期刊文献+
共找到173,858篇文章
< 1 2 250 >
每页显示 20 50 100
Altered spontaneous brain activity patterns in hypertensive retinopathy using fractional amplitude of low-frequency fluctuations:a functional magnetic resonance imaging study
1
作者 Xue-Lin Wang Xu-Jun Zheng +8 位作者 Li-Juan Zhang Jin-Yu Hu Hong Wei Qian Ling Liang-Qi He Cheng Chen Yi-Xin Wang Xu Chen Yi Shao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1665-1674,共10页
AIM:To study functional brain abnormalities in patients with hypertensive retinopathy(HR)and to discuss the pathophysiological mechanisms of HR by fractional amplitude of low-frequency fluctuations(fALFFs)method.METHO... AIM:To study functional brain abnormalities in patients with hypertensive retinopathy(HR)and to discuss the pathophysiological mechanisms of HR by fractional amplitude of low-frequency fluctuations(fALFFs)method.METHODS:Twenty HR patients and 20 healthy controls(HCs)were respectively recruited.The age,gender,and educational background characteristics of the two groups were similar.After functional magnetic resonance imaging(fMRI)scanning,the subjects’spontaneous brain activity was evaluated with the fALFF method.Receiver operating characteristic(ROC)curve analysis was used to classify the data.Further,we used Pearson’s correlation analysis to explore the relationship between fALFF values in specific brain regions and clinical behaviors in patients with HR.RESULTS:The brain areas of the HR group with lower fALFF values than HCs were the right orbital part of the middle frontal gyrus(RO-MFG)and right lingual gyrus.In contrast,the values of fALFFs in the left middle temporal gyrus(MTG),left superior temporal pole(STP),left middle frontal gyrus(MFG),left superior marginal gyrus(SMG),left superior parietal lobule(SPL),and right supplementary motor area(SMA)were higher in the HR group.The results of a t-test showed that the average values of fALFFs were statistically significantly different in the HR group and HC group(P<0.001).The fALFF values of the left middle frontal gyrus in HR patients were positively correlated with anxiety scores(r=0.9232;P<0.0001)and depression scores(r=0.9682;P<0.0001).CONCLUSION:fALFF values in multiple brain regions of HR patients are abnormal,suggesting that these brain regions in HR patients may be dysfunctional,which may help to reveal the pathophysiological mechanisms of HR. 展开更多
关键词 hypertensive retinopathy fractional amplitude of low-frequency fluctuation brain region magnetic resonance imaging
下载PDF
High-Precision Doppler Frequency Estimation Based Positioning Using OTFS Modulations by Red and Blue Frequency Shift Discriminator 被引量:1
2
作者 Shaojing Wang Xiaomei Tang +3 位作者 Jing Lei Chunjiang Ma Chao Wen Guangfu Sun 《China Communications》 SCIE CSCD 2024年第2期17-31,共15页
Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Dopple... Orthogonal Time Frequency and Space(OTFS) modulation is expected to provide high-speed and ultra-reliable communications for emerging mobile applications, including low-orbit satellite communications. Using the Doppler frequency for positioning is a promising research direction on communication and navigation integration. To tackle the high Doppler frequency and low signal-to-noise ratio(SNR) in satellite communication, this paper proposes a Red and Blue Frequency Shift Discriminator(RBFSD) based on the pseudo-noise(PN) sequence.The paper derives that the cross-correlation function on the Doppler domain exhibits the characteristic of a Sinc function. Therefore, it applies modulation onto the Delay-Doppler domain using PN sequence and adjusts Doppler frequency estimation by red-shifting or blue-shifting. Simulation results show that the performance of Doppler frequency estimation is close to the Cramér-Rao Lower Bound when the SNR is greater than -15dB. The proposed algorithm is about 1/D times less complex than the existing PN pilot sequence algorithm, where D is the resolution of the fractional Doppler. 展开更多
关键词 channel estimation communication and navigation integration Orthogonal Time frequency and Space pseudo-noise sequence red-blue frequency shift discriminator
下载PDF
Coherent optical frequency transfer via 972-km fiber link 被引量:1
3
作者 邓雪 张翔 +8 位作者 臧琦 焦东东 王丹 刘杰 高静 许冠军 董瑞芳 刘涛 张首刚 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期277-282,共6页
