The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air was...The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air washer. We come to the conclusion that we can change these main factors to achieve different heat and humidity transfer processes and decide processes of heat and humidity transfer of air and water with the initial temperature of spraying water in the air washer. All these results can make things convenient for the air conditioning management.展开更多
The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time de...The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time delay characteristics, presented use feed forward coupling compensation method, to eliminate the coupling effect between temperature and pressure. In this paper, the Elman neural network controller is designed for the first time, and the simulation results show that the response time of Elman neural network controller is shorter, the system is more stable and the overshoot is small.展开更多
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three...To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.展开更多
An important factor for comfort ratio in the indoor environment and affecting human health and well-being is the relative humidity. Studies have shown that about 70% of the staff at Swedish offices, schools and kinder...An important factor for comfort ratio in the indoor environment and affecting human health and well-being is the relative humidity. Studies have shown that about 70% of the staff at Swedish offices, schools and kindergartens experiences that the air is too dry during the winter season. Studies show that the relative humidity in indoor environments influences the incidence of respiratory infections and allergies. Important factors for the air environment indoors is to limit the number of airborne particles, since these are conveyors of both bacteria and viruses, and to keep the humidity at a level above 40% and below 70%, making the survival of viruses and bacteria minimized. Measurement results show that there is significant difference in the relative humidity during the winter season between the mechanically ventilated buildings with relative humidity levels below 10% than in buildings with natural ventilation. An important issue is how human health is affected by during longer periods and during much of the day live in environments with low relative humidity. Several researchers have noted that the incidence of respiratory infections increase during the winter when people are exposed to long periods of low humidity indoors. This means that the consequences of low humidity in the indoor environment should be considered and evaluated in a completely different way than is done today.展开更多
In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVA...In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVAC systems,located at Xi'an city,China.The results showed that there was fungi growth inside the ventilation ducts,fungi contamination was worse than bacteria,and both of them were distributed into occupied space with the air supply ducts.The dominating genera of fungi was found to be Penicillium spp.and Aspergillus spp.,which was respectively 46.1% and 20.7% in settling fungi,and the dominating genera of fungi in dust were Cladosporium spp.and Penicillium spp.,which was 41.8% and 30.1% respectively.It suggests that available measures to improve and control the performance of HVAC-systems such as the maintenance,management and cleaning should be taken to prevent this pollution and to develop strategies to keep this pollution away.展开更多
This paper deals with the application of decouple Control theory to temperature and humidi-ty control in air-conditioning system. The decouple control algorithm for bivariable systems isderived applicablly for air-con...This paper deals with the application of decouple Control theory to temperature and humidi-ty control in air-conditioning system. The decouple control algorithm for bivariable systems isderived applicablly for air-conditioning system. The algorithm is used to design a temperatureand humidity computer control system for the preprocessing chamber of air-conditioning testequipment. The results of the real-time control experiments indicate that the decouple controlalgorithm is feasible, the control quality is improved and high control precision is achieved.展开更多
Characteristics of air pollution in Northeast China(NEC) received less research attention in the past comparing to other heavily polluted regions in China.Spatiotemporal variations of six criteria air pollutants(PM10,...Characteristics of air pollution in Northeast China(NEC) received less research attention in the past comparing to other heavily polluted regions in China.Spatiotemporal variations of six criteria air pollutants(PM10, PM2.5, SO2, NO2, O3 and CO) in Central Liaoning Urban Agglomeration(CLUA) and Harbin-Changchun Urban Agglomeration(HCUA) in NEC Plain were analyzed in this study based on three-year hourly observations of air pollutants and meteorological variables from 2015 to 2017.The results indicated that the annual mean concentrations of air pollutants are generally higher in the middle and southern regions in NEC Plain and lower in the northern region.Megacities such as Shenyang, Harbin and Changchun experience severe air pollution, with a three-year averaged air quality index(AQI) larger than 80, far exceeding the daily AQI standard at the first-level of 50 in China.The annual mean PM and SO2 concentrations decrease most significantly in NEC urban agglomerations from 2015 to 2017, followed by CO and NO2, while O3 shows a slight increasing trend.All the six pollutants exhibit obvious seasonal and diurnal variations, and these variations are dictated by local emission and meteorological conditions.PM2.5 and O3 concentrations in NEC urban agglomerations strongly depend on wind conditions.High O3 concentrations at different cities usually occur in presence of strong winds but are independent on wind direction(WD), while high PM2.5 is usually accompanied by weak winds and poor dispersion condition, and sometimes also occur when the northerly or southerly winds are strong.Regional transport of air pollutants between NEC urban agglomerations is common.A severe haze event on November 1–4, 2017 is examined to demonstrate the role of regional transport on pollution.展开更多
