期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Performance of a Solar-Biomass Adsorption Chiller
1
作者 Najeh Ghilen Mohammed El Ganaoui +1 位作者 Slimane Gabsi Riad Benelmir 《Fluid Dynamics & Materials Processing》 EI 2023年第4期1015-1026,共12页
A dynamic model is presented for a chiller working with a composite adsorbent(silica activated carbon/CaCl2)–water pair in a solar-biomass cooling installation.The main objective is determining a link between two pos... A dynamic model is presented for a chiller working with a composite adsorbent(silica activated carbon/CaCl2)–water pair in a solar-biomass cooling installation.The main objective is determining a link between two possible evaporator configurations and the refrigerator’s performances.The two considered evaporators work at different pressure levels.The related time evolution profiles of temperature,pressure and water content are studied.Moreover,the effects of hot water inlet temperature and cooling water inlet temperature on the specific cooling capacity(SCP)and coefficient of performance(COP)are predicted by means of numerical simulations.The results show that an increase in the temperature of hot water and a decrease in the temperature of the cooling water allow an increase in COP and SCP.In particular,for a hot water inlet temperature of 85°C and a cooling water inlet temperature of 40°C,the COP and Qev are 0.67 and 4.3 kW,respectively. 展开更多
关键词 adsorption chiller SOLAR BIOMASS PERFORMANCE
下载PDF
Impact of Numerous Beds Operating Conditions for Enhancing the Performance of a Solar Heat-Supported Adsorption Chiller
2
作者 Nusrat Jahan M. Abdul Hakim Khan K. M. Ariful Kabir 《Journal of Applied Mathematics and Physics》 2023年第11期3651-3665,共15页
Thermal adsorption cooling systems have gained significant attention due to their potential for energy savings and eco-environmental impact. An analytic investigation of the heat transfer inside an adsorption chiller ... Thermal adsorption cooling systems have gained significant attention due to their potential for energy savings and eco-environmental impact. An analytic investigation of the heat transfer inside an adsorption chiller with various bed silica gel-water pairs is presented. A comprehensive model has been designed to accurately predict the correlation between the overall performance of the proposed chiller system and the functional and structural condition of the building. This model takes into account various factors such as temperature, humidity, and air quality to provide a detailed analysis of the system’s efficiency. At least 20 collectors consisting of a 34.4 m area (each) with a full-cycle time of 480 seconds are essential to improper run conditions. It is necessary to adjust the optimum cycle time for optimal performance. During the investigation, the base condition shows that the cooling capacity is 14 kw, 0.6 COPcycle, and 0.35 COPsolar at noon. Also, conduct a thorough investigation into the chiller’s performance under varying cooling water supply temperatures and various chilled water flow rates. 展开更多
关键词 adsorption chillers adsorption Cooling Multiple adsorption Beds Solar Heat
下载PDF
Evaluation of the Characteristic of Adsorption in a Double-Effect Adsorption Chiller with FAM-Z01
3
作者 Takehiro Esaki Noriyuki Kobayashi Takayuki Matsuda 《Journal of Materials Science and Chemical Engineering》 2016年第10期8-19,共12页
Here, we propose a double-effect adsorption chiller with a zeolite adsorbent (FAM-Z01) for utilization of waste heat. The FAM-Z01 adsorbent has the potential to recover waste heat in low temperatures ranging from 353 ... Here, we propose a double-effect adsorption chiller with a zeolite adsorbent (FAM-Z01) for utilization of waste heat. The FAM-Z01 adsorbent has the potential to recover waste heat in low temperatures ranging from 353 to 333 K and shows good potential in the adsorption chiller in terms of the high cooling output. A double-effect adsorption chiller could provide a higher Coefficient Of Performance (COP) than that of a single-effect chiller. In this paper, we developed a measuring method for the amount of adsorption in the first and second adsorber in a double-effect adsorption chiller and measured the adsorption and desorption rate based on the volumetric method. We calculated the COP of the adsorption chiller with the quantity of adsorbent obtained in the experiment. In the experiments, the quantity of adsorbent in the first adsorber was 0.14 g-H<sub>2</sub>O/g-Ads at the pressure 20 kPa and a desorption temperature over 100℃. The amount of adsorbent in the second adsorber was equal to that of the first adsorber. By analyzing the COP with the experimental results, the COP value was calculated to be over 1.0 (–) at any desorption temperature. The COP of the double-effect cycle was higher than that of single-effect cycle. 展开更多
