期刊文献+
共找到31,072篇文章
< 1 2 250 >
每页显示 20 50 100
Is primary transcatheter aortic valve implantation the new normal?
1
作者 R.Anantharaman C.Sundar +1 位作者 Kamal Kant Jena K.Arun 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第4期458-461,共4页
Degenerative calcific aortic valve stenosis(AS)is the most common valvular heart disease in elderly.^[1] It is well documented that symptomatic severe AS follows a malignant course leading to cardiogenic shock(CS).
关键词 AORTIC STENOSIS implantation
下载PDF
Nursing Care and Causative Analysis of Grade IV Capsular Contracture Following Breast Cancer Expander Implantation
2
作者 Rong Chen Nan Zhang Huiting Zhang 《Advances in Breast Cancer Research》 CAS 2024年第1期1-9,共9页
Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reason... Objective: By observing the treatment and nursing care of a patient with Grade IV capsular contracture following breast cancer expander implantation and subsequent Stage II reconstruction, we aim to analyze the reasons for the formation of capsular contracture after Stage I expander implantation and prevent its recurrence following Stage II reconstruction. Methods: In May 2020, the patient noticed an increase in the size of a breast mass. In August, she underwent AC-THP neoadjuvant chemotherapy, followed by a “right breast-conserving nipple-areolar subglandular excision + right axillary lymph node dissection + expander implantation” surgery in November 2020. Radiation therapy began in January 2021. During radiation therapy, the patient experienced severe breast hardening, distortion, tenderness, and was diagnosed with Grade IV capsular contracture. To relieve the capsular contracture, the patient underwent a “contracted capsule incision and release procedure + removal of the right breast expander + right breast implantation” surgery in July 2021. Postoperatively, measures were taken to prevent incision infection, emphasizing aseptic techniques, ensuring smooth negative pressure drainage, reducing skin flap tension, monitoring skin flap blood supply, actively preventing subcutaneous effusion and hematoma, and applying appropriate compression dressings. Results: The patient was discharged after the removal of the drainage tube. During the postoperative follow-up at 3 and 6 months, there was no recurrence of capsular contracture, and the breast appeared full, upright, and relatively soft. There were no complications such as hematoma, infection, breast implant rupture, breast sagging, or displacement. The patient had a good outcome without additional financial or surgical burdens. Conclusion: The occurrence of Grade IV capsular contracture in the patient is generally related to infection after Stage I expander implantation, improper compression dressing, excessive saline injection causing content infiltration, and radiation therapy. Therefore, it is recommended to enhance the intraoperative and postoperative prophylactic use of antibiotics after Stage I expander implantation. Intermittent saline injection after surgery, with the amount of saline gradually increasing rather than filling all at once, is advisable. This helps the breast tissue gradually adapt to expansion, reducing the risk of capsular contracture. Postoperatively, patients should be instructed to wear pressure garments and breast elastic bandages while intensifying breast monitoring during radiation therapy and increasing postoperative follow-up. 展开更多
关键词 Breast Cancer Capsular Contracture Expander implantation
下载PDF
In‑depth proteome characterization of endometrium and extraembryonic membranes during implantation in pig
3
作者 Maria A.Gil Josep M.Cambra +3 位作者 Heriberto Rodriguez‑Martinez Cristina Cuello Inmaculada Parrilla Emilio A.Martinez 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2024年第3期1027-1055,共29页
Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallant... Background Proteome characterization of the porcine endometrium and extraembryonic membranes is important to understand mother-embryo cross-communication.In this study,the proteome of the endometrium and cho-rioallantoic membrane was characterized in pregnant sows(PS)during early gestation(d 18 and 24 of gestation)and in the endometrium of non-pregnant sows(NPS)during the same days using LC-MS/MS analysis.The UniProtKB database and ClueGO were used to obtain functional Gene Ontology annotations and biological and functional networks,respectively.Results Our analysis yielded 3,254 and 3,457 proteins identified in the endometrium of PS and NPS,respectively;of these,1,753 being common while 1,501 and 1,704 were exclusive to PS and NPS,respectively.In addition,we iden-tified 3,968 proteins in the extraembryonic membranes of PS.Further analyses of function revealed some proteins had relevance for the immune system process and biological adhesion in endometrium while the embryonic chorion displayed abundance of proteins related to cell adhesion and cytoskeletal organization,suggesting they dominated the moment of endometrial remodeling,implantation and adhesion of the lining epithelia.Data are available via Pro-teomeXchange with identifier PXD042565.Conclusion This is the first in-depth proteomic characterization of the endometrium and extraembryonic mem-branes during weeks 3 to 4 of gestation;data that contribute to the molecular understanding of the dynamic environ-ment during this critical period,associated with the majority of pregnancy losses. 展开更多
