DISPLACEMENT CONTROL AND KINETIC ANALYSIS OF A NOVEL VARIABLE DISPLACEMENT COMPRESSOR FOR AUTOMOTIVE AIR CONDITIONER 被引量:7
1
作者 Yuan Xiaomei,Chen Zhijiu (Institute of Refrigeration and Cryogenics Engineering, Shanghai Jiaotong University) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2001年第4期325-329,共5页
A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of... A novel variable displacement compressor (VDC) for automotive air conditioner (AAC) is introduced, which inherits the advantages of common wobble plate type VDC. It has fewer parts and makes less noise, and instead of pneumatic valve the displacement is controlled by electronic control valve. In order to know the control mechanism well and get a good control effect, a mathematical model for the variable displacement mechanism is developed according to the geometrical and kinematical information of the compressor. Using the model, the effect of relevant parameters on variable displace control is estimated. It is helpful to make the optimum decision in the flow control of AAC. As the novel displacement control device, the structure and control rule of electronic control valve is introduced. It can get better effect than the conventional pneumatic valves. And by using this new electronic control device, the optimum systemic control of AAC is available. 展开更多
关键词 Displacement control Kinetic analysis Automotive air conditioner (AAC) Variable displacement compressor(VDC)
下载PDF
A Study on the Reduction of the Aerodynamic Drag and Noise Generated By the Roof Air Conditioner of High-Speed Trains 被引量:5
2
作者 Jiali Liu Mengge Yu +1 位作者 Dawei Chen Zhigang Yang 《Fluid Dynamics & Materials Processing》 EI 2020年第1期21-30,共10页
In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large e... In order to investigate how the aerodynamic drag and noise produced by the roof air conditioner of a high-speed train can be reduced,the related unsteady flow in the near-field was computed using the method of large eddy simulation.In this way,the aerodynamic source for noise generation has initially been determined.Then,the far-field aerodynamic noise has been computed in the framework of the Lighthill’s acoustics analogy theory.The propulsion height and flow-guide angle of the roof air conditioner were set as the design variables.According to the computational results,a lower propulsion height or flow-guide angle is beneficial in terms of aerodynamic drag and noise mitigation.However,compared to the design scheme with propulsion height of 0mm,the aerodynamic drag coefficient of the configuration with propulsion height of 190mm and flow-guide angle of 30°is slightly larger,while the aerodynamic noise is obviously reduced.Thus,from the viewpoint of the aerodynamic drag and noise,the design scheme with propulsion height of 190 mm and flow-guide angle of 30°is the optimal configuration in the range of conditions examined in the present work. 展开更多
关键词 Aerodynamic drag aerodynamic noise roof air conditioner large eddy simulation acoustics analogy theory
下载PDF
Girth welding system for vortex type refrigeration compressor of air conditioner 被引量:1
3
作者 刘小文 马彩霞 +1 位作者 杨思乾 胡记生 《China Welding》 EI CAS 2006年第1期57-60,共4页
According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both uprig... According to the requirements of welding process for vortex type compressor of air conditioner manufactured in product line, a special girth welding machine with PLC as control core was developed, which had both upright and 45 ° incline service positions. And some key technologies were researched, such as structural design of machine body, reliable conduction of rotary weldments and quality control of welding process and so on. The experimental results showed that this machine could satisfy the requirements of welding quality and girth welding technology, results also proved the machine was a high-effwiency and low-cost automatic welding device. 展开更多
关键词 air conditioner compressor girth welding welding machine
下载PDF
A Comparative Study on the Performance and Environmental Characteristics of Alternatives to R22 in Residential Air Conditioners for Tunisian Market 被引量:1
4
作者 M.C. Zaghdoudi S. Maalej +1 位作者 Y. Saad M. Bouchaala 《Journal of Environmental Science and Engineering》 2010年第12期37-56,共20页
This paper presents the simulation results of a 9000 BTU/h air conditioner with some selected fluids that have been assessed for their suitability as alternatives to R22 for air conditioners. Only those refrigerants w... This paper presents the simulation results of a 9000 BTU/h air conditioner with some selected fluids that have been assessed for their suitability as alternatives to R22 for air conditioners. Only those refrigerants with zero Ozone Depletion Potential (ODP) are considered. The performances of 11 refrigerants were comparatively studied using the simulation software NIST Cycle_D. R134a, R290, R600, R404A, R407A, R407B, R407C, 407D, R410A, R410B, and R417A are considered in this study. The thermal performances, which are obtained with R 134a and R290, are very close to those of R22. The power consumptions of the unit operating with R404A, R407C, and R410A are higher in the range 22-31% with respect of R22. For the units operating with 407A, R407B, R407D, R407E, and R410B, the electric consumptions are higher in the range 10-23%. For R600, the power consumptions are in the range 6-8%. For all the fluids, the COP is lower by 7-24% than R22, except for R600 for which the COP is higher by 7-9%, and R134a and R290 which exhibit the same COP as R22. When considering the thermal and environmental parameters, R290 is identified as the best candidate for R22, provided the safety aspects of using R290 are addressed. 展开更多
