期刊文献+
共找到26篇文章
< 1 2 >
每页显示 20 50 100
Research and Demonstration of Direct Air-Cooling System for 600-MW Fossil-Fired Power Plants
1
作者 Zhang Xiaolu 1 , Wang Jianping 2 , Hu Zhenling 3 1. China Power Investment Corporation 2. China Power Engineering Consulting Group Corporation 3. Harbin Air Conditioning Co., Ltd., 《Electricity》 2011年第4期46-51,共6页
Given the distribution feature of resources such as coal and water, the requirements for the development of Chinese power industry, and the fact of monopoly by foreign companies, it is very necessary and significant t... Given the distribution feature of resources such as coal and water, the requirements for the development of Chinese power industry, and the fact of monopoly by foreign companies, it is very necessary and significant to independently research and develop air-cooling technologies. Through experimental research, simulative calculation, process and equipment development, field tests and a demonstration project, the design and operation technologies for air-cooling system are grasped and relevant key equipment is developed. The results of the demonstration project show that the technical indicators for the air-cooling system have met or exceeded the design requirements. Part of the research results have been incorporated into the relevant national design standards. The technologies developed have been applied to more than 23 sets of thermal power units of or above 600 MW in China. 展开更多
关键词 thermal power generating unit air-cooling direct air-cooling project demonstration
下载PDF
Thermal Management of Air-Cooling Lithium-Ion Battery Pack 被引量:5
2
作者 杜江龙 陶浩兰 +3 位作者 陈育新 袁小冬 练成 刘洪来 《Chinese Physics Letters》 SCIE CAS CSCD 2021年第11期77-82,共6页
Lithium-ion battery packs are made by many batteries, and the difficulty in heat transfer can cause many safety issues. It is important to evaluate thermal performance of a battery pack in designing process. Here, a m... Lithium-ion battery packs are made by many batteries, and the difficulty in heat transfer can cause many safety issues. It is important to evaluate thermal performance of a battery pack in designing process. Here, a multiscale method combining a pseudo-two-dimensional model of individual battery and three-dimensional computational fluid dynamics is employed to describe heat generation and transfer in a battery pack. The effect of battery arrangement on the thermal performance of battery packs is investigated. We discuss the air-cooling effect of the pack with four battery arrangements which include one square arrangement, one stagger arrangement and two trapezoid arrangements. In addition, the air-cooling strategy is studied by observing temperature distribution of the battery pack. It is found that the square arrangement is the structure with the best air-cooling effect, and the cooling effect is best when the cold air inlet is at the top of the battery pack. We hope that this work can provide theoretical guidance for thermal management of lithium-ion battery packs. 展开更多
关键词 Thermal Management of air-cooling Lithium-Ion Battery Pack
下载PDF
Experimental Investigation of the Cooling Capacity of Gaseous Carbon Dioxide in Free Jet Expansion for Use in Portable Air-Cooling Systems
3
作者 Chady Al Sayed Ludwig Vinches Stéphane Hallé 《Open Journal of Applied Sciences》 2018年第2期62-72,共11页
This paper investigates the possibility of using the free expansion of gaseous CO2 in portable air-cooling systems. The cooling capacity of the gaseous CO2 free jet expansion was calculated using three different appro... This paper investigates the possibility of using the free expansion of gaseous CO2 in portable air-cooling systems. The cooling capacity of the gaseous CO2 free jet expansion was calculated using three different approaches and the results showed that the simplified calculations would give approximated cooling values with an 11.6% maximum error. The mass flow rate, upstream pressure and cooling capacity of the gaseous CO2 decreased with time. A maximum 48.5 watts of cooling was recorded at minute 4 and a minimum value of 10.4 watts at the end of the test. The drop in cooling capacity is due to the evaporation of the liquid CO2 inside the small cylinder which cools the two-phase CO2 mixture and causes a pressure drop (from 6 MPa to 2.97 MPa), which also affects the mass flow rate of gaseous CO2 exiting the orifice (from 0.56 g/s to 0.24 g/s). If this cooling technique is to be considered in portable compact-cooling systems, the mass, pressure and cooling capacity drop with time must be solved. One of the solutions could be to cover the cylinder with a heating coat to compensate for the heat absorbed by the evaporation of the liquid CO2. 展开更多