关键词 ENDOMETRIUM Extraembryonic membranes implantation PIG PROTEOME
下载PDF
Glaucoma drainage device implantation and cyclophotocoagulation in the management of refractory glaucoma after Descemet-stripping automated endothelial keratoplasty
4
作者 Min-Shu Wang Xue-Chuan Dong +4 位作者 Mi-Yun Zheng Xiang Fan Ge-Ge Xiao Jing Hong Ling-Ling Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期257-264,共8页
AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated en... AIM:To compare the surgical outcomes of glaucoma drainage device implantation(GDI)and trans-scleral neodymium:YAG cyclophotocoagulation(CPC)in the management of refractory glaucoma after Descemetstripping automated endothelial keratoplasty(DSAEK).METHODS:This retrospective study on observational case series enrolled 29 patients who underwent DSAEK and posterior anti-glaucoma surgery(15 with GDI and 14 with CPC).The main outcome measures were intraocular pressure(IOP),glaucoma surgery success rate(defined as IOP of 6–21 mm Hg without additional anti-glaucoma operation),number of glaucoma medications,endothelial graft status,and best-corrected visual acuity(BCVA).RESULTS:The mean follow-up time was 34.1 and 21.0mo for DSAEK or glaucoma surgeries,both for the GDI and CPC groups.Both groups showed significant IOP reduction after glaucoma surgery.The GDI group presented a significantly higher success rate in IOP control than the CPC group(60%vs 21.4%,P=0.03).Both procedures significantly decreased the number of glaucoma medications(P=0.03).Forty percent and 57%of cases in the GDI and the CPC group,respectively,experienced endothelial graft failure during follow-up(P=0.36).Significantly worse BCVA after surgery was observed in the CPC group but not in the GDI group.CONCLUSION:Both GDI and CPC significantly decrease IOP in eyes with glaucoma after DSAEK.GDI is preferable to CPC in refractory glaucoma cases after DSAEK,as it manifests a significantly higher success rate for IOP control,similar endothelial graft failure rate,and relatively preserves BCVA than CPC. 展开更多
关键词 glaucoma drainage device implantation CYCLOPHOTOCOAGULATION refractory glaucoma Descemetstripping automated endothelial keratoplasty
下载PDF
Embryo Transfer Strategies for Women with Recurrent Implantation Failure During the Frozen-thawed Embryo Transfer Cycles:Sequential Embryo Transfer or Double-blastocyst Transfer?
5
作者 Qiao-hang ZHAO Yu-wei SONG +8 位作者 Jian CHEN Xiang ZHOU Ji-lai XIE Qiu-ping YAO Qi-yin DONG Chun FENG Li-ming ZHOU Wei-ping FU Min JIN 《Current Medical Science》 SCIE CAS 2024年第1期212-222,共11页
Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of Se... Objective Both sequential embryo transfer(SeET)and double-blastocyst transfer(DBT)can serve as embryo transfer strategies for women with recurrent implantation failure(RIF).This study aims to compare the effects of SeET and DBT on pregnancy outcomes.Methods Totally,261 frozen-thawed embryo transfer cycles of 243 RIF women were included in this multicenter retrospective analysis.According to different embryo quality and transfer strategies,they were divided into four groups:group A,good-quality SeET(GQ-SeET,n=38 cycles);group B,poor-quality or mixed-quality SeET(PQ/MQ-SeET,n=31 cycles);group C,good-quality DBT(GQ-DBT,n=121 cycles);and group D,poor-quality or mixed-quality DBT(PQ/MQ-DBT,n=71 cycles).The main outcome,clinical pregnancy rate,was compared,and the generalized estimating equation(GEE)model was used to correct potential confounders that might impact pregnancy outcomes.Results GQ-DBT achieved a significantly higher clinical pregnancy rate(aOR 2.588,95%CI 1.267–5.284,P=0.009)and live birth rate(aOR 3.082,95%CI 1.482–6.412,P=0.003)than PQ/MQ-DBT.Similarly,the clinical pregnancy rate was significantly higher in GQ-SeET than in PQ/MQ-SeET(aOR 4.047,95%CI 1.218–13.450,P=0.023).The pregnancy outcomes of GQ-SeET were not significantly different from those of GQ-DBT,and the same results were found between PQ/MQ-SeET and PQ/MQ-DBT.Conclusion SeET relative to DBT did not seem to improve pregnancy outcomes for RIF patients if the embryo quality was comparable between the two groups.Better clinical pregnancy outcomes could be obtained by transferring good-quality embryos,no matter whether in SeET or DBT.Embryo quality plays a more important role in pregnancy outcomes for RIF patients. 展开更多