关键词 air conditioner REFRIGERANT REPLACEMENT simulation PERFORMANCE COP
下载PDF
Water, land, and energy use efficiencies and financial evaluation of air conditioner cooled greenhouses based on field experiments
5
作者 Ibtihal AL-MANTHRIA Abdulrahim M AL-ISMAILIA +2 位作者 Hemesiri KOTAGAMAB Mumtaz KHANC L H Janitha JEEWANTHAD 《Journal of Arid Land》 SCIE CSCD 2021年第4期375-387,共13页
High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial asp... High temperature and humidity can be controlled in greenhouses by using mechanical refrigeration cooling system such as air conditioner(AC)in warm and humid regions.This study aims to evaluate the techno-financial aspects of the AC-cooled greenhouse as compared to the evaporative cooled(EV-cooled)greenhouse in winter and summer seasons.Two quonset single-span prototype greenhouses were built in the Agriculture Experiment Station of Sultan Qaboos University,Oman,with dimensions of 6.0 m long and 3.0 m wide.The AC-cooled greenhouse was covered by a rockwool insulated polyethylene plastic sheet and light emitting diodes(LED)lights were used as a source of light,while the EV-cooled greenhouse was covered by a transparent polyethylene sheet and sunlight was used as light source.Three cultivars of high-value lettuce were grown for experimentation.To evaluate the technical efficiency of greenhouse performance,we conducted measures on land use efficiency(LUE),water use efficiency(WUE),gross water use efficiency(GWUE)and energy use efficiency(EUE).Financial analysis was conducted to compare the profitability of both greenhouses.The results showed that the LUE in winter were 10.10 and 14.50 kg/m^(2) for the AC-and EV-cooled greenhouses,respectively.However,the values reduced near to 6.80 kg/m^(2) in both greenhouses in summer.The WUE of the AC-cooled greenhouse was higher than that of the EV-cooled greenhouse by 3.8%in winter and 26.8%in summer.The GWUE was used to measure the total yield to the total greenhouse water consumption including irrigation and cooling water;it was higher in the AC-cooled greenhouse than in the EV-cooled greenhouse in both summer and winter seasons by almost 98.0%–99.4%.The EUE in the EV-cooled greenhouse was higher in both seasons.Financial analysis showed that in winter,gross return,net return and benefit-to-cost ratio were better in the EVcooled greenhouse,while in summer,those were higher in the AC-cooled greenhouse.The values of internal rate of return in the AC-and EV-cooled greenhouses were 63.4%and 129.3%,respectively.In both greenhouses,lettuce investment was highly sensitive to changes in price,yield and energy cost.The financial performance of the AC-cooled greenhouse in summer was better than that of the EV-cooled greenhouse and the pattern was opposite in winter.Finally,more studies on the optimum LED light intensity for any particular crop have to be conducted over different growing seasons in order to enhance the yield quantity and quality of crop. 展开更多
关键词 land use efficiency energy use efficiency water use efficiency gross water use efficiency financial evaluation air conditioner cooled greenhouse evaporative cooled greenhouse
下载PDF
Optimal Scheduling of Air Conditioners for Energy Efficiency
6
作者 K.Venkatesan Uppu Ramachandraiah 《Journal of Electronic Science and Technology》 CAS CSCD 2018年第2期110-122,共13页
Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy... Energy saving is one of the most important research hotspots, by which operational expenditure and CO2 emission can be reduced. Optimal cooling capacity scheduling in addition to temperature control can improve energy efficiency. The main contribution of this work is modeling the telecommunication building for the fabric cooling load to schedule the operation of air conditioners. The time series data of the fabric cooling load of the building envelope is taken by simulation by using Energy Plus, Building Control Virtual Test Bed (BCVTB), and Matlab. This pre-computed data and other internal thermal loads are used for scheduling in air conditioners. Energy savings obtained for the whole year are about 4% to 6% by simulation and the field study, respectively. 展开更多
关键词 Building fabric cooling load energy balanced air conditioning energy efficiency scheduling of air conditioners
下载PDF
Guangdong Rowa Air Conditioner Co, Ltd.