关键词 Gaseous CO2 Free JET EXPANSION COOLING Capacity Compact air-cooling Technique
下载PDF
Analysis of Air-Cooling Battery Thermal Management System for Formula Student Car
4
作者 Leone Martellucci Kodekondla Kalyan Krishna 《Journal of Transportation Technologies》 2021年第3期436-454,共19页
Designing a good energy storage system represents the most important chall</span><span style="font-family:Verdana;">enge for spreading over a large scale of electric mobility. Proper thermal</... Designing a good energy storage system represents the most important chall</span><span style="font-family:Verdana;">enge for spreading over a large scale of electric mobility. Proper thermal</span> <span style="font-family:Verdana;">management is critical and guarantees optimum working temperature in a</span><span style="font-family:Verdana;"> battery pack. In the various battery thermal management technologies, air cooling is one of the most used solutions. The following work analyzes the cooling performance of the air-cooling thermal management system by choosing appropriate system parameters and analyzes using CFD simulations for accurate thermal modeling. These parameters include the influence of airflow rate </span><span style="font-family:Verdana;">and cell spacing on the configuration. The outcome of the simulations is</span><span style="font-family:Verdana;"> compared using parameters like maximum temperature, and temperature distribution in the battery module to obtain optimum results for further applications. Finally, the simulations of the optimal solution will be compared to experimental results for validation. 展开更多
关键词 BATTERY Thermal Management System air-cooling Formula Student
下载PDF
Precipitation of α_2 Phase in α+β Solution-Treated and Air-cooled Ti-Al-Sn-Zr-Mo-Si-Nd Alloys 被引量:4
5
作者 Jun ZHANG and Dong LI Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China resent address: Shenyang University, Shenyang 110044, China E-mail: zhjun14@mailcity.com 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2001年第3期315-317,共3页
A series of Ti-Al-Sn-Zr-Mo-Si-Nd alloys with various content of Al were solution treated in α+β phase field and air-cooled. The precipitation of a2 phase in cooling was investigated by transmission electron microsco... A series of Ti-Al-Sn-Zr-Mo-Si-Nd alloys with various content of Al were solution treated in α+β phase field and air-cooled. The precipitation of a2 phase in cooling was investigated by transmission electron microscopic analysis The precipitation characteristic of α2 phase was discussed. The precipitation of α2 phase would proceed by the nucleation and growth of α2 phase dependent on the diffusion of Al atoms. And a comparison on the difference of precipitation of α2 phase was carried out under the conditions of air-cooling and quenching in water. The investigation showed that the air-cooling and even quenching could supply enough time for the precipitation and growth of α2 phase when Al content reached a certain value even though far away from the stoichiometric composition of Ti3Al. 展开更多
关键词 Al Precipitation of Phase in Solution-Treated and air-cooled Ti-Al-Sn-Zr-Mo-Si-Nd Alloys Ti Mo Sn ZR ND Si
下载PDF
Effect of Chromium on CCT Diagrams of Novel Air-Cooled Bainite Steels Analyzed by Neural Network 被引量:4
6
作者 YOU Wei XU Wei-hong +2 位作者 LIU Ya-xiu BAI Bing-zhe FANG Hong-sheng 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2007年第4期39-42,共4页
The quantitative effects of chromium content on continuous cooling transformation (CCT) diagrams of novel air-cooled bainite steels were analyzed using artificial neural network models. The results showed that the c... The quantitative effects of chromium content on continuous cooling transformation (CCT) diagrams of novel air-cooled bainite steels were analyzed using artificial neural network models. The results showed that the chromium may retard the high and medium-temperature martensite transformation. 展开更多
关键词 novel air-cooled bainite steel CCT diagram artificial neural network chromium content quantitative effect
下载PDF
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:1
7
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 air-cooled Heat Pump Unit Compound Condensation Process (CCP) EXERGY Analysis Method Sanitary Hot Water MATLAB/SIMULINK Software Fluorine Substitute REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
Physical Properties of Crushed Air-cooled Blast Furnace Slag and Numerical Representation of Its Morphology Characteristics 被引量:1
