期刊文献+
共找到1,793篇文章
< 1 2 90 >
每页显示 20 50 100
Anterior Chamber Depth Changes in Narrow Iridocorneal Angles after Phacoemulsification
1
作者 Md. Ariful Islam Abir Bin Sajj +2 位作者 Tohura Sharmin Md. Sanwar Hossain Md. Shafiqul Islam 《Open Journal of Ophthalmology》 2023年第2期187-198,共12页
Background: The burden of cataract and glaucoma has been increasing. Primary angle closure occurs as a result of crowded anterior segment anatomy causing appositional contact between peripheral iris and trabecular mes... Background: The burden of cataract and glaucoma has been increasing. Primary angle closure occurs as a result of crowded anterior segment anatomy causing appositional contact between peripheral iris and trabecular meshwork. Lens extraction has been proposed as a method of deepening anterior chamber and managing intraocular pressure. Purpose: To assess changes in anterior chamber depth after phacoemulsification with intraocular lens implantation in narrow angle eyes. Design: Prospective controlled trial (before-after) study. Method: The study was conducted from March 2015 to August 2017 among the patients of department of Ophthalmology of BSMMU who were diagnosed as cataract with narrow angles. Anterior chamber angle grading of 2 or less (Shaffer grading) in 3 or more quadrants was considered narrow angle (NA). The purposive type sampling technique was applied to collect sample from the study population, as per inclusion and exclusion criteria. Complete clinical evaluation including history, physical examination, relevant ocular examinations and systemic examinations were performed. In this prospective study, subjects underwent phacoemulsification with foldable lens implantation. A scan ultrasonography was performed preoperatively and 10<sup>th</sup> and 30<sup>th</sup> postoperative days of surgery. Results: Thirty eyes of 29 patients included in the study, male: female ratio was 1:1, with an overall mean age of 62.03 ± 8.95 years. The mean preoperative central ACD was 2.95 ± 0.35 mm. At 10<sup>th</sup> and 30<sup>th</sup> POD mean central ACD were 3.94 ± 0.32, and 3.92 ± 0.28 mm respectively. Mean of increase in central ACD at final follow-up was 0.96 mm (p Conclusion: Phacoemulsification with posterior chamber in bag lens implantation can deepen the anterior chamber depth in patients with narrow angles. Based on these findings, it is concluded that phacoemulsification with foldable intraocular lens implantation is an effective tool in deepening the anterior chamber. 展开更多
关键词 anterior chamber Depth PHACOEMULSIFICATION Iridocorneal angles Open angle Narrow angle
下载PDF
Effect of low dose laser cycloplasty on deepening anterior chamber in chronic angle-closure glaucoma 被引量:2
2
作者 Xuan-Li Zheng Hai-Shuang Lin +4 位作者 Xiao-Jie Wang Jia-Qian Li Yan-Qian Xie Shao-Dan Zhang Yuan-Bo Liang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第12期2011-2017,共7页
AIM:To describe the outcome of using low-dose laser cycloplasty(LCP)in chronic angle-closure glaucoma(CACG).METHODS:A retrospective case series.Medical charts of CACG patients who underwent LCP in the Eye Hospital of ... AIM:To describe the outcome of using low-dose laser cycloplasty(LCP)in chronic angle-closure glaucoma(CACG).METHODS:A retrospective case series.Medical charts of CACG patients who underwent LCP in the Eye Hospital of Wenzhou Medical University were reviewed.The main outcomes included intraocular pressure(IOP),the number of glaucoma medication,anterior segment parameters and surgery-related complications.RESULTS:A total of 7 eyes of 7 CACG patients(age 38.9±11.0y)underwent LCP with a mean follow-up of 27.1±13.7mo(range 16-48mo).Following LCP,mean IOP and glaucoma medications decreased from 26.1±6.1 mm Hg with 3.1±1.1 glaucoma medications pre-treatment to 14.9±3.1 mm Hg(P=0.027)with 0.4±1.1 glaucoma medications(P=0.001)at final follow-up.The anterior chamber depth(ACD),angle opening distance500 and trabecular-iris angle increased from 1.65±0.33 mm,0.05 mm(range 0-0.30 mm)and 5.1°(range,0-31.97°)at baseline to 1.98±0.43 mm(P=0.073),0.53 mm(range 0.42-0.91 mm,P=0.015),45.9°(range,40.2°-59.4°),(P=0.015)in the long-term follow-up,respectively.The deepening of ACD and reopening of anterior chamber angle(ACA)was observed in 6 eyes(85.7%).CONCLUSION:LCP is a promising treatment option for patients with CACG via reducing IOP and glaucoma medication without serious complications.In addition,LCP can bring a significant deepening in ACD and reopening of ACA. 展开更多