This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizin...This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizing monthly energy consumption data of the entire year as the analysis object,this paper identifies data distribution,verifies distribution characteristics and analyzes distribution probability density for the issue of running time distribution ratio of air conditioning system in part load zones in the whole operation period,thus providing a basic calculation basis for an overall analysis of energy efficiency of air conditioning system. In view of the general survey of public building energy consumption carried by the government of Chongqing,this paper takes the governmental office building as an example,the part load ratio coefficient corresponding to practical running of air conditioning system of governmental office building in Chongqing is obtained by utilizing the above probability analysis and the solving method of probability density function. By utilizing the ratio coefficient obtained using this method,the part load coefficient with any running ratio of air conditioning system can be obtained according to the requirement of analysis,which can be used in any load ratio for analyzing running energy efficiency of air conditioning system.展开更多
When water penetrates into soil,interstitial air can become trapped by the infiltrating water.Neglecting the effect of air ventilation could cause deviations in the predicted pore water pressure and the associated eff...When water penetrates into soil,interstitial air can become trapped by the infiltrating water.Neglecting the effect of air ventilation could cause deviations in the predicted pore water pressure and the associated effective stress.This study aims at the effect of air ventilation on the coupled hydro-mechanical responses in homogeneous soil during infiltration.A schematic concept of infiltration conditions(open-and closed-valve)in homogeneous soil is proposed for investigating their impacts on the pore water pressure and effective stress.Experiments of vertical soil column filled with Ottawa sand(ASTM C77820/30)were designed for two types of air ventilation(namely,open and closed infiltration).The evolution of pore water pressure at the cylinder bottom was recorded,and served as a benchmark problem for evaluating the coupled hydro-mechanical response.Coding with the commercial software,GeoStudio,was employed for the dynamic behaviors of pore-water and-air pressures as well as the evolving effective stress.It was found in both the experiments and numerical investigations that the infiltration condition plays a crucial role for the ascending rate of pore water pressure as well as the associated effective stress.These results illustrate the inevitable impacts of the air ventilation conditions on the mechanical properties of the soil during infiltration.展开更多
Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of...Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of the depletion of the Earth’s ozone layer. Consequently, the world’s industrial nations are taking concerted action to decrease the use of CFCs, calling for attention of the engineers and designers involved in the manufacture and application of refrigeration systems for air conditioning. This paper analyses the available alternatives of CFCs in the industry and examines the problem found in process application.展开更多
The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different ...The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD).展开更多
A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. ...A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.展开更多
The thesis has changed the heat and moisture exchange curves of Swiss Luwa air washer into double efficiency formulas which are widely used in our country with a computer, and also worked out the regression formula of...The thesis has changed the heat and moisture exchange curves of Swiss Luwa air washer into double efficiency formulas which are widely used in our country with a computer, and also worked out the regression formula of heat transfer efficiency(X). This has created favourable condition for us to use computer in our calculation of Luwa air washer.展开更多
This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy sys...This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy systems for buildings. The match of solar collector types and chiller types have been discussed and suggested.展开更多
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange...The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.展开更多