8
作者 王爱国 邓敏 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第5期973-978,共6页
Physical properties and geometrical morphologies of crushed air-cooled blast furnace slag (SCR) and crushed limestone (LCR) were comparatively investigated. The shape, angularity, surface texture and internal pore... Physical properties and geometrical morphologies of crushed air-cooled blast furnace slag (SCR) and crushed limestone (LCR) were comparatively investigated. The shape, angularity, surface texture and internal pore structure of aggregate particles for different size and gradation were numerically represented by sphericity (ψ) and shape index (SI), angularity number (AN), index of aggregate particle shape and texture (IAPST), porosity and pore size, respectively. The results show that SCR is a porous and rough aggregate. Apparent density, void, water absorption and smashing index of SCR are obviously higher than those of LCR with the same gradation, respectively. However, bulk density of SCR is lower than that of LCR with the same gradation. SI, AN, IAPST and porosity of SCR are obviously higher than those of LCR with the same gradation, respectively. The smaller particle size of SCR, the larger of its AN, IAPST and porosity. 展开更多
关键词 crushed air-cooled blast furnace slag crushed limestone physical property morphology characteristic numerical representation
下载PDF
Application of Air-cooled Blast Furnace Slag Aggregates as Replacement of Natural Aggregates in Cement-based Materials:A Study on Water Absorption Property 被引量:1
9
作者 王爱国 liu peng +3 位作者 liu kaiwei li yan zhang gaozhan 孙道胜 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2018年第2期445-451,共7页
The influence of air-cooled blast furnace slag aggregates as replacement of natural aggregates on the water absorption of concrete and mortar was studied, and the mechanism was analyzed. The interface between aggregat... The influence of air-cooled blast furnace slag aggregates as replacement of natural aggregates on the water absorption of concrete and mortar was studied, and the mechanism was analyzed. The interface between aggregate and matrix in concrete was analyzed by using a micro-hardness tester, a laser confocal microscope and a scanning electron microscope with backscattered electron image mode. The pore structure of mortar matrixes under different curing conditions was investigated by mercury intrusion porosimetry. The results showed that when natural aggregates were replaced with air-cooled blast furnace slag aggregates in mortar or concrete, the content of the capillary pore in the mortar matrix was reduced and the interfacial structure between aggregate and matrix was improved, resulting in the lower water absorption of mortar or concrete. Compared to the concrete made with crushed limestone and natural river sand, the initial absorption coefficient, the secondary absorption coefficient and the water absorption capacity through the surface for 7 d of the concrete made from crushed air-cooled blast furnace slag and air-cooled blast furnace slag sand were reduced by 48.9%, 52.8%, and 46.5%, respectively. 展开更多
关键词 air-cooled blast furnace slag aggregate cement-based materials water absorption coefficient interface structure
下载PDF
Effect of Crushed Air-cooled Blast Furnace Slag on Mechanical Properties of Concrete
10
作者 王爱国 邓敏 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2012年第4期758-762,共5页
Morphology characteristics of mix aggregates with crushed air-cooled blast furnace slag(SCR) and crushed limestone(LCR) with 5-20 mm and 20-40 mm gradation were represented by numerical parameters including angula... Morphology characteristics of mix aggregates with crushed air-cooled blast furnace slag(SCR) and crushed limestone(LCR) with 5-20 mm and 20-40 mm gradation were represented by numerical parameters including angularity number(AN) and index of aggregate particle shape and texture(IAPST).The effect of mix aggregates containing SCR on compressive strength and splitting tensile strength of concrete was investigated.Fracture characteristics of concrete,interfacial structure between aggregates and matrix were analyzed.The experimental results show that porous and rough SCR increases contact area with matrix in concrete,concave holes and micro-pores on the surface of SCR are filled by mortar and hydrated cement paste,which may increase interlocking and mechanical bond between aggregate and matrix in concrete.SCR can be used to produce a high-strength concrete with better mechanical properties than corresponding concrete made with LCR.The increase of AN and IAPST of aggregate may enhance mechanical properties of concrete. 展开更多