We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase lockin... We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase locking loop in the conventional active phase control scheme,the passive phase noise cancellation is realized by feeding double-trip beat-note frequency to the driver of the acoustic optical modulator at the local site.This passive scheme exhibits fine robustness and reliability,making it suitable for long-distance and noisy fiber links.An optical regeneration station is used in the link for signal amplification and cascaded transmission.The phase noise cancellation and transfer instability of the 972-km link is investigated,and transfer instability of 1.1×10^(-19)at 10^(4)s is achieved.This work provides a promising method for realizing optical frequency distribution over thousands of kilometers by using fiber links. 展开更多
关键词 optical frequency transfer fiber link phase noise cancellation
下载PDF
Ultrafast dynamics of femtosecond laser-induced high spatial frequency periodic structures on silicon surfaces 被引量:1
4
作者 Ruozhong Han Yuchan Zhang +6 位作者 Qilin Jiang Long Chen Kaiqiang Cao Shian Zhang Donghai Feng Zhenrong Sun Tianqing Jia 《Opto-Electronic Science》 2024年第3期33-46,共14页
Femtosecond laser-induced periodic surface structures(LIPSS)have been extensively studied over the past few decades.In particular,the period and groove width of high-spatial-frequency LIPSS(HSFL)is much smaller than t... Femtosecond laser-induced periodic surface structures(LIPSS)have been extensively studied over the past few decades.In particular,the period and groove width of high-spatial-frequency LIPSS(HSFL)is much smaller than the diffraction limit,making it a useful method for efficient nanomanufacturing.However,compared with the low-spatial-frequency LIPSS(LSFL),the structure size of the HSFL is smaller,and it is more easily submerged.Therefore,the formation mechanism of HSFL is complex and has always been a research hotspot in this field.In this study,regular LSFL with a period of 760 nm was fabricated in advance on a silicon surface with two-beam interference using an 800 nm,50 fs femtosecond laser.The ultrafast dynamics of HSFL formation on the silicon surface of prefabricated LSFL under single femtosecond laser pulse irradiation were observed and analyzed for the first time using collinear pump-probe imaging method.In general,the evolution of the surface structure undergoes five sequential stages:the LSFL begins to split,becomes uniform HSFL,degenerates into an irregular LSFL,undergoes secondary splitting into a weakly uniform HSFL,and evolves into an irregular LSFL or is submerged.The results indicate that the local enhancement of the submerged nanocavity,or the nanoplasma,in the prefabricated LSFL ridge led to the splitting of the LSFL,and the thermodynamic effect drove the homogenization of the splitting LSFL,which evolved into HSFL. 展开更多
关键词 laser-induced periodic surface structures(LIPSS) local field enhancement collinear pump-probe imaging silicon high spatial frequency periodic structures
下载PDF
Microwave electrometry with Rydberg atoms in a vapor cell using microwave amplitude modulation
5
作者 郝建海 贾凤东 +9 位作者 崔越 王昱寒 周飞 刘修彬 张剑 谢锋 白金海 尤建琦 王宇 钟志萍 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期65-74,共10页
We have theoretically and experimentally studied the dispersive signal of the Rydberg atomic electromagneticallyinduced transparency(EIT)Autler–Townes(AT)splitting spectra obtained using amplitude modulation of the m... We have theoretically and experimentally studied the dispersive signal of the Rydberg atomic electromagneticallyinduced transparency(EIT)Autler–Townes(AT)splitting spectra obtained using amplitude modulation of the microwave(MW)electric field.In addition to the two zero-crossing points interval△f_(zeros),the dispersion signal has two positive maxima with an interval defined as the shoulder interval△f_(sho),which is theoretically expected to be used to measure a much weaker MW electric field.The relationship of the MW field strength E_(MW)and△f_(sho)is experimentally studied at the MW frequencies of 31.6 GHz and 9.2 GHz respectively.The results show that△f_(sho)can be used to characterize the much weaker E_(MW)than that of△f_(zeros)and the traditional EIT–AT splitting interval△f_(m);the minimum E_(MW)measured by△f_(sho)is about 30 times smaller than that by△f_(m).As an example,the minimum E_(MW)at 9.2 GHz that can be characterized by△f_(sho)is 0.056 mV/cm,which is the minimum value characterized by the frequency interval using a vapor cell without adding any auxiliary fields.The proposed method can improve the weak limit and sensitivity of E_(MW)measured by the spectral frequency interval,which is important in the direct measurement of weak E_(MW). 展开更多
关键词 quantum sensor Rydberg atoms electromagnetically induced transparency amplitude modulation
下载PDF
Physical activity volume,frequency,and intensity:Associations with hypertension and obesity over 21 years in Australian women