Reducing heat accumulation within vehicles and ensuring appropriate vehicular temperature levels can lead to enhanced vehicle fuel economy,range,reliability,longevity,passenger comfort,and safety.Advancements in vehic...Reducing heat accumulation within vehicles and ensuring appropriate vehicular temperature levels can lead to enhanced vehicle fuel economy,range,reliability,longevity,passenger comfort,and safety.Advancements in vehicle thermal management remain key as new technologies,consumer demand,societal concerns,and government regulations emerge and evolve.This study summarizes several recent advances in vehicle thermal management technology and modeling,with a focus on three key areas:the cabin,electronics,and exterior components of vehicles.Cabin-related topics covered include methods for reducing thermal loads and improving heating,ventilation,and air-conditioning(HVAC)systems;and advancements in window glazing/tinting and vehicle surface treatments.For the thermal management of electronics,including batteries and insulated-gate bipolar transistors(IGBTs),active and passive cooling methods that employ heat pipes,heat sinks,jet impingement,forced convection,and phase-change materials are discussed.Finally,efforts to model and enhance the heat transfer of exterior vehicular components are reviewed while considering drag/friction forces and environmental effects.Despite advances in the field of vehicle thermal management,challenges still exist;this article provides a broad summary of the major issues,with recommendations for further study.展开更多
Indoor air environment includes indoor thermal environment and air quality, and a reasonable ventilation provides guarantee for a good indoor environment. A numerical study of the indoor environment in different venti...Indoor air environment includes indoor thermal environment and air quality, and a reasonable ventilation provides guarantee for a good indoor environment. A numerical study of the indoor environment in different ventilation is presented in this paper. The External Energy Saving Lab of the WenYuan Building was selected for this purpose, and its indoor air quality and thermal performance in the typical summer climate were simulated. For the numerical simulation, the techniques of Fluent Air-pak was adopted to establish the physical and numerical model of lab. A attention is given to the velocity field and the distribution of pollutant concentration, followed by a discussion of two ventilation modes (displacement ventilation and up-in and up-out ventilation). By comparison, it is found that the Displacement ventilation in improving indoor air quality is obviously superior to the traditional up-in and up-out ventilation.展开更多
文摘The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air washer. We come to the conclusion that we can change these main factors to achieve different heat and humidity transfer processes and decide processes of heat and humidity transfer of air and water with the initial temperature of spraying water in the air washer. All these results can make things convenient for the air conditioning management.
文摘The stable operation of the central air conditioning water system always is a major difficulty for the control profession. Paper focus on the water system with multi variable, strong coupling, nonlinear, large time delay characteristics, presented use feed forward coupling compensation method, to eliminate the coupling effect between temperature and pressure. In this paper, the Elman neural network controller is designed for the first time, and the simulation results show that the response time of Elman neural network controller is shorter, the system is more stable and the overshoot is small.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProjects(2006BAJ02A09,2006BAJ02A13-4) supported by the National Key Technologies R & D Program of China
文摘To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.
文摘An important factor for comfort ratio in the indoor environment and affecting human health and well-being is the relative humidity. Studies have shown that about 70% of the staff at Swedish offices, schools and kindergartens experiences that the air is too dry during the winter season. Studies show that the relative humidity in indoor environments influences the incidence of respiratory infections and allergies. Important factors for the air environment indoors is to limit the number of airborne particles, since these are conveyors of both bacteria and viruses, and to keep the humidity at a level above 40% and below 70%, making the survival of viruses and bacteria minimized. Measurement results show that there is significant difference in the relative humidity during the winter season between the mechanically ventilated buildings with relative humidity levels below 10% than in buildings with natural ventilation. An important issue is how human health is affected by during longer periods and during much of the day live in environments with low relative humidity. Several researchers have noted that the incidence of respiratory infections increase during the winter when people are exposed to long periods of low humidity indoors. This means that the consequences of low humidity in the indoor environment should be considered and evaluated in a completely different way than is done today.
基金Supported by the National Natural Science Foundation of China(50878177)the Rearch Fund for the Doctoral Program of Higher Education
文摘In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVAC systems,located at Xi'an city,China.The results showed that there was fungi growth inside the ventilation ducts,fungi contamination was worse than bacteria,and both of them were distributed into occupied space with the air supply ducts.The dominating genera of fungi was found to be Penicillium spp.and Aspergillus spp.,which was respectively 46.1% and 20.7% in settling fungi,and the dominating genera of fungi in dust were Cladosporium spp.and Penicillium spp.,which was 41.8% and 30.1% respectively.It suggests that available measures to improve and control the performance of HVAC-systems such as the maintenance,management and cleaning should be taken to prevent this pollution and to develop strategies to keep this pollution away.
