期刊文献+
共找到12篇文章
< 1 >
每页显示 20 50 100
Monitoring of Air Quality for Particulate Matter (PM2.5, PM10) and Heavy Metals Proximate to a Cement Factory in Ewekoro, Nigeria
1
作者 Alaba Awos Shirley Thompson +2 位作者 Oludare Adedeji Francis Zvomuya Qiang Zhang 《Journal of Geoscience and Environment Protection》 2024年第10期152-180,共29页
A cement factory nearby communities raise pollution concerns. This study assessed air pollution levels for respirable particulate matter (PM2.5 and PM10) and heavy metals (lead, chromium, nickel, cadmium, zinc and cop... A cement factory nearby communities raise pollution concerns. This study assessed air pollution levels for respirable particulate matter (PM2.5 and PM10) and heavy metals (lead, chromium, nickel, cadmium, zinc and copper) adjacent to a cement factory in Ewekoro and neighbouring communities (Papalantoro, Lapeleko and Itori) in Ogun State, Nigeria. Respirable particulate matter (PM2.5 and PM10) and heavy metals were measured using an ARA N-FRM cassette sampler. Each location sampled was monitored for eight continuous hours daily for 12 days. The PM2.5, PM10 and heavy metals results were compared with different standards, including those of the World Health Organization (WHO), Nigeria’s National Environmental Standard and Regulation Enforcement Agency (NESREA) and Canadian Ambient Air Quality Standards (CAAQS). The PM levels fell within 11 - 19 μg/m3 of the air management level of CAAQS, which signifies continuous actions are needed to improve air quality in the areas monitored but below the NESREA standard. The mean Cd, Cr and Ni concentrations in the cement factory area and the impacted neighbourhoods are higher than the WHO/EU permissible limits, while Zn and Cu were below the WHO/EU permissible limit. A risk assessment hazard quotient (HQ) for Cr was above the WHO/EU safe level (=1) in adults and children throµgh ingestion, inhalation and dermal contact at all the monitoring sites. The HQ for Ni and Cd was higher than the safe level in the cement factory area and Papalantoro, while Zn was at safe levels. 展开更多
关键词 Particulate Matter Heavy Metals air Sampling Cement Factory Pollution Hazard Quotient CEMENT Industrial Pollution
下载PDF
Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters
2
作者 J. Matthew Barnett Hunter Z. Edwards 《Journal of Environmental Protection》 CAS 2022年第8期589-602,共14页
Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha an... Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg⋅cm<sup>-2</sup> mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg⋅cm<sup>-2</sup>) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg⋅cm<sup>-2</sup> correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg⋅cm<sup>-2</sup> (excluding negative values and outliers) and a range from 0 - 0.24 mg⋅cm<sup>-2</sup>, the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg⋅cm<sup>-2</sup> and less than 10% at 0.24 mg⋅cm<sup>-2</sup>. The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor. 展开更多
关键词 air Sampling Environmental Radioactivity SELF-ABSORPTION Correction Factor Standards
下载PDF
Solid phase microextraction(SPME) sampling under turbulent conditions and for the simultaneous collecting of tracer gases 被引量:1
3
作者 Underwood Susanne W. Jong Edmund C. +3 位作者 Luxbacher Kray D. Sarver Emily A. Ripepi Nino S. Mc Nair Harold M. 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第4期559-563,共5页
Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling... Solid phase microextraction (SPME) is a solvent-flee method of sample collection. SPME is an appealing method for sample collection because it is designed for the sampling of trace level analytes with short sampling times in a variety of environments. Additionally, SPME can be used to directly deliver a sample to a gas chromatograph (GC) for analysis by means of thermal desorption. In this paper, the performance of SPME under dynamic conditions was investigated. Additionally, the competence of SPME sampling for the simultaneous analysis of multiple trace analytes was also evaluated. This work is discussed in the context of underground mine ventilation surveys but is applicable to any industry in which ventilation circuits must be evaluated. The results of this paper showed that the performance of the 100 ~m PDMS SPME fiber was both precise and rapid under dynamic conditions. This SPME fiber was also able to simultaneously collect sulfur hexafluoride (SF6) and perfluoromethylcyclohexane (PMCH) with adequate sensitivity. 展开更多