6
作者 Gregore I.Mielke Ding Ding +3 位作者 Shelley E.Keating Bruno P.Nunes Ruth Brady Wendy J.Brown 《Journal of Sport and Health Science》 SCIE CAS CSCD 2024年第5期631-641,共11页
Background:Optimal patterns of accrual of recommended levels of physical activity(PA)for prevention of hypertension and obesity are not known.The overall aim of this study was to investigate whether different patterns... Background:Optimal patterns of accrual of recommended levels of physical activity(PA)for prevention of hypertension and obesity are not known.The overall aim of this study was to investigate whether different patterns of accumulation of PA are differentially associated with hypertension and obesity in Australian women over 21 years.Specifically,we investigated whether,for the same weekly volume of PA,the number of sessions(frequency)and vigorousness of PA(intensity)were associated with a reduction in the occurrence of hypertension and obesity in women.Methods:Data from the 1973-1978 and 1946-1951 cohorts of the Australian Longitudinal Study on Women's Health were analyzed(n=20,588;12%-16%with a Bachelor's or higher degree).Self-reported PA,hypertension,height,and weight were collected using mail surveys every 3 years from 1998/2000 to 2019/2021.Generalized Estimating Equation models with a 3-year lag model were used to investigate the association of PA volume(metabolic equivalent min/week)(none;33-499;500-999;≥1000,weekly frequency(none;1-2 times;3-4times;5-7 times;≥8 times),and the proportion of vigorous PA to total volume of PA(none;0%;1%-33%;34%-66%;67%-100%)with odds of hypertension and obesity from 2000 to 2021.Results:The cumulative incidence of hypertension was 6%in the 1973-1978 and 23%in the 1946-1951 cohort;27%of women in the 1973-1978;and 15%in the 1946-1951 cohort developed obesity over the period.Overall,a higher volume of PA was associated with reduced odds of hypertension and obesity.When the volume of PA was considered,the odds of hypertension did not vary according to the frequency or intensity of PA.However,increased proportion of vigorous PA to the total volume of PA was associated with a small additional reduction in the risk of obe sity.Conclusion:PA volume appears to be more important than the pattern of accumulation for the prevention of hypertension and obesity.Incorporating more sessions,particularly of vigorous-intensity PA,may provide extra benefits for the prevention of obesity. 展开更多
关键词 Physical activity frequency INTENSITY Incidences EPIDEMIOLOGY WOMEN
下载PDF
MHz cut-off frequency and permeability mechanism of iron-based soft magnetic composites
7
作者 Xiao-Wei Jin Tong Li +1 位作者 Hui-Gang Shi De-Sheng Xue 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期560-564,共5页
The lack of soft magnetic composites with high power density in MHz frequency range has become an obstacle in the efficient operation of the electrical and electronic equipments.Here,a promising method to increase the... The lack of soft magnetic composites with high power density in MHz frequency range has become an obstacle in the efficient operation of the electrical and electronic equipments.Here,a promising method to increase the cut-off frequency of iron-based soft magnetic composites to hundreds of MHz is reported.The cut-off frequency is increased from 10 MHz to 1 GHz by modulating the height of the ring,the distribution of particles,and the particle size.The mechanism of cut-off frequency and permeability is the coherent rotation of domain modulated by inhomogeneous field due to the eddy current effect.An empirical formula for the cut-off frequency in a magnetic ring composed of iron-based particles is established from experimental data.This work provides an effective approach to fabricate soft magnetic composites with a cut-off frequency in hundreds of MHz. 展开更多
关键词 CUT-OFF frequency PERMEABILITY EDDY current effect SOFT magnetic composites
下载PDF
Enhancing quantum temporal steering via frequency modulation
8
作者 吴孟凯 程维文 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期239-245,共7页