7
《China's Foreign Trade》 2002年第6期31-31,共1页
THE COMPANYGuangdong Rowa Air Conditioner Company Limited, a subsidiary of Great Wall Cybertech Limited, is a leading air conditioner manufacturer in the People’s Republic of China. It was formerly the Guangdong Sann... THE COMPANYGuangdong Rowa Air Conditioner Company Limited, a subsidiary of Great Wall Cybertech Limited, is a leading air conditioner manufacturer in the People’s Republic of China. It was formerly the Guangdong Sanning Air-Conditioner Co., Ltd. 展开更多
关键词 OT OI Guangdong Rowa air conditioner Co LTD
下载PDF
Window Air Conditioners Transition and Restriction in Saudi Arabia
8
作者 Essam Al Ammar Abdulhakim Bin Dayil 《Journal of Power and Energy Engineering》 2022年第5期1-21,共21页
This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spr... This paper will provide a proposed solution for saving energy consumption due to residential air conditioners by reducing the window air conditioners type which is the most consumed energy and has a big percent of spreading inside KSA than the split type, also it will discuss some restrictions for trading and manufacturing of air conditioner devices inside KSA besides some restrictions on market and buildings to achieve the objective of reducing the consumption of energy which become a big trend in kingdom vision 2030. The results of this suggesting solution will help the decision-makers to start its plan for execution as it has a big difference between using window type from 2022 till 2030 and if we stop its sales and replace by an efficient one of split AC type in energy consumption in addition to CO<sub>2</sub> emission reduction and decreasing of energy cost, hence our kingdom can save petroleum raw materials and keeping the environment to become clean from pollutants so that these resources are delivered to successive generations correct and clean as we received them from those before us. 展开更多
关键词 air conditioners (AC) Terawatt-Hour (TWh) Saudi Standards Metrology and Quality Organization (SASO) Energy-Efficiency Ratio (EER) High Efficiency air Conditioning (HEAC) Carbon Dioxide (CO2) Heating Ventilation and air Conditioning (HVAC) Saudi Building Code (SBC) Saudi Energy Efficiency Center (SEEC)
下载PDF
The Energy Efficiency Label to Be Attached on the Air Conditioner and Refrigerator
9
《China Standardization》 2005年第2期5-5,共1页
It is reported that from March 1 st, 2005, the energy efficiency label will be attached on the household refrigerators and air conditioners in China.