关键词 recurrent implantation failure sequential embryo transfer frozen-thawed embryo transfer embryo transfer strategies
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
6
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation Transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Effects of Continuous Precision Nursing Model on Knowledge, Attitudes, and Practices (KAP) Behavior and Cardiac Function in Patients after Percutaneous Coronary Angiography and Stent Implantation
7
作者 Cuiying Han 《Journal of Clinical and Nursing Research》 2024年第3期1-6,共6页
Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary a... Objective:To explore the impact of a continuous precision nursing model on patients’Knowledge,Attitudes,and Practices(KAP)and cardiac function during the nursing process of patients undergoing percutaneous coronary angiography and stent implantation.Methods:Ninety patients who underwent percutaneous coronary angiography and stent implantation in our hospital from April 2022 to April 2023 were selected and randomly divided into the control group(45 cases),in which routine nursing support was carried out during the treatment process,and the observation group(45 cases),in which continuous precision nursing model was carried out during the treatment process.Comparisons were made between the two groups of patients on their KAP,cardiac function,and quality of life during recovery.Results:There was no difference in the left ventricular ejection fraction(LVEF),cardiac output(CO),and cardiac index(CI)levels before intervention.After the intervention,the levels of cardiac function in the observation group were higher than those of the control group(P<0.05).There was no difference in the Exercise of Self-Care Agency(ESCA)self-care ability scale scores before the intervention.After the intervention,the observation group had higher ESCA scores than the control group(P<0.05).Conclusion:Implementation of a continuous precision nursing model in the care of patients undergoing percutaneous coronary angiography and stent implantation improved the patient’s cardiac function,and KAP,and promoted recovery. 展开更多
关键词 Continuous precision nursing model Percutaneous coronary angiography Stent implantation Knowledge attitudes and practices(KAP) Cardiac function
下载PDF
Postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens implantation versus small incision lenticule extraction in myopic eyes:a Meta-analysis 被引量:2
8
作者 Hong-Yu Li Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第3期442-452,共11页
AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,W... AIM:To compare the postoperative efficacy,safety,predictability,and visual quality of implantable collamer lens(ICL)implantation versus small incision lenticule extraction(SMILE)in myopia eyes.METHODS:Pub Med,EMBASE,Web of Science,Cochrane Library and several Chinese databases were searched at May 2021 to select relevant studies in comparison of clinical outcomes between ICL implantation and SMILE for myopia.The primary outcomes were efficacy,safety,and predictability.And the secondary outcomes were postoperative higher-order ocular aberrations(HOAs),modulation transfer function cutoff frequency(MTF),objective scatter index(OSI),contrast sensitivity and a quality of vision(Qo V)questionnaire.RESULTS:A total of 1036 eyes from 10 studies,of which 503 eyes underwent ICL implantation and 533 eyes underwent SMILE,were enrolled in this Meta-analysis.Pooled results revealed that ICL group had a better safety index and post-corrected distance visual acuity(CDVA)(P=0.007,<0.00001,respectively),and a lower percentage of eyes with a postoperative CDVA lost 1 line(P=0.007)than the SMILE group.No significant differences were found in comparison of the other primary outcomes.In the longterm follow-up(>6mo),ICL group had a lower total HOA,coma,and spherical aberration than SMILE group(P=0.003,<0.00001,0.04).Yet higher trefoil was found in ICL group at 6mo after surgery(P=0.003).Additionally,ICL group also had a higher MTF value(P=0.02),and a higher contrast sensitivity score for spatial frequencies of 1.5,6,and 12 cpds(P=0.02,0.005,0.02,respectively).And it also had a lower score of bothersome in Qo V questionnaire than SMILE group(P=0.003).CONCLUSION:ICL implantation and SMILE have similar and comparable outcomes in term of the efficacy and predictability for correcting high myopia.However,ICL group is relatively safer and also has better visual quality in comparison of SMILE group. 展开更多