关键词 adsorption chiller DOUBLE-EFFECT FAM-Z01 Coefficient of Performance
下载PDF
The Numerical Comparison of Heat Transfer in a Coated and Fixed Bed of an Adsorption Chiller 被引量:2
4
作者 GRABOWSKA Karolina SOSNOWSKI Marcin +4 位作者 KRZYWANSKI Jaroslaw SZTEKLER Karol KALAWA Wojciech ZYLKA Anna NOWAK Wojciech 《Journal of Thermal Science》 SCIE EI CAS CSCD 2018年第5期421-426,共6页
Ecological adsorption technology is becoming a focus of attention by industry due to the utilization of low grade thermal energy sources for cooling production. It can be a promising part of sustainable development co... Ecological adsorption technology is becoming a focus of attention by industry due to the utilization of low grade thermal energy sources for cooling production. It can be a promising part of sustainable development concept of the global economy. Therefore, research aiming at improving their performance i.e. Coefficient of Performance(COP) by optimizing the construction of sorption beds with a built in heat exchanger system is crucial. The heat transfer characteristics between the bed of porous media(sorbent) and surface of the heat exchanger system determine the heating power of an adsorption chiller. The HP increase can be obtained by heat transfer intensification due to the increase in the thermal conductivity of the sorbent layer in the vicinity of the heat exchanger's surface. The novel modification of the sorbent layer structure is proposed in the paper in order to improve the heat transfer processes in the heat exchanger boundary layer. The analysis of desorption process conditions in the parametric model of a coated and fixed adsorption bed design is presented in the paper. The computational fluid dynamics(CFD) with conjugate heat transfer analysis is used to determine the crucial input parameters(temperature distribution in the sorbent bed) for further analytical calculations. The commercial code Ansys Fluent was used to perform numerical simulations. The developed computational model consisted of three subdomains representing heating water, heat exchanger material(copper) and sorbent(silica gel). The comparison of a novel coated design and a conventional fixed bed is discussed in the paper. The numerical analysis is based on experimental thermal conductivity measurements of the sorbent layer in different configurations, which were performed using Laser Flash Method. 展开更多
关键词 adsorption chiller computational fluid dynamics low grade thermal energy sources coated adsorption bed silica gel thermal conductivity
原文传递
Performance Research of a Micro-CCHP System with Adsorption Chiller 被引量:1
5
作者 孔祥强 王如竹 +1 位作者 李瑛 吴静怡 《Journal of Shanghai Jiaotong university(Science)》 EI 2010年第6期671-675,共5页
This paper describes a new micro-combined cooling, heating and power (CCHP) system, which is especially suitable for domestic and light commercial applications. It mainly consists of a natural gas-fired internal com... This paper describes a new micro-combined cooling, heating and power (CCHP) system, which is especially suitable for domestic and light commercial applications. It mainly consists of a natural gas-fired internal combustion engine, a silica gel-water adsorption chiller and other heat recovery units. In order to study the energy efficiency and economic feasibility, an experimental investigation has been carried out. The experimental system has a rated electricity power of 12 kW, a rated cooling capacity of 9 kW and a rated heating capacity of 28 kW. Evaluation and analysis of the system are discussed in detail. The testing results show that the energy efficiency of the overall system depends on different modes. The overall thermal and electrical efficiency is over 70%. Higher heat load supplied causes higher efficiency of the system. Economic evaluation shows that the micro-CCHP system enjoys a small capital cost and short payback period, which is easily accepted by customers. At current natural gas price of 1.9 RMB/m^3 (nominal condition) and electric price of 0.754 RMB/(kW.h), the total capital cost is only 90 000 RMB with a payback period of 3.21 years. 展开更多
关键词 micro-CCHP gas engine adsorption chiller PERFORMANCE
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部