关键词 BE The Energy Efficiency Label to Be Attached on the air conditioner and Refrigerator
下载PDF
Jirong Air Conditioners
10
《China's Foreign Trade》 1997年第11期37-37,共1页
Various kinds of cabinet air conditioners,roof top air conditioners, cool-water set of air conditioners, and air treatment apparatuses,produced by Guangdong Jirong Air Conditioner Equipment Corporation, using world na... Various kinds of cabinet air conditioners,roof top air conditioners, cool-water set of air conditioners, and air treatment apparatuses,produced by Guangdong Jirong Air Conditioner Equipment Corporation, using world namebrand compressors, blower fans, computers,and control devices and other materials imported from abroad, are widely used in industrial and civil projects. The quality of the products is reliable, with low noise, easy operation, and high precision for control. Their main quotas for specifications are up to the international advanced standards. The output of Jirong cabinet and roof-top air conditioners is the leader in the country. The variety of cabinet conditioners includes water-cool and air-coon ones 展开更多
关键词 Jirong air conditioners
下载PDF
Estimation of Vapor Quality at Compressor Suction of Air Conditioner
11
作者 Kazuhiro Endoh 《Journal of Energy and Power Engineering》 2015年第4期367-374,共8页
To evaluate performance and reliability of an air conditioner, the states of its refrigerant in the refrigeration cycle need to be understood. Since the isentropic exponent of the next-generation refrigerant R32 is la... To evaluate performance and reliability of an air conditioner, the states of its refrigerant in the refrigeration cycle need to be understood. Since the isentropic exponent of the next-generation refrigerant R32 is larger than that of conventional refrigerant R410A, the compressor discharge temperature of R32 is higher than that of R410A. When a wet refrigerant is entered into a compressor suction line to decrease the discharge temperature, it is generally difficult to estimate the vapor quality at the suction. This paper describes a method that estimates a vapor quality at the compressor suction by applying energy balances on the compressor with the values of suction pressure, discharge pressure, discharge temperature, etc. In the air conditioner test, the vapor qualities at the compressor suction estimated with this method agreed well with those estimated with the conventional method by measuring liquid and vapor flow-rates. Moreover, this paper derived a relational expression for estimating a compressor suction state from a discharge state and discusses the characteristics of the coefficients in the expression calculated from the test results. 展开更多
关键词 air conditioner COMPRESSOR wet refrigerant vapor quality R32.
下载PDF
Three National Compulsory Standards on Energy Efficiency of Air Conditioners Approved
12
《China Standardization》 2004年第6期12-13,共2页
关键词 Three National Compulsory Standards on Energy Efficiency of air conditioners Approved
下载PDF
An Investigation on China's Air Conditioner Industry
13
作者 Yang Wei 《China's Foreign Trade》 2000年第10期34-34,共1页
关键词 An Investigation on China’s air conditioner Industry
下载PDF
Critical assessment of R410A alternatives for mini-split air conditioners in the Egyptian market
14
作者 Omar M.Zaki Omar Abdelaziz 《Energy and Built Environment》 2024年第3期426-445,共20页
In this study,the potential implementation of three different low-GWP refrigerants(R32,R452B,and R454B)as replacements for R410A was investigated.The study was performed using a simulation tool developed by the author... In this study,the potential implementation of three different low-GWP refrigerants(R32,R452B,and R454B)as replacements for R410A was investigated.The study was performed using a simulation tool developed by the authors called RACHP-Lab,which is a vapor compression system simulation tool developed based on physics-based simulation for typical mini-split air conditioners.The simulation study was carried out and validated using experimental performance data of 10 different air conditioning units available in the Egyptian market.The units included fixed-speed or variable-speed compressors and operated in cooling or heating modes.Drop-in replace-ment with the new refrigerants was carried out.For R32,the capacity increased between 4.9%and 13%for cooling cases,and 6.3%and 12.4%for heating cases.However,COP did not improve in all cases.For R452B and R454B with direct replacement,the capacity nearly remained the same,with an increase of COP between 1.6%and 8.0%.Soft optimization was also conducted on cooling cases where compressor suction superheat,condenser subcooling,and compressor volumetric speed were optimized to maximize COP while maintaining the original capacity of R410A.R32 showed an improvement of COP over R410A between 4.6%and 15.5%,while for R452B and R454B between 2.2%and 13.2%. 展开更多
关键词 air conditioner Heat pump Alternative refrigerants Vapor compression cycle modeling
原文传递