关键词 implantable collamer lens small incision lenticule extraction MYOPIA refractive surgery META-ANALYSIS
下载PDF
Long-term observation on safety and visual quality of implantable collamer lens V4c implantation for myopia correction:a 5-year follow-up 被引量:2
9
作者 Xiao Chen Li Li +4 位作者 Jing Rao Yue-Xi Chen Yang Gao Rui-Xue Huang Qi-Zhi Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1123-1129,共7页
AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted... AIM:To elucidate the safety and visual quality of implantable collamer lens with central hole(ICL V4c)implantation for correcting moderate and high myopia for at least 5y.METHODS:This retrospective study was conducted on 58 patients(114 eyes)who were followed up for at least 5y after ICL V4c implantation.The observation was done before and on 1d,1mo,1 and 5y or more after the surgical procedure.The visual acuity,subjective refraction,intraocular pressure,vault,axial length,central hole position,pupil diameter,visual quality,and adverse events were analyzed.The visual quality includes aberration,the modulation transfer function cutoff frequency(MTF cutoff),objective scattering index(OSI),Stroller's ratio(SR),and visual quality questionnaire.RESULTS:The average follow-up period was 69.25±3.80mo(range 60–82mo)and the preoperative spherical equivalent(SE)was-8.66±1.97 D.At 5y after operation,the safety index was 1.01±0.02 and the efficacy index was 0.99±0.42 and SE was-0.65±0.63 D.The 59.6%of the eyes achieved an uncorrected distance visual acuity of 20/20,76.3%of the eyes had SE within±1.0 D at the last visit.The axial length increased by 0.29±0.71 mm 5y after the surgery(t=-3.843,P<0.001).The mean vault at the last follow-up was 510.59±245.61μm.The central hole was on the temporal side in 80 eyes(84.2%).The visual quality questionnaire showed that 98.2%patients were satisfied with the surgical procedure.Adverse events occurred in 4 eyes(3.5%),including the posttraumatic toric ICL rotation(2 eyes),iris incarceration(1 eye),and posttraumatic ICL displacement(1 eye)at the last follow-up.CONCLUSION:Long-term ICL V4c implantation is safe,effective,and stable for correcting moderate and to high myopia,and the visual quality with patients is excellent and satisfactory,but the progression of axial length still needs attention after surgery. 展开更多
关键词 implantable collamer lens with central hole myopia correction refractive surgery visual quality
下载PDF
The role of cochlear implantation in alleviating Tumarkin drop attacks of Meniere's disease;a case report 被引量:1
10
作者 Chiara Filippi Edoardo Covelli +2 位作者 Haitham H.Elfarargy Simonetta Monini Maurizio Barbara 《Journal of Otology》 CAS CSCD 2023年第3期168-172,共5页
Ménière’s disease(MD)patients may suffer episodes of sudden falls,named Tu markin drop attacks(DAs).This fall occurs abruptly and without warning or loss of consciousness.DAs usually aggravate the clinical ... Ménière’s disease(MD)patients may suffer episodes of sudden falls,named Tu markin drop attacks(DAs).This fall occurs abruptly and without warning or loss of consciousness.DAs usually aggravate the clinical picture of MD and are challenging to manage.The present report describes a case treated by cochlear implantation(CI)due to concomitant deafness and offers some clinical considerations for this condition.A male patient aged 48 years with a 10-year history of definite bilateral MD had profound SNHL on the right and severe SNHL on the left side.He suffered from intermittent attacks of vertigo,ear fullness,and tinnitus and,in the last year,had developed DAs and experienced 14 episodes in the previous six months.The preoperative category of acoustic performance was 3.The Dizziness Handicap Inventory(DHI)questionnaire showed a total score of 46,which indicated a moderate degree of disability.A CI was planned for the right side.The patient did not report any further DAs episode for two years since then.The postoperative category of acoustic performance became 11,and the postoperative DHI questionnaire showed a decrease in the total score(from 46 to 19),which indicated a mild disability.Unilateral CI effectively alleviated the DAs associated with bilateral MD.Our report proposes a new modality for managing vertiginous symptoms in cases of MD with hearing loss without the need for more aggressive surgical interventions with the need for clinical trials to confirm our results. 展开更多
关键词 Meniere's disease Tumarkin drop attacks Hearing loss Cochlear implant
下载PDF
A Custom Manipulator for Dental Implantation Through Model-Based Design 被引量:1
11
作者 Anitha Govindhan Karnam Anantha Sunitha Sivanathan Kandhasamy 《Intelligent Automation & Soft Computing》 SCIE 2023年第1期351-365,共15页
