Development and Experimental Study of Air Source Heat Pump Water Heater 被引量:2
1
作者 李海峰 蔡正云 《Meteorological and Environmental Research》 CAS 2010年第2期100-102,共3页
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul... The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water. 展开更多
关键词 air source heat pump water heater China
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
2
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 air source heat pump system(ASHPS) space heating defrosting parameter COP
下载PDF
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
3
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
4
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
5
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
下载PDF
Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens 被引量:4
6
作者 LIU Zhong-bing,ZHANG Ling,YANG Zhang,XU Ming,HAN Tian-he(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期131-135,共5页
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff... A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient. 展开更多
关键词 THERMOELECTRIC heat pump KITCHENS EXHAUST water heater COEFFICIENT of performance
下载PDF
Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump 被引量:7
7
作者 董建锴 姜益强 +1 位作者 姚杨 张雪丹 《Journal of Central South University》 SCIE EI CAS 2011年第6期2163-2169,共7页
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho... To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting. 展开更多
关键词 air source heat pump thermal energy storage phase change material reverse-cycle defrosting
下载PDF
Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System 被引量:1
8
作者 SU Shun-yu,ZHANG Chun-zhi,CHEN Jian(College of Urban Construction,Wuhan University of Science and Technology,Wuhan,Hubei 430070,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期91-95,共5页
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.... This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary. 展开更多
关键词 air-source heat pump control strategy distributed PARAMETER model CHARGE INVENTORY
下载PDF
Study on corrosion behavior of heat exchanger in water source heat pump
9
作者 刘作华 龙洋 +2 位作者 李百战 丁勇 周小霞 《化工进展》 EI CAS CSCD 北大核心 2010年第S1期695-698,共4页
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T... Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value. 展开更多
关键词 water source heat pump water quality RIVER water corrosion
下载PDF
Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump
10
作者 Satoshi Yoshida Ryozo Ooka +1 位作者 Toshiyuki Hino Kazuo Kodama 《Journal of Energy and Power Engineering》 2014年第10期1703-1711,共9页
Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi... Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi-use heat pump) to achieve higher efficiency than traditional systems. The MMHP system connects multiple heat sources such as solar heat, the ground, and air and multiple heat uses such as cooling, heating, and a hot water dispenser with a water loop. Each type of heat use side can utilize heat efficiently. However, there is a distinct lack of highly efficient hot water dispensers available. Therefore, we developed the IHWD WS (instantaneous hot water dispenser based on a water source) heat pump. In this study, we developed a prototype of the IHWD WS heat pump. The coefficient of performance of the IHWD WS heat pump was 5.2-8.5 throughout a year. When it is improved, COP (coefficient of performance) is expected to be 9.3-9.9. 展开更多
关键词 heat pumps hot water EFFICIENCY COP ground source.
下载PDF
Numerical and Experimental Study on Dynamic Performance of Heat Pump Water Heater with Electronic Expansion Valve
11
作者 Liang Zhang Xianmin Guo Weiguo Li Weihua Wang 《Journal of Energy and Power Engineering》 2012年第10期1582-1588,共7页
A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capac... A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%. 展开更多
关键词 heat pump water heater electronic expansion valve experimental investigation simulation.
