The amount of moisture in the air is represented by relative humidity(RH);an ideal level of humidity in the interior environment is between 40%and 60%at temperatures between 18°and 20°Celsius.When the RH fal...The amount of moisture in the air is represented by relative humidity(RH);an ideal level of humidity in the interior environment is between 40%and 60%at temperatures between 18°and 20°Celsius.When the RH falls below this level,the environment becomes dry,which can cause skin dryness,irritation,and discomfort at low temperatures.When the humidity level rises above 60%,a wet atmosphere develops,which encourages the growth of mold and mites.Asthma and allergy symptoms may occur as a result.Human health is harmed by excessive humidity or a lack thereof.Dehumidifiers can be used to provide an optimal level of humidity and a stable and pleasant atmosphere;certain models disinfect and purify the water,reducing the spread of bacteria.The design and implementation of a client-server indoor and outdoor air quality monitoring application are presented in this paper.The Netatmo station was used to acquire the data needed in the application.The client is an Android application that allows the user to monitor air quality over a period of their choosing.For a good monitoring process,the Netatmo modules were used to collect data from both environments(indoor:temperature(T),RH,carbon dioxide(CO_(2)),atmospheric pressure(Pa),noise and outdoor:T and RH).The data is stored in a database,using MySQL.The Android application allows the user to view the evolution of the measured parameters in the form of graphs.Also,the paper presents a prediction model of RH using Azure Machine Learning Studio(Azure ML Studio).The model is evaluated using metrics:Mean Absolute Error(MAE),Root Mean Squared Error(RMSE),Relative Absolute Error(RAE),Relative Squared Error(RSE)and Coefficient of Determination(CoD).展开更多
Individuals spend 90% of their time indoors, primarily at home or at work. Indoor environmental factors have a significant impact on human well-being. It was a longitudinal study that assessed the major factors that r...Individuals spend 90% of their time indoors, primarily at home or at work. Indoor environmental factors have a significant impact on human well-being. It was a longitudinal study that assessed the major factors that reduce indoor air quality, namely particulate matter, and bio-aerosols, using low-cost sensors and the settle plate method, respectively also to determine the effect of atmospheric parameters and land use patterns in households of commercial, industrial, residential, slum, and rural areas of the city. PM2.5 concentration levels were similar in most parts of the day across all sites. PM10.0 concentration levels increased indoors in a commercial area. PM2.5 concentration showed a negative correlation with temperature and a positive correlation with relative humidity in some areas. Very high values of PM2.5 concentration and PM10.0 concentration have been observed in this study, inside households of selected rural and urban areas. Pathogenic gram-positive cocci, gram-positive rods, Aspergillus, and Mucor species were the most common bacterial and fungal species respectively found inside households. This study examined particulate matter concentration along with bio-aerosols, as very less studies have been conducted in Jaipur the capital of Rajasthan, a state in the western part of India which assessed both of these factors together to determine the indoor air quality. Rural households surrounding the periphery of the city were found to have similar pollution levels as urban households. So, this study may form the basis for reducing pollution inside households and also for taking suitable measures for the reduction of pollution in the indoor environment.展开更多
Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using ...Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using an MQ2 gas detector,and microcontroller/Arduino-Uno.The design steps included bonding and connecting readymade sensors,coding,and finally testing the device.Testing has been conducted in Environment and Pollution Engineering Department laboratories,at the Technical Engineering College of Kirkuk.This study proposed the use of an MQ2 sensor for multi-gas rate detection which can exist indoors.The system uses also a DHT22 sensor for measuring environment temperature and humidity.The sensors are connected to Arduino and LCD to present data on LCD by powering the system with external power.Overall,the testing was conducted,and the device served as a measuring tool for indoor air as an accurate multi-gas rate detector.展开更多
This research focuses on the evaluation of diverse approaches for removing formaldehyde from indoor environments,which is a significant concern for indoor air quality.The study systematically examines physical,chemica...This research focuses on the evaluation of diverse approaches for removing formaldehyde from indoor environments,which is a significant concern for indoor air quality.The study systematically examines physical,chemical,and biological methods to ascertain their effectiveness in formaldehyde mitigation.Physical methods,including air circulation and adsorption,particularly with activated carbon and molecular sieves,are assessed for their efficiency in various concentration scenarios.Chemical methods,such as photocatalytic oxidation using titanium dioxide and plasma technology,are analyzed for their ability to decompose formaldehyde into non-toxic substances.Additionally,biological methods involving plant purification and microbial transformation are explored for their eco-friendly and sustainable removal capabilities.The paper concludes that while each method has its merits,a combined approach may offer the most effective solution for reducing indoor formaldehyde levels.The study underscores the need for further research to integrate these methods in a practical,cost-effective,and environmentally sustainable manner,highlighting their potential to improve indoor air quality significantly.展开更多
Complaints on the indoor environment of the residents in recent decades have become a common problem in the Swedish housing. The buildings themselves are said to be the cause of problems, and it is given a vague pictu...Complaints on the indoor environment of the residents in recent decades have become a common problem in the Swedish housing. The buildings themselves are said to be the cause of problems, and it is given a vague picture of both the exposure and the effect of the problems. The symptoms that residents and users state are often common in the population such as headache, fatigue, mucosal disorders and skin problems. It must be considered that the air that people routinely inhale contains impurities of various kinds, both in- and outdoors. An important source of contamination indoors is the microorganisms that are pathogenic, so called agents. Examples of infectious agents are viruses, fungi, bacteria and protozoa. The purpose of this project is to examine whether a physical measurement is possible to obtain for identifying a possible threshold level of air pollution in the indoor environment. In this study, carried out through physical measurements, the results show major deficiencies in the Swedish school environment. If we study the emissions in the important health-related size range of particles larger than 5.0 microns, before and after measures, the environmental benefits are clarified since over 90% of contaminants larger than 5.0 microns have been eliminated.展开更多