关键词 Solid phase microextraction Sulfur hexafluoride Perfluoromethylcyclohexane Tracer gas Mine ventilation air sampling
下载PDF
Workplace Assessment of Naphtha Exposure in a Tyre Manufacturing Industry
4
作者 I. Norazura H. Zailina +3 位作者 L. Naingx N. Rusli H.H. Jamal J. Mohd. Hasni 《Journal of Environmental Science and Engineering》 2011年第4期400-409,共10页
A qualitative and quantitative workplace assessment was carried out to determine naphtha exposure in a tyre manufacturing industry. A qualitative chemical health risk assessment was conducted to identify naphtha hazar... A qualitative and quantitative workplace assessment was carried out to determine naphtha exposure in a tyre manufacturing industry. A qualitative chemical health risk assessment was conducted to identify naphtha hazard at the workplace. Quantitative assessment using Portable VOC Monitor, Automatic Sampling Pump and personal air sampling pump was used to determine VOC concentrations, organic solvents, and individual air naphtha respectively. The risk rating of naphtha was estimated to be 5. The mean VOC concentration was in the range of 2.43 to 92.93 ppm. Repair area had the highest VOC concentration while the lowest was in the moulding area. Each work station had significant differences for VOC concentrations (p 〈 0.001). Laboratory analysis found various solvents including 2-methyl pentane, hexane, methyl cyclopentane, heptane, cyclohexane and toluene which were present in the liquid naphtha. Only xylene has been detected in the making and moulding areas with a range of 2 to 5 ppm. Meanwhile, the air naphtha concentrations of the exposed workers were significantly higher than those unexposed. The risk of naphtha exposure was qualitatively significant and not adequately controlled. Naphtha was detected in all work stations since it is the main solvent used. The "Repair Area" was significantly more contaminated than the other area. 展开更多
关键词 Environmental monitoring risk assessment volatile organic compound (VOC) NAPHTHA personal air sampling
下载PDF
Sources and Trends of Persistent Organic Pollutants at Three Passive Monitoring Sites in South Africa
5
作者 Lloyd Shorai Pisa Nelson Mhlanga Patricia Mumbengengwi 《Journal of Geoscience and Environment Protection》 2020年第7期207-218,共12页
The Stockholm Convention on Persistent Organic Pollutants (SCPOPs) is an international treaty that operates under the patronage of the United Nations (UN) to control certain chemicals that are considered persistent or... The Stockholm Convention on Persistent Organic Pollutants (SCPOPs) is an international treaty that operates under the patronage of the United Nations (UN) to control certain chemicals that are considered persistent organic pollutants (POPs). They are of great concern because of their adverse effects on human health and the environment. Exposure to POPs may lead to cancer, infertility, respiratory infections, and other health complications. It is therefore critical to study the degree of human and environmental exposure to these POPs. Passive air sampling was conducted in South Africa to evaluate the presence and trends of persistent organic pollutants at Barberspan (rural agricultural), Vanderbijl Park (urban industrial) and Molopo Nature Reserve (isolated nature reserve). Samples were collected in 2012. Passive air samplers using poly were used for sampling. The Buchi System B-811 automatic extractor was used to analyze for dichloro-diphenyl-trichlorethane (DDT), pentachlorobenzene (PeCB), hexechlorobenzene (HCB) polychlorinated biphenyls (PCBs) and hexachlorocyclohexane (HCH). Sampling was conducted for a period of one year. POPs concentrations were generally low at all sites, but Vanderbijl Park had the highest concentrations. Seasonal changes in concentrations were much the same at the three sites with temperatures and wind patterns being major factors. The presence of these chemicals in Molopo Nature Reserve and Barberspan is evidence of long range transportation over dry semi desert areas. Back-trajectories indicate possible sources, including areas where DDT is used for malaria control. The presence of POPs is areas they have never been in use poses health and environmental risks in these areas. 展开更多