关键词 chronic angle-closure glaucoma low dose laser cycloplasty anterior chamber depth intraocular pressure
下载PDF
Comparison of measurements of anterior chamber angle via anterior segment optical coherence tomography and ultrasound biomicroscopy 被引量:2
3
作者 Zi-Yan Yu Ting Huang +1 位作者 Lu Lu Bo Qu 《World Journal of Clinical Cases》 SCIE 2020年第15期3249-3258,共10页
BACKGROUND Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision.The variable clinical manifestations may result in differential diagnostic difficulties.The early screening ... BACKGROUND Glaucoma is an irreversible optic neuropathy with the loss of visual field and decrease of vision.The variable clinical manifestations may result in differential diagnostic difficulties.The early screening and diagnosis of glaucoma are currently experiencing a demand for anterior segment analysis tools that can gather more information with one short measurement.Therefore,we analyzed the agreement,difference,and correlation of chamber angle parameters such as angel opening distance at 500μm(AOD500)and trabeculo-iris space area at 500μm^2(TISA500)measured by anterior segment optical coherence tomography(ASOCT)and ultrasound biomicroscopy(UBM).AIM To compare the differences,correlation,and agreement in measuring AOD500 and TISA500 by AS-OCT and UBM.METHODS Both AS-OCT and UBM were performed to measure AOD500 and TISA500 in 45 subjects(72 eyes).All subjects without glaucoma were collected from October 2015 to August 2016 at the Ophthalmology Department of the Fourth Affiliated Hospital of China Medical University.Data of the two groups(AOD500 and TISA500)were compared by nonparametric tests.Pearson correlative analysis and Bland-Altman analysis were used to compare the correlation and agreement.RESULTS There were no significant differences between AS-OCT and UBM in measuring AOD500(P1=0.110,P2=0.633,P3=0.078,and P4=0.474)and TISA500(P1=0.584,P2=0.889,P3=0.297,and P4=0.550)of the four quadrants of the anterior chamber angle.There was a high correlation in measuring AOD500(r1=0.562,r2=0.671,r3=0.635,and r4=0.720;P<0.001)and TISA500(r1=0.584,r2=0.889,r3=0.297,and r4=0.550;P<0.001).There was a good agreement in measuring AOD500 and TISA500 by the two modalities.CONCLUSION There is a high correlation and agreement between AOD500 and TISA500 measurements by AS-OCT and UBM.They are interchangeable under some circumstances.AS-OCT proves to be a better early screening tool for glaucoma. 展开更多
关键词 anterior segment-optical coherence tomography Primary angle closure glaucoma anterior chamber angle Angel opening distance at 500 m Trabeculo-iris space area at 500 m^2
下载PDF
Evaluation of Nasal and Temporal Anterior Chamber Angle with Four Different Techniques
4
作者 Fredrik PKallmark Mezghan Sakhi 《International Journal of Clinical Medicine》 2013年第12期548-555,共8页
Background: Anterior chamber angle (ACA) can be measured by many different techniques. In order for a technique to be a part of the routine eye examination, it has to be quick and easy in good agreement with gonioscop... Background: Anterior chamber angle (ACA) can be measured by many different techniques. In order for a technique to be a part of the routine eye examination, it has to be quick and easy in good agreement with gonioscopy both nasally and temporally. Aim: To investigate variation in ACA measurement between gonioscopy, van Herick technique, anterior segment optical coherence tomography (AS-OCT) and Sirius Scheimpflug-Camera both nasally and temporally. Method: The ACA of 50 eyes of 25 healthy subjects was measured with gonioscopy, van Herick technique, AS-OCT and Sirius Scheimpflug-Camera. The angle was measured both nasally and temporally. Results: No statistically significant difference could be found between gonioscopy, van Herick technique and AS-OCT either nasally or temporally. The Sirius Scheimpflug-Camera on the other hand showed statistically significant difference to gonioscopy (p < 0.0001) both nasally (p = 0.03, p = 0.001, p < 0.0001) and temporally (p = 0.0002, p = 0.001, p Conclusion: This study showed good agreement between three of the four techniques. ACA measurements obtained by the Sirius Scheimpflug-Camera should therefore not be considered interchangeable with those obtained by the remaining three methods. 展开更多
关键词 anterior chamber angle (ACA) GONIOSCOPY Van Herick Technique Sirius Scheimpflug Camera AS-OCT angle Closure Glaucoma
下载PDF
Assessment of anterior chamber angle changes after phacoemulsification with swept-source OCT 被引量:3