下载PDF
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
12
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:2
13
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 air-Cooled heat pump Unit Compound Condensation Process (CCP) Exergy Analysis Method Sanitary Hot water MATLAB/SIMULINK Software Fluorine SUBSTITUTE REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
Performance analysis of air-water dual source heat pump water heater with heat recovery 被引量:9
14
作者 CHEN ZeShao TAO WenQuan +1 位作者 ZHU YanWen HU Peng 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第8期2148-2156,共9页
A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre... A new air-water dual source heat pump water heater with heat recovery is proposed.The heat pump system can heat water by using a single air source,a single water source,or air-water dual sources.The water is first pre-heated by waste hot water,then heated by the heat pump.Waste heat is recovered by first preheating the cold water and as water source of the heat pump.According to the correlated formulas of the coefficient of performance of air-source heat pump and water-source heat pump,and the gain coefficient of heat recovery-preheater,the formulas for the coefficient of performance of heat pump in six operating modes are obtained by using the dimensionless correspondence analysis method.The system characteristics of heat absorption and release associated with the heat recovery-preheater are analyzed at different working conditions.The developed approaches can provide reference for the optimization of the operating modes and parameters.The results of analysis and experiments show that the coefficient of performance of the device can reach 4-5.5 in winter,twice as much as air source heat pump water heater.The utilization of waste heat in the proposed system is higher than that in the system which only uses waste water to preheating or as heat source.Thus,the effect of energy saving of the new system is obvious.On the other hand,the dimensionless correspondence analysis method is introduced to performance analysis of the heat pump,which also has theoretical significance and practical value. 展开更多
关键词 heat pump water heater waste heat recovery dual source heat pump correspondence analysis method performance analysis
原文传递
Experimental Study of Energy-Saving Air-Conditioner with Hot Water
15
作者 CHEN Jian-bo,CHEN Dan,LU Ying(University of Shanghai for Science and Technology,Shanghai,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期75-78,共4页
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in seri... Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters. 展开更多
关键词 air-CONDITIONING water heaterS energy CONSERVATION heat pump systems thermal efficiency
下载PDF
Data-driven sensitivity analysis and electricity consumption prediction for water source heat pump system using limited information 被引量:1
16
作者 Shaobo Sun Huanxin Chen 《Building Simulation》 SCIE EI CSCD 2021年第4期1005-1016,共12页
The studies on predicting the energy consumption of air conditioning systems are meaningful to building energy conservation and management. Generally, the more comprehensive the building information is, the easier the... The studies on predicting the energy consumption of air conditioning systems are meaningful to building energy conservation and management. Generally, the more comprehensive the building information is, the easier the prediction model can be developed. However, it is very difficult to get detailed information about existing/old buildings (information-poor buildings), it is a big challenge to predict the energy consumption accurately by limited information. This study aims to predict the electricity consumption of the water source heat pump system of an office building based on meteorological data. The key variables are selected by error analysis and sensitivity analysis, and the effects of each variable on the models’ prediction performance can be obtained. Besides, the prediction models are established by support vector regression algorithm and trained by the local meteorological data. The results show that the positive and negative variables can be identified, and these positive variables are responsible for more than 70% of the total importance. Moreover, the root mean square error falls to 4.6044 from 7.8227 and the relative square error falls to 0.1494 from 0.4313 when the negative inputs are removed. And the errors reduce further to 4.1160 and 0.1194 by parameter optimization. 展开更多
关键词 water source heat pump electricity consumption support vector regression PREDICTION sensitivity analysis parameter optimization
原文传递
Water pumping analysis and experimental validation of beach well infiltration intake system in a seawater source heat pump system
17
作者 Huan ZHANG Shu LIU +1 位作者 Xuejing ZHENG Gaofeng CHEN 《Frontiers in Energy》 SCIE CSCD 2015年第3期335-342,共8页
