This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an ...This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%).展开更多
Objective To analyze the factors that impact the environment quality of cleaning operating room and to discuss improvement measurement. Methods Environment bacteria testing results and prevalence of surgical incision ...Objective To analyze the factors that impact the environment quality of cleaning operating room and to discuss improvement measurement. Methods Environment bacteria testing results and prevalence of surgical incision infection in cleaning operating room were retro-展开更多
The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowle...The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.展开更多
A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va...A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.展开更多
To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three...To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.展开更多
Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multiv...Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multivariable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified 10 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control.展开更多
Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling lo...Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant.展开更多
The estuary and coastal zone are the key areas for socio-economic development,and they are also the important channels for pollutants transported to the sea.The construction of the Jiaozhou Bay Bridge changed the hydr...The estuary and coastal zone are the key areas for socio-economic development,and they are also the important channels for pollutants transported to the sea.The construction of the Jiaozhou Bay Bridge changed the hydrodynamic condition of the bay,which made the self-purification capacity of the bay weakened and the pollution in the estuary and adjacent coastal zone become more serious.In this study,55 surface sediment samples were collected from the three seriously polluted estuaries and the adjacent coastal zone of Jiaozhou Bay to comprehensively study how the benthic foraminifera response to heavy metal pollution and human engineering,and to assess the ecological risks of the bay.A total of 80 species,belonging to 42 genera,were identified in this study.The results showed that Cu,Pb,Cr,Hg,Zn,and As had low to median ecological risks in the study area which would definitely affect the ecological system.The construction of the Jiaozhou Bay Bridge has resulted in pollutants accumulated at the river mouth of Loushan River,which has adverse effects on the survival and growth of benthic foraminifera.The lowest population density and diversity as well as the highest FAI(Foraminiferal Abnormality Index)and FMI(Foraminiferal Monitoring Index)occurred at Loushan River Estuary which indicated that the ecological environment of the northeastern part of Jiaozhou Bay(Loushan River Estuary)had been seriously damaged.Licun River and Haipo River estuaries and the adjacent coastal zone were slightly polluted and had low ecological risk.As a consequence,it suggested that the supervision of industrial and domestic waste discharge and the protection of the ecological environment in northeast Jiaozhou Bay should be paid more attention.展开更多
AIM: To examine the effect of the potential interaction between KIF1 B variants(rs17401966 and rs3748578) and environmental factors on the risk of hepatocellular carcinoma(HCC) in a high-risk region in China.METHODS: ...AIM: To examine the effect of the potential interaction between KIF1 B variants(rs17401966 and rs3748578) and environmental factors on the risk of hepatocellular carcinoma(HCC) in a high-risk region in China.METHODS: Three hundred and six patients with HCC and 306 hospital-based control participants residing in the Shunde region of Guangdong Province, China were enrolled. Clinical characteristics were collected by reviewing the complete medical histories from the patient archives, and epidemiological data were collected using a questionnaire and clinical examination. Two single nucleotide polymorphisms(SNPs) of KIF1B(rs17401966 and rs3748578) were chosen for the current study. All subjects were genotypedusing a Taq Man real-time polymerase chain reaction. Multiplicative and additive logistic regression models were used to evaluate various gene-environment interactions.RESULTS: Smoking, frequent consumption of raw freshwater fish, hepatitis B virus(HBV) infection, and a family history of HCC were important risk factors for HCC in this population. Chronic infection with HBV was the most important environmental risk factor for HCC [odds ratio(OR) = 12.02; 95% confidence interval(95%CI): 6.02-24.00]. No significant association was found between the KIF1 B variants alone and the risk of HCC. Nevertheless, a significant additive effect modification was observed between rs17401966 and alcohol consumption(P for additive interaction = 0.0382). Compared with non-drinkers carrying either the AG or GG genotype of rs17401966, individuals classified as alcohol consumers with the AA genotype of rs17401966 had a significantly increased risk of HCC(OR = 2.36; 95%CI: 1.49-3.74).CONCLUSION: The gene-environment interaction between the KIF1 B rs17401966 variant and alcohol consumption may contribute to the development of HCC in Chinese individuals.展开更多
The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different ...The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD).展开更多
An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature con...An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy.展开更多