关键词 crushed air-cooled blast furnace slag crushed limestone mechanical property morphology characteristic interfacial structure
下载PDF
Quantitative analysis of Ni effect on CCT diagrams of novel air-cooled bainite steels using artificial neural network models
11
作者 Weihong Xu Wei You +2 位作者 Yaxiu Liu Bingzhe Bai Hongsheng Fang 《Journal of University of Science and Technology Beijing》 CSCD 2005年第5期410-415,共6页
The quantitative effect of Ni content on continuous cooling transformation (CCT) diagrams of novel air-cooled bainite steels was analyzed using artificial neural network models. The results showed that Ni may retard... The quantitative effect of Ni content on continuous cooling transformation (CCT) diagrams of novel air-cooled bainite steels was analyzed using artificial neural network models. The results showed that Ni may retard the high- and medium-temperature transformation and martensite transformation. The results conform to the materials science theories. 展开更多
关键词 novel air-cooled bainite steels NICKEL CCT diagrams artificial neural network
下载PDF
The Experimental Investigation of Recirculation of Air-Cooled System for a Large Power Plant
12
作者 Wanli Zhao Qiyue Wang Peiqing Liu 《Energy and Power Engineering》 2010年第4期291-297,共7页
The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV... The paper introduces thermal buoyancy effects to experimental investigation of wind tunnel simulation on direct air-cooled condenser for a large power plant. In order to get thermal flow field of air-cooled tower, PIV experiments are carried out and recirculation ratio of each condition is calculated. Results show that the thermal flow field of the cooling tower has great influence on the recirculation under the cooling tower. Ameliorating the thermal flow field of the cooling tower can reduce the recirculation under the cooling tower and improve the efficiency of air-cooled condenser also. 展开更多
关键词 DIRECT air-cooled CONDENSER Thermal Flow Field Recirculation PIV EXPERIMENT Power PLANT
下载PDF
Field Observations of Near-Surface Wind Flow Across Expressway Embankment on the Qinghai–Tibet Plateau
13
作者 Yanhu Mu Wei Ma +3 位作者 Zhaohui(Joey)Yang Xiaolin Li Kun Zhang Yuncheng Mao 《Engineering》 SCIE EI CAS 2022年第7期169-180,共12页
Crushed rock layers(CRLs),ventilation ducts(VDs)and thermosyphons are air-cooling structures(ACSs)widely used for maintaining the long-term stability of engineered infrastructures in permafrost environments.These ACSs... Crushed rock layers(CRLs),ventilation ducts(VDs)and thermosyphons are air-cooling structures(ACSs)widely used for maintaining the long-term stability of engineered infrastructures in permafrost environments.These ACSs can effectively cool and maintain the permafrost subgrade’s frozen state under climate warming by facilitating heat exchange with ambient air in cold seasons.As convection is a crucial working mechanism of these ACSs,it is imperative to understand the near-surface wind flow(NSWF)across a constructed infrastructure,such as an embankment.This article describes a yearlong field observation of the NSWF across an experimental expressway embankment,the first of its kind on the Qinghai–Tibet Plateau(QTP).The wind speed and direction along a transect perpendicular to the embankment on both the windward and leeward sides and at four different heights above the ground surface were collected and analyzed.The results showed that the embankment has a considerable impact on the NSWF speed within a distance of up to ten times its height,and in the direction on the leeward side.A power law can well describe the speed profiles of NSWF across the embankment,with the power-law indices(PLIs)varying from 0.14 to 0.40.On an annual basis,the fitted NSWF PLI far away from the embankment was 0.19,which differs substantially from the values widely used in previous thermal performance evaluations of ACSs on the QTP.Finally,the significance of the NSWF to the thermal performance of the ACSs,particularly the CRLs and VDs,in linear transportation infrastructure is discussed.It is concluded that underestimating the PLI and neglecting wind direction variations may lead to unconservative designs of the ACSs.The results reported in this study can provide valuable guidance for infrastructure engineering on the QTP and other similar permafrost regions. 展开更多
关键词 Near-surface wind flow Field observation air-cooling structures Linear transportation infrastructure Qinghai–Tibet Plateau
下载PDF
Analysis of Nuclear Power Development in Henan Province Based on Carrying Capacity of Water Resources