关键词 Persistent Organic Pollutants Passive air Sampling Long Range Transportation
下载PDF
Levels and Sources of Atmospheric Polycyclic Aromatic Hydrocarbons Surrounding an Oil Refinery in Curacao
6
作者 Erin L.Pulster Giffe Johnson +2 位作者 Dave Hollander James McCluskey Raymond Harbison 《Journal of Environmental Protection》 2019年第3期431-453,共23页
This research measured ambient levels of polycyclic aromatic hydrocarbons (PAHs) surrounding a petrochemical complex on the island of Curacao using passive air sampling. In addition, source elucidation of PAHs was con... This research measured ambient levels of polycyclic aromatic hydrocarbons (PAHs) surrounding a petrochemical complex on the island of Curacao using passive air sampling. In addition, source elucidation of PAHs was conducted using concentration profiles, distribution profiles, binary diagnostic ratios and factor analysis. Passive air samplers with polyurethane foam collection disks (PAS-PUFs) were deployed in 2011 (n = 43) and in 2014 (n = 30) to evaluate the extent of the emission plume as well as spatial and temporal differences in ambient PAH concentrations. In general, ambient PAH concentrations in Curacao were consistent with other urban and industrialized regions of the world;however, the levels measured downwind of Isla Refineriá petrochemical complex were among some of the highest reported ambient PAHs globally. Ambient PAH concentrations ranged from 1.2 to 790 ng/m3 in 2011 and 27 to 660 ng/m3 in 2014, demonstrating no temporal differences. However, significant spatial differences were detected between samples collected upwind and downwind of the petrochemical complex. Significantly higher ambient PAH concentrations were found in the samples collected downwind of the petrochemical complex compared to those upwind in 2014 展开更多
关键词 PETROCHEMICAL Polycyclic Aromatic Hydrocarbons Curacao Passive air Sampling Diagnostic Ratios
下载PDF
Effect of a portable ultra-clean exponential airflow unit on the particle distribution in an operating room 被引量:3
7
作者 Sasan Sadrizadeh Sture Holmberg 《Particuology》 SCIE EI CAS CSCD 2015年第1期170-178,共9页
The effects of a mobile laminar airflow unit on the concentration, deposition and distribution of bacteria- carrying particles in an operating room are investigated. The exploration is carried out using numerical calc... The effects of a mobile laminar airflow unit on the concentration, deposition and distribution of bacteria- carrying particles in an operating room are investigated. The exploration is carried out using numerical calculation schemes (computational fluid dynamics approach). The model validation was performed through result comparisons with published measurement data from literature. Two types of mobile screen units were evaluated as an extension of turbulent-mixing operating-room ventilation. Airborne particle concentration/sedimentation was recorded with and without a screen unit on the operating table and two instrument tables. Both active and passive air sampling were examined and the results are compared. It was found that the additional mobile ultra-clean laminar airflow unit reduces the counts of airborne bacteria and surface contamination to a level acceptable for infection-prone surgeries. 展开更多
关键词 Computational fluid dynamics Bacteria-carrying particle Surgical-site infection Hospital operating room air quality Active-passive air sampling
原文传递
Determination of 15 phthalate esters in air by gas-phase and particle-phase simultaneous sampling 被引量:7
8
作者 Chenchen Chi Meng Xia +3 位作者 Chen Zhou Xueqing Wang Mili Weng Xueyou Shen 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2017年第5期137-145,共9页