Use of Electronic gadgets such as mobile phones, computers/laptops constitutes an integral part of human day-to-day activity in offices and businesses. Therefore, their use cannot be stopped. These electronic gadgets ...Use of Electronic gadgets such as mobile phones, computers/laptops constitutes an integral part of human day-to-day activity in offices and businesses. Therefore, their use cannot be stopped. These electronic gadgets emit electromagnetic radiations, which are believed to be hazardous to human health. World Health Organization/International Agency for Research on Cancer has classified radiofrequency electromagnetic fields as possibly carcinogenic to humans (Group B). The Enviro Chip developed by Synergy Environics, India, is a radiation harmonizing chip which when fixed on electronic gadgets at specific locations claims to reduce stress level by reducing the pulse rate of users which may also result in improvement of other health parameters. In this study, we have tested the ability of the Enviro Chip to reduce pulse rate of people who may have developed high pulse rate due to prolonged use of electronic gadgets. This was the double blind crossover study conducted in 205 healthy volunteers having an average pulse rate of above 82 per Minute at Max Healthcare India. The primary objective of the study was to evaluate and compare the change in pulse rate over 14 measurements with the use of both the Enviro Chip and a Dummy chip from average pulse rate at baseline without the Placebo effect. The secondary objective was to evaluate the change in pulse rate gender-wise. Data analysis was done using Wilcoxon Sign Rank test. The study demonstrated statistical significant reduction in pulse rate over 14 measurements with the use of Enviro Chip in both male and female healthy volunteers展开更多
As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possi...As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product de- signing.Lots of information in the process of this research is fuzzy and uncertain,but traditional QFD can not deal with it well. Fuzzy theory can solve the problem.So a fuzzy model for analyzing product competitive power is formulated in this paper to im- prove traditional QFD,after that it is applied to analyze air-conditioning competitive power.When air-conditioning competitive power is analyzed using this model,firstly the importance weight of the customer requirements o fair-conditioning is determined us- ing the Analytic Hierarchy Process (AHP) weighting process,then air-conditloning competitive power is evaluated using fuzzy comprehensive evaluation.It is proved that the model is feasible and has good applicability.展开更多
Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in seri...Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.展开更多
An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study inv...An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study investigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning system was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrigeration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0 ℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experimental data.展开更多
The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Differen...The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Different control methods of AACS are discussed through simulation based on this model. The result shows that the neural- fuzzy control is the best one compared with the on-off control and conventional fuzzy control method.It can make the compartment's temperature descend rapidly to the designed temperature and the fluctuation is small.展开更多
Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipmen...Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.展开更多
Based on analysis of the reason and process of condensation on ceiling radiant cooling panels, two kinds of arrangement of detectors are put forward. The physical model is established, the results show that detectors ...Based on analysis of the reason and process of condensation on ceiling radiant cooling panels, two kinds of arrangement of detectors are put forward. The physical model is established, the results show that detectors are arranged as the form of triangle is more suitable. It can not only satisfy the use requirement but also it is economical and practical. Finally we can conclude that the inlet water temperature 0.5°C higher than dew point temperature is safe and reliable.展开更多
基金Supported by Program of Science and Technology of Hunan Province(2007FJ2006)Project the Program of Science and Tech-nology of Hunan Province(2007TP4030)Hunan Provincial Natural Science Foundation of China(08JJ3093)
文摘This paper presented an entropy evaluation method for the influences of condense heat recovery system on the environment.Aiming at the damage of the condense heat to the environment,an entropy of resource loss and an emission entropy from the condense heat recovery system in the air conditioning refrigerating machine were introduced.For the evaluation of the entropies,we developed a new algorithm for the parameter identification,called the composite influence coefficient,based on the Least Squares Support Vector Machine method.By simulation,the numerical experiments shows that the Least Squares Support Vector Machine method is one of the powerful methods for the parameter identification to compute the damage entropy of the condense heat,with the largest training error being-0.025(the relative error being-3.56%),and the biggest test error being 0.015(the relative error being 2.5%).
文摘Objective To analyze the factors that impact the environment quality of cleaning operating room and to discuss improvement measurement. Methods Environment bacteria testing results and prevalence of surgical incision infection in cleaning operating room were retro-
文摘The knowledge representation mode and inference control strategy were analyzed according to the specialties of air-conditioning cooling/heating sources selection. The constructing idea and working procedure for knowledge base and inference engine were proposed while the realization technique of the C language was discussed. An intelligent decision support system (IDSS) model based on such knowledge representation and inference mechanism was developed by domain engineers. The model was verified to have a small kernel and powerful capability in list processing and data driving, which was successfully used in the design of a cooling/heating sources system for a large-sized office building.