14
作者 Chengli Wang Zhansheng Xi Lei Li 《Meteorological and Environmental Research》 CAS 2013年第8期53-55,共3页
Firstly, current situation of water resources in Henan Province was analyzed, and then carrying capacity of water resources in Henan Province was assessed based on "degree of water stress" and "balance index of car... Firstly, current situation of water resources in Henan Province was analyzed, and then carrying capacity of water resources in Henan Province was assessed based on "degree of water stress" and "balance index of carrying capacity of regional water resources", finally the thinking on adopting air-cooling technology to develop nuclear power in Henan Province was expounded. 展开更多
关键词 Water resources Carrying capacity Inland nuclear power air-cooling technology China
下载PDF
Heat Transfer Characteristics of Square Micro Pin Fins under Natural Convection
15
作者 Naoko Matsumoto Toshio Tomimura Yasushi Koito 《Journal of Electronics Cooling and Thermal Control》 2014年第3期59-69,共11页
In order to comply with the recent demand for downsizing of the electric equipment, the minia- turization and the improvement in heat transfer performance of a heat sink under natural air-cooling are increasingly requ... In order to comply with the recent demand for downsizing of the electric equipment, the minia- turization and the improvement in heat transfer performance of a heat sink under natural air-cooling are increasingly required. This paper describes the experimental and numerical investigations of heat sinks with miniature/micro pins and the effect of the pin size, pin height and the number of pins on heat transfer characteristics of heat sinks. Five types of basic heat sink models are investigated in this study. The whole heat transfer area of heat sinks having the different pin size, pin height and the number of pins respectively is kept constant. From a series of experiments and numerical analyses, it has been clarified that the heat sink temperature rises with increase in the number of pins. That is, the heat sink with miniaturized fine pins showed almost no effect on the heat transfer enhancement. This is because of the choking phenomenon occurred in the air space among the pin fins. Reflecting these results, it is confirmed that the heat transfer coefficient reduces with miniaturization of pins. Concerning the effects of the heat transfer area on the heat sink performance, almost the same tendency has been observed in other three series of large surface area, that is, higher pin height. Furthermore as a result of studying non-dimensional convection heat transfer performance, it was found that the relation between the Nusselt number (Nu) and the Rayleight number (Ra) is given by Nu = 0.16 Ra0.52. 展开更多
关键词 Natural air-cooling HEAT SINK Micro Pin FIN HEAT Transfer Performance Experiment NUMERICAL Analysis
下载PDF
Application of Microperforated-Panel Absorber in Communication Products 被引量:1
16
作者 Wenfang Yu Xianming Zhang Qingshan Dong 《Journal of Applied Mathematics and Physics》 2018年第1期51-57,共7页
Base on Prof. Maa Dah-You’s general theory of the microperforated-panel (MPP) absorber, We designed a noise reduction structure-sound attenuating cabinet (SAC). It can be applied to air-cooled communication products ... Base on Prof. Maa Dah-You’s general theory of the microperforated-panel (MPP) absorber, We designed a noise reduction structure-sound attenuating cabinet (SAC). It can be applied to air-cooled communication products to reduce system noise. This article introduces engineering design method of SAC and laboratory test noise reduction results of application of SAC. 展开更多
关键词 Microperforated-Panel (MPP) Sound Attenuating CABINET (SAC) air-cooled COMMUNICATION PRODUCTS
下载PDF
麦芽厂表冷器的热力计算
17
作者 陈昌斌 《包装与食品机械》 CAS 2006年第3期34-35,38,共3页
汉口电力设备厂生产的表面式冷却器(以下简称“表冷器”)用于啤酒厂的劳斯曼麦芽生产线,用以调节麦芽车间的空气温度。由于温度较低,其生产工艺参数不能按干空气计算。本文即是以实例说明如何利用湿空气的基础理论,结合特定的换热元件,... 汉口电力设备厂生产的表面式冷却器(以下简称“表冷器”)用于啤酒厂的劳斯曼麦芽生产线,用以调节麦芽车间的空气温度。由于温度较低,其生产工艺参数不能按干空气计算。本文即是以实例说明如何利用湿空气的基础理论,结合特定的换热元件,对表冷器的使用工况进行热力计算。 展开更多
关键词 麦芽厂 表冷器 热力计算 湿空气
下载PDF
Thermo-Flow Performances for the Main-Auxiliary Integrated Natural Draft Dry Cooling System
18
作者 ZHANG Zongyang HOU Yichen +6 位作者 ZHOU Hanyu JIA He CHEN Lei KONG Yanqiang WANG Weijia YANG Lijun DU Xiaoze 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第3期1010-1025,共16页