A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive o...A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 ±1.53 mg/m^3) compared to outdoor air (0.71± 0.46 mg/m^3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.展开更多
This is the first detailed characterization of the airborne bacterial profiles in indoor environments. Two restaurants were selected for this study. Fifteen genera of bacteria were isolated from each restaurant and id...This is the first detailed characterization of the airborne bacterial profiles in indoor environments. Two restaurants were selected for this study. Fifteen genera of bacteria were isolated from each restaurant and identified by three different bacterial identification systems including MIDI, Biolog and Riboprinter. The dominant bacteria of both restaurants were Gram-positive bacteria in which Micrococcus and Bacillus species were the most abundant. Most bacteria identified were representative species of skin and respiratory tract of human, and soil. Although the bacterial levels in these two restaurants were below the limit of the Hong Kong Indoor Air Quality Objective (HKIAQO) Level 1 standard (i.e., 〈 500 cfu/m^3), the majority of these bacteria were opportunistic pathogens. These results suggested that the identity of airborne bacteria should also be included in the IAQ to ensure there is a safety guideline for the public.展开更多
Objective The changes in serum adipokines and cytokines related to oxidative stress were examined during 3 months ‘Off to On’ and ‘On to Off’ periods using negatively charged particle-dominant indoor air condition...Objective The changes in serum adipokines and cytokines related to oxidative stress were examined during 3 months ‘Off to On’ and ‘On to Off’ periods using negatively charged particle-dominant indoor air conditions(NCPDIAC).Methods Seven volunteers participated in the study,which included ‘OFF to 3 months ON’ periods(ON trials) for a total of 16 times,and ‘ON to 3 months OFF’(OFF trials) periods for a total of 13 times.Results With the exception of one case,serum amyloid A(SAA) levels decreased significantly during the ON trials.Conclusion Considering that SAA is an acute phase reactive protein such as C reactive protein(CRP),this observed decrease might indicate the prevention of cardiovascular and atherosclerotic changes,since an increase in high-sensitive CRP is associated with the subsequent detection of these events.展开更多
Objective:To investigate the quality of indoor air of different wards and units of Olabisi Onabanjo University Teaching Hospital, Sagamu, to ascertain their contribution to infection rate in the hospital.Methods:The m...Objective:To investigate the quality of indoor air of different wards and units of Olabisi Onabanjo University Teaching Hospital, Sagamu, to ascertain their contribution to infection rate in the hospital.Methods:The microbial quality of indoor air of nine wards/units of Olabisi Onabanjo University Teaching Hospital, Sagamu, Nigeria was conducted. Sedimentation technique using open Petri-dishes containing different culture media was employed and samplings were done twice daily, one in the morning shortly after cleaning and before influx of people/patients into the wards/units and the other in the evening when a lot of activities would have taken place in these wards. Isolates were identified according to standard methods.Results:Results showed that there was a statistically significant difference(氈2= 6.0167) in the bacteria population of the different sampling time whereas it was not so for fungi population(氈2= 0.2857). Male medical ward(MMW) and male surgical general(MSG) recorded the highest bacterial and fungal growth while the operating theatre(OT) was almost free of microbial burden. The bacteria isolates were Staphylococcus aureus, Klebsiellasp., Bacillus cereus, Bacillus subtilis, Streptococcus pyogenes andSerratia marscenceswhile the fungi isolates includedAspergillus flavus, Penicilliumsp.,Fusariumsp.,Candida albicansandAlternariasp.Staphylococcus aureuswas the predominantly isolated bacterium whilePenicilliumsp. was the most isolated fungus.Conclusions:Though most of the microbial isolates were potential and or opportunistic pathogens, there was no correlation between the isolates in this study and the surveillance report of nosocomial infection during the period of study, hence the contribution of the indoor air cannot be established. From the reduction noticed in the morning samples, stringent measures such as proper disinfection and regular cleaning, restriction of patient relatives' movement in and out of the wards/units need to be enforced so as to improve the quality of indoor air of our hospital wards/units.展开更多
From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO2)and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the eval...From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO2)and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the evaluation method of logarithmic index was adopted as the evaluation means of IAQ.Then the recommended limits(RL)of typical contaminants CO2 and HCHO were given through analysis and calculation.The limits of CO2 and HCHO in Indoor Air Quality Standard of China or other existing standards probably correspond to the level of PD=25(%).The result shows that the existing standards fail to meet the requirement of the definition of "acceptable indoor air quality",that is to say,less than 20% of the people express dissatisfaction.When PD=20%,RL of CO2 and HCHO are 728×10-6 and 0.068×10-6 respectively,which are stricter than the limits in the existing standards.The method proposed in this paper is applicable to 13.1%≤PD≤86.7%.展开更多