5
作者 Qian Zheng Man Hu +2 位作者 Zhang-Liang Li Ping-Jun Chang Yun-E Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第10期1527-1532,共6页
AIM:To assess the changes of anterior chamber angle in patients with shallow anterior chamber after phacoemulsification combined with intraocular lens(IOL)implantation,based on anterior segment swept-source optical co... AIM:To assess the changes of anterior chamber angle in patients with shallow anterior chamber after phacoemulsification combined with intraocular lens(IOL)implantation,based on anterior segment swept-source optical coherence tomography(AS-SS-OCT)measurements.METHODS:This was a prospective case control study;sixty eyes of sixty case were scheduled for cataract surgery with normal intraocular pressure(IOP).Based on anterior chamber depth(ACD)and gonioscopy findings,the eyes were divided into two groups:group of shallow anterior chamber and narrow angle(SAC group,30 eyes);and group of normal anterior chamber group with wide angle(NAC group,30 eyes).Measurements of ACD,anterior chamber volume(ACV),iris volume(IV),lens vault(LV),angle opening distance(AOD),angle recess area(ARA),trabecular iris space area(TISA),and trabecular iris angle(TIA)were conducted in each group before and 3mo after surgery.RESULTS:There was no significant difference in age,axial length(AL),corneal curvature,corneal diameter,intraocular pressure,and IV between two groups before surgery,except for the LV(P=0.000).ACD and ACV were prominently larger in the NAC group than the SAC group 3mo after operation(3.69±0.38 vs 3.85±0.39 mm,P=0.025;161.37±19.47 vs 178.26±20.30 mm3,P=0.002).AOD750,ARA750 in nasal and inferior quadrants,TISA750 in all quadrants except temporal,and TIA750 in all quadrants in SAC group were significantly smaller than those in NAC group after operation(all P<0.05).CONCLUSION:Cataract surgery can deepen anterior chamber and increase the width of anterior chamber angle in Chinese subjects,but the angle related parameters including AOD750,ARA750,TISA750,TIA,TISA750,and ACV in patients with shallow anterior chamber and narrow angle do not reach the normal level. 展开更多
关键词 anterior chamber parameters PHACOEMULSIFICATION shallow anterior chamber anterior segment swept-source optical coherence tomography
下载PDF
Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps
6
作者 Yan-Ming Huang Hua Yan +1 位作者 Jin-Hong Cai Hai-Bo Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第5期749-753,共5页
AIM:To introduce a novel approach in removal of anterior chamber angle foreign body(ACFB) using a prism contact lens and 23-gauge foreign body forceps.METHODS:Data of 42 eyes of 42 patients who had undergone remov... AIM:To introduce a novel approach in removal of anterior chamber angle foreign body(ACFB) using a prism contact lens and 23-gauge foreign body forceps.METHODS:Data of 42 eyes of 42 patients who had undergone removal of ACFB using a prism contact lens and 23-gauge foreign body forceps from January 2008 to October 2013 were collected and analyzed. Twenty eyes in group A received the conventional approach by using toothed forceps through corneal limbus incision, and 22 eyes in group B underwent the novel method through the opposite corneal limbus incision. RESULTS:The success rate of ACFB once removal was 75%(15/20) in group A, and 100%(22/22) in group B. The average operation time of group A was significantly longer compared with group B(34.9±9.88 min vs 22.13±8.85min; P〈0.05). The average size of corneal limbus incision in group A was significantly larger than that of group B(4.85±1.89 mm vs 3.95±1.17 mm; P〈0.05). The corneal limbus incision suturing were conducted in all eyes in group A, and only 5 eyes in group B. CONCLUSION:Removal of ACFB using a prism contact lens and 23-gauge foreign body forceps is a safer, more effective, and convenient technique compared with the conventional approach. 展开更多
关键词 prism contact lens intraocular foreign body anterior chamber angle 23-gauge foreign body forceps
下载PDF
Evaluation of the Anterior Chamber Angle Structures in Perinatal Infants Using a Wide-Field Digital Fundus Camera
7
作者 Xian ZHANG Dan-lan LUO +2 位作者 Bo CHEN Qiong-lei ZHONG Hong YANG 《Current Medical Science》 SCIE CAS 2022年第6期1305-1309,共5页
