulation of the multi degree of freedom equations of motion for damper connected adjacent multi story buildings under earthquake excitation is presented.The ground acceleration due to e... A formulation of the multi degree of freedom equations of motion for damper connected adjacent multi story buildings under earthquake excitation is presented.The ground acceleration due to earthquake is regarded as a stochastic process,and a pseudo excitation algorithm in frequency domain is implemented in a computer program to handle the non orthogonal damping properties of the system.The effectiveness of joint dampers is then investigated in terms of the reduction of displacement,acceleration and shear force responses of adjacent buildings. 展开更多
关键词 adjacent buildings damper connection EARTHQUAKE pseudo excitation algorithm
下载PDF
Dynamic responses of two buildings connected by viscoelastic dampers under bidirectional earthquake excitations 被引量:4
7
作者 Z.D. Yang Eddie S.S. Lam 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2014年第1期137-150,共14页
In this study,dynamic responses of two buildings connected by viscoelastic dampers under bidirectional excitations are extensively investigated.The two buildings are a 10-story building and a 16-story building,with th... In this study,dynamic responses of two buildings connected by viscoelastic dampers under bidirectional excitations are extensively investigated.The two buildings are a 10-story building and a 16-story building,with the shorter building on the left.Viscoelastic dampers are installed at all fl oors of the shorter building.Equations of motion are formulated using a fractional derivative model to represent the viscoelastic dampers.Three cases are considered with mass eccentricities at 0,10% and-10% with respect to the dimensions of the buildings.The responses of the buildings are numerically predicted at different damper properties.The simulation results indicated that the maximum horizontal responses of the buildings without eccentricities are signifi cantly mitigated.However,torsional effects are adversely increased.For asymmetric buildings,the effectiveness of the connecting dampers is affected by building eccentricities.As a result,mass eccentricities must be taken into account in damper selection.When compared with vibrations induced by unidirectional excitations,bidirectional excitations can increase the responses of coupled asymmetric buildings.In addition,installing dampers only at the top fl oor of the shorter building may cause a sudden change in lateral stiffness of the taller building.Consequently,the story shear envelopes of the taller building are changed. 展开更多
关键词 bidirectional excitations connecting dampers adjacent buildings fractional derivative
下载PDF
Effect of cantilever soldier pile foundation excavation closing to an existing composite foundation 被引量:4
8
作者 王贵和 杨宇友 《Journal of Central South University》 SCIE EI CAS 2013年第5期1384-1396,共13页
Adjacent high-rise building with CFG pile composite foundation was studied using model test method to investigate stress and displacement of the foundation pile retaining structure, the subsidence and transmogrificati... Adjacent high-rise building with CFG pile composite foundation was studied using model test method to investigate stress and displacement of the foundation pile retaining structure, the subsidence and transmogrification law of the composite foundation. Two different project cases with and without high-rise building adjacent to pile foundation were compared. The relationships of slope pile bending moment, earth pressure, pile top displacement and complex settlement with respect to time were obtained. 1) When there is no adjacent building, the displacement of supporting system caused by excavation is mainly in the horizontal direction; while when the adjacent building exists, the displacement of supporting system will be vertical. 2) When the excavation depth is less than or equal to the adjacent building's composite foundation depth, the force of supporting structure is uniform and has small value, at the same time, the pile strength is in fully use and the foundation is stable; while when the excavation depth is greater than the depth of adjacent building's composite foundation, the results will be opposite. 3) During the excavation process, the adjustment of the composite ground loads on the supporting structure is carried out downward and the force of the supporting structure is reduced through the deformation of the bearing layer. 展开更多
关键词 model test foundation adjacent high-rise building composite foundation
下载PDF
Prediction of sound flanking transmission through two adjacent rooms within a residence building
9
作者 HUANG Xianfeng YANG Zongxiao 《Chinese Journal of Acoustics》 CSCD 2018年第4期409-421,共13页
Flanking transmission has significant effects on the overall sound insulation of two adjacent rooms within a residence building. This study investigates the mechanism of the sound flanking transmission by dividing it ... Flanking transmission has significant effects on the overall sound insulation of two adjacent rooms within a residence building. This study investigates the mechanism of the sound flanking transmission by dividing it into several subsystems with the statistical energy analysis method. The sound energy equations of these subsystems are obtained first, and then,the sound transmissions on each flanking path are predicted and the dominant sound transmission path is determined by solving these equations and calculating the total loss factors of the subsystems and coupling loss factors between subsystems. With respect to a masonry building with heavy-weight homogeneous structure, the results show that:(1) the flanking transmission paths instead of the separating wall may become the dominant ones at low frequencies;(2) all sound transmissions on the flanking paths tend to be consistent at medium and high frequencies, so the sound insulation between two adjacent rooms depends on the direct path of the separating wall;(3) heavy-weight separating walls can be used to reduce the frequency range of the flanking transmission. 展开更多
关键词 Prediction of sound flanking transmission through two adjacent rooms within a residence building SEA
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部