文摘This paper deals with the application of decouple Control theory to temperature and humidi-ty control in air-conditioning system. The decouple control algorithm for bivariable systems isderived applicablly for air-conditioning system. The algorithm is used to design a temperatureand humidity computer control system for the preprocessing chamber of air-conditioning testequipment. The results of the real-time control experiments indicate that the decouple controlalgorithm is feasible, the control quality is improved and high control precision is achieved.
基金Under the auspices of National Key Research and Development Program of China(No.2017YFC0212301,2016YFC0203304)Basic Research Funds of Central Public Welfare Research Institutes(No.2018SYIAEZD4)+3 种基金Program of Liaoning Meteorological Office(No.201904,D201603)Key Program of National Natural Science Foundation of China(No.41730647)Program of Laboratory of Atmospheric Chemistry,China Meteorological Administration(No.2017B02)Key Program of Natural Science Foundation of Liaoning Province(No.20170520359)
文摘Characteristics of air pollution in Northeast China(NEC) received less research attention in the past comparing to other heavily polluted regions in China.Spatiotemporal variations of six criteria air pollutants(PM10, PM2.5, SO2, NO2, O3 and CO) in Central Liaoning Urban Agglomeration(CLUA) and Harbin-Changchun Urban Agglomeration(HCUA) in NEC Plain were analyzed in this study based on three-year hourly observations of air pollutants and meteorological variables from 2015 to 2017.The results indicated that the annual mean concentrations of air pollutants are generally higher in the middle and southern regions in NEC Plain and lower in the northern region.Megacities such as Shenyang, Harbin and Changchun experience severe air pollution, with a three-year averaged air quality index(AQI) larger than 80, far exceeding the daily AQI standard at the first-level of 50 in China.The annual mean PM and SO2 concentrations decrease most significantly in NEC urban agglomerations from 2015 to 2017, followed by CO and NO2, while O3 shows a slight increasing trend.All the six pollutants exhibit obvious seasonal and diurnal variations, and these variations are dictated by local emission and meteorological conditions.PM2.5 and O3 concentrations in NEC urban agglomerations strongly depend on wind conditions.High O3 concentrations at different cities usually occur in presence of strong winds but are independent on wind direction(WD), while high PM2.5 is usually accompanied by weak winds and poor dispersion condition, and sometimes also occur when the northerly or southerly winds are strong.Regional transport of air pollutants between NEC urban agglomerations is common.A severe haze event on November 1–4, 2017 is examined to demonstrate the role of regional transport on pollution.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProjects(2006BAJ02A09,2006BAJ02A13-4) supported by the National Key Technologies R & D Program of ChinaProject(CSTC,2008AB7110) supported by the Key Technologies R & D Programme of Chongqing,China
文摘This paper presents a method to acquire runtime distribution ratio of building air conditioning system under part load condition (part load coefficient of system) through practical energy consumption data. By utilizing monthly energy consumption data of the entire year as the analysis object,this paper identifies data distribution,verifies distribution characteristics and analyzes distribution probability density for the issue of running time distribution ratio of air conditioning system in part load zones in the whole operation period,thus providing a basic calculation basis for an overall analysis of energy efficiency of air conditioning system. In view of the general survey of public building energy consumption carried by the government of Chongqing,this paper takes the governmental office building as an example,the part load ratio coefficient corresponding to practical running of air conditioning system of governmental office building in Chongqing is obtained by utilizing the above probability analysis and the solving method of probability density function. By utilizing the ratio coefficient obtained using this method,the part load coefficient with any running ratio of air conditioning system can be obtained according to the requirement of analysis,which can be used in any load ratio for analyzing running energy efficiency of air conditioning system.