文摘A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.
基金Project(50838009) supported by the National Natural Science Foundation of ChinaProjects(2006BAJ02A09,2006BAJ02A13-4) supported by the National Key Technologies R & D Program of China
文摘To explore the relationship between summer office set air-conditioning temperature and energy consumption related to air conditioning use to provide human thermal comfort,a comparison experiment was conducted in three similar offices at temperatures of 24,26 and 28 ℃ respectively. A thermal comfort questionnaire survey was conducted. It is demonstrated that air-conditioner energy consumption at the set temperature of 28 ℃ is 113% and 271% lower than at 26 ℃ and 24 ℃,respectively. A linear relationship exists between air-conditioner energy consumption and the indoor and outdoor temperature difference. When comfortably dressed,over 80% of research participants accept the set temperature of 28 ℃. The regression analysis leads to a neutral temperature of 26.2 ℃ and an acceptable temperature of 28.2 ℃ for over 80% of the research participants subjects,indicating that the current 26 ℃ set temperature for offices in summer,required by Chinese General Office of the State Council,can be increased to 28 ℃. Moreover,analysis of predicted mean vote(PMV) index shows that a set temperature of 27 ℃,not 26 ℃,is sufficiently comfortable for office staff wearing long-sleeve shirts,long pants and leather shoes.
基金Supported by Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of Ministry of Education of China
文摘Variable-air-volume (VAV) air-conditioning system is a multi-variable system and has multi coupling control loops. While all of the control loops are working together, they interfere and influence each other. A multivariable decoupling PID controller is designed for VAV air-conditioning system. Diagonal matrix decoupling method is employed to eliminate the coupling between the loop of supply air temperature and that of thermal-space air temperature. The PID controller parameters are optimized by means of an improved genetic algorithm in floating point representations to obtain better performance. The population in the improved genetic algorithm mutates before crossover, which is helpful for the convergence. Additionally the micro mutation algorithm is proposed and applied to improve the convergence during the later evolution. To search the best parameters, the optimized parameters ranges should be amplified 10 times the initial ideal parameters. The simulation and experiment results show that the decoupling control system is effective and feasible. The method can overcome the strong coupling feature of the system and has shorter governing time and less over-shoot than non-optimization PID control.
文摘Two building factors-a longer thermal lag of more than one hour for building envelops and a lag of indoor radiation to convert into cooling load-have impact on the instantaneous heat input and instantaneous cooling load.So the two factors should be taken into account when selecting the weather parameters for air-conditioning system design.This paper developed a new statistic method for the rational selection of coincident solar irradiance,dry-bulb and wet-bulb temperatures.The method was applied to historic weather records of 25 years in Hong Kong to generate coincident design weather data.And the results show that traditional design solar irradiance,dry-bulb and wet-bulb temperatures may be significantly overestimated in many conditions,and the design weather data for the three different constructions is not kept constant.
基金funded by the National Natural Science Foundation of China(41376079,41276060)the projects of the China Geological Survey and the Marine Geology Survey(DD20160137,DD20190205 and GZH200900501)+1 种基金the Foundation of the Shandong Provincial Key Laboratory of Marine Ecology and Environment&Disaster Prevention(201304)the Student Research Developing Program(SRDP)of Ocean University of China。
文摘The estuary and coastal zone are the key areas for socio-economic development,and they are also the important channels for pollutants transported to the sea.The construction of the Jiaozhou Bay Bridge changed the hydrodynamic condition of the bay,which made the self-purification capacity of the bay weakened and the pollution in the estuary and adjacent coastal zone become more serious.In this study,55 surface sediment samples were collected from the three seriously polluted estuaries and the adjacent coastal zone of Jiaozhou Bay to comprehensively study how the benthic foraminifera response to heavy metal pollution and human engineering,and to assess the ecological risks of the bay.A total of 80 species,belonging to 42 genera,were identified in this study.The results showed that Cu,Pb,Cr,Hg,Zn,and As had low to median ecological risks in the study area which would definitely affect the ecological system.The construction of the Jiaozhou Bay Bridge has resulted in pollutants accumulated at the river mouth of Loushan River,which has adverse effects on the survival and growth of benthic foraminifera.The lowest population density and diversity as well as the highest FAI(Foraminiferal Abnormality Index)and FMI(Foraminiferal Monitoring Index)occurred at Loushan River Estuary which indicated that the ecological environment of the northeastern part of Jiaozhou Bay(Loushan River Estuary)had been seriously damaged.Licun River and Haipo River estuaries and the adjacent coastal zone were slightly polluted and had low ecological risk.As a consequence,it suggested that the supervision of industrial and domestic waste discharge and the protection of the ecological environment in northeast Jiaozhou Bay should be paid more attention.
