In this paper, a new class of skew multimodal distributions with more flexible than alpha skew normal distribution and alpha-beta skew normal distribution is proposed, which makes some important distributions become i...In this paper, a new class of skew multimodal distributions with more flexible than alpha skew normal distribution and alpha-beta skew normal distribution is proposed, which makes some important distributions become its special cases. The statistical properties of the new distribution are studied in detail, its moment generating function, skewness coefficient, kurtosis coefficient, Fisher information matrix, maximum likelihood estimators are derived. Moreover, a random simulation study is carried out for test the performance of the estimators, the simulation results show that with the increase of sample size, the mean value of maximum likelihood estimators tends to the true value. The new distribution family provides a better fit compared with other known skew distributions through the analysis of a real data set.展开更多
Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because...Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water. The method consists of using pulse decay discrimination (PDD) liquid scintillation counting LSC of 2 ml of the sample after conditioning with 12 ml of AB-Ultima Gold LSC cocktail, and PDD 139 condition. Different factors that affected on the counting efficiency were studied such as quench reaction, volume of sample, and type of vial. The gross alpha and gross beta particle activity measurement using 40K and 243Am with different activities concentration for efficiency determination. The calculated detection limits were 0.07 Bq/l and 0.12 Bq/l for gross alpha and gross beta respectively for 500 min measurements of samples produced by concentration of one liter of water.展开更多
BACKGROUND Remarkable progress over the last decade has equipped clinicians with many options in the treatment of inflammatory bowel disease.Clinicians now have the unique opportunity to provide individualized treatme...BACKGROUND Remarkable progress over the last decade has equipped clinicians with many options in the treatment of inflammatory bowel disease.Clinicians now have the unique opportunity to provide individualized treatment that can achieve and sustain remission in many patients.However,issues of primary non-response(PNR)and secondary loss of response(SLOR)to non-tumour necrosis factor inhibitor(TNFi)therapies remains a common problem.Specific issues include the choice of optimization of therapy,identifying when dose optimization will recapture response,establishing optimal dose for escalation and when to switch therapy.AIM To explores the issues of PNR and SLOR to non-TNFi therapies.METHODS This review explores the current evidence and literature to elucidate management options in cases of PNR/SLOR.It will also explore potential predictors for response following SLOR/PNR to therapies including the role of therapeutic drug monitoring(TDM).RESULTS In the setting of PNR and loss of response to alpha-beta7-integrin inhibitors and interleukin(IL)-12 and IL-23 inhibitors dose optimization is a reasonable option to capture response.For Janus kinase inhibitors dose optimization can be utilized to recapture response with loss of response.CONCLUSION The role of TDM in the setting of advanced non-TNFi therapies to identify patients who require dose optimization and as a predictor for clinical remission is not yet established and this remains an area that should be addressed in the future.展开更多
Drinking good quality water is essential for better health. It is therefore essential to assess the radiological quality of all water consumed in the District of Abidjan in order to prevent related hazards. Thus, the ...Drinking good quality water is essential for better health. It is therefore essential to assess the radiological quality of all water consumed in the District of Abidjan in order to prevent related hazards. Thus, the objective of this study was to assess the risk of cancer due to the ingestion of alpha and beta emitting radionuclides in the different types of water consumed in the region. A total of 63 water samples with 43 tap water samples, 5 bottled mineral water and 15 sachet water samples was collected and taken to GAEC laboratory for analysis. The low background Gas-less Automatic Alpha/Beta counting system (Canberra iMatic<sup>TM</sup>) was used to determine alpha and beta activity concentrations. Activity concentrations of both gross alpha and gross beta obtained in water sample were respectively lower than the WHO recommended limits of 0.1 Bq/l and 1 Bq/l. Also, the annual effective dose and total equivalent effective dose found in mineral bottled water samples were higher than in other types of water. The assessment of radiological lifetime risk has shown values of cancer risk due to ingestion alpha and beta emitters lower than recommended limit. These results indicate that there is no health hazard associated to consumption of water in the District of Abidjan.展开更多
文摘In this paper, a new class of skew multimodal distributions with more flexible than alpha skew normal distribution and alpha-beta skew normal distribution is proposed, which makes some important distributions become its special cases. The statistical properties of the new distribution are studied in detail, its moment generating function, skewness coefficient, kurtosis coefficient, Fisher information matrix, maximum likelihood estimators are derived. Moreover, a random simulation study is carried out for test the performance of the estimators, the simulation results show that with the increase of sample size, the mean value of maximum likelihood estimators tends to the true value. The new distribution family provides a better fit compared with other known skew distributions through the analysis of a real data set.