The Spanish NGO “Alianza por la Solidaridad” has installed improved cookstoves in 3000 households during 2012 and 2013 to improve energy efficiency reducing fuelwood consumption and to improve indoor air quality. Th...The Spanish NGO “Alianza por la Solidaridad” has installed improved cookstoves in 3000 households during 2012 and 2013 to improve energy efficiency reducing fuelwood consumption and to improve indoor air quality. The type of cookstoves were Noflaye Jeeg and Noflaye Jaboot and were installed in the Cassamance Natural Subregion covering part of Senegal, The Gambia and Guinea-Bissau. The Technical University of Madrid (UPM) has conducted a field study on a sample of these households to assess the effect of improved cookstoves on kitchen air quality. Measurements of carbon monoxide (CO) and fine particle matter (PM2.5) were taken for 24-hr period before and after the installation of improved cookstoves. The 24-hr mean CO concentrations were lower than the World Health Organization (WHO) guidelines for Guinea-Bissau but higher for Senegal and Gambia, even after the installation of improved cookstoves. As for PM2.5 concentrations, 24-hr mean were always higher than these guidelines. However, improved cookstoves produced significant reductions on 24-hr mean CO and PM2.5 concentrations in Senegal and for mean and maximum PM2.5 concentration on Gambia. Although this variability needs to be explained by further research to determine which other factors could affect indoor air pollution, the study provided a better understanding of the problem and envisaged alternatives to be implemented in future phases of the NGO project.展开更多
In this study,a CO_(2) capture material in the form of liquid-like adsorbents(LLAs) is developed to overcome the limitations of conventional types of adsorbents.The increase in indoor activities necessitates the captu...In this study,a CO_(2) capture material in the form of liquid-like adsorbents(LLAs) is developed to overcome the limitations of conventional types of adsorbents.The increase in indoor activities necessitates the capture of CO_(2) in enclosed indoor spaces.Indoor spaces require safe and stable materials for CO_(2) capture because humans are present in these spaces.Solid adsorbents are mainly used because liquid absorbents are unsuitable owing to noise and scattering problems.In LLA,the liquid absorbent assembled by carbon nanotubes(CNTs) is solidified and prevented from flowing and scattering indoor.LLAs present to maintain 95% of initial capacity after recycling 20 times,and have characteristics that can be regenerated in a low temperature heat source(80 to 120℃) and moisture resistance.This work not only provides indoor useable CO_(2) capture materials,but also offers a new prospect in the field of adsorbents.展开更多
To analyze the thermal comfort and indoor air quality (IAQ) in a medium-sized mechanically ventilated gymnasium in Beijing,a field study was carried out. PHOENICS,one of the CFD software,was chosen to simulate the dis...To analyze the thermal comfort and indoor air quality (IAQ) in a medium-sized mechanically ventilated gymnasium in Beijing,a field study was carried out. PHOENICS,one of the CFD software,was chosen to simulate the distribution of the indicators of indoor air in the gymnasium to check the air-conditioning parameters reasonable or not. And there was a questionnaire for audiences and staff about the acceptance and satisfaction of the thermal comfort,simultaneously,some environmental parameters were monitored. Then an experiment was carried out in gymnasium with the plate sedimentation to the biological aerosol in the air. Finally,the thermal comfort and IAQ in the gymnasium were assessed based on the results of above questionnaire survey and measurements. The results show that most parameters of the environmental are within the standard limits of thermal comfort and IAQ in the monitored period,and the biological contaminants initially come from human beings. The main species in the gymnasium are streptobacillus,coccus,cladosporium,penicillium and neurospora.展开更多
Objective The study was designed to compare the combustion products of coal gas, liquefied petroleum gas and natural gas in relation to indoor air pollution. Methods Regular pollutants including B(a)P were monitored a...Objective The study was designed to compare the combustion products of coal gas, liquefied petroleum gas and natural gas in relation to indoor air pollution. Methods Regular pollutants including B(a)P were monitored and 1-hydroxy pyrene were tested in urine of the enrolled subjects. Radon concentrations and their changes in four seasons were also monitored in the city natural gas from its source plant and transfer stations to final users. To analyze organic components of coal gas, liquefied petroleum gas and natural gas, a high-flow sampling device specially designed was used to collect their combustion products, and semi-volatile organic compounds contained in the particles were detected by gas chromatograph-mass spectrograph (GC/MS). Results Findings in the study showed that the regular indoor air pollutants particles and CO were all above the standard in winter when heating facilities were operated in the city, but they were lowest in kitchens using natural gas; furthermore, although NO2 and CO2 were slightly higher in natural gas, B(a)P concentration was lower in this group and 1-hydroxy pyrene was lowest in urine of the subjects exposed to natural gas. Organic compounds were more complicated in coal gas and liquefied petroleum gas than in natural gas. The concentration of radon in natural gas accounted for less than 1‰ of its effective dose contributing to indoor air pollution in Beijing households. Conclusion Compared to traditional fuels, gases are deemed as clean ones, and natural gas is shown to be cleaner than the other two gases.展开更多
To establish the model of indoor air pollution forecast for decoration. Methods The model was based on the balance model for diffusing mass. Results The data between testing concentration and estimating concentration ...To establish the model of indoor air pollution forecast for decoration. Methods The model was based on the balance model for diffusing mass. Results The data between testing concentration and estimating concentration were compared. The maximal error was less than 30% and average error was 14.6%. Conclusion The model can easily predict whether the pollution for decoration exceeds the standard and how long the room is decorated.展开更多
Increasing incidents of indoor air quality(IAQ) related complaints lead us to the fact that IAQ has become a significant occupational health and environmental issue. However, how to effectively evaluate IAQ under diff...Increasing incidents of indoor air quality(IAQ) related complaints lead us to the fact that IAQ has become a significant occupational health and environmental issue. However, how to effectively evaluate IAQ under different scale of multiple indicators is still a challenge. The traditional single-indicator method is subjected to uncertainties in assessing IAQ due to different subjectivity on good or bad quality and scalar differences of data set. In this study, a multilevel integrated weighted average IAQ method including initial walking through assessment(IWA) and two-layers weighted average method are developed and applied to evaluate IAQ of the laboratory building at the University of Regina in Canada. Some important chemical parameters related to IAQ in terms of volatile organic compounds(VOCs), methanol(HCHO), carbon dioxide(CO2), and carbon monoxide(CO) are evaluated based on 5 months continuous monitoring data. The new integrated assessment result can not only indicates the risk of an individual parameter, but also able to quantify the overall IAQ risk on the sampling site. Finally, some recommendations based on the result are proposed to address sustainable IAQ practices in the sampling area.展开更多