This paper presents a Model-Based Design(MBD)approach for the design and control of a customized manipulator intended for drilling and position-ing of dental implants accurately with minimal human intervention.While p... This paper presents a Model-Based Design(MBD)approach for the design and control of a customized manipulator intended for drilling and position-ing of dental implants accurately with minimal human intervention.While performing an intra-oral surgery for a prolonged duration within a limited oral cavity,the tremor of dentist's hand is inevitable.As a result,wielding the drilling tool and inserting the dental implants safely in accurate position and orientation is highly challenging even for experienced dentists.Therefore,we introduce a customized manipulator that is designed ergonomically by taking in to account the dental chair specifications and anthropomorphic data such that it can be readily mounted onto the existing dental chair.The manipulator can be used to drill holes for dental inserts and position them with improved accuracy and safety.Further-more,a thorough multi-body motion analysis of the manipulator was carried out by creating a virtual prototype of the manipulator and simulating its controlled movements in various scenarios.The overall design was prepared and validated in simulation using Solid works,MATLAB and Simulink through Model Based Design(MBD)approach.The motion simulation results indicate that the manipulator could be built as a prototype readily. 展开更多
关键词 Model based design multi-body motion simulation custom manipulator orthodontic implants mathematical approach
下载PDF
Role of dendritic cells in MYD88-mediated immune recognition and osteoinduction initiated by the implantation of biomaterials
12
作者 Zifan Zhao Qin Zhao +6 位作者 Hu Chen Fanfan Chen Feifei Wang Hua Tang Haibin Xia Yongsheng Zhou Yuchun Sun 《International Journal of Oral Science》 SCIE CAS CSCD 2023年第3期411-421,共11页
Bone substitute material implantation has become an important treatment strategy for the repair of oral and maxillofacial bone defects.Recent studies have shown that appropriate inflammatory and immune cells are essen... Bone substitute material implantation has become an important treatment strategy for the repair of oral and maxillofacial bone defects.Recent studies have shown that appropriate inflammatory and immune cells are essential factors in the process of osteoinduction of bone substitute materials.Previous studies have mainly focused on innate immune cells such as macrophages.In our previous work,we found that T lymphocytes,as adaptive immune cells,are also essential in the osteoinduction procedure.As the most important antigen-presenting cell,whether dendritic cells(DCs)can recognize non-antigen biomaterials and participate in osteoinduction was still unclear.In this study,we found that surgical trauma associated with materials implantation induces necrocytosis,and this causes the release of high mobility group protein-1(HMGB1),which is adsorbed on the surface of bone substitute materials.Subsequently,HMGB1-adsorbed materials were recognized by the TLR4-MYD88-NFκB signal axis of dendritic cells,and the inflammatory response was activated.Finally,activated DCs release regeneration-related chemokines,recruit mesenchymal stem cells,and initiate the osteoinduction process.This study sheds light on the immune-regeneration process after bone substitute materials implantation,points out a potential direction for the development of bone substitute materials,and provides guidance for the development of clinical surgical methods. 展开更多
关键词 implantation BIOMATERIALS RELEASE
下载PDF
Transcatheter aortic valve implantation in a patient with anomalous right coronary artery originating from the left aortic sinus with interarterial course
13
作者 Lu-Chen WANG Yan-Xiang LIU +1 位作者 Xiao-Gang SUN Wei WANG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第8期612-614,共3页
Recently,the utilization of transcatheter aortic valve implantation(TAVI)has gained increasing prevalence due to its expanding range of applications in managing symptomatic severe aortic stenosis(AS).Coronary obstruct... Recently,the utilization of transcatheter aortic valve implantation(TAVI)has gained increasing prevalence due to its expanding range of applications in managing symptomatic severe aortic stenosis(AS).Coronary obstruction,a life-threatening complication,has been reported to occur during and after TAVI at an incidence rate of 0.5%-1%.^([1])In addition to shallow sinus of Valsalva(less than 30 mm),low coronary take-off(below 12 mm from annulus plane),and calcification of native valve leaflets over the coronary ostium,anomalous origins of coronary arteries and compression from expanded transcatheter heart valve have been shown to cause TAVI-associated coronary occlusion. 展开更多