Based on previous research, the sampling and analysis methods for phthalate esters (PAEs) were improved by increasing the sampling flow of indoor air from 1 to 4 L/min, shortening the sampling duration from 8 to 2 h... Based on previous research, the sampling and analysis methods for phthalate esters (PAEs) were improved by increasing the sampling flow of indoor air from 1 to 4 L/min, shortening the sampling duration from 8 to 2 hr. Meanwhile, through the optimization of chromatographic conditions, the concentrations of 9 additional PAE pollutants in indoor air were measured. The optimized chromatographic conditions required a similar amount of time for analysis as before, but gave high responsivity, the capability of simultaneously distinguishing 15 kinds of PAEs, and a high level of discrimination between individual sample peaks, as well as stable peak generation. The recovery rate of all gas-phase and particle-phase samples of the 15 kinds of PAEs ranged from 91.26% to 109.42%, meeting the quantitative analysis requirements for indoor and outdoor air sampling and analysis. For the first time, investigation of the concentration levels as well as characteristics of 15 kinds of PAEs in the indoor air from four different traffic micro-environments (private vehicles, busses, taxis and subways) was carried out, along with validation of the optimized sampling and analytical method. The results show that all the 9 additional PAEs could be detected at relatively high pollution levels in the indoor air from the four traffic micro-environments. As none of the pollution levels of the 15 kinds of PAEs in the indoor air from the 4 traffic micro-environments should be neglected, it is of great significance to increase the types of PAEs able to be detected in indoor air. 展开更多
关键词 air pollution Phthalate esters Traffic micro-environment Gas-phase and particle-phase Sampling and analytical method
原文传递
Comparisons of indoor active and passive air sampling methods for emerging and legacy halogenated flame retardants in Beijing, China offices
9
作者 Seth Newton Ulla Sellströom +2 位作者 Stuart Harrad Gang Yu Cynthia A.de Wit 《Emerging Contaminants》 2016年第2期80-88,共9页
One active and two passive air sampling configurations were deployed simultaneously in three offices in Beijing,China to test their comparability for sampling emerging and legacy halogenated flame retardants spanning ... One active and two passive air sampling configurations were deployed simultaneously in three offices in Beijing,China to test their comparability for sampling emerging and legacy halogenated flame retardants spanning a large range of octanoleair partition coefficients(KOA).Sampling in each office was carried out for three consecutive 28-day periods in the spring-summer of 2013.The active sampler was run for 2.5 h at different times every day for 28 days to parallel the passive samplers and sample a total volume comparable to that sampled by the passive samplers(~20 m^3).At the end of each 28-day sampling period,a separate active air sample was taken by running the sampler pump continuously for about 2.5 days.The comparability of measured concentrations varied between the air sampling configurations and for different compounds.The predominant compound measured in nearly all samples was BDE-209,a compound known to have heavy use in China.Several emerging flame retardants were also detected including DBE-DBCH,PBT,HBB,DDC-CO,and DBDPE.Very little of the tetra-hexabrominated BDEs associated with the technical PentaBDE product was observed. 展开更多
关键词 Indoor air Passive air sampling Active air sampling Flame retardants Emerging flame retardants BFR
原文传递
Novel aerosol detection platform for SARS–CoV–2:Based on specific magnetic nanoparticles adsorption sampling and digital droplet PCR detection
10
作者 Hui Chen Xinye Ma +7 位作者 Xinyu Zhang Gui Hu Yan Deng Song Li Zhu Chen Nongyue He Yanqi Wu Zhihong Jiang 《Chinese Chemical Letters》 SCIE CAS CSCD 2023年第1期274-278,共5页
The SARS–CoV–2 virus is released from an infectious source(such as a sick person)and adsorbed on aerosols,which can form pathogenic microorganism aerosols,which can affect human health through airborne transmission.... The SARS–CoV–2 virus is released from an infectious source(such as a sick person)and adsorbed on aerosols,which can form pathogenic microorganism aerosols,which can affect human health through airborne transmission.Efficient sampling and accurate detection of microorganisms in aerosols are the premise and basis for studying their properties and evaluating their hazard.In this study,we built a set of sub-micron aerosol detection platform,and carried out a simulation experiment on the SARS–CoV–2 aerosol in the air by wet-wall cyclone combined with immunomagnetic nanoparticle adsorption sampling and ddPCR.The feasibility of the system in aerosol detection was verified,and the influencing factors in the detection process were experimentally tested.As a result,the sampling efficiency was 29.77%,and extraction efficiency was 98.57%.The minimum detection limit per unit volume of aerosols was 250 copies(102copies/m L,concentration factor 2.5). 展开更多