Indoor air pollution(IAP) is a key contributor to the global burden of disease mainly in developing countries. The use of solid fuel for cooking and heating is the main source of IAP in developing countries, accountin...Indoor air pollution(IAP) is a key contributor to the global burden of disease mainly in developing countries. The use of solid fuel for cooking and heating is the main source of IAP in developing countries, accounting for an estimated 3.5 million deaths and 4.5% of Disability-Adjusted Life Years in 2010. Other sources of IAP include indoor smoking, infiltration of pollutants from outdoor sources and substances emitted from an array of human utilities and biological materials. Children are among the most vulnerable groups for adverse effects of IAP. The respiratory system is a primary target of air pollutants resulting in a wide range of acute and chronic effects. The spectrum of respiratory adverse effects ranges from mild subclinical changes and mild symptoms to life threatening conditions and even death. However, IAP is a modifiable risk factor having potential mitigating interventions. Possible interventions range from simple be-havior change to structural changes and from shifting of unclean cooking fuel to clean cooking fuel. Shifting from use of solid fuel to clean fuel invariably reduces the household air pollution in developing countries, but such a change is challenging. This review aims to summarize the available information on IAP exposure during childhood and its effects on respiratory health in developing countries. It specifically discusses the common sources of IAP, susceptibility of children to air pollution, mechanisms of action, common respiratory conditions, preventive and mitigating strategies.展开更多
Three representative types of houses in Beijing were selected and, in each type, smoking and nonsmoking households were compared. IP, RP. and CO concentrations in the living room and kitchen were monitored during each...Three representative types of houses in Beijing were selected and, in each type, smoking and nonsmoking households were compared. IP, RP. and CO concentrations in the living room and kitchen were monitored during each season. and the level of COHb in the heads of the households were measured. The study showed that indoor air pollution was rather severe, especially during winter. when paniculate concentrations markedly exceeded the standard and CO concentration was as high as 47 ppm. Indoor air pollution was closely related to the type of house, particularly to the mode of heating. In houses. of the same type, pollution improved greatly after central heating facilities were installed. Analysis of 30 elements revealed that pollution was typically caused by coal burning. aggravated by dusty wind, but high indoor Pb levels were probably due to the use of LPG for cooking. In our study the effect of cigarette smoking was sometimes masked by the severe indoor pollution. (C)1990 Academic Press, Inc.展开更多
Air quality was measured inside 628 United Arab Emirates (UAE) personal residences. Weekly average concentrations of carbon monoxide (CO), formaldehyde (HCHO), hydrogen sulfide (H2S), nitrogen dioxide (NO2), sulfur di...Air quality was measured inside 628 United Arab Emirates (UAE) personal residences. Weekly average concentrations of carbon monoxide (CO), formaldehyde (HCHO), hydrogen sulfide (H2S), nitrogen dioxide (NO2), sulfur dioxide (SO2), and three size fractions of particulate matter (PM2.5, PMc, and PM10) were determined in each home. In a subset of the homes, measurements of outdoor air quality, ultrafine PM concentrations, and elemental PM concentrations were also made. Questionnaires were administered to obtain information on housing demographics and lifestyle habits. Air measurements were performed using simple and cost effective passive samplers. The 90th percentiles of indoor CO, HCHO, H2S, NO2, and SO2 were 1.55 ppm, 0.05 ppm, 0.12 ppm, 0.01 ppm, and 0.05 ppm, respectively. Median indoor PM2.5, PMc, and PM10, concentrations were 5.73 μg/m3, 29.4 μg/m3, and 35.2 μg/m3, respectively. The median indoor concentration of ultrafine PM was 3.62 × 1010 particles/m3. Indoor/outdoor ratios for PM were 0.44, 0.41, and 0.38 for ultrafine PM, PM2.5, and PM10, respectively. These values fall within the range of other indoor air studies findings conducted in developing countries. Air conditioning, smoking, and attached kitchens were significantly correlated with indoor levels of carbon monoxide. In addition, indoor concentrations of PM2.5 and PM10 were significantly correlated with vehicles parked within five meters of the home, central air conditioning, and having attached kitchens. This is the first robust indoor air quality data set developed for the UAE. This study demonstrates that screening level tools are a good initial step for assessing air quality when logistical issues (distance, language, cultural, training) and intrusion into personal lives need to be minimized.展开更多
The paper presents a simple model for outdoor air contaminant transmission into occupied rooms. In the model, several factors such as filtration, ventilation, deposition, re-emission, outdoor concentration and indoor ...The paper presents a simple model for outdoor air contaminant transmission into occupied rooms. In the model, several factors such as filtration, ventilation, deposition, re-emission, outdoor concentration and indoor sources are included. The model results show that the air exchange rate plays an important role in the transmission of outdoor contaminants into the indoor environment. The model shows that increasing the value of the filtration efficiency decreases the mass concentration of indoor particles. In addition, if outdoor aerosol particles have a periodic behaviour, indoor aerosol particles also behave periodically but smoother. Indoor sources are found to be able to increase indoor concentrations greatly and continuously.展开更多
基金supported by the Project“Entrepreneurial competences and excellence research in doctoral and postdoctoral programs-ANTREDOC”,project cofounded by the European Social Fund financing agreement No.56437/24.07.2019.