关键词 CORONARY AORTIC implantation
下载PDF
A simultaneous occurrence of pulmonary embolism and cerebral infarction following Micra^(TM)leadless pacemaker implantation
14
作者 Song-Hua LI Shao-Hua DONG +5 位作者 Tong KAN Sun YUE Bo LI Yang LU Pan LI Zhi-Fu GUO 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第10期756-759,共4页
Since the successful implantation of the first cardiac pacemaker(PM)in 1958,PM has been widely used in clinical practice.With the advancement of interventional technology,PMs have become smaller and more effective.Des... Since the successful implantation of the first cardiac pacemaker(PM)in 1958,PM has been widely used in clinical practice.With the advancement of interventional technology,PMs have become smaller and more effective.Despite continuous improvements,traditional PMs remain associated with a proportional risk of immediate-and short-term complications(9%–12%),[1]which are mainly related to electrodes or pockets.Short-term complications include pneumothorax,cardiac tamponade. 展开更多
关键词 CARDIAC implantation CEREBRAL
下载PDF
Exercise-based real-time telerehabilitation for older patients recently discharged after transcatheter aortic valve implantation: An extended feasibility study
15
作者 Barbara Cristina Brocki Jan Jesper Andreasen +2 位作者 Jens Aarøe Jane Andreasen Charlotte B Thorup 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2023年第11期767-778,共12页
OBJECTIVES To assess the extended feasibility of a telerehabilitation program and its effects on physical performance in older adults who have recently undergone transcatheter aortic valve implantation(TAVI).METHODS I... OBJECTIVES To assess the extended feasibility of a telerehabilitation program and its effects on physical performance in older adults who have recently undergone transcatheter aortic valve implantation(TAVI).METHODS In this single-center feasibility study, patients underwent an eight-week telerehabilitation program, involving webbased home exercise training twice weekly, an activity tracker, access to an informative website, and one online session with a nurse, starting one-week postoperative. Data collection was performed before surgery and three months postoperative. The feasibility of the intervention was based on recruitment and adherence to the program. As a secondary outcome, we evaluated the change in six-minute walk distance from before surgery to three months postoperative.RESULTS Forty-one patients scheduled for TAVI were assessed for eligibility;15 patients(37%) were enrolled. Of these, eight were excluded after surgery due to tiredness(n = 2), non-cardiac related hospital readmission(n = 2), fluctuating health(n = 1),death during hospital stay(n = 1), and reduced cognition(n = 2). Seven patients completed the eight-week web-based intervention and were evaluated three months postoperative. Their median(IQR) age was 83 [81, 87] years, and the sample comprised three men and four women. Their walked distance improved from median(IQR) 262 [199, 463] before surgery, to 381 [267, 521]meters three months postoperative. No adverse events were reported.CONCLUSION Web-based telerehabilitation, including supervised exercise training, in older adults who have recently undergone TAVI was feasible for a small number of patients who completed the eight-week intervention. This was reflected in an improvement in their walked distance three months after the surgery. However, the low recruitment and retention rates do question the overall feasibility of this intervention in a frail, older population of post-TAVI patients. 展开更多
关键词 patients NURSE implantation
下载PDF
Study of surface morphology in GaAs by hydrogen and helium implantation at elevated temperature
16
作者 Rui Huang Zhiyong Wang +2 位作者 Hui Li Qing Wang Yecai Guo 《Journal of Semiconductors》 EI CAS CSCD 2023年第5期27-33,共7页
In this work,the surface morphology and internal defect evolution process of GaAs substrates implanted with light ions of different fluence combinations are studied.The influence of H and He ions implantation on the a... In this work,the surface morphology and internal defect evolution process of GaAs substrates implanted with light ions of different fluence combinations are studied.The influence of H and He ions implantation on the atomic mechanism of the blister phenomenon observed after annealing is investigated.Raman spectroscopy is used to measure the surface stress change of different samples before and after implantation and annealing.Optical microscopy and atomic force microscopy are used to characterize the morphology changes of the GaAs surface under different annealing conditions.The evolution of bubbles and defects in GaAs crystals is revealed by transmission electron microscopy.Through this study,it is hoped that ion implantation fluence,surface exfoliation efficiency and exfoliation cost can be optimized.At the same time,it also lays a foundation for the heterointegration of GaAs film on Si. 展开更多