文摘When water penetrates into soil,interstitial air can become trapped by the infiltrating water.Neglecting the effect of air ventilation could cause deviations in the predicted pore water pressure and the associated effective stress.This study aims at the effect of air ventilation on the coupled hydro-mechanical responses in homogeneous soil during infiltration.A schematic concept of infiltration conditions(open-and closed-valve)in homogeneous soil is proposed for investigating their impacts on the pore water pressure and effective stress.Experiments of vertical soil column filled with Ottawa sand(ASTM C77820/30)were designed for two types of air ventilation(namely,open and closed infiltration).The evolution of pore water pressure at the cylinder bottom was recorded,and served as a benchmark problem for evaluating the coupled hydro-mechanical response.Coding with the commercial software,GeoStudio,was employed for the dynamic behaviors of pore-water and-air pressures as well as the evolving effective stress.It was found in both the experiments and numerical investigations that the infiltration condition plays a crucial role for the ascending rate of pore water pressure as well as the associated effective stress.These results illustrate the inevitable impacts of the air ventilation conditions on the mechanical properties of the soil during infiltration.
文摘Until recently, CFC-11 and CFC-12 were the most widely used refrigerant gases in air conditioning systems. Environmental agencies around the world, however, have specifical concern for these gases as a direct cause of the depletion of the Earth’s ozone layer. Consequently, the world’s industrial nations are taking concerted action to decrease the use of CFCs, calling for attention of the engineers and designers involved in the manufacture and application of refrigeration systems for air conditioning. This paper analyses the available alternatives of CFCs in the industry and examines the problem found in process application.
文摘The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD).
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProjects(2006BAJ02A09+1 种基金2006BAJ02A13-4) supported by the National Key Technologies R&D ProgramProject(2006BAJ01A06-3) supported by the Key R & D Program during the Eleventh Five-Year Plan Period,China
文摘A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly.
文摘The thesis has changed the heat and moisture exchange curves of Swiss Luwa air washer into double efficiency formulas which are widely used in our country with a computer, and also worked out the regression formula of heat transfer efficiency(X). This has created favourable condition for us to use computer in our calculation of Luwa air washer.
基金support of this research from Nation-al Key Technologies R&D Program ( No.2006BAA04B03) is gratefully acknowledged.
文摘This paper mainly shows the demonstration of solar air conditioning systems in China, which includes LiBr-H2O absorption cooling, silica gel-water adsorption chiller, desiccant cooling and hybrid integrated energy systems for buildings. The match of solar collector types and chiller types have been discussed and suggested.
文摘The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated.
基金sponsored by the US Government under Other Transaction number W15QKN-13-9-0001 between the Consortium for Energy, Environment and Demilitarization, and the Government, with funding provided by the US Army Engineer Research & Development Center
文摘Reducing heat accumulation within vehicles and ensuring appropriate vehicular temperature levels can lead to enhanced vehicle fuel economy,range,reliability,longevity,passenger comfort,and safety.Advancements in vehicle thermal management remain key as new technologies,consumer demand,societal concerns,and government regulations emerge and evolve.This study summarizes several recent advances in vehicle thermal management technology and modeling,with a focus on three key areas:the cabin,electronics,and exterior components of vehicles.Cabin-related topics covered include methods for reducing thermal loads and improving heating,ventilation,and air-conditioning(HVAC)systems;and advancements in window glazing/tinting and vehicle surface treatments.For the thermal management of electronics,including batteries and insulated-gate bipolar transistors(IGBTs),active and passive cooling methods that employ heat pipes,heat sinks,jet impingement,forced convection,and phase-change materials are discussed.Finally,efforts to model and enhance the heat transfer of exterior vehicular components are reviewed while considering drag/friction forces and environmental effects.Despite advances in the field of vehicle thermal management,challenges still exist;this article provides a broad summary of the major issues,with recommendations for further study.
文摘Indoor air environment includes indoor thermal environment and air quality, and a reasonable ventilation provides guarantee for a good indoor environment. A numerical study of the indoor environment in different ventilation is presented in this paper. The External Energy Saving Lab of the WenYuan Building was selected for this purpose, and its indoor air quality and thermal performance in the typical summer climate were simulated. For the numerical simulation, the techniques of Fluent Air-pak was adopted to establish the physical and numerical model of lab. A attention is given to the velocity field and the distribution of pollutant concentration, followed by a discussion of two ventilation modes (displacement ventilation and up-in and up-out ventilation). By comparison, it is found that the Displacement ventilation in improving indoor air quality is obviously superior to the traditional up-in and up-out ventilation.