Objective This study aimed to evaluate the ability of a digital fundus camera to observe the development of the anterior chamber angle(ACA)in premature infants.Methods Forty-eight eyes of preterm infants(n=48)were exa... Objective This study aimed to evaluate the ability of a digital fundus camera to observe the development of the anterior chamber angle(ACA)in premature infants.Methods Forty-eight eyes of preterm infants(n=48)were examined by a digital fundus camera to observe the development of the ACA.ACA grading was performed based on the visualization of the anterior chamber structures according to the Scheie Angle Depth Evaluating System.Results ACA images from all 48 infants were successfully acquired using RetCam3.The corrected gestational age ranged from 30 weeks to 49 weeks,which covered the period from 2 months preterm to>2 months post-term.As the corrected gestational age increased,the corrected gestational age grading was significantly decreased.The mean corrected gestational ages of the infants corresponding to the ACA classification from grade IV to grade 0 were 32.75±1.89,37.20±1.30,39.75±2.38,40.56±2.24,and 44.23±2.14 weeks,respectively,which were all significantly different(P<0.05).The regression analysis showed a linear correlation between the grading of the ACA and the corrected gestational age(R2=0.724,P=0.0001).Conclusion The ACA of a full-term newborn can be fully detected and evaluated by a digital fundus camera.For premature infants,part of the ACA is not visible physiologically;however,it should not be misdiagnosed as angle closure or a narrow angle. 展开更多
关键词 digital fundus camera anterior chamber angle GLAUCOMA INFANT
下载PDF
Post-miosis changes in the anterior chamber structures in primary and lens-induced secondary chronic angle-closure glaucoma 被引量:2
8
作者 Mu Li Xiao-Qin Yan +1 位作者 Gai-Yun Li Hong Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第4期675-680,共6页
To evaluate post-miosis changes in the anterior chamber structures in various angle-closure glaucomas(ACG). Totally 14 eyes of primary chronic angle-closure glaucoma(PCACG), 12 eyes of lens-induced secondary chronic a... To evaluate post-miosis changes in the anterior chamber structures in various angle-closure glaucomas(ACG). Totally 14 eyes of primary chronic angle-closure glaucoma(PCACG), 12 eyes of lens-induced secondary chronic angleclosure glaucoma(LSACG) and 14 healthy eyes were recruited. After miosis, for PCACG group, intraocular pressure(IOP) and anterior chamber depth(ACD) changed not significantly, while anterior chamber angle widened significantly. LSACG group showed a significant increase in IOP, decrease in ACD, and narrowing in anterior chamber angle. Healthy eyes showed significant decreases in IOP and anterior chamber parameters. Thus, miosis could widen the anterior chamber angle of patients with PCACG, while increase the narrowing of anterior chamber angle and IOP of patients with LSACG. We should pay attention to the distinction between PCACG and LSACG patients and the proper administration of pilocarpine in the treatment of patients with chronic ACG. 展开更多
关键词 MIOSIS chronic angle-CLOSURE GLAUCOMA anterior chamber structure INTRAOCULAR pressure optical coherence tomography
下载PDF
Efficacy of Combined Phacoemulsification and Goniosynechialysis in the Treatment of Patients with Primary Angle Closure Disease and Concomitant Cataract at Preah Ang Duong Hospital in Cambodia
9
作者 Channdarith Kith Piseth Kong +6 位作者 Kossama Chukmol Bunseng Sea Seiha Do Meng Ngy Amarin Mar Ratneary Hav Saly Saint 《Open Journal of Ophthalmology》 2024年第3期284-312,共29页
Background: Goniosynechialysis is a surgical procedure that has been shown to slow the progression of glaucoma in oriental eyes with chronic angle closure glaucoma. This procedure was successful in 80% of cases, and t... Background: Goniosynechialysis is a surgical procedure that has been shown to slow the progression of glaucoma in oriental eyes with chronic angle closure glaucoma. This procedure was successful in 80% of cases, and the peripheral anterior syenchiae did not exist until one year later. Nonetheless, there is little evidence of its efficacy in our context. Our study aims to investigate the efficacy of goniosynechialysis during phacoemulsification in patients with primary angle closure disease and concomitant cataract. Methods: This was an observational, prospective study. The intra-ocular pressure, need for anti-glaucoma drugs, visual acuity, the extent of synechiae, anterior chamber depth, surgical success rate, and other indicators were monitored for at least three months following surgery. Results: This study included 114 patients (118 eyes), 61 with chronic angle closure glaucoma (51.69%), 33 with primary angle