文摘The amount of moisture in the air is represented by relative humidity(RH);an ideal level of humidity in the interior environment is between 40%and 60%at temperatures between 18°and 20°Celsius.When the RH falls below this level,the environment becomes dry,which can cause skin dryness,irritation,and discomfort at low temperatures.When the humidity level rises above 60%,a wet atmosphere develops,which encourages the growth of mold and mites.Asthma and allergy symptoms may occur as a result.Human health is harmed by excessive humidity or a lack thereof.Dehumidifiers can be used to provide an optimal level of humidity and a stable and pleasant atmosphere;certain models disinfect and purify the water,reducing the spread of bacteria.The design and implementation of a client-server indoor and outdoor air quality monitoring application are presented in this paper.The Netatmo station was used to acquire the data needed in the application.The client is an Android application that allows the user to monitor air quality over a period of their choosing.For a good monitoring process,the Netatmo modules were used to collect data from both environments(indoor:temperature(T),RH,carbon dioxide(CO_(2)),atmospheric pressure(Pa),noise and outdoor:T and RH).The data is stored in a database,using MySQL.The Android application allows the user to view the evolution of the measured parameters in the form of graphs.Also,the paper presents a prediction model of RH using Azure Machine Learning Studio(Azure ML Studio).The model is evaluated using metrics:Mean Absolute Error(MAE),Root Mean Squared Error(RMSE),Relative Absolute Error(RAE),Relative Squared Error(RSE)and Coefficient of Determination(CoD).
文摘Individuals spend 90% of their time indoors, primarily at home or at work. Indoor environmental factors have a significant impact on human well-being. It was a longitudinal study that assessed the major factors that reduce indoor air quality, namely particulate matter, and bio-aerosols, using low-cost sensors and the settle plate method, respectively also to determine the effect of atmospheric parameters and land use patterns in households of commercial, industrial, residential, slum, and rural areas of the city. PM2.5 concentration levels were similar in most parts of the day across all sites. PM10.0 concentration levels increased indoors in a commercial area. PM2.5 concentration showed a negative correlation with temperature and a positive correlation with relative humidity in some areas. Very high values of PM2.5 concentration and PM10.0 concentration have been observed in this study, inside households of selected rural and urban areas. Pathogenic gram-positive cocci, gram-positive rods, Aspergillus, and Mucor species were the most common bacterial and fungal species respectively found inside households. This study examined particulate matter concentration along with bio-aerosols, as very less studies have been conducted in Jaipur the capital of Rajasthan, a state in the western part of India which assessed both of these factors together to determine the indoor air quality. Rural households surrounding the periphery of the city were found to have similar pollution levels as urban households. So, this study may form the basis for reducing pollution inside households and also for taking suitable measures for the reduction of pollution in the indoor environment.
文摘Besides the need for low-cost instruments for air pollution measurement and detection,nowadays there are many concerns about air pollution due to the fast changes and used technologies.This research was applied using an MQ2 gas detector,and microcontroller/Arduino-Uno.The design steps included bonding and connecting readymade sensors,coding,and finally testing the device.Testing has been conducted in Environment and Pollution Engineering Department laboratories,at the Technical Engineering College of Kirkuk.This study proposed the use of an MQ2 sensor for multi-gas rate detection which can exist indoors.The system uses also a DHT22 sensor for measuring environment temperature and humidity.The sensors are connected to Arduino and LCD to present data on LCD by powering the system with external power.Overall,the testing was conducted,and the device served as a measuring tool for indoor air as an accurate multi-gas rate detector.
文摘This research focuses on the evaluation of diverse approaches for removing formaldehyde from indoor environments,which is a significant concern for indoor air quality.The study systematically examines physical,chemical,and biological methods to ascertain their effectiveness in formaldehyde mitigation.Physical methods,including air circulation and adsorption,particularly with activated carbon and molecular sieves,are assessed for their efficiency in various concentration scenarios.Chemical methods,such as photocatalytic oxidation using titanium dioxide and plasma technology,are analyzed for their ability to decompose formaldehyde into non-toxic substances.Additionally,biological methods involving plant purification and microbial transformation are explored for their eco-friendly and sustainable removal capabilities.The paper concludes that while each method has its merits,a combined approach may offer the most effective solution for reducing indoor formaldehyde levels.The study underscores the need for further research to integrate these methods in a practical,cost-effective,and environmentally sustainable manner,highlighting their potential to improve indoor air quality significantly.