Based on energy conservation equation and Darcy's law, a model of beach well infiltration intake system applied in a seawater source heat pump system was established. The model consists of the seawater seepage and th... Based on energy conservation equation and Darcy's law, a model of beach well infiltration intake system applied in a seawater source heat pump system was established. The model consists of the seawater seepage and the heat transfer process. A porous medium model in a software named FLUENT was applied to simulate the seepage and the heat transfer process. This model was also validated by field experiment conducted on the seashore in Tianjin, China. The maximum relative error between simulation results and experimental results was 2.1% (less than 5%), which was acceptable in engineering applica- tion. The porosity and coefficient of thermal conductivity of the aquifer soil were determined to be 0.49 W/(m. K) and 1.46W/(m.K), respectively in the simulation. In addition, the influencing factors of pumping water of beach well were also analyzed. The pumping water was found to increase when the distance between the beach well and the impervious boundary becomes longer, when the distance between the beach well and the supplying water source shortens, when the diameter of the beach well enlarges, and the drawdown enlarges. 展开更多
关键词 water pumping analysis experimental valida-tion infiltration intake system seawater source heat pump
原文传递
基于FLOW HEAT的地下水源热泵一抽多灌井群优化布置数值研究 被引量:2
18
作者 周强 王楠 《水电能源科学》 北大核心 2019年第9期124-127,共4页
为研究一抽多灌井群的最佳布置方式,基于FLOW HEAT软件,将抽水井附近的灌水井群采用集中环绕型、直线型等8种不同布置方式建立数学模型,分析抽水井水温变化规律、温度和渗流场及最佳井距。结果表明,采用以抽水井为中心回灌井环绕布置方... 为研究一抽多灌井群的最佳布置方式,基于FLOW HEAT软件,将抽水井附近的灌水井群采用集中环绕型、直线型等8种不同布置方式建立数学模型,分析抽水井水温变化规律、温度和渗流场及最佳井距。结果表明,采用以抽水井为中心回灌井环绕布置方式时井群影响范围较小,渗流效果也较好,但抽水井水温较高易发生热贯通现象;采用直线型布置方式时抽水井水温变化较慢、井群渗流效果一般;井群水温随井距的增加逐渐降低。综合考虑,抽水井在回灌井中间的直线型布置且井距为51.63m为最佳布置方式。 展开更多
关键词 地下水源热泵 一抽多灌 井距 FLOW heat 数值研究
下载PDF
Heating performance of a ground source heat pump system installed in a school building 被引量:5
19
作者 Jaedo SONG Kwangho LEE +5 位作者 Youngman JEONG Seongir CHEONG Jaekeun LEE Yujin HWANG Yeongho LEE Donghyuk LEE 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第1期80-84,共5页
The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter seas... The heating performance of a water-to-refrigerant type ground source heat pump system is represented in this paper under the actual working conditions of the GSHP(ground source heat pump) system during the winter season of 2008.Ten heat pump equipments with the capacity of 10 HP each and a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth were constructed.We investigated a variety of working conditions,including the outdoor temperature,the ground temperature,and the water temperature of inlet and outlet of the ground heat exchanger in order to examine the heating performance of the GSHP system.Subsequently,the heating capacity and the input power were investigated to determine the heating performance of the GSHP system.The average heating coefficient of performance(COP) of the heat pump was noted to be 5.1 at partial load of 47%,while the overall system COP was found to be 4.2.Also,performance of the GSHP system was compared with that of air source heat pump. 展开更多
关键词 ground source heat pump(GSHP) water-to-refrigerant heating PERFORMANCE coefficient of performance(COP) air source heat pump(ASHP)
原文传递
Dynamic Simulation and Performance Analysis on Multi-Energy Coupled CCHP System
20
作者 Xueqin Tian Jinfei Sun +5 位作者 Tong Xu Mengran Cui Xinlei Wang Jianxiang Guo De-gejirifu Na Wang 《Energy Engineering》 EI 2022年第2期723-737,共15页
Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matchi... Although the Combined Cooing,Heating and Power System(hereinafter referred to as“CCHP”)improves the capacity utilization rate and energy utilization efficiency,single use of CCHP system cannot realize dynamic matching between supply and demand loads due to the unbalance features of the user’s cooling and heating loads.On the basis of user convenience and wide applicability of clean air energy,this paper tries to put forward a coupled CCHP system with combustion gas turbine and ASHP ordered power by heat,analyze trends of such parameters as gas consumption and power consumption of heat pump in line with adjustment of heating load proportion of combustion gas turbine,and optimize the system ratio in the method of annual costs and energy environmental benefit assessment.Based on the analysis of the hourly simulation and matching characteristics of the cold and hot load of the 100 thousand square meter building,it is found that the annual cost of the air source heat pump is low,but the energy and environmental benefits are poor.It will lead to 6.35%shortage of cooling load in summer.Combined with the evaluation method of primary energy consumption and zero carbon dioxide emission,the coupling system of CHHP and air source heat pump with 41%gas turbine load ratio is the best configuration.This system structure and optimization method can provide some reference for the development of CCHP coupling system. 展开更多
关键词 CCHP(Combined Cooling heating and Power system) ASHP(air source heat pump) annual costs absorption cooling transient simulation
下载PDF