文摘AIM: To examine the effect of the potential interaction between KIF1 B variants(rs17401966 and rs3748578) and environmental factors on the risk of hepatocellular carcinoma(HCC) in a high-risk region in China.METHODS: Three hundred and six patients with HCC and 306 hospital-based control participants residing in the Shunde region of Guangdong Province, China were enrolled. Clinical characteristics were collected by reviewing the complete medical histories from the patient archives, and epidemiological data were collected using a questionnaire and clinical examination. Two single nucleotide polymorphisms(SNPs) of KIF1B(rs17401966 and rs3748578) were chosen for the current study. All subjects were genotypedusing a Taq Man real-time polymerase chain reaction. Multiplicative and additive logistic regression models were used to evaluate various gene-environment interactions.RESULTS: Smoking, frequent consumption of raw freshwater fish, hepatitis B virus(HBV) infection, and a family history of HCC were important risk factors for HCC in this population. Chronic infection with HBV was the most important environmental risk factor for HCC [odds ratio(OR) = 12.02; 95% confidence interval(95%CI): 6.02-24.00]. No significant association was found between the KIF1 B variants alone and the risk of HCC. Nevertheless, a significant additive effect modification was observed between rs17401966 and alcohol consumption(P for additive interaction = 0.0382). Compared with non-drinkers carrying either the AG or GG genotype of rs17401966, individuals classified as alcohol consumers with the AA genotype of rs17401966 had a significantly increased risk of HCC(OR = 2.36; 95%CI: 1.49-3.74).CONCLUSION: The gene-environment interaction between the KIF1 B rs17401966 variant and alcohol consumption may contribute to the development of HCC in Chinese individuals.
文摘The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD).
文摘An energy-saving control strategy based on predictive control for central air-conditioning systems is proposed in this paper. The cold load model is developed to describe the dynamic characteristics of temperature control systems, and then parameters in the cold load model and in the central air-conditioning system model are estimated. Generalized predictive control (GPC) is used to establish an optimization model to minimize the consumption of energy and the control error of temperature. The simulated annealing (SA) algorithm, combined with quadratic programming, is adopted to solve the optimal problem. Contrasted with the simulation of traditional PID control, the results prove the effectiveness of this proposed strategy.
文摘Use of Electronic gadgets such as mobile phones, computers/laptops constitutes an integral part of human day-to-day activity in offices and businesses. Therefore, their use cannot be stopped. These electronic gadgets emit electromagnetic radiations, which are believed to be hazardous to human health. World Health Organization/International Agency for Research on Cancer has classified radiofrequency electromagnetic fields as possibly carcinogenic to humans (Group B). The Enviro Chip developed by Synergy Environics, India, is a radiation harmonizing chip which when fixed on electronic gadgets at specific locations claims to reduce stress level by reducing the pulse rate of users which may also result in improvement of other health parameters. In this study, we have tested the ability of the Enviro Chip to reduce pulse rate of people who may have developed high pulse rate due to prolonged use of electronic gadgets. This was the double blind crossover study conducted in 205 healthy volunteers having an average pulse rate of above 82 per Minute at Max Healthcare India. The primary objective of the study was to evaluate and compare the change in pulse rate over 14 measurements with the use of both the Enviro Chip and a Dummy chip from average pulse rate at baseline without the Placebo effect. The secondary objective was to evaluate the change in pulse rate gender-wise. Data analysis was done using Wilcoxon Sign Rank test. The study demonstrated statistical significant reduction in pulse rate over 14 measurements with the use of Enviro Chip in both male and female healthy volunteers
文摘As the conceptual design of air-conditioning is done using the theory of Quality Function Deployment (QFD),cus- tomer requirements should be understood and the product competitive power be analyzed as exactly as possible for new product de- signing.Lots of information in the process of this research is fuzzy and uncertain,but traditional QFD can not deal with it well. Fuzzy theory can solve the problem.So a fuzzy model for analyzing product competitive power is formulated in this paper to im- prove traditional QFD,after that it is applied to analyze air-conditioning competitive power.When air-conditioning competitive power is analyzed using this model,firstly the importance weight of the customer requirements o fair-conditioning is determined us- ing the Analytic Hierarchy Process (AHP) weighting process,then air-conditloning competitive power is evaluated using fuzzy comprehensive evaluation.It is proved that the model is feasible and has good applicability.
