In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat trans...In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%.展开更多
This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilizat...This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period.展开更多
The heat transfer and mass transfer fin efficiencies were analyzed numerically to show that popular models for heat transfer fm efficiency for circular fins are not always reasonable. The numerical results show that t...The heat transfer and mass transfer fin efficiencies were analyzed numerically to show that popular models for heat transfer fm efficiency for circular fins are not always reasonable. The numerical results show that the effective heat transfer area of a circular fin increases several times faster than that of a straight fin for the same tube radius. Then, a simple but accurate heat transfer fin efficiency model was developed and verified by numerical results for a wide range of fin designs. This model predicts the heat transfer fin efficiency with absolute errors of less than 1%. The heat transfer and mass transfer fin efficiencies were found to be quite different for typical air flow with low relative humidity. Thus, these two fin efficiencies should not be assumed to be equal and a mass transfer fin efficiency model was developed, based on the heat transfer fin efficiency model. These heat transfer and mass transfer fin efficiencies are very useful for more accurate prediction for a wide range of practical applications.展开更多
基金supported by the National Key R&D Program of China(No. 2020YFB1901405)
文摘In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%.
文摘This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period.
基金supported by the National Basic Research Program of China("973"Project)(Grant No.2011CB706904)Beijing Natural Science Foundation(Grant No.3071001)
文摘The heat transfer and mass transfer fin efficiencies were analyzed numerically to show that popular models for heat transfer fm efficiency for circular fins are not always reasonable. The numerical results show that the effective heat transfer area of a circular fin increases several times faster than that of a straight fin for the same tube radius. Then, a simple but accurate heat transfer fin efficiency model was developed and verified by numerical results for a wide range of fin designs. This model predicts the heat transfer fin efficiency with absolute errors of less than 1%. The heat transfer and mass transfer fin efficiencies were found to be quite different for typical air flow with low relative humidity. Thus, these two fin efficiencies should not be assumed to be equal and a mass transfer fin efficiency model was developed, based on the heat transfer fin efficiency model. These heat transfer and mass transfer fin efficiencies are very useful for more accurate prediction for a wide range of practical applications.