A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment. A composite strategy has been applied for comparative analysis of the optimal venting vo...A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment. A composite strategy has been applied for comparative analysis of the optimal venting volume and the airflow distribution between the conventional hood and the novel one in this study. A Computational Fluid Dynamic (CFD) method is used to simulate the airflow fields and dust-polluted air moving paths. The CFD results show that a two-outlet hood, with one outlet located on the left of the hood, is better for improving dust-polluted air than the hood with one outlet only. It can be concluded that the number of the outlets as well as their location on the hood has a significant influence on the air flow pattern in the hood. The optimal venting volume is also a major consideration that is discussed in the study. The venting volume should be designed by considering both the effective level of air flow velocity around the dust source and the energy saving. The optimal airflow distribution may reduce the turbulence in the hood system.展开更多
Due to the increasing global demand for industrial gas, the development of large-scale cryogenic air separation systems has attracted considerable attention in recent years. Increasing the height of the adsorption bed...Due to the increasing global demand for industrial gas, the development of large-scale cryogenic air separation systems has attracted considerable attention in recent years. Increasing the height of the adsorption bed in a vertical radial flow adsorber used in cryogenic air separation systems may efficiently increase the treatment capacity of the air in the adsorber. However, uniformity of the flow distribution of the air inside the adsorber would be deteriorated using the height-increasing method. In order to reduce the non-uniformity of the flow distribution caused by the excessive height of adsorption bed in a vertical radial flow adsorber, a novel parallel connection method is proposed in the present work. The experimental apparatus is designed and constructed; the Computational Fluid Dynamics(CFD) technique is used to develop a CFD-based model, which is used to analyze the flow distribution, the static pressure drop and the radial velocity in the newly designed adsorber. In addition, the geometric parameters of annular flow channels and the adsorption bed thickness of the upper unit in the parallelconnected vertical radial flow adsorber are optimized, so that the upper and lower adsorption units could be penetrated by air simultaneously. Comparisons are made between the height-increasing method and the parallel connection method with the same adsorber height. It is shown that using the parallel connection method could reduce the difference between the maximum and minimum radial static pressure drop by 86.2% and improve the uniformity by 80% compared with those of using the height-increasing method. The optimal thickness ratio of the upper and lower adsorption units is obtained as 0.966, in which case the upper and lower adsorption units could be penetrated by air simultaneously, so that the adsorbents in adsorption space could be used more efficiently.展开更多
基金supported by the Shanghai Leading Academic Discipline Project(B604)the Henan Science and Technology Breakthrough Major Project(102102210440)+1 种基金the High School Funding Scheme for Key Young Teachersthe Education Department of Henan Province,2010
文摘A novel hood structure has been designed for the dust control system in the foundry in order to improve the working environment. A composite strategy has been applied for comparative analysis of the optimal venting volume and the airflow distribution between the conventional hood and the novel one in this study. A Computational Fluid Dynamic (CFD) method is used to simulate the airflow fields and dust-polluted air moving paths. The CFD results show that a two-outlet hood, with one outlet located on the left of the hood, is better for improving dust-polluted air than the hood with one outlet only. It can be concluded that the number of the outlets as well as their location on the hood has a significant influence on the air flow pattern in the hood. The optimal venting volume is also a major consideration that is discussed in the study. The venting volume should be designed by considering both the effective level of air flow velocity around the dust source and the energy saving. The optimal airflow distribution may reduce the turbulence in the hood system.
基金Supported by the National Key R&D Program of China(2017YFB0603702)the Natural Science Foundation of Zhejiang Province(Y15E060014)+1 种基金the National Natural Science Foundation of China(51636007)Shanghai Young Teachers Development Program(10-16-301-801)
文摘Due to the increasing global demand for industrial gas, the development of large-scale cryogenic air separation systems has attracted considerable attention in recent years. Increasing the height of the adsorption bed in a vertical radial flow adsorber used in cryogenic air separation systems may efficiently increase the treatment capacity of the air in the adsorber. However, uniformity of the flow distribution of the air inside the adsorber would be deteriorated using the height-increasing method. In order to reduce the non-uniformity of the flow distribution caused by the excessive height of adsorption bed in a vertical radial flow adsorber, a novel parallel connection method is proposed in the present work. The experimental apparatus is designed and constructed; the Computational Fluid Dynamics(CFD) technique is used to develop a CFD-based model, which is used to analyze the flow distribution, the static pressure drop and the radial velocity in the newly designed adsorber. In addition, the geometric parameters of annular flow channels and the adsorption bed thickness of the upper unit in the parallelconnected vertical radial flow adsorber are optimized, so that the upper and lower adsorption units could be penetrated by air simultaneously. Comparisons are made between the height-increasing method and the parallel connection method with the same adsorber height. It is shown that using the parallel connection method could reduce the difference between the maximum and minimum radial static pressure drop by 86.2% and improve the uniformity by 80% compared with those of using the height-increasing method. The optimal thickness ratio of the upper and lower adsorption units is obtained as 0.966, in which case the upper and lower adsorption units could be penetrated by air simultaneously, so that the adsorbents in adsorption space could be used more efficiently.