期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Simultaneous determination of flavonoids and anthraquinones in chrysanthemum by capillary electrophoresis with amperometry detection 被引量:3
1
作者 Yin Yan Zhang Zi Cheng Li Jin Kun Zhu Zhi Yong Yang Qing Jiang Wang Pin Gang He Yu Zhi Fang 《Chinese Chemical Letters》 SCIE CAS CSCD 2010年第10期1231-1234,共4页
A high-performance capillary electrophoresis with amperometry detection method (CE-AD) has been developed for the analysis of flavonoids and anthraquinones (emodin, kaempferol, apigenin, luteolin and rhein) in chr... A high-performance capillary electrophoresis with amperometry detection method (CE-AD) has been developed for the analysis of flavonoids and anthraquinones (emodin, kaempferol, apigenin, luteolin and rhein) in chrysanthemum. Under optimum conditions, these five analytes were base-line separated within 17 min using a borate-phosphate running buffer (1.5 ×10^-2 mol/L borate-3× 10^-2 mol/L phosphate running buffer, pH 9.0) at a working potential of +0.90 V (vs. SCE) and a separation voltage of 19 kV. The linear relationship between concentration and current response was obtained with detection limits (S/N = 3) ranging from 1.0 × 10^-7 to 2.1 × 10^-7 g/mL for all analytes. This proposed method was successfully used in the analysis of four kinds of chrysanthemum with relatively simple extraction procedures, the assay results were satisfactory. 展开更多
关键词 Capillary electrophoresis Amperometry detection Chrysanthemu FLAVONOIDS ANTHRAQUINONES
下载PDF
Integrated Carbon Nanotubes Electrodes in Microfluidic Chip via MWPCVD
2
作者 王升高 王明洋 +5 位作者 余冬冬 张文波 邓晓清 杜宇 程莉莉 汪建华 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第5期556-560,共5页
An on-chip electrochemical detector for microfluidic chips was described, based on integrated carbon nanotube (CNT) electrodes directly onto the chip substrate through microwave plasma chemical vapor deposition (MW... An on-chip electrochemical detector for microfluidic chips was described, based on integrated carbon nanotube (CNT) electrodes directly onto the chip substrate through microwave plasma chemical vapor deposition (MWPCVD). The attractive performance of the integrated CNT electrodes was demonstrated for the amperometric detection of sucrose, glucose and D-fructose. The integrated CNT electrodes showed stronger electrocatalytic activity than gold electrodes. 展开更多
关键词 microfluidic chip integrated carbon naotube electrodes microwave plasmachemical deposition amperometrie detection
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部