Design of Barrier-free Evacuation for Diverse Crowd on Campus Based on Evacuation Simulation: A Case Study of North China University of Technology
1
作者 ZHANG Zonghui SONG Rui +1 位作者 AN Zeyi ZHAO Xingmin 《Journal of Landscape Research》 2024年第5期19-26,共8页
By using evacuation simulation technology and taking North China University of Technology as an example,the barrier-free evacuation design scheme for groups with different needs in campus environment was deeply discus... By using evacuation simulation technology and taking North China University of Technology as an example,the barrier-free evacuation design scheme for groups with different needs in campus environment was deeply discussed.Based on the data of building layout,population composition,road system and distribution of shelters in the school,a detailed evacuation model was constructed in the Pathfinder emergency evacuation simulation system.By the simulation during the daytime and at night,the total evacuation time of the whole school,evacuation completion time of each building,selection of evacuation paths and shelter utilization were analyzed in detail.The simulation results show that the distribution of shelters on campus is uneven,and their capacity is limited.As a result,the evacuation paths of the disabled,the elderly and children need to be adjusted frequently,which affects the overall evacuation efficiency.In view of this,the optimization strategies of road renovation and entrances of shelters and buildings were put forward from the perspective of space planning.From the perspective of emergency management,it is suggested to improve the campus evacuation infrastructure and strengthen the evacuation drill for teachers and students.These results provide a solid theoretical support for enhancing the construction of campus barrier-free environment and improving the level of emergency management. 展开更多
关键词 Diverse crowd Campus barrier-free evacuation design analogue simulation SHELTER
下载PDF
Simulation of Seabed Erosion Produced by an Inclined Jet 被引量:1
2
作者 Zhibin Zhang Yongjun Gong +2 位作者 Liping Zhang Min Xv Gaofeng Shang 《Fluid Dynamics & Materials Processing》 EI 2023年第3期651-662,共12页
Water jets are widely used in seabed scouring and desilting applications.In the present work,dedicated tests have been conducted using a jet scour model test platform and sand beds containing grains with different siz... Water jets are widely used in seabed scouring and desilting applications.In the present work,dedicated tests have been conducted using a jet scour model test platform and sand beds containing grains with different sizes.The FLOW-3D simulation software has also been used to tackle the problem form a numerical point of view.The boundary conditions of the simulation have been optimized to reduce the gap between the numerical results and the outcomes of the experimental tests.Scour area calculation has been based on a RNG k-εTurbulence model.Moreover,the FAVOR(Fractional Area Volume Obstacle Representation)technology has been selected for grid division to make the simulation results more accurate.Jet scours with inclination angles of 10–20°have been simulated.It has been found that jet scouring is greatly affected by the environmental water flow,that is,water flow can weaken the scouring capacity of the jets. 展开更多
关键词 Inclined jet mobile environment analogue simulation jet ratio scouring area
下载PDF
Effectiveness of Epidemic Control in Shopping Centers Based on Anylogic Platform: A Case Study of Handan Weilaishi Shopping Center 被引量:1
3
作者 REN Hongguo MA Tianyu LIU Yuchen 《Journal of Landscape Research》 2022年第2期16-19,24,共5页
From the perspective of COVID-19’s prevention and control, to test effectiveness of existing control measures for shopping center buildings, taking Weilaishi Shopping Center of Handan City as an example, Anylogic sof... From the perspective of COVID-19’s prevention and control, to test effectiveness of existing control measures for shopping center buildings, taking Weilaishi Shopping Center of Handan City as an example, Anylogic software is used for analogue simulation of the whole shopping process. According to existing control means of Weilaishi Shopping Center, the model sets three different simulation conditions: “no control state”, “restricting entrance and exit opening” and “increasing epidemic prevention distance”. The epidemic prevention effects of different control methods are intuitively displayed through the simulated output thermal diagram and the statistical diagram of the number of infected people. The results show that restricting the opening of entrances and exits can reduce the number of infected people by 36%, and increasing the epidemic prevention distance can reduce the number of infected people by 89.8%. Both control methods can play a certain epidemic prevention effect. 展开更多
关键词 COVID-19 Shopping center Control means analogue simulation
下载PDF
Research on Thermal Management Control Strategy of Electric Vehicle Liquid Cooling Battery Pack
4
作者 Zhenhua Li 《Modern Electronic Technology》 2021年第2期36-40,共5页
Due to the risk of thermal runaway in the charging and discharging process of a soft packed lithium battery pack for electric vehicles,a stamping channel liquid cooling plate cooling system is designed,and then the he... Due to the risk of thermal runaway in the charging and discharging process of a soft packed lithium battery pack for electric vehicles,a stamping channel liquid cooling plate cooling system is designed,and then the heat dissipation problem of the battery pack is solved through reasonable thermal management control strategy.Using computational fluid dynamics simulation software star-CCM+,the thermal management control strategy is optimized through simulation technology,and the temperature field distribution of battery pack is obtained.Finally,an experimental platform is built,combined with experiments,the effectiveness of the thermal management control strategy of the cooling system is verified.The results show that when the battery pack is in the environment of 25℃,the maximum temperature of the cooling system can be lower than 40℃,the maximum temperature difference between all single batteries is within 5℃,and the maximum temperature difference between inlet and outlet coolant is 3℃,which can meet the heat dissipation requirements of the battery pack and prevent out of control heat generation. 展开更多
关键词 Electric vehicle Power battery liquid cooling system Computational fluid dynamics analogue simulation
下载PDF