Various strategies have been proposed to harness and protect space-like quantum correlations in different models under decoherence.However,little attention has been given to temporal-like correlations,such as quantum ... Various strategies have been proposed to harness and protect space-like quantum correlations in different models under decoherence.However,little attention has been given to temporal-like correlations,such as quantum temporal steering(TS),in this context.In this work,we investigate TS in a frequency-modulated two-level system coupled to a zero-temperature reservoir in both the weak and strong coupling regimes.We analyze the impact of various frequency-modulated parameters on the behavior of TS and non-Markovian.The results demonstrate that appropriate frequency-modulated parameters can enhance the TS of the two-level system,regardless of whether the system is experiencing Markovian or non-Markovian dynamics.Furthermore,a suitable ratio between modulation strength and frequency(i.e.,all zeroes of the 0th Bessel function J_(0)(δ/?))can significantly enhance TS in the strong coupling regime.These findings indicate that efficient and effective manipulation of quantum TS can be achieved through a frequency-modulated approach. 展开更多
关键词 quantum temporal steering frequency modulation DECOHERENCE
下载PDF
Frequency and Risk Factors of Neonatal Macrosomia at Labe Regional Hospital in Guinea
9
作者 Mamadou Dian Mamoudou Diallo Mamadou Mansour Diallo +10 位作者 Mamadou Chérif Diallo Alpha Mamadou Diallo Kadija Dieng Mody Abdoulaye Barry Mamadou Alpha Diallo Kadidiatou Bah Abdou Mazid Diallo El’hadj Zainoul Bah Mamadou Malal Bori Diallo Mamadou Sanou Sylla Amadou Kaké 《Open Journal of Endocrine and Metabolic Diseases》 2024年第2期26-32,共7页
Macrosomia is defined as a term birth weight greater than or equal to 4000 grams, or greater than the 90 percentile of intrauterine growth curves. Excessive weight has harmful consequences for the newborn and is a maj... Macrosomia is defined as a term birth weight greater than or equal to 4000 grams, or greater than the 90 percentile of intrauterine growth curves. Excessive weight has harmful consequences for the newborn and is a major health concern. Objectives: To determine the frequency of neonatal macrosomia, describe risk factors and neonatal and maternal complications. Materials and methods: This was a cross-sectional study carried out between January and December 2022, involving newborns whose birth weight was greater than or equal to 4000 grams admitted to the neonatology unit of the Labe regional hospital. Results: 591 deliveries were recorded, 15 of which were macrosomic, representing a frequency of 2.54%. The average age of the women was 30.26 years. History of fetal macrosomia and diabetes was 93.33 and 71.43% respectively. The mean gestational age was 38.71 ± 0.75 SA, the mean antenatal consultation was 3 ± 0.8 and the mode of delivery was caesarean section (66.67%). Third-trimester ultrasound was performed in 53.33% of cases. Macrosomic newborns were male in 80% of cases. Neonatal complications were asphyxia (60%), hypoglycemia (20%) and hypocalcemia (13.33%). Factors associated with neonatal macrosomia were diabetes (P < 0.001), history of macrosomia (P Conclusion: this study shows that the frequency of neonatal macrosomia is 2.54% with high neonatal morbidity among newborns hospitalized in the neonatology unit of the Labé regional hospital. Screening for macrosomia risk factors during pregnancy is essential to prevent perinatal complications. 展开更多
关键词 frequency MACROSOMIA Labe
下载PDF
A Synchronization Acquisition Algorithm Based on the Frequency Hopping Pulses Combining
10
作者 She Honghan Cheng Yufan +4 位作者 Zhang Wenzihan Zhang Yaohui Zhao Yuheng Shen Haoran Mou Ying 《China Communications》 SCIE CSCD 2024年第4期74-87,共14页
As modern electromagnetic environments are more and more complex,the anti-interference performance of the synchronization acquisition is becoming vital in wireless communications.With the rapid development of the digi... As modern electromagnetic environments are more and more complex,the anti-interference performance of the synchronization acquisition is becoming vital in wireless communications.With the rapid development of the digital signal processing technologies,some synchronization acquisition algorithms for hybrid direct-sequence(DS)/frequency hopping(FH)spread spectrum communications have been proposed.However,these algorithms do not focus on the analysis and the design of the synchronization acquisition under typical interferences.In this paper,a synchronization acquisition algorithm based on the frequency hopping pulses combining(FHPC)is proposed.Specifically,the proposed algorithm is composed of two modules:an adaptive interference suppression(IS)module and an adaptive combining decision module.The adaptive IS module mitigates the effect of the interfered samples in the time-domain or the frequencydomain,and the adaptive combining decision module can utilize each frequency hopping pulse to construct an anti-interference decision metric and generate an adaptive acquisition decision threshold to complete the acquisition.Theory and simulation demonstrate that the proposed algorithm significantly enhances the antiinterference and anti-noise performances of the synchronization acquisition for hybrid DS/FH communications. 展开更多