关键词 implantation surface ANNEALING
下载PDF
Cysteine dioxygenase and taurine are essential for embryo implantation by involving in E2-ERαand P_(4)-PR signaling in mouse
17
作者 Di Zhang Zhijuan Wang +5 位作者 Xuan Luo Hongzhou Guo Guobin Qiu Yuneng Gong Hongxu Gao Sheng Cui 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2023年第3期1040-1053,共14页
Background Taurine performs multiple physiological functions,and the maintenance of taurine level for most mammals relies on active uptake from diet and endogenous taurine synthesis through its synthesis enzymes,inclu... Background Taurine performs multiple physiological functions,and the maintenance of taurine level for most mammals relies on active uptake from diet and endogenous taurine synthesis through its synthesis enzymes,including cysteine dioxygenase(CDO).In addition,uterus tissue and uterus fluid are rich in to urine,and to urine synthesis is regulated by estrogen(E2)and progesterone(P_(4)),the key hormones priming embryo-uterine crosstalk during embryo implantation,but the functional interactions and mechanisms among which are largely unknown.The present study was thus proposed to identify the effects of CDO and taurine on embryo implantation and related mechanisms by using Cdo knockout(KO)and ovariectomy(OVX)mouse models.Results The uterine CDO expression was assayed from the first day of plugging(d 1)to d 8 and the results showed that CDO expression level increased from d 1 to d 4,followed by a significant decline on d 5 and persisted to d 8,which was highly correlated with serum and uterine taurine levels,and serum P_(4) concentration.Next,Cdo KO mouse was established by CRISPER/Cas9.It was showed that Cdo deletion sharply decreased the taurine levels both in serum and uterus tissue,causing implantation defects and severe subfertility.However,the implantation defects in Cdo KO mice were partly rescued by the taurine supplementation.In addition,Cdo deletion led to a sharp decrease in the expressions of P_(4)receptor(PR)and its responsive genes Ihh,Hoxa10 and Hand2.Although the expression of uterine estrogen receptor(ERa)had no significant change,the levels of ERa induced genes(Muc1,Ltf)during the implantation window were upregulated after Cdo deletion.These accompanied by the suppression of stroma cell proliferation.Meanwhile,E2inhibited CDO expression through ERa and P_(4)upregulated CDO expression through PR.Conclusion The present study firstly demonstrates that taurine and CDO play prominent roles in uterine receptivity and embryo implantation by involving in E2-ERa and P_(4)-PR signaling.These are crucial for our understanding the mechanism of embryo implantation,and infer that taurine is a potential agent for improving reproductive efficiency of livestock industry and reproductive medicine. 展开更多
关键词 CDO E2 Embryo implantation P_(4) TAURINE
下载PDF
Comparing accuracy of cochlear measurements on magnetic resonance imaging and computed tomography:A step towards radiation-free cochlear implantation
18
作者 Anurita Swarup Vinusree Karakkandy +12 位作者 Preetam Chappity Suprava Naik Sanjay Kumar Behera Pradipta Kumar Parida Mohnish Grover Gaurav Gupta Prajna Paramita Giri Saurav Sarkar Pradeep Pradhan Dillip Kumar Samal Aswathi Kallyadan Veetil Asutosh Adhikari Saurav Nayak 《Journal of Otology》 CAS CSCD 2023年第4期208-213,共6页
Objective:Computed Tomography(CT)and Magnetic Resonance Imaging(MRI)are commonly employed in pre-operative evaluation for cochlear implant surgery.However,with a decrease in the age of implantation,even minor radiatio... Objective:Computed Tomography(CT)and Magnetic Resonance Imaging(MRI)are commonly employed in pre-operative evaluation for cochlear implant surgery.However,with a decrease in the age of implantation,even minor radiation exposure can cause detrimental effects on children over their lifetime.The current study compares different cochlear measurements from CT and MRI scans and evaluates the feasibility of using only an MRI scan for radiological evaluation before cochlear implantation.Methods:A longitudinal observational study was conducted on 94 ears/47 children,employing CT and MRI scans.The CT and MRI scan measurements include,A value,B value,Cochlear duct length(CDL),twoturn cochlear length,alpha and beta angles to look for cochlear orientation.Cochlear nerve diameter was measured