Remote Control of Unitary Air Conditioner Based on Manufacturing Message Specification
15
作者 黄伟红 陈圣权 吴介一 《Journal of Southeast University(English Edition)》 EI CAS 1999年第2期43-48,共6页
Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step ... Traditional air conditioner used to be in local control mode. However, with the development of modern information technology, the control of air conditioner will have to support many more functions. As a first step in such a development, we have implemented a remote monitoring system of unitary air conditioners, using the manufacturing message specification (MMS). MMS is an OSI application protocol designed for the remote control and monitoring of real devices. The functions supported are those that an operator would do normally at the console of the unitary air conditioner. Due to the accomplishment of UMCS (Unitary air conditioner MMS Control System), there will be a leap of the application of MMS and the control technology of unitary air conditioner. 展开更多
关键词 remote control manufacturing message specification unitary air conditioner
下载PDF
Indoor Environment Control Effect Based on Multi-Impeller Air Conditioner
16
作者 WANG Jiahao LIU Xiaomin +2 位作者 TIAN Chenye WU Liming XI Guang 《Journal of Thermal Science》 SCIE EI CAS CSCD 2022年第6期2137-2154,共18页
Air conditioner is the key air supply device to improve the indoor air heat transfer cycle and thermal environment. In this paper, according to the similarity theory, six kinds of the multi-impeller air conditioners(M... Air conditioner is the key air supply device to improve the indoor air heat transfer cycle and thermal environment. In this paper, according to the similarity theory, six kinds of the multi-impeller air conditioners(MIAC) with different numbers of axial-flow impeller are first proposed based on air conditioners with cross-flow fan(CFAC). The effects of different multi-impeller air supply modes on the indoor airflow field and temperature field are investigated by using the numerical simulation method. The validity of the computational model and method is verified by comparing the experimental measurements and numerical results. Compared with other air supply modes, the air supply distance is relatively far and the indoor environment is also improved obviously when the six-impeller air conditioner(SIAC) is used. The independent multiple impellers and outlets of SIAC make the mutual interference between the outlet airflow less, which effectively reduces the friction between the airflow and the degree of loss along the way and makes the cold and heat exchange of the whole indoor space more sufficient. The indoor thermal environment is also analyzed by using the PMV-PPD method and prototype experiment. Under the working condition of no wind, the indoor thermal comfort of human body with SIAC is better than that of CFAC. Especially in the horizontal plane of 0.6 m above the human foot, the indoor thermal environment improvement effect is the most obvious. Simultaneously, the temperature difference along the indoor height direction with the SIAC is only 1.7℃, which is 70% lower than that of the CFAC. The blowing angle between the left and right side of the SIAC is 106°, which is 31% higher than that of the CFAC. Therefore, the overall thermal comfort of the six-impeller mode is better, and the control effect of indoor environment is satisfactory. 展开更多
关键词 air conditioner multi-impeller indoor thermal environment thermal comfort numerical simulation experimental test
原文传递
Air-condition process for scalable fabrication of CdS/ZnS 1D/2D heterojunctions toward efficient and stable photocatalytic hydrogen production
17
作者 Dongdong Zhang Jie Teng +7 位作者 Hongli Yang Zhi Fang Kai Song Lin Wang Huilin Hou Xianlu Lu Chris RBowen Weiyou Yang 《Carbon Energy》 SCIE CSCD 2023年第7期1-14,共14页
We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.... We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.The as-formed heterojunctions exhibit a significantly enhanced photocatalytic H_(2) evolution rate of 14.02 mmol h^(-1) g^(-1) when irradiated with visible light,which is~10 and 85 times higher than those of pristine CdS nanosheets and CdS nanoparticles,respectively,and superior to most of the CdS-based photocatalysts reported to date.Furthermore,they provide robust photocatalytic performance with demonstratable stability over 58 h,indicating their potential for practical applications.The formation of 1D/2D heterojunctions not only provides improved exposed active sites that respond to illumination but also provides a rapid pathway to generate photogenerated carriers for efficient separation and transfer through the matrix of single-crystalline CdS nanosheets.In addition,first-principles simulations demonstrate that the existence of rich Zn vacancies increases the energy level of the ZnS valence band maximum to construct type-II and Z-scheme mixed heterojunctions,which plays a critical role in suppressing the recombination of carriers with limited photocorrosion of CdS to enhance photocatalytic behavior. 展开更多