关键词 adaptive anti-interference frequency hopping synchronization acquisition
下载PDF
Mechanical Complications of Osteosynthesis: Frequency and Management at the Orthopedics-Traumatology Department of CHU Ignace DEEN
11
作者 Tafsir Camara Amira Aboud +5 位作者 Ibrahima Sory Bangoura Madjirabe Nassaradengar Hippolyte Mohamed Youla Urbain Judicael Adou Kouassi Bah Mohamed Lamine Léopold Lamah 《Open Journal of Orthopedics》 2024年第9期404-410,共7页
Introduction: Mechanical complications after osteosynthesis are spontaneous and harmful modifications of the joint compromising the consolidation process. The aim of this study is to report on the frequency of these c... Introduction: Mechanical complications after osteosynthesis are spontaneous and harmful modifications of the joint compromising the consolidation process. The aim of this study is to report on the frequency of these complications and their management in the Orthopaedic-Traumatology Department of CHU Ignace Deen. Patients and Methods: we conducted a retrospective descriptive and analytical cross-sectional study from January 2017 to December 2022. It focused on the records of patients hospitalized and treated in the department for a mechanical complication after osteosynthesis. Results: The frequency of mechanical complications was 1.2%, with an average age of 44.2 years and a sex ratio of 3.2 in favor of men. Non-compliance with postoperative instructions, non-compliance with surgical technique, postoperative infection and early loading were the main contributing factors. Disassembly of the screw-plate was the most common cause in 6 cases (35.5%), with a mean delay of 4.1 months. Revision osteosynthesis was carried out using screw plates in 8 cases (47.1%). Conclusion: Mechanical complications of osteosynthesis are less frequent traumatic conditions in our department. Several factors contribute to their occurrence. 展开更多
关键词 Mechanical Complications frequency THERAPEUTICS OSTEOSYNTHESIS
下载PDF
Robust free-space optical frequency transfer in time-varying link distances conditions
12
作者 童周 刘雷 +6 位作者 王家亮 操前 金志成 应康 韩申生 韩正甫 桂有珍 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期271-276,共6页
Future inter-satellite clock comparison on high orbit will require optical time and frequency transmission technology between moving objects.Here,we demonstrate robust optical frequency transmission under the conditio... Future inter-satellite clock comparison on high orbit will require optical time and frequency transmission technology between moving objects.Here,we demonstrate robust optical frequency transmission under the condition of variable link distance.This variable link is accomplished by the relative motion of a single telescope fixed on the experimental platform to a corner-cube reflector(CCR)installed on a sliding guide.Two acousto–optic modulators with different frequencies are used to separate forward signal from backward signal.With active phase noise suppression,when the CCR moves back and forth at a constant velocity of 20 cm/s and an acceleration of 20 cm/s^(2),we achieve the best frequency stability of 1.9×10^(-16) at 1 s and 7.9×10^(-19) at 1000 s indoors.This work paves the way for future studying optical frequency transfer between ultra-high-orbit satellites. 展开更多
关键词 FREE-SPACE optical frequency transfer variable link distance
下载PDF
Research on Automatic Test System of Engine Blade Natural Frequency
13
作者 LU Yonghua LIU Jingjing +2 位作者 YANG Haibo HUANG Chuan MA Zhicheng 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2024年第4期476-487,共12页
Blades are one of the important components on aircraft engines.If they break due to vibration failure,the normal operation of the entire engine will be offected.Therefore,it is necessary to measure their natural frequ... Blades are one of the important components on aircraft engines.If they break due to vibration failure,the normal operation of the entire engine will be offected.Therefore,it is necessary to measure their natural frequency before installing them on the engine to avoid resonance.At present,most blade vibration testing systems require manual operation by operators,which has high requirements for operators and the testing process is also very cumbersome.Therefore,the testing efficiency is low and cannot meet the needs of efficient testing.To solve the current problems of low testing efficiency and high operational requirements,a