closure (27.97%), and 24 with acute attack angle closure (20.34%), who were surgically treated with phacoemulsification and goniosynechialysis (Phaco-GSL). The mean intra-ocular pressure had significantly decreased three months after surgery (pre- vs post-op: 22.04 ± 10.86 vs 15.41 ± 6.06 mmHg, p-value p-value p-value p-value p-value Conclusion: Regardless of the type of glaucoma, combined phacoemulsification-goniosynechialysis is effective in lowering pressure, restoring vision, reducing the need for anti-glaucoma drugs, and preventing the synechial recurrence. Success was higher in eyes with less extensive synechiae. Phaco-GSL is safe and effective in the treatment of primary angle closure diseases with co-existing cataract. 展开更多
关键词 EFFICACY PHACOEMULSIFICATION GONIOSYNECHIALYSIS Primary angle-Closure Disease Chronic angle-Closure Glaucoma GONIOSCOPY Intra-Ocular Pressure Peripheral anterior Synechiae Anti-Glaucoma Drugs anterior chamber Depth
下载PDF
Axial length,vitreoretinal pathology,and anterior chamber depth can predict postoperative refractive outcomes in phacovitrectomy/silicone oil removal 被引量:2
10
作者 Xu Chen He Zhao +6 位作者 Jia-Yun Ren Lu Wang Jun-Li Wan Bo Liu Nan Wu Xi Liu Yong Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期554-562,共9页
AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.M... AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice. 展开更多
关键词 axial length vitreoretinal pathology anterior chamber depth intraocular lens pars plana vitrectomy silicone oil removal CATARACT combined surgery refractive error intraocular tamponade
下载PDF
Axial length and anterior chamber indices in elderly population: Tehran Geriatric Eye Study 被引量:1
11
作者 Hassan Hashemi Samira Heydarian +1 位作者 Alireza Hashemi Mehdi Khabazkhoob 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1876-1882,共7页
AIM:To determine the normative distribution of axial length(AL),anterior chamber depth(ACD),anterior chamber volume(ACV),anterior chamber angle(ACA),and some of their associated factors in subjects aged 60 and over.ME... AIM:To determine the normative distribution of axial length(AL),anterior chamber depth(ACD),anterior chamber volume(ACV),anterior chamber angle(ACA),and some of their associated factors in subjects aged 60 and over.METHODS:In this cross-sectional study,160 clusters were sampled using multi-stage cluster sampling in Tehran,Iran.After a preliminary interview,the participants underwent optometric examinations including visual acuity and refraction measurement followed by slit lamp biomicroscopy.Finally,ocular imaging was done using the Pentacam AXL to measure AL,ACD,ACV,and ACA.RESULTS:A total of 4519 eyes of 2436 participants were evaluated,of whom 58.0%(n=1412)were female.The mean age of the subjects was 67.32±6.05y(range:60-95y).The mean AL,ACD,ACV,and ACA was 23.22 mm(23.18-23.27 mm),2.61 mm(2.59-2.62 mm),126.56 mm3(125.08-128.04 mm3),and 30.61°(30.3°-30.92°),respectively.In the multivariable model,after adjusting for the effect of both eyes,the longest and shortest AL was seen in myopic and hyperopic subjects,respectively.AL,ACD,ACV and ACA were significantly larger in men compared to women(P<0.001).Except ACA,other evaluated parameters showed an inverse correlation with age(P<0.001),however,this correlation was insignificant for AL(P=0.623).CONCLUSION:Normative value of AL,and other biometric parameters are specific for each ethnicity,age and sex group.Any alteration in these parameters and their effect on refraction should be considered in this age group,especially in case of cataract surgery. 展开更多
关键词 BIOMETRY ELDERLY axial length anterior chamber depth
下载PDF
Measurement of the depths at different regions of the anterior chamber in healthy Chinese adults 被引量:1
12
作者 Yuan Zong Qing-Chen Li +3 位作者 Huan Xu Jian Yu Chun-Hui Jiang Xing-Huai Sun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第1期135-140,共6页