关键词 air condition CDS HETEROJUNCTIONS photocatalytic hydrogen production ZNS
下载PDF
Fault detection and diagnosis of electric bus air conditioning systems incorporating domain knowledge and probabilistic artificial intelligence
18
作者 Fangzhou Guo Zhijie Chen Fu Xiao 《Energy and AI》 EI 2024年第2期316-330,共15页
The air conditioning systems in electric city buses usually operate in rapidly changing ambient conditions and are more likely to suffer from mechanical faults. Although many fault detection and diagnosis (FDD) method... The air conditioning systems in electric city buses usually operate in rapidly changing ambient conditions and are more likely to suffer from mechanical faults. Although many fault detection and diagnosis (FDD) methods have been developed for building air conditioning systems, they are difficult to be applied to bus air conditioners since its operation is highly dynamic and fault-free data are usually unavailable. Therefore, this paper proposes an FDD method for electric bus air conditioners to tackle the above issues. First, the method identifies faults in an unsupervised manner by comparing selected features among a group of peer systems. Then, considering the features are influenced by the operating conditions, Gaussian process regression (GPR) models are established to find the relationships between each feature and its influential parameters. The probabilistic nature of the GPR is used to differentiate predictions with large uncertainty, which are then excluded from FDD. In this way, robustness of the method is evidently improved. Finally, fault indexes are defined to detect and diagnose mechanical faults. We applied the method to a group of air conditioners in a city bus fleet. Results showed that it can effectively identify refrigerant undercharge and indoor and outdoor fan problems with low false positive/genitive rates. Also, the method is highly robust and not sensitive to the faulty systems in the bus fleet. 展开更多
关键词 Fault detection and diagnosis Predictive maintenance air conditioner Electric vehicle Data-driven model Gaussian process
原文传递
Numerical Simulation for Thermal Distribution of Air-conditioner Outdoor Units 被引量:4
19
作者 Li-Ge Tong Zhen Zhang +3 位作者 Li Wang Shao-Wu Yin Jiangfeng Yu Chun Liu 《Journal of Thermal Science》 SCIE EI CAS CSCD 2012年第3期269-275,共7页
Air-conditioners used in high-rise residential or office buildings often have outdoor units installed on the side-walls or roofs in the confined space of the buildings.The heat released from the outdoor units causes t... Air-conditioners used in high-rise residential or office buildings often have outdoor units installed on the side-walls or roofs in the confined space of the buildings.The heat released from the outdoor units causes the tem-perature rise in the confined installation space and leads to uncomfortable thermal environment and deteriorative performance of air-conditioners.The factors affecting the performance of air-conditioners are the heat released from the outdoor units,the solar radiation and the ventilation of the confined installation space,which are inves-tigated in this study and simulated by FLUENT using the porous model and discrete ordinates (DO) radiation model.It is proved that the porous model is more reliable than the solid model.The optimal installation distance from the supporting wall is obtained.The average temperature of the exit without wind is 1.18% higher than that with wind.The results show that the heat released from the outdoor units and the ventilation of the confined in-stallation space are the main factors affecting the thermal environment in the confined installation space.The in-fluence of the solar radiation is negligible. 展开更多
关键词 high-rise building air conditioner heat rejection porous model solar radiation
原文传递
基于正交试验的空调室外机顶板优化设计
20
作者 刘文钢 陈少华 +1 位作者 侯佳鑫 谢军龙 《风机技术》 2022年第6期28-32,共5页
In this paper,the modal analysis of an air conditioner outdoor unit is carried out and the simulation results are compared with the experimental results to verify its accuracy.Aseparate structural optimization analysi... In this paper,the modal analysis of an air conditioner outdoor unit is carried out and the simulation results are compared with the experimental results to verify its accuracy.Aseparate structural optimization analysis is performed for the top plate,and the compression bars of the top plate are changed from transverse to vertical placement.The simulation results show that the natural frequency and stiffness of the top plate are improved.Under the premise of vertical placement of the compression bars,a three-factor,three-level orthogonal test is conducted to find the optimal combination of low-order natural frequency and high-order natural frequency in the given range. 展开更多
关键词 air conditioner Outdoor Unit Top Plate Structure Optimization Compression Bars OrthogonalTest
下载PDF