high-precision and high-efficiency automatic test system is designed.The testing accuracy of this system can reach ±1%,and the testing efficiency is improved by 37% compared to manual testing.Firstly,the influence of compression force and vibration exciter position on natural frequency test is analyzed by amplitude-frequency curve,so as to calibrate servo cylinder and fourdimensional motion platform.Secondly,the sine wave signal is used as the excitation to sweep the blade linearly,and the natural frequency is determined by the amplitude peak in the frequency domain.Finally,the accuracy experiment and efficiency experiment are carried out on the developed test system,whose results verify its high efficiency and high precision. 展开更多
关键词 BLADE vibration failure natural frequency automatic test system
下载PDF
Gigahertz frequency hopping in an optical phase-locked loop for Raman lasers
14
作者 毛德凯 税鸿冕 +3 位作者 殷国玲 彭鹏 王春唯 周小计 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期60-65,共6页
Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping appro... Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping approach of a slave Raman laser within an optical phase-locked loop(OPLL),which finds practical application in an atomic gravimeter,where the OPLL frequently switches between near-resonance lasers and significantly detuned Raman lasers.The method merges the advantages of rapid and extensive frequency hopping with the OPLL’s inherent low phase noise,and exhibits a versatile range of applications in compact laser systems,promising advancements in portable instruments. 展开更多
关键词 Raman lasers optical phase-locked loop frequency hopping
下载PDF
Frequency-modulated continuous-wave multiplexed gas sensingbased on optical frequency comb calibration
15
作者 Linhua Jia Xinghua Qu Fumin Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期152-163,共12页
Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed ga... Laser absorption spectroscopy has proven to be an effective approach for gas sensing, which plays an important rolein the fields of military, industry, medicine and basic research. This paper presents a multiplexed gas sensing system basedon optical frequency comb (OFC) calibrated frequency-modulated continuous-wave (FMCW) tuning nonlinearity. Thesystem can be used for multi-parameter synchronous measurement of gas absorption spectrum and multiplexed opticalpath. Multi-channel parallel detection is realized by combining wavelength division multiplexing (WDM) and frequencydivision multiplexing (FDM) techniques. By introducing nonlinear optical crystals, broadband spectrum detection is simultaneouslyachieved over a bandwidth of hundreds of nanometers. An OFC with ultra-high frequency stability is used asthe frequency calibration source, which guarantees the measurement accuracy. The test samples involve H13C14N, C_(2)H_(2)and Rb vapor cells of varying densities and 5 parallel measurement experiments are designed. The results show that themeasurement accuracies of spectral absorption line and the optical path are 150 MHz and 20 m, respectively. The schemeoffers the advantages of multiplexed, multi-parameter, wide spectrum and high resolution detection, which can realize theidentification of multi-gas components and the high-precision inversion of absorption lines under different environments.The proposed sensor demonstrates great potential in the field of high-resolution absorption spectrum measurement for gassensing applications. 展开更多
关键词 frequency-modulated CONTINUOUS-WAVE (FMCW) technology optical frequency COMB MULTIPLEXING absorption spectroscopy
下载PDF
Exploration of instantaneous frequency for local control assessment in real-time hybrid simulation
16
作者 Xu Weijie Peng Changle +1 位作者 Guo Tong Chen Cheng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第4期995-1008,共14页
Local control parameters such as instantaneous delay and instantaneous amplitude play an essential role in evaluating the performance and maintaining the stability of real-time hybrid simulation(RTHS).However,existing... Local control parameters such as instantaneous delay and instantaneous amplitude play an essential role in evaluating the performance and maintaining the stability of real-time hybrid simulation(RTHS).However,existing methods have limitations in obtaining this local assessment in either the time domain or frequency domain.In this study,the instantaneous frequency is introduced to determine local control parameters for actuator tracking assessment in a real-time hybrid simulation.Instantaneous properties,including amplitude,delay,frequency and phase,are then calculated based on