AIM: To measure the depths of different regions of the anterior chamber(AC) in healthy Chinese adults, and to explore possible correlations with age or gender.METHODS: The AC was imaged by swept-source optical coheren... AIM: To measure the depths of different regions of the anterior chamber(AC) in healthy Chinese adults, and to explore possible correlations with age or gender.METHODS: The AC was imaged by swept-source optical coherence tomography in healthy Chinese adults. The horizontal scan of the right eye was used to measure the anterior chamber depth(ACD) at 199 points.RESULTS: A total of 309 images from 309 subjects were analyzed. The ACD values at nearly all locations were negatively correlated with age(all P<0.05), except for ACD1, 2, 198, and 199(correspond to the iris roots). The mean annual decrease 0.013±0.005 mm/y for all ACDs combined, 0.008±0.004 mm/y for the peripheral region, 0.017±0.003 mm/y for the middle peripheral region, and 0.014±0.001 mm/y for the central region. The mean annual decrease was significantly different among these three regions(P<0.001). The ACD was greater in males than in females(P<0.05). The mean difference in ACD between males and females was 0.081±0.025 mm.CONCLUSION: This study showed that optical coherence tomography can be used to measure the ACD of different regions of the AC. We found reductions in ACD with age, although the reduction varied among different points, in healthy Chinese adults. 展开更多
关键词 optical coherence tomography anterior chamber depth age GENDER anterior chamber
下载PDF
Risk factors for flat anterior chamber after glaucoma filtration surgery 被引量:4
13
作者 Xiang-Ji Zi Richard Filek +5 位作者 Xiang-Ge He Wei Wang Hong Liu Lian He Yu-Rong Tang Lin Xie 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第8期1322-1329,共8页
AIM: To investigate the incidence rate and risk factors for grade Ⅲ flat anterior chamber(FAC) after glaucoma filtration surgery based on 5-year data.METHODS: Patients who underwent glaucoma filtration surgery in... AIM: To investigate the incidence rate and risk factors for grade Ⅲ flat anterior chamber(FAC) after glaucoma filtration surgery based on 5-year data.METHODS: Patients who underwent glaucoma filtration surgery in Daping hospital from January 2009 to December 2013 were enrolled in this retrospective study. The incidence of grade Ⅲ FAC following glaucoma filtration surgery was determined. Regression analysis was performed to investigate the influence of glaucoma type, surgical approach, age, and preoperative intraocular pressure(IOP) on the risk of postoperative FAC.RESULTS: A total of 2179 eyes receiving anti-glaucoma surgery were included. Ninety-one eyes suffered from postoperative FAC, with an overall incidence rate of 4.18%. Of 471 eyes with primary open angle glaucoma(POAG), grade Ⅲ FAC occurred in only 3 eyes(0.64%). Primary angleclosure glaucoma(PACG) was diagnosed in 1076 eyes, 39(3.62%) of which developed grade Ⅲ FAC, including 12 eyes(12/300, 4%) with acute PACG(aP ACG) and 27 eyes(27/776, 3.48%) with chronic PACG(c PACG). Six of 259 eyes(2.32%) with secondary glaucoma, 28 of 186 eyes(15.05%) with neovasular glaucoma, 1 of 66 eyes(1.52%) with congenital glaucoma, and 14 of 115 eyes(12.17%) with remnant glaucoma suffered from grade Ⅲ FAC. Of 6 eyes with mixed glaucoma, none developed grade Ⅲ FAC after surgery. When stratified by surgical approach, 24 of 766 eyes(3.13%) undergoing trabeculectomy, 21 of 924 eyes(2.27%) treated by trabeculectomy plus mitomycin C(MMC), 18 of 109 eyes(16.51%) undergoing Ahmed glaucoma valve implantation, 23 of 201 eyes(11.44%) managed by Ahmed implantation plus MMC, and 5 of 133 eyes(3.76%) treated by Ahmed implantation plus lens extraction or vitrectomy developed grade Ⅲ FAC. Logistic regression analysis revealed that factors including neovasular glaucoma, remnant glaucoma, glaucoma valve implantation, glaucoma valve implantation+MMC, glaucoma valve implantation+vitrectomy, age〉60 y, and IOP at admission 〉50 mm Hg were significantly associated with an increased risk for grade Ⅲ FAC.CONCLUSION: The overall incidence of grade Ⅲ FAC after glaucoma filtration surgery is 4.18%. Patients with neovasular glaucoma and remnant glaucoma are at a higher risk of developing FAC. Ahmed glaucoma valve implantation is associated with a higher risk for grade Ⅲ FAC compared with trabeculectomy. No significant correlation was observed between the use of MMC in glaucoma filtration surgery and the risk of postoperative FAC. Higher IOP at admission(〉50 mm Hg) and old age(〉60 y) are risk factors for grade Ⅲ FAC. 展开更多
关键词 GLAUCOMA filtration surgery grade IIIflat anterior chamber TRABECULECTOMY glaucoma valveimplantation mitomycin C
下载PDF
Anterior segment changes after pharmacologic mydriasis using Pentacam and optical coherence tomography in angle closure suspects 被引量:4
14
作者 Jing-Min Guo Mu Li +2 位作者 Xiao-Lan Xu Hong Zhang Jun-Ming Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第5期980-984,共5页
