A single molecule detection technique was developed by the combination of a single channel poly (dimethylsiloxane)/glass micro-fluidic chip and fluorescence correlation spectroscopy (FCS). This method was successf...A single molecule detection technique was developed by the combination of a single channel poly (dimethylsiloxane)/glass micro-fluidic chip and fluorescence correlation spectroscopy (FCS). This method was successfully used to determine the proportion of two model components in the mixture containing fluorescein and the rhodamine-green succinimidyl ester.展开更多
The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced flu...The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced fluorescence detection system is presented. Based on the debugging of optical and circuit modules, the results of detecting the samples are given and analyzed theoretically, and the improved project is put forward.展开更多
Four basic explicit analytical solutions of non_Fourier heat conduction equation simulating IC chip thermal condition are derived. Some other analytical series solutions can also be derived with the above_mentioned ba...Four basic explicit analytical solutions of non_Fourier heat conduction equation simulating IC chip thermal condition are derived. Some other analytical series solutions can also be derived with the above_mentioned basic solutions. Analytical solution has its own irreplaceable important meaning in theory. In addition, as the standard solution to check the accuracy, convergence and effectiveness of various numerical computational methods and their differencing schemes, grid generation ways and so on, the analytical solution is very useful also for the newly rapidly developing computational heat transfer.展开更多
An analytical model is proposed for input buffer router architecture Network-on-Chip (NoC) with finite size buffers. The model is developed based on M/G/ 1/K queuing theory and takes into consideration the restricti...An analytical model is proposed for input buffer router architecture Network-on-Chip (NoC) with finite size buffers. The model is developed based on M/G/ 1/K queuing theory and takes into consideration the restriction of buffer sizes in NoC. It analyzes the packet's sojourn time in each buffer and calculates the packets average latency in NoC The validity of the model is verified through simulation. By comparing our analytical outcomes to the simulation results, we show that the proposed model successfully captures the performance characteristics of NoC, which provides an efficient performance analysis tool for NoC design.展开更多
为了解决非专业人群寻找穴位难、不准确、不易操作等难题,设计了一种以SPCE061A为核心MCU(Micro Control Unit)的简易人体穴位识别治疗仪。给出了系统结构和实现流程,提出了一种基于层次分析原理的新型穴位检测方法,并讨论了环境因素对...为了解决非专业人群寻找穴位难、不准确、不易操作等难题,设计了一种以SPCE061A为核心MCU(Micro Control Unit)的简易人体穴位识别治疗仪。给出了系统结构和实现流程,提出了一种基于层次分析原理的新型穴位检测方法,并讨论了环境因素对穴位识别结果的影响。通过人体穴位检测实验表明,本系统的穴位与非穴位正确识别率可分别达到95%和98%以上,且输出频率可调、波形可变的脉冲电压可达到模拟中医针灸治疗的作用。与传统找穴位方法相比,该方案具有操作简单、功耗低、性价比高等优点。展开更多
基金This work was financially supported by the National Natural Science Foundation of China. (No.20271033, 20335020, 90408014).
文摘A single molecule detection technique was developed by the combination of a single channel poly (dimethylsiloxane)/glass micro-fluidic chip and fluorescence correlation spectroscopy (FCS). This method was successfully used to determine the proportion of two model components in the mixture containing fluorescein and the rhodamine-green succinimidyl ester.
基金Key Science and Technology Project Tackled of Guangdong Province(B2050070)
文摘The characteristics such as signal noise ratio(SNR) and sensitivity of the fluorescence detection system for micro-fluidic chip influence the performance of the whole system extremely. The confocal laser induced fluorescence detection system is presented. Based on the debugging of optical and circuit modules, the results of detecting the samples are given and analyzed theoretically, and the improved project is put forward.
文摘Four basic explicit analytical solutions of non_Fourier heat conduction equation simulating IC chip thermal condition are derived. Some other analytical series solutions can also be derived with the above_mentioned basic solutions. Analytical solution has its own irreplaceable important meaning in theory. In addition, as the standard solution to check the accuracy, convergence and effectiveness of various numerical computational methods and their differencing schemes, grid generation ways and so on, the analytical solution is very useful also for the newly rapidly developing computational heat transfer.
文摘An analytical model is proposed for input buffer router architecture Network-on-Chip (NoC) with finite size buffers. The model is developed based on M/G/ 1/K queuing theory and takes into consideration the restriction of buffer sizes in NoC. It analyzes the packet's sojourn time in each buffer and calculates the packets average latency in NoC The validity of the model is verified through simulation. By comparing our analytical outcomes to the simulation results, we show that the proposed model successfully captures the performance characteristics of NoC, which provides an efficient performance analysis tool for NoC design.
文摘为了解决非专业人群寻找穴位难、不准确、不易操作等难题,设计了一种以SPCE061A为核心MCU(Micro Control Unit)的简易人体穴位识别治疗仪。给出了系统结构和实现流程,提出了一种基于层次分析原理的新型穴位检测方法,并讨论了环境因素对穴位识别结果的影响。通过人体穴位检测实验表明,本系统的穴位与非穴位正确识别率可分别达到95%和98%以上,且输出频率可调、波形可变的脉冲电压可达到模拟中医针灸治疗的作用。与传统找穴位方法相比,该方案具有操作简单、功耗低、性价比高等优点。