文摘Complaints on the indoor environment of the residents in recent decades have become a common problem in the Swedish housing. The buildings themselves are said to be the cause of problems, and it is given a vague picture of both the exposure and the effect of the problems. The symptoms that residents and users state are often common in the population such as headache, fatigue, mucosal disorders and skin problems. It must be considered that the air that people routinely inhale contains impurities of various kinds, both in- and outdoors. An important source of contamination indoors is the microorganisms that are pathogenic, so called agents. Examples of infectious agents are viruses, fungi, bacteria and protozoa. The purpose of this project is to examine whether a physical measurement is possible to obtain for identifying a possible threshold level of air pollution in the indoor environment. In this study, carried out through physical measurements, the results show major deficiencies in the Swedish school environment. If we study the emissions in the important health-related size range of particles larger than 5.0 microns, before and after measures, the environmental benefits are clarified since over 90% of contaminants larger than 5.0 microns have been eliminated.
文摘A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (ATD) coupled with gas chromatography-mass spectrometry (GC/MS). This methodology can be applied in cases of sick building syndrome (SBS) evaluation, in which building occupants experience a series of varied symptoms that appear to be linked to time spent in the building. Chemical pollutants concentrations (e.g., VOC) have been described to contribute to SBS. To exemplify the methodology, a qualitative determination and an evaluation of existing VOC were performed in a dwelling where the occupants experienced the SBS symptoms. Higher total VOC (TVOC) levels were detected during episodes in indoor air (1.33 ±1.53 mg/m^3) compared to outdoor air (0.71± 0.46 mg/m^3). The concentrations of individual VOCs, such as ethanol, acetone, isopropanol, 1-butanol, acetic acid, acetonitrile and 1-methoxy-2-propanol, were also higher than the expected for a standard dwelling. The external source of VOC was found to be an undeclared activity of storage and manipulation of solvents located at the bottom of a contiguous building.
基金supported by a research grant from the Research Grant Council of the Hong Kong SAR Government, China
文摘This is the first detailed characterization of the airborne bacterial profiles in indoor environments. Two restaurants were selected for this study. Fifteen genera of bacteria were isolated from each restaurant and identified by three different bacterial identification systems including MIDI, Biolog and Riboprinter. The dominant bacteria of both restaurants were Gram-positive bacteria in which Micrococcus and Bacillus species were the most abundant. Most bacteria identified were representative species of skin and respiratory tract of human, and soil. Although the bacterial levels in these two restaurants were below the limit of the Hong Kong Indoor Air Quality Objective (HKIAQO) Level 1 standard (i.e., 〈 500 cfu/m^3), the majority of these bacteria were opportunistic pathogens. These results suggested that the identity of airborne bacteria should also be included in the IAQ to ensure there is a safety guideline for the public.
基金supported by a Kawasaki Medical School Research Grant(28B051)
文摘Objective The changes in serum adipokines and cytokines related to oxidative stress were examined during 3 months ‘Off to On’ and ‘On to Off’ periods using negatively charged particle-dominant indoor air conditions(NCPDIAC).Methods Seven volunteers participated in the study,which included ‘OFF to 3 months ON’ periods(ON trials) for a total of 16 times,and ‘ON to 3 months OFF’(OFF trials) periods for a total of 13 times.Results With the exception of one case,serum amyloid A(SAA) levels decreased significantly during the ON trials.Conclusion Considering that SAA is an acute phase reactive protein such as C reactive protein(CRP),this observed decrease might indicate the prevention of cardiovascular and atherosclerotic changes,since an increase in high-sensitive CRP is associated with the subsequent detection of these events.
文摘Objective:To investigate the quality of indoor air of different wards and units of Olabisi Onabanjo University Teaching Hospital, Sagamu, to ascertain their contribution to infection rate in the hospital.Methods:The microbial quality of indoor air of nine wards/units of Olabisi Onabanjo University Teaching Hospital, Sagamu, Nigeria was conducted. Sedimentation technique using open Petri-dishes containing different culture media was employed and samplings were done twice daily, one in the morning shortly after cleaning and before influx of people/patients into the wards/units and the other in the evening when a lot of activities would have taken place in these wards. Isolates were identified according to standard methods.Results:Results showed that there was a statistically significant difference(氈2= 6.0167) in the bacteria population of the different sampling time whereas it was not so for fungi population(氈2= 0.2857). Male medical ward(MMW) and male surgical general(MSG) recorded the highest bacterial and fungal growth while the operating theatre(OT) was almost free of microbial burden. The bacteria isolates were Staphylococcus aureus, Klebsiellasp., Bacillus cereus, Bacillus subtilis, Streptococcus pyogenes andSerratia marscenceswhile the fungi isolates includedAspergillus flavus, Penicilliumsp.,Fusariumsp.,Candida albicansandAlternariasp.Staphylococcus aureuswas the predominantly isolated bacterium whilePenicilliumsp. was the most isolated fungus.Conclusions:Though most of the microbial isolates were potential and or opportunistic pathogens, there was no correlation between the isolates in this study and the surveillance report of nosocomial infection during the period of study, hence the contribution of the indoor air cannot be established. From the reduction noticed in the morning samples, stringent measures such as proper disinfection and regular cleaning, restriction of patient relatives' movement in and out of the wards/units need to be enforced so as to improve the quality of indoor air of our hospital wards/units.