基金Supported by Leading Academic Discipline Project of Shanghai Municipal Education Commission(J50502)
文摘Energy-saving air-conditioner with hot water is an air source heat pump air-conditioner,which can also supply hot water.The hot water is heated by a double pipe condenser connected with an air-cooled condenser in series in the system.This experiment of the energy-saving air-conditioner was carried out in the enthalpy-difference air-conditioner laboratory.The hot water temperature and the compressor's discharge and suction pressure were recorded in the working condition,where the ambient temperature was at 43 ℃,35 ℃,21 ℃,7 ℃,and 2 ℃ separately.The results showed that the system operated stably and reliably.This system can supply 240 L hot water at 50 ℃ in the whole year,and its coefficience of performance(COP)is much higher than the conventional air source heat pump system.Its energy conservation was proved by comparing the thermal efficiency with other sourece water heaters.
基金Supported by the National Basic Research Program of China("973"Program,No.2009CB219907)
文摘An explosion-proof dual throttling air-conditioning system was put forward to solve the heat dissipation and internal dewing problems of explosion-proof frequency converter in the underground coal mine. This study investigated the feasibility and benefits of explosion-proof dual throttling cooling and dehumidification air-conditioning system applied to the explosion-proof frequency converter. The physical model of dual throttling air-conditioning system was established and its performance parameter was described by mathematical method. The design calculation of the system has also been done. The experimental result showed that the system reached the steady state at the refrigeration mode after running 45 min, and the maximum internal temperature of the flame-proof cavity was 31.0 ℃. The system reached the steady state at the dehumidification mode after running 37 min. The maximum internal relative humidity and temperature of the flame-proof cavity were 33.4% and 36.3 ℃, respectively. Therefore, the proposed system had excellent ability of heat dissipation and avoided internal dewing. Compared with water cooling system, it was more energy-saving and economical. The airflow field of dual throttling air-conditioning system was also studied by CFD simulation. It was found that the result of CFD numerical simulation was highly consistent with the experimental data.
文摘The artificial intelligence is applied to the simulation of the automotive air-conditioning system ( AACS )According to the system's characteristics a model of AACS, based on neural network, is developed. Different control methods of AACS are discussed through simulation based on this model. The result shows that the neural- fuzzy control is the best one compared with the on-off control and conventional fuzzy control method.It can make the compartment's temperature descend rapidly to the designed temperature and the fluctuation is small.
基金Project(2011B061200043)supported by the Guangdong Provincial Department of Science and Technology,China
文摘Energy performance assessment on central air-conditioning system is essential to optimize operating, reduce operating costs, improve indoor environmental quality, and determine whether the retrofitting of the equipment is necessary. But it is difficult to evaluate it reasonably and comprehensively due to its complexity. A "holistic" approach was discussed to evaluate the energy performance of central air-conditioning system for an extra-large commercial building in a subtropical city. All procedures were described in detail, including field investigation method, field measurement instruments, data processing and data analyzing. The main factors affecting energy consumption of air-conditioning system were analyzed and the annual cooling-energy use intensity of this building was calculated and also compared with other shopping malls and other types of buildings in Guangzhou. And COP(coefficient of performance) of chiller, water transfer factor of chilled water system and cooling water system were taken into consideration. At last, the thermal comfort and indoor air quality issues were addressed. The results show that the chilled water pumps are over-sized and the indoor environmental quality should be improved. The purpose of this work is to provide reference for energy performance assessment method for air-conditioning system.
文摘Based on analysis of the reason and process of condensation on ceiling radiant cooling panels, two kinds of arrangement of detectors are put forward. The physical model is established, the results show that detectors are arranged as the form of triangle is more suitable. It can not only satisfy the use requirement but also it is economical and practical. Finally we can conclude that the inlet water temperature 0.5°C higher than dew point temperature is safe and reliable.