文摘Liquid scintillation counting (LSC) is an adequate nuclear technique to determine radioactivity levels, as verified by this study for the determination of the gross alpha and beta activities of aqueous samples because of its simplicity and low associated cost comparison with other techniques. This paper discusses a new approach to the monitoring of gross alpha and gross beta activities in water. The method consists of using pulse decay discrimination (PDD) liquid scintillation counting LSC of 2 ml of the sample after conditioning with 12 ml of AB-Ultima Gold LSC cocktail, and PDD 139 condition. Different factors that affected on the counting efficiency were studied such as quench reaction, volume of sample, and type of vial. The gross alpha and gross beta particle activity measurement using 40K and 243Am with different activities concentration for efficiency determination. The calculated detection limits were 0.07 Bq/l and 0.12 Bq/l for gross alpha and gross beta respectively for 500 min measurements of samples produced by concentration of one liter of water.
文摘BACKGROUND Remarkable progress over the last decade has equipped clinicians with many options in the treatment of inflammatory bowel disease.Clinicians now have the unique opportunity to provide individualized treatment that can achieve and sustain remission in many patients.However,issues of primary non-response(PNR)and secondary loss of response(SLOR)to non-tumour necrosis factor inhibitor(TNFi)therapies remains a common problem.Specific issues include the choice of optimization of therapy,identifying when dose optimization will recapture response,establishing optimal dose for escalation and when to switch therapy.AIM To explores the issues of PNR and SLOR to non-TNFi therapies.METHODS This review explores the current evidence and literature to elucidate management options in cases of PNR/SLOR.It will also explore potential predictors for response following SLOR/PNR to therapies including the role of therapeutic drug monitoring(TDM).RESULTS In the setting of PNR and loss of response to alpha-beta7-integrin inhibitors and interleukin(IL)-12 and IL-23 inhibitors dose optimization is a reasonable option to capture response.For Janus kinase inhibitors dose optimization can be utilized to recapture response with loss of response.CONCLUSION The role of TDM in the setting of advanced non-TNFi therapies to identify patients who require dose optimization and as a predictor for clinical remission is not yet established and this remains an area that should be addressed in the future.
基金supported by the National Natural Science Foundation of China (21574038 and 21774031)the National Natural Science Foundation of China for Innovative Research Groups (51621002)+6 种基金the National Key Research and Development Program of China (2016YFC1100401)the Natural Science Foundation of Shanghai (18ZR1410300)the "Eastern Scholar Professorship" from Shanghai local government (TP2014034)the national special fund for State Key Laboratory of Bioreactor Engineering (2060204)the 1000 Talent Young Scholar program in China111 project (B14018)the program for professor of special appointment at ECUST
文摘Drinking good quality water is essential for better health. It is therefore essential to assess the radiological quality of all water consumed in the District of Abidjan in order to prevent related hazards. Thus, the objective of this study was to assess the risk of cancer due to the ingestion of alpha and beta emitting radionuclides in the different types of water consumed in the region. A total of 63 water samples with 43 tap water samples, 5 bottled mineral water and 15 sachet water samples was collected and taken to GAEC laboratory for analysis. The low background Gas-less Automatic Alpha/Beta counting system (Canberra iMatic<sup>TM</sup>) was used to determine alpha and beta activity concentrations. Activity concentrations of both gross alpha and gross beta obtained in water sample were respectively lower than the WHO recommended limits of 0.1 Bq/l and 1 Bq/l. Also, the annual effective dose and total equivalent effective dose found in mineral bottled water samples were higher than in other types of water. The assessment of radiological lifetime risk has shown values of cancer risk due to ingestion alpha and beta emitters lower than recommended limit. These results indicate that there is no health hazard associated to consumption of water in the District of Abidjan.