ALANINE/ESR DOSIMETRY FOR MEASUREMENT OF ELECTRON DOSES IN INDUSTRIAL APPLICATIONS
1
作者 陈丽姝 李桂红 《Nuclear Science and Techniques》 SCIE CAS CSCD 1992年第4期225-232,共8页
In this report, the results of preliminary research on L-alanine/ESR electron dosimeters are described. They include the designs of modelling tools and experimental capsules, the preparation and irradiation of very th... In this report, the results of preliminary research on L-alanine/ESR electron dosimeters are described. They include the designs of modelling tools and experimental capsules, the preparation and irradiation of very thin dosimeters, the measurement of ESR signal spectrum and the calibration method. The physical, chemical and dosimetric properties of the alanine free radical dosimeters, such as the smallest thickness, average density, lowest detectable limit, repeatability of the method, reproducibility resulted in directivity and location in resonance cavity, linearity regions as well as relative scattering of the response to identical doses, are summarized. 展开更多
关键词 alanine/esr dosimeter electron dose
下载PDF
Dose inter-comparison studies for ^(60)Co gamma-ray and electron beam irradiation in the year 2002 被引量:3
2
作者 LINMin TakujiKOJIMA +6 位作者 ZofiaPEIMEL-STUGLIK CHENYun-Dong CUIYing CHENKe-Sheng LIHua-Zhi XIAOZhen-Hong SlawomirFABISIAK 《Nuclear Science and Techniques》 SCIE CAS CSCD 2004年第3期166-173,共8页
Dose inter-comparison studies for Co γ-ray and 10 MeV electron beam irradiation were carried out 60 from July to October in 2002. The purpose of the studies was to check the reliability of the alanine-PE film dosime-... Dose inter-comparison studies for Co γ-ray and 10 MeV electron beam irradiation were carried out 60 from July to October in 2002. The purpose of the studies was to check the reliability of the alanine-PE film dosime- ters made by CIAE, which will be used as transfer standard dosimetry system mainly for electron beam irradiation. The expanded uncertainty of CIAE alanine/EPR dosimetry system was 4.1% for doses not higher than 10 kGy and 5.4% for those above 10 kGy (k=2). CIAE alanine-PE film dosimeters were sent to JAERI, RISO (National Labora- tory in Denmark) and INCT respectively, which were irradiated by Co gamma-rays or electron beams in each labo- 60 ratory. The irradiated dosimeters were then sent back to CIAE for electron paramagnetic resonance (EPR) analysis. The agreements were obtained to be ±1.9% for gamma-ray dose measurement and ±4.3% for electron beam dose measurement, which were all within the combined uncertainty of the reference and CIAE alanine/EPR dosimetry system. Furthermore, the overall mean ratio was found to be 0.995 with 1.8% in the coefficient of variation (CV). The preliminary inter-comparison studies indicated that CIAE film alanine/EPR dosimetry system had the potential to be used as a transfer dosimetry system for high dose measurement. 展开更多
关键词 钴γ射线照射 不确定性 电子束照射 丙氨酸薄膜放射性剂量计
下载PDF
丙氨酸/ESR剂量计在断代中的应用 被引量:3
3
作者 高钧成 杜亚经 《核技术》 CAS CSCD 北大核心 1991年第2期90-93,共4页
本文介绍了丙氨酸/ESR剂量计的样品制备:剂量计刻度:用ESR谱仪测量辐照后丙氨酸样品中自由基数以确定吸收剂量的方法;剂量计的计量学性能及其在ESR断代、γ射线吸收剂量量值统一中的应用情况。
关键词 丙氨酸 esr剂量计 断代
下载PDF
丙氨酸-ESR剂量计剂量学基本特性的研究
4
作者 张荫芬 潘红斌 +1 位作者 谢立青 周瑞英 《北京师范大学学报(自然科学版)》 CAS CSCD 1990年第4期40-44,共5页
研究了丙氨酸-ESR 剂量计剂量学基本特性,以及剂量计元件的制备工艺.在0.1~10kGy 的剂量范围内有良好的线性响应,ESR 信号主峰幅值与相应剂量之间线性相关系数大于0.9999.为了提高测量精度,设计一种装置,使样品管位置下端固定,剂量计... 研究了丙氨酸-ESR 剂量计剂量学基本特性,以及剂量计元件的制备工艺.在0.1~10kGy 的剂量范围内有良好的线性响应,ESR 信号主峰幅值与相应剂量之间线性相关系数大于0.9999.为了提高测量精度,设计一种装置,使样品管位置下端固定,剂量计元件信号幅值的单次测量相对偏差从±1.1%改善到±0.45%.修正了 ESR 波谱仪增益系数之间的线性关系.对1kGy一组剂量计元件信号幅值分散性进行了检验,其相对标准偏差为±0.55%.剂量计元件辐照温度响应值的校正系数为0.20%±0.02%℃^(-1).吸收剂量在1.1kGy 点的总不确定度小于4.5%. 展开更多
关键词 丙氨酸 剂量计 射线 吸收剂量
下载PDF
丙氨酸-ESR剂量计用于测量产品箱内剂量分布的研究
5
作者 张荫芬 谢立青 +3 位作者 蓝李桥 马士铭 周瑞英 高钧成 《核农学报》 CAS CSCD 1992年第2期87-91,共5页
本文用自制丙氨酸-ESR剂量计和西德辐射与环境研究中心(GSF)的丙氨酸-ESR剂量计,测量了北京市射线应用中心的^(60)Coγ辐射源(1.44×10^(16)Bq)辐照纸箱包装(913mm×555mm×460mm)产品箱时的吸收剂量分布,箱内模拟产品(报纸... 本文用自制丙氨酸-ESR剂量计和西德辐射与环境研究中心(GSF)的丙氨酸-ESR剂量计,测量了北京市射线应用中心的^(60)Coγ辐射源(1.44×10^(16)Bq)辐照纸箱包装(913mm×555mm×460mm)产品箱时的吸收剂量分布,箱内模拟产品(报纸)的堆积密度为200ks/m^3,测量结果表明,产品箱內最大剂量D_(max)与最小剂量D_(min)之比分别为1.45(北京市辐射中心)和1.47(GSF),两者相差1.40%,在允许误差范围之内。 展开更多
关键词 丙氨酸剂量计 esr波谱 剂量分布
下载PDF
上海SSDL参加国际剂量比对总结(1983—1994) 被引量:2
6
作者 张利民 《现代计量测试》 1996年第5期40-44,共5页
文章总结了上海SSDL自1983年至1994年期间参加国际原子能机构组织的各种剂量比对活动的目的、方法和结果.十多年来的比对数据表明,上海SSDL在放射治疗水平、辐射加工水平和个人剂量防护水平及对X、γ射线吸收剂量测... 文章总结了上海SSDL自1983年至1994年期间参加国际原子能机构组织的各种剂量比对活动的目的、方法和结果.十多年来的比对数据表明,上海SSDL在放射治疗水平、辐射加工水平和个人剂量防护水平及对X、γ射线吸收剂量测量和控制等方面以满意的量值准确度与国际标准量值相统一。文章对测量误差进行了讨论. 展开更多
关键词 辐射计量 剂量比对 测量