文摘From the view of both objective and subjective factors,the indoor air quality(IAQ)evaluation was considered.Carbon dioxide(CO2)and formaldehyde(HCHO)were selected as the typical contaminants of indoor air,and the evaluation method of logarithmic index was adopted as the evaluation means of IAQ.Then the recommended limits(RL)of typical contaminants CO2 and HCHO were given through analysis and calculation.The limits of CO2 and HCHO in Indoor Air Quality Standard of China or other existing standards probably correspond to the level of PD=25(%).The result shows that the existing standards fail to meet the requirement of the definition of "acceptable indoor air quality",that is to say,less than 20% of the people express dissatisfaction.When PD=20%,RL of CO2 and HCHO are 728×10-6 and 0.068×10-6 respectively,which are stricter than the limits in the existing standards.The method proposed in this paper is applicable to 13.1%≤PD≤86.7%.
文摘The Spanish NGO “Alianza por la Solidaridad” has installed improved cookstoves in 3000 households during 2012 and 2013 to improve energy efficiency reducing fuelwood consumption and to improve indoor air quality. The type of cookstoves were Noflaye Jeeg and Noflaye Jaboot and were installed in the Cassamance Natural Subregion covering part of Senegal, The Gambia and Guinea-Bissau. The Technical University of Madrid (UPM) has conducted a field study on a sample of these households to assess the effect of improved cookstoves on kitchen air quality. Measurements of carbon monoxide (CO) and fine particle matter (PM2.5) were taken for 24-hr period before and after the installation of improved cookstoves. The 24-hr mean CO concentrations were lower than the World Health Organization (WHO) guidelines for Guinea-Bissau but higher for Senegal and Gambia, even after the installation of improved cookstoves. As for PM2.5 concentrations, 24-hr mean were always higher than these guidelines. However, improved cookstoves produced significant reductions on 24-hr mean CO and PM2.5 concentrations in Senegal and for mean and maximum PM2.5 concentration on Gambia. Although this variability needs to be explained by further research to determine which other factors could affect indoor air pollution, the study provided a better understanding of the problem and envisaged alternatives to be implemented in future phases of the NGO project.
基金supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT)(Grant number:2020R1A5A1018153 and No.2020R1A6A3A01095950)。
文摘In this study,a CO_(2) capture material in the form of liquid-like adsorbents(LLAs) is developed to overcome the limitations of conventional types of adsorbents.The increase in indoor activities necessitates the capture of CO_(2) in enclosed indoor spaces.Indoor spaces require safe and stable materials for CO_(2) capture because humans are present in these spaces.Solid adsorbents are mainly used because liquid absorbents are unsuitable owing to noise and scattering problems.In LLA,the liquid absorbent assembled by carbon nanotubes(CNTs) is solidified and prevented from flowing and scattering indoor.LLAs present to maintain 95% of initial capacity after recycling 20 times,and have characteristics that can be regenerated in a low temperature heat source(80 to 120℃) and moisture resistance.This work not only provides indoor useable CO_(2) capture materials,but also offers a new prospect in the field of adsorbents.
基金Project(2006BAJ02A10) supported by the National Key Technologies R & D Program of China
文摘To analyze the thermal comfort and indoor air quality (IAQ) in a medium-sized mechanically ventilated gymnasium in Beijing,a field study was carried out. PHOENICS,one of the CFD software,was chosen to simulate the distribution of the indicators of indoor air in the gymnasium to check the air-conditioning parameters reasonable or not. And there was a questionnaire for audiences and staff about the acceptance and satisfaction of the thermal comfort,simultaneously,some environmental parameters were monitored. Then an experiment was carried out in gymnasium with the plate sedimentation to the biological aerosol in the air. Finally,the thermal comfort and IAQ in the gymnasium were assessed based on the results of above questionnaire survey and measurements. The results show that most parameters of the environmental are within the standard limits of thermal comfort and IAQ in the monitored period,and the biological contaminants initially come from human beings. The main species in the gymnasium are streptobacillus,coccus,cladosporium,penicillium and neurospora.
文摘Objective The study was designed to compare the combustion products of coal gas, liquefied petroleum gas and natural gas in relation to indoor air pollution. Methods Regular pollutants including B(a)P were monitored and 1-hydroxy pyrene were tested in urine of the enrolled subjects. Radon concentrations and their changes in four seasons were also monitored in the city natural gas from its source plant and transfer stations to final users. To analyze organic components of coal gas, liquefied petroleum gas and natural gas, a high-flow sampling device specially designed was used to collect their combustion products, and semi-volatile organic compounds contained in the particles were detected by gas chromatograph-mass spectrograph (GC/MS). Results Findings in the study showed that the regular indoor air pollutants particles and CO were all above the standard in winter when heating facilities were operated in the city, but they were lowest in kitchens using natural gas; furthermore, although NO2 and CO2 were slightly higher in natural gas, B(a)P concentration was lower in this group and 1-hydroxy pyrene was lowest in urine of the subjects exposed to natural gas. Organic compounds were more complicated in coal gas and liquefied petroleum gas than in natural gas. The concentration of radon in natural gas accounted for less than 1‰ of its effective dose contributing to indoor air pollution in Beijing households. Conclusion Compared to traditional fuels, gases are deemed as clean ones, and natural gas is shown to be cleaner than the other two gases.
基金This study was support by Tenth-five Program of China (2001BA70B02)
文摘To establish the model of indoor air pollution forecast for decoration. Methods The model was based on the balance model for diffusing mass. Results The data between testing concentration and estimating concentration were compared. The maximal error was less than 30% and average error was 14.6%. Conclusion The model can easily predict whether the pollution for decoration exceeds the standard and how long the room is decorated.