AIM: To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls. METHODS: The study group comprised 1... AIM: To compare the dynamic changes of anterior segment parameters especially iris morphology induced by pharmacologic mydriasis between angle closure suspects and normal controls. METHODS: The study group comprised 19 eyes of 19 angle closure suspects and 19 eyes of 19 age- and sexmatched normal open-angle eyes. Pentacam and optical coherence tomography measurements before and 30min after instillation of compound tropicamide eye drop were performed and compared. Biometric evaluations of iris tomography and anterior chamber angle were estimated by a customized image-processing software. RESULTS: Baseline axial length, iris cross sectional area and volume did not differ significantly between angle closure suspects and normal controls. Angle closure suspects had smaller pupil size, narrower anterior segment dimension and axial length, thinner iris with greater curve in comparison with normal controls. Pharmacologic mydriasis led to significant increments in iris thickness at 750 mu m, anterior chamber depth and volume, whereas significant decrements in iris curve, cross sectional area and volume in both groups. Angle opening distance at 500 mu M was increased significantly in normal controls (from 0.465 +/- 0.115 mm to 0.539 +/- 0.167 mm, P=0.009), but not in angle closure suspects (from 0.125 0.100 mm to 0.145 +/- 0.131 mm, P=0.326). Iris volume change per millimeter of pupil dilation (Delta IV/Delta PD) decreased significantly less in angle closure suspects than normal controls (-2.47 +/- 1.33 mm(2) vs -3.63 +/- 1.58 mm(2), P=0.019). Linear regression analysis showed that the change of angle opening distance at 500 mu M was associated most with the change of central anterior chamber depth (beta= 0.841, P=0.002) and Delta IV/Delta PD (beta=0.028, P=0.002), followed by gender (beta=0. 062, P=0.032). CONCLUSION: Smaller iris volume decrement per millimeter of pupil dilation is related significantly with the less anterior angle opening in angle closure suspects after pharmacologic mydriasis. Dynamic iris change may be as a prospective indicator of iris compressibility and angle closure glaucoma. 展开更多
关键词 pharmacologic mydriasis primary angle closure suspects anterior segment change iris volume
下载PDF
Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review 被引量:13
15
作者 Alberto Domínguez-Vicent Cari Pérez-Vives +2 位作者 Teresa Ferrer-Blasco Santiago García-Lázaro Robert Montés-Micó 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第7期1057-1065,共9页
We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies r... We have reviewed a set of recently published studies that compared the anterior chamber depth(ACD) and/or white-to-white(WTW) distance obtained by means of different measuring devices.Since some of those studies reached contradictory conclusions regarding device interchangeability,this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance,among these devices:A-scan,ultrasound biomicroscopy,Orbscan and Orbscan Ⅱ(Bausch&Lomb Surgical Inc.,San Dimas,California,USA),Pentacam and Pentacam HR(Oculus,Wetzlar,Germany),Galilei(Ziemer,Switzerland),Visante optical coherence tomography(Visante OCT,Carl Zeiss Meditec Inc.,Dublin,California,USA),lOLMaster(Carl Zeiss Meditec,Jena,Germany),and Lenstar LS 900/Biograph(Haag-Streit AG,Koeniz,Switzerland/Alcon Laboratories Inc.,Ft Worth,Texas,USA). 展开更多
关键词 anterior camber depth measurement white to white measurement device interchangeability anterior chamber eye
下载PDF
Effect of axial length and anterior chamber depth on the peripheral refraction profile 被引量:2
16
作者 Masoud Khorrami-Nejad Raha Moradi +1 位作者 Alireza Akbarzadeh Baghban Bahram Khosravi 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第2期292-298,共7页
AIM:To evaluate the effect of axial length(AL)and anterior chamber depth(ACD)on peripheral refractive profile in myopic patients compared to emmetropic participants.METHODS:This cross-sectional study was conducted in ... AIM:To evaluate the effect of axial length(AL)and anterior chamber depth(ACD)on peripheral refractive profile in myopic patients compared to emmetropic participants.METHODS:This cross-sectional study was conducted in right eyes of 58 participants of whom 38 were emmetropic and 20 were myopic.Central and peripheral refraction were measured at 10°,20°,and 30°eccentricities in nasal and temporal fields using an open-field autorefractor.The Lenstar LS900 was used to measure ACD and AL.The participants were divided into three groups of short(<22.5 mm),normal(22.5-24.5 