analytic signals translated from actuator tracking signals through the Hilbert transform.Potential issues are discussed and solutions are proposed for calculation of local control parameters.Numerical simulations are first conducted for sinusoidal and chirp signals with time varying amplitude error and delay to demonstrate the potential of the proposed method.Laboratory tests also are conducted for a predefined random signal as well as the RTHS of a single degree of freedom structure with a self-centering viscous damper to experimentally verify the effectiveness of the proposed use of the instantaneous frequency.Results from the ensuing analysis clearly demonstrate that the instantaneous frequency provides great potential for local control assessment,and the proposed method enables local tracking parameters with good accuracy. 展开更多
关键词 real-time hybrid simulation tracking assessment instantaneous frequency Hilbert transform
下载PDF
Optical frequency comb technology: from ground to space
17
作者 Xiaodong Shao Yu Yan +1 位作者 Hainian Han Zhiyi Wei 《Astronomical Techniques and Instruments》 CSCD 2024年第2期105-116,共12页
Optical frequency combs,as powerful tools for precision spectroscopy and research into optical frequency standards,have driven continuous progress and significant breakthroughs in applications such as time-frequency t... Optical frequency combs,as powerful tools for precision spectroscopy and research into optical frequency standards,have driven continuous progress and significant breakthroughs in applications such as time-frequency transfer,measurement of fundamental physical constants,and high-precision ranging,achieving a series of milestone results in ground-based environments.With the continuous maturation and evolution of femtosecond lasers and related technologies,optical frequency combs are moving from ground-based applications to astronomical and space-based applications,playing an increasingly important role in atomic clocks,exoplanet observations,gravitational wave measurements,and other areas.This paper,focusing on astronomical and space-based applications,reviews research progress on astronomical frequency combs,optical clock time-frequency networks,gravitational waves,dark matter measurement,dual-comb large-scale absolute ranging,and high-resolution atmospheric spectroscopy.With enhanced performance and their gradual application in the field of space-based research,optical frequency combs will undoubtedly provide more powerful support for astronomical science and cosmic exploration in the future. 展开更多
关键词 Optical frequency comb Astronomical comb Optical clock-based time and frequency network Gravitational waves and dark matter Dual-comb ranging
下载PDF
The Impact of Model Based Offset Scaling Technique on the Amplitude Variation with Offset Responses from 3D Seismic Data Acquired from the Tano Basin, Offshore Ghana
18
作者 Striggner Bedu-Addo Sylvester Kojo Danuor Aboagye Menyeh 《International Journal of Geosciences》 CAS 2024年第1期40-53,共14页
Amplitudes have been found to be a function of incident angle and offset. Hence data required to test for amplitude variation with angle or offset needs to have its amplitudes for all offsets preserved and not stacked... Amplitudes have been found to be a function of incident angle and offset. Hence data required to test for amplitude variation with angle or offset needs to have its amplitudes for all offsets preserved and not stacked. Amplitude Variation with Offset (AVO)/Amplitude Variation with Angle (AVA) is necessary to account for information in the offset/angle parameter (mode converted S-wave and P-wave velocities). Since amplitudes are a function of the converted S- and P-waves, it is important to investigate the dependence of amplitudes on the elastic (P- and S-waves) parameters from the seismic data. By modelling these effects for different reservoir fluids via fluid substitution, various AVO geobody classes present along the well and in the entire seismic cube can be observed. AVO analysis was performed on one test well (Well_1) and 3D pre-stack angle gathers from the Tano Basin. The analysis involves creating a synthetic model to infer the effect of offset scaling techniques on amplitude responses in the Tano basin as compared to the effect of unscaled seismic data. The spectral balance process was performed to match the amplitude spectra of all angle stacks to that of the mid (26°) stack on the test lines. The process had an effect primarily on the far (34° - 40°) stacks. The frequency content of these stacks slightly increased to match that of the near and mid stacks. In offset scaling