文摘Increasing incidents of indoor air quality(IAQ) related complaints lead us to the fact that IAQ has become a significant occupational health and environmental issue. However, how to effectively evaluate IAQ under different scale of multiple indicators is still a challenge. The traditional single-indicator method is subjected to uncertainties in assessing IAQ due to different subjectivity on good or bad quality and scalar differences of data set. In this study, a multilevel integrated weighted average IAQ method including initial walking through assessment(IWA) and two-layers weighted average method are developed and applied to evaluate IAQ of the laboratory building at the University of Regina in Canada. Some important chemical parameters related to IAQ in terms of volatile organic compounds(VOCs), methanol(HCHO), carbon dioxide(CO2), and carbon monoxide(CO) are evaluated based on 5 months continuous monitoring data. The new integrated assessment result can not only indicates the risk of an individual parameter, but also able to quantify the overall IAQ risk on the sampling site. Finally, some recommendations based on the result are proposed to address sustainable IAQ practices in the sampling area.
文摘Indoor air pollution(IAP) is a key contributor to the global burden of disease mainly in developing countries. The use of solid fuel for cooking and heating is the main source of IAP in developing countries, accounting for an estimated 3.5 million deaths and 4.5% of Disability-Adjusted Life Years in 2010. Other sources of IAP include indoor smoking, infiltration of pollutants from outdoor sources and substances emitted from an array of human utilities and biological materials. Children are among the most vulnerable groups for adverse effects of IAP. The respiratory system is a primary target of air pollutants resulting in a wide range of acute and chronic effects. The spectrum of respiratory adverse effects ranges from mild subclinical changes and mild symptoms to life threatening conditions and even death. However, IAP is a modifiable risk factor having potential mitigating interventions. Possible interventions range from simple be-havior change to structural changes and from shifting of unclean cooking fuel to clean cooking fuel. Shifting from use of solid fuel to clean fuel invariably reduces the household air pollution in developing countries, but such a change is challenging. This review aims to summarize the available information on IAP exposure during childhood and its effects on respiratory health in developing countries. It specifically discusses the common sources of IAP, susceptibility of children to air pollution, mechanisms of action, common respiratory conditions, preventive and mitigating strategies.
文摘Three representative types of houses in Beijing were selected and, in each type, smoking and nonsmoking households were compared. IP, RP. and CO concentrations in the living room and kitchen were monitored during each season. and the level of COHb in the heads of the households were measured. The study showed that indoor air pollution was rather severe, especially during winter. when paniculate concentrations markedly exceeded the standard and CO concentration was as high as 47 ppm. Indoor air pollution was closely related to the type of house, particularly to the mode of heating. In houses. of the same type, pollution improved greatly after central heating facilities were installed. Analysis of 30 elements revealed that pollution was typically caused by coal burning. aggravated by dusty wind, but high indoor Pb levels were probably due to the use of LPG for cooking. In our study the effect of cigarette smoking was sometimes masked by the severe indoor pollution. (C)1990 Academic Press, Inc.
文摘Air quality was measured inside 628 United Arab Emirates (UAE) personal residences. Weekly average concentrations of carbon monoxide (CO), formaldehyde (HCHO), hydrogen sulfide (H2S), nitrogen dioxide (NO2), sulfur dioxide (SO2), and three size fractions of particulate matter (PM2.5, PMc, and PM10) were determined in each home. In a subset of the homes, measurements of outdoor air quality, ultrafine PM concentrations, and elemental PM concentrations were also made. Questionnaires were administered to obtain information on housing demographics and lifestyle habits. Air measurements were performed using simple and cost effective passive samplers. The 90th percentiles of indoor CO, HCHO, H2S, NO2, and SO2 were 1.55 ppm, 0.05 ppm, 0.12 ppm, 0.01 ppm, and 0.05 ppm, respectively. Median indoor PM2.5, PMc, and PM10, concentrations were 5.73 μg/m3, 29.4 μg/m3, and 35.2 μg/m3, respectively. The median indoor concentration of ultrafine PM was 3.62 × 1010 particles/m3. Indoor/outdoor ratios for PM were 0.44, 0.41, and 0.38 for ultrafine PM, PM2.5, and PM10, respectively. These values fall within the range of other indoor air studies findings conducted in developing countries. Air conditioning, smoking, and attached kitchens were significantly correlated with indoor levels of carbon monoxide. In addition, indoor concentrations of PM2.5 and PM10 were significantly correlated with vehicles parked within five meters of the home, central air conditioning, and having attached kitchens. This is the first robust indoor air quality data set developed for the UAE. This study demonstrates that screening level tools are a good initial step for assessing air quality when logistical issues (distance, language, cultural, training) and intrusion into personal lives need to be minimized.
基金Funded by Beijing Higher Education Young Elite Teacher Project(No.YETP0371)National Key Technologies R&D Program of China(No.2012BAJ02B02)
文摘The paper presents a simple model for outdoor air contaminant transmission into occupied rooms. In the model, several factors such as filtration, ventilation, deposition, re-emission, outdoor concentration and indoor sources are included. The model results show that the air exchange rate plays an important role in the transmission of outdoor contaminants into the indoor environment. The model shows that increasing the value of the filtration efficiency decreases the mass concentration of indoor particles. In addition, if outdoor aerosol particles have a periodic behaviour, indoor aerosol particles also behave periodically but smoother. Indoor sources are found to be able to increase indoor concentrations greatly and continuously.