期刊文献+
共找到1篇文章
< 1 >
每页显示 20 50 100
Immediate and Intermediate Results of Patent Ductus Artriosus Transcatheter Closure in Kurdistan (Multicenter Experience)
1
作者 Aso F. Salih Abass A. Al-Rabaty Zuhair I. Al-Nasiry 《World Journal of Cardiovascular Surgery》 2016年第5期61-72,共12页
Background: Patent Ductus Artriosus (PDA) is abnormal vascular communication between aorta and pulmonary artery and it is a common congenital heart anomaly seen in pediatric practice forming 5% - 10% of all congenital... Background: Patent Ductus Artriosus (PDA) is abnormal vascular communication between aorta and pulmonary artery and it is a common congenital heart anomaly seen in pediatric practice forming 5% - 10% of all congenital heart defects. A retrospective study aims to review our experience and determine the efficacy and safety of transcatheter PDA closure in different age groups and has the procedure replaced the conventional surgical closure of the PDA in the majority of the cases. To assess the results and outcomes of early experience, transcatheter closure of patent ductus Arteriosus in all three cardiac centers in Kurdistan, using the Amplatzer Duct Occluder type I and II (ADO), and Cook coil for the first time in Kurdistan are analyzed. Patients & Methods: A total of three hundred and nine patients which included 228 females & 81 males were diagnosed to have PDA, between March 2008 to February 2011 in all three cardiac centers in Kurdistan, namely Hawler, Sulaimani and Duhok cardiac centers, where they underwent transcatheter closure of the PDA with ADO type I and II. The common age on closure was 1 - 5 years old (range 5.5 months old to 32 years old), and weight ranged from 6 kg to 58 kg. We retrospectively analyzed medical records, echocardiography, angiographic and hemodynamic data and follow-up results of the patients. Patients included in the study were according to standard recommendation for transcatheter closure of PDA, and in any age they should be above 6 kilograms with exclusion of cases with pulmonary hypertension and interrupted IVC. Results: Among 309 cases did catheterization procedures, the ratio of female to male ratio was 2.6:1 and the age of doing PDA closure at time of procedure was between 5.5 months old to 33 years old, the mean age was 6.3 ± 6.5 years old and the weight ranges between 6 kg and 58 kg, mean of 11.5 ± 7.5 kg. The most commonly used device was Amplatzer I PDA device with high closure success rate of 97.1% after 6 and 12 months followup and the first case of Amplatzer II PDA Device closure done in Iraq and Kurdistan. There was immediate & complete closure in 271 on angiography. Complication was noted as embolized PDA device to Right Pulmonary Artery (RPA) in two patients, one of them retrieved by cath and other one by surgery. Conclusion: Transcatheter Amplatzer duct occluder is safe and effective in closing PDA in most patients with PDA even large as much as 10 mm and the advantage of new Amplatzer PDA II device allows small delivery sheath in which it can be done for children with less than 6 kg with fewer complications. Disadvantage is that it cannot close more than 6 mm PDA. 展开更多
关键词 Patent Ductus Artriosus CATHETERIZATION amplatzer device EMBOLIZATION Kurdistan
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部