Recently,natural draft dry cooling system with the main-auxiliary integrated air-cooled heat exchangers in the up and lower layers,has drawn attention to the electric power industry.This research firstly develops two ... Recently,natural draft dry cooling system with the main-auxiliary integrated air-cooled heat exchangers in the up and lower layers,has drawn attention to the electric power industry.This research firstly develops two physical models for the integrated cooling system,namely Case A and Case B.In Case A,the main air-cooled heat exchanger is arranged in the upper layer and the auxiliary air-cooled heat exchanger arranged in the lower layer,while in Case B,the two heat exchanger systems are arranged in the opposite way.And then,directing at the engineering TMCR and TRL 1 working conditions,the unit-local-overall thermo-flow characteristics of Case A and Case B are obtained and compared by numerical simulation.The findings show that,for the auxiliary air-cooled exchanger,Case A has obviously higher cooling performances than Case B,with the difference varying from 5.46%to 7.55%.Whereas,for the main air-cooled exchanger,Case B shows the recovered cooling performances,with the difference changing from 1.15%to 2.99%.Case A is preferably recommended to the engineering application in consideration of more strict cooling demand of the auxiliary cooling system.Conclusively,this research will provide some theoretical guidelines for the design and construction of the main-auxiliary integrated natural draft dry cooling system. 展开更多
关键词 integrated dry cooling system main air-cooled heat exchanger auxiliary air-cooled heat exchanger upper layer and lower layer thermo-flow performances
原文传递
Measures against the adverse impact of natural wind on air-cooled condensers in power plant 被引量:22
19
作者 YANG LiJun,DU XiaoZe & YANG YongPing Key Laboratory of Condition Monitoring and Control for Power Plant Equipment of Ministry of Education of China,North China Electric Power University,Beijing 102206,China 《Science China(Technological Sciences)》 SCIE EI CAS 2010年第5期1320-1327,共8页
The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of a... The natural wind plays disadvantageous roles in the operation of air-cooled steam condensers in power plant.It is of use to take various measures against the adverse effect of wind for the performance improvement of air-cooled condensers.Based on representative 2×600 MW direct air-cooled power plant,three ways that can arrange and optimize the flow field of cooling air thus enhance the heat transfer of air-cooled condensers were proposed.The physical and mathematical models of air-cooled condensers with various flow leading measures were presented and the flow and temperature fields of cooling air were obtained by CFD simulation.The back pressures of turbine were calculated for different measures on the basis of the heat transfer model of air-cooled condensers.The results show that the performance of air-cooled condensers is improved thus the back pressure of turbine is lowered to some extent by taking measures against the adverse impact of natural wind. 展开更多
关键词 air-cooled CONDENSER WIND SPEED and direction flow and heat TRANSFER BACK pressure power PLANT
原文传递
Mn-Series Low-Carbon Air-Cooled Bainitic Steel Containing Niobium of 0.02% 被引量:4
20
作者 FENG Chun FANG Hong-sheng ZHENG Yan-kang BAI Bing-zhe 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2010年第4期53-58,共6页
A new hot rolled low-carbon air-cooled bainitic steel containing Nb of 0.02% has been developed based on alloying design of the grain boundary allotriomorphic ferrite (FGBA)/granular bainite (BG) duplex steel. The... A new hot rolled low-carbon air-cooled bainitic steel containing Nb of 0.02% has been developed based on alloying design of the grain boundary allotriomorphic ferrite (FGBA)/granular bainite (BG) duplex steel. The as-rolled microstructure and mechanical properties of bainitie steel containing Nb of 0. 02% were investigated by tensile test, optical microscopy (OM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The results show that adding 0.02 % of Nb obviously improves the strength without sacrificing toughness of the FGBA/BG steel. Adding 0.02% of Nb not only refines the grain boundary allotriomorphic ferrite grains but also promotes the refinement of granular bainite including its bainitic ferrite and M/A island. Any Nb(C,N) has been hardly observed in the steel containing Nb of 0.02%. It is suggested that the strengthening mechanism of Nb of 0.02% can be mainly attributed to the effect of Nb in solution (solute drag-like effect) on the phase transformation rather than the precipitation strengthening of Nb(C, N) particles. 展开更多
关键词 low-carbon air-cooled bainitic steel NIOBIUM MICROSTRUCTURE mechanical property
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部