Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is...Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price.展开更多
A novel dual source vapor injection heat pump(DSVIHP)using exhaust and ambient air is proposed.The air exhausted from the building first releases energy to the medium-pressure evaporator and is then mixed with the amb...A novel dual source vapor injection heat pump(DSVIHP)using exhaust and ambient air is proposed.The air exhausted from the building first releases energy to the medium-pressure evaporator and is then mixed with the ambient air to heat the low-pressure evaporator.A vapor injection(VI)compressor of two inlets is connected with the low and medium pressure evaporators.It’s first time that a VI compressor is employed to recover the ventilation heat.The system can minimize the ventilation heat loss and provide a unique defrosting approach by using the exhaust waste heat.Fundamentals of the proposed DSVIHP are illustrated.Mathematical models are built.Both energetic and exergetic analyses are carried out under variable conditions.The results indicate that the DSVIHP has superior thermodynamic performance.The superiority is more appreciable at a lower ambient temperature.It has a higher COP than the conventional vapor injection heat pump and air source heat pump by 11.3%and 23.2%respectively at an ambient temperature of-10°C and condensation temperature of 45°C.The waste heat recovery ratio from the exhaust air is more than 100%.The novel DSVIHP has great potential in the cold climate area application.展开更多
For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-comp...For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-component from the intermediate-component and it can be employed to initiate the development of vapor recompression heat pump(VRHP) assisted DWDC(VRHP-DWDC). Despite dividing wall may locate in the top, middle, and bottom, the optimum VRHP-DWDC is found to involve uniformlytwo VRHP circles. While the first one serves to compress and transform the excessive heat resulted from the separation of the heavy-component from the intermediate-component, the second one to compress and transform the overhead vapor stream of the light-component pre-heated sequentially with the condensate from the first one and the bottom product stream of the heavy-component, both releasing the temperature-elevated latent heat to the pre-fractionator's or common stripping section. The processing of two HCDWBT mixtures of benzene/toluene/o-xylene and n-pentane/n-hexane/n-heptane are selected to assess the derived optimum topological configurations of the VRHP-DWDC and their optimality is confirmed through detailed comparisons with the DWDC and two VRHP-DWDCs involving only one VRHP circle. The proposed strategy helps to tap the full potential of the VRHP-DWDC with considerably alleviated complication in process development.展开更多
基金supported by the Carbon Peak and Carbon Neutralization Science and Technology Innovation Special Fund of Jiangsu Province,China(No.BE2022859)Natural Science Foundation of Guangdong Province,China(No.2021A1515011763).
文摘Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price.
基金This work is funded by the UK BEIS project‘A low carbon heating system for existing public buildings employing a highly innovative multiple-throughout-flowing micro-channel solar-panel-array and a novel mixed indoor/outdoor air source heat pump’(LCHTIF1010).
文摘A novel dual source vapor injection heat pump(DSVIHP)using exhaust and ambient air is proposed.The air exhausted from the building first releases energy to the medium-pressure evaporator and is then mixed with the ambient air to heat the low-pressure evaporator.A vapor injection(VI)compressor of two inlets is connected with the low and medium pressure evaporators.It’s first time that a VI compressor is employed to recover the ventilation heat.The system can minimize the ventilation heat loss and provide a unique defrosting approach by using the exhaust waste heat.Fundamentals of the proposed DSVIHP are illustrated.Mathematical models are built.Both energetic and exergetic analyses are carried out under variable conditions.The results indicate that the DSVIHP has superior thermodynamic performance.The superiority is more appreciable at a lower ambient temperature.It has a higher COP than the conventional vapor injection heat pump and air source heat pump by 11.3%and 23.2%respectively at an ambient temperature of-10°C and condensation temperature of 45°C.The waste heat recovery ratio from the exhaust air is more than 100%.The novel DSVIHP has great potential in the cold climate area application.
基金The financial support from National Natural Science Foundation of China (21878011)。
文摘For dividing-wall distillation columns(DWDCs) separating a heavy-component dominated and wide boiling-point ternary(HCDWBT) mixture, a significant amount of excessive heat exists inevitably in stripping the heavy-component from the intermediate-component and it can be employed to initiate the development of vapor recompression heat pump(VRHP) assisted DWDC(VRHP-DWDC). Despite dividing wall may locate in the top, middle, and bottom, the optimum VRHP-DWDC is found to involve uniformlytwo VRHP circles. While the first one serves to compress and transform the excessive heat resulted from the separation of the heavy-component from the intermediate-component, the second one to compress and transform the overhead vapor stream of the light-component pre-heated sequentially with the condensate from the first one and the bottom product stream of the heavy-component, both releasing the temperature-elevated latent heat to the pre-fractionator's or common stripping section. The processing of two HCDWBT mixtures of benzene/toluene/o-xylene and n-pentane/n-hexane/n-heptane are selected to assess the derived optimum topological configurations of the VRHP-DWDC and their optimality is confirmed through detailed comparisons with the DWDC and two VRHP-DWDCs involving only one VRHP circle. The proposed strategy helps to tap the full potential of the VRHP-DWDC with considerably alleviated complication in process development.