process, the root mean square (RMS) amplitude comparison between the synthetic and seismic suggests that the amplitude of the far traces should be reduced relative to the nears by up to 16%. However, the exact scaler values depend on the time window considered. This suggests that the amplitude scaling with offset delivered from seismic processing is only approximately correct and needs to be checked with well synthetics and adjusted accordingly prior to use for AVO studies. The AVO attribute volumes generated were better at resolving anomalies on spectrally balanced and offset scaled data than data delivered from conventional processing. A typical class II AVO anomaly is seen along the test well from the cross-plot analysis and AVO attribute cube which indicates an oil filled reservoir. 展开更多
关键词 amplitude Variation with Offset (AVO) Model Based Offset Scaling Technique Tano Basin
下载PDF
Seismic evaluation of frequency influence and resonant behavior for lead rubber bearing isolated rigid rectangular liquid tanks
19
作者 Jyoti Ranjan Barik Kishore Chandra Biswal 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第4期973-994,共22页
The seismic behavior of a partially filled rigid rectangular liquid tank is investigated under short-and longduration ground motions.A finite element model is developed to analyze the liquid domain by using four-noded... The seismic behavior of a partially filled rigid rectangular liquid tank is investigated under short-and longduration ground motions.A finite element model is developed to analyze the liquid domain by using four-noded quadrilateral elements.The competency of the model is verified with the available results.Parametric studies are conducted for the dynamic parameters of the base-isolated tank,using a lead rubber bearing to evaluate the optimum damping and time period of the isolator.The application of base isolation has reduced the total and impulsive hydrodynamic components of pressure by 80 to 90 percent,and base shear by 15 to 95 percent,depending upon the frequency content and duration of the considered earthquakes.The sloshing amplitude of the base-isolated tank is reduced by 18 to 94 percent for most of the short-duration earthquakes,while it is increased by 17 to 60 percent for the majority of the long-duration earthquakes.Furthermore,resonance studies are carried out through a long-duration harmonic excitation to obtain the dynamic behavior of non-isolated and isolated tanks,using a nonlinear sloshing model.The seismic responses of the base-isolated tank are obtained as higher when the excitation frequency matches the fundamental sloshing frequency rather than the isolator frequency. 展开更多
关键词 lead rubber bearing frequency domain resonant inputs long-duration excitation
下载PDF
Spin wave resonance frequency in bilayer ferromagnetic films with the biquadratic exchange interaction
20
作者 Xiaojie Zhang Yuting Wang +3 位作者 Yanqiu Chang Huan Wang Jianhong Rong Guohong Yun 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期607-613,共7页
The dependences of spin wave resonance(SWR)frequency on the surface anisotropy field,interface exchange coupling,symmetry,biquadratic exchange(BQE)interaction,film thickness,and the external magnetic field in bilayer ... The dependences of spin wave resonance(SWR)frequency on the surface anisotropy field,interface exchange coupling,symmetry,biquadratic exchange(BQE)interaction,film thickness,and the external magnetic field in bilayer ferromagnetic films are theoretically analyzed by employing the linear spin wave approximation and Green’s function method.A remarkable increase of SWR frequency,except for energetically lower two modes,can be obtained in our model that takes the BQE interaction into account.Again,the effect of the external magnetic field on SWR frequency can be increased by increasing the biquadratic to interlayer exchange ratio.It has been identified that the BQE interaction is of utmost importance in improving the SWR frequency of the bilayer ferromagnetic films.In addition,for bilayer ferromagnetic films,the frequency gap between the energetically highest mode and lowest mode is found to increase by increasing the biquadratic to interlayer exchange ratio and film thickness and destroying the symmetry of the system.These results can be used to improve the understanding of magnetic properties in bilayer ferromagnetic films and thus may have prominent implications for future magnetic devices. 展开更多
关键词 SPIN WAVE RESONANCE frequency biquadratic EXCHANGE interaction interface EXCHANGE coupling surface ANISOTROPY
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部