关键词 Aerosol detection air sampling Immunomagnetic nanoparticle ddPCR SARS–CoV–2
原文传递
Seasonal trend of ambient PCDD/Fs in Tianjin City, northern China using active sampling strategy 被引量:16
11
作者 Lei Ding Yingming Li +5 位作者 Pu Wang Xiaomin Li Zongshan Zhao Qinghua Zhang Ting Tuan Guibin Jiang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第11期1966-1971,共6页
The spatial concentrations, seasonal trends, profiles and congener pairs of ambient polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were investigated within a seasonally active ... The spatial concentrations, seasonal trends, profiles and congener pairs of ambient polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were investigated within a seasonally active sampling scheme during Jun 2008 and Jan 2009 in Tianjin City, northern China. The PCDD/F concentrations ranged 14.2-172 fg I-TEQ/m3 (average 69.3 fg I-TEQ/m3) in summer and (89.8-1.01) x 103 fg I-TEQ/m3 (average 509 fg I-TEQ/m3) in winter, respectively, except for the E-waste dismantling site where much higher values were observed (1.04 x 103 fg I-TEQ]m3 in summer and 7.123 x 103 fg I-TEQ/m3 in winter). The results indicated a significantly seasonal trend with higher TEQ values in winter as compared with summer, which could be related to increased emission sources and seasonal variations of the atmospheric boundary layer height. 2,3,4,7,8-PeCDF was the dominant contributor to the total PCDD/F toxic equivalents, and 2,3,7,8-TCDD was detected at almost all the sampling sites in winter. Most of the similarly substituted PCDD/F congener pairs exhibited high correlations, suggesting that they might have similar environmental fate or sources. But different seasonal and spatial distributions of PCDD/F concentrations indicated that the emission sources might be intermittent. 展开更多
关键词 PCDD/FS seasonal trend TIANJIN high-volume air sampling
原文传递
Human viral pathogens are pervasive in wastewater treatment center aerosols 被引量:7
12
作者 Evelyne Brisebois Marc Veillette +4 位作者 Vanessa Dion-Dupont Jacques Lavoie Jacques Corbeil AlexANDer Culley Caroline Duchaine 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第5期45-53,共9页
Wastewater treatment center(WTC) workers may be vulnerable to diseases caused by viruses, such as the common cold, influenza and gastro-intestinal infections. Although there is a substantial body of literature chara... Wastewater treatment center(WTC) workers may be vulnerable to diseases caused by viruses, such as the common cold, influenza and gastro-intestinal infections. Although there is a substantial body of literature characterizing the microbial community found in wastewater, only a few studies have characterized the viral component of WTC aerosols,despite the fact that most diseases affecting WTC workers are of viral origin and that some of these viruses are transmitted through the air. In this study, we evaluated in four WTCs the presence of 11 viral pathogens of particular concern in this milieu and used a metagenomic approach to characterize the total viral community in the air of one of those WTCs. The presence of viruses in aerosols in different locations of individual WTCs was evaluated and the results obtained with four commonly used air samplers were compared.We detected four of the eleven viruses tested, including human adenovirus(h Ad V),rotavirus, hepatitis A virus(HAV) and Herpes Simplex virus type 1(HSV1). The results of the metagenomic assay uncovered very few viral RNA sequences in WTC aerosols, however sequences from human DNA viruses were in much greater relative abundance. 展开更多
关键词 airborne viruses air sampling Wastewater treatment plants Viral metagenomics
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部