using MRI.The values were compared.Results:The mean difference between measurements from CT and MRI scans for A value,B value,CDL,and two-turn cochlear length values was 0.567±0.413 mm,0.406±0.368 mm,2.365±1.675 mm,and 2.063±1.477 mm respectively without any significant difference.The alpha and beta angle measures were comparable,with no statistically significant difference.Conclusion:The study suggests that MRI scans can be the only radiological investigation needed with no radiation risk and reduces the cost of cochlear implant program in the paediatric population.There is no significant difference between the measurements obtained from CT and MRI scans.However,observed discrepancies in cochlear measurements across different populations require regionally or race-specific standardized values to ensure accurate diagnosis and precision in cochlear implant surgery.This aspect must be addressed to ensure positive outcomes for patients. 展开更多
关键词 Cochlear implant Hearing loss Cochlea anatomy RADIOLOGY
下载PDF
Stages of Emotional Experience of Parents of Children with Cochlear Implantation (CI)
19
作者 Iuliia Khomiakova 《Open Journal of Medical Psychology》 2023年第4期231-238,共8页
Rehabilitation is a set of measures aimed at compensating or fully restoring the functions of the patient impaired by the disease. In the rehabilitation of children with a cochlear implant, a comprehensive, systematic... Rehabilitation is a set of measures aimed at compensating or fully restoring the functions of the patient impaired by the disease. In the rehabilitation of children with a cochlear implant, a comprehensive, systematic approach is essential in the work of doctors, teachers, sign language teachers, psychologists, and families. Rehabilitation and social adaptation of children with a cochlear implant depend not only on specialists but also on the ability of parents to help the child organize educational activities in an optimistic mood and the ability to provide emotional support. This means that the role of parents in the way to successful rehabilitation is high, and therefore this topic is especially relevant today. . 展开更多
关键词 Emotions during the Rehabilitation Children with a Cochlear implantation Rehabilitation Process Parents of Children with Cochlear implantation (CI)
下载PDF
Impact of central venous port implantation method and access choice on outcomes
20
作者 Ayhan Erdemir Huseyin Kemal Rasa 《World Journal of Clinical Cases》 SCIE 2023年第1期116-126,共11页
BACKGROUND Although the number of patients who need central venous ports for permanent vascular access is increasing,there is still no“gold standard”for the implantation technique.AIM To identify the implantation te... BACKGROUND Although the number of patients who need central venous ports for permanent vascular access is increasing,there is still no“gold standard”for the implantation technique.AIM To identify the implantation technique that should be favored.METHODS Two hundred central venous port-implanted patients in a tertiary hospital were retrospectively evaluated.Patients were assigned into two groups according to the access method.The first group comprised patients whose jugular veins were used,and the second group comprised patients whose subclavian veins were used.Groups were evaluated regarding age,sex,application side,primary diagnosis,active follow-up period in the hospital,chemotherapy agents administered,number of complications,and the Clavien-Dindo severity score.The distribution of the variables was tested with the Kolmogorov-Smirnov test and the Mann-Whitney U test.Theχ^(2) test was used to analyze the variables.RESULTS There was no statistically significant difference between the groups regarding age,sex,side,number of chemotherapy drugs,and duration of port usage(P>0.05).Only 2 patients in group 1 had complications,whereas in group 2 we observed 19 patients with complications(P<0.05).No port occlusion was found in group 1,but the catheters of 4 patients were occluded in group 2.One port was infected in group 1 compared to three infected ports in group 2.Two port ruptures,two pneumothorax,one revision due to a mechanical problem,one tachyarrhythmia during implantation,and four suture line problems were also recorded in group 2 patients.We also showed that it would be sufficient to evaluate and wash ports once every 2 mo.CONCLUSION Our results robustly confirm that the jugular vein route is safer than the subclavian vein approach for central venous port implantation. 展开更多
关键词 Permanent vascular access Central venous ports Central venous port implantation methods Jugular vein route Subclavian vein approach Impact of implantation method on outcomes
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部