mm),and long eye(>24.5 mm)according to AL and three groups of low ACD(<3.00 mm),normal ACD(3.00-3.60 mm),and high ACD(>3.60 mm)according to ACD.RESULTS:The mean age of the participants was 22.26±3.09 y(range 18-30 y).The peripheral mean spherical refractive error showed a hypermetropic shift in myopic and emmetropic groups although this shift was more pronounced in the myopic group.The results showed significant changes in the spherical equivalent,J0,and J45 astigmatism in all gazes with an increase in eccentricity(P<0.001).The pattern of refractive error changes was more noticeable in long and short eyes versus normal AL eyes.Moreover,the pattern of peripheral refractive changes was much more prominent in the high ACD group versus the normal ACD group and in the normal ACD group versus the low ACD group.CONCLUSION:Peripheral refraction changes are greater in participants with AL values outside the normal range and deeper ACD values compared to participants with normal AL and ACD. 展开更多
关键词 anterior chamber depth axial length peripheral refraction
下载PDF
Corrections in alpha angle following two different operative approaches for CAM-type femoral acetabular impingement-Ganz surgical hip dislocation vs anterior mini-open 被引量:1
17
作者 Emanuel C Haug Wendy M Novicoff Quanjun Cui 《World Journal of Orthopedics》 2020年第1期27-35,共9页
BACKGROUND Femoroacetabular impingement(FAI)is a predisposing factor for secondary osteoarthritis of the hip joint.The two extensively described impingement mechanisms of FAI are CAM and Pincer-type.Initially managed ... BACKGROUND Femoroacetabular impingement(FAI)is a predisposing factor for secondary osteoarthritis of the hip joint.The two extensively described impingement mechanisms of FAI are CAM and Pincer-type.Initially managed conservatively,operative intervention should be offered to the persistently symptomatic patient.The measurement of the alpha angle is considered a standard method of assessing the severity of pathology in Cam-type FAI on pre-operative plain radiographs.The radiological correction of the alpha angle has not been previously compared between different surgical approaches.We hypothesize that there is no difference in alpha angle correction between Ganz surgical hip dislocation and the anterior mini-open approach.AIM To compare the magnitude of alpha angle correction achieved by using the Ganz surgical hip dislocation and the anterior mini-open approach.METHODS This is a retrospective study assessing seventy-nine patients identified in a 5-year period.These patients had preoperative radiographic evidence of FAI and underwent surgery by a single surgeon at our institution,a tertiary care center.Patients with missing radiographic documentation,radiographs with insufficient quality which then precluded accurate measurement of the angleα,a diagnosed congenital condition,isolated type II pathology(Pincer),and history of prior surgery were excluded from the study.Either the Ganz surgical hip dislocation or the anterior mini open approach was used.Postoperative radiographic evaluation of the alpha angle between the two surgical methods was done and corrected for age and gender using two-sample t-tests and Chi-square analyses.RESULTS A total of 79 patients met the inclusion and exclusion criteria.Forty-seven males(mean age of 35.3,range 16-53)and 32 females(mean age 36.7,range 16-60)were enrolled.Forty-seven patients underwent the anterior mini-open approach,and 32 underwent the Ganz surgical hip dislocation.There were no significant differences in age between the two surgical groups or in pre-and post-operative alpha angles based on patient gender.The mean pre-operative alpha angle for the Ganz surgical hip dislocation group was 88.0 degrees(SD 12.3)and 99.4 degrees(SD 7.2)for the anterior mini-open group.Mean post-operative angles were 49.9 degrees(SD 4.3)for the Ganz surgical hip dislocation and 43.8(SD 4.3)degrees for the anterior mini-open group.There was a statistically significant difference in patient’s pre-operative and post-operative angles(P=0.000)with both surgical approaches.CONCLUSION Statistically significant decreases in alpha angle were noted for both surgical techniques,with larger decreases seen in the anterior mini-open group. 展开更多
关键词 Alpha angle Femoroacetabular impingement Ganz surgical hip dislocation anterior mini-open
下载PDF
Incidence and predisposing factors of anterior chamber gas bubbles during femtosecond laser flap creation 被引量:1
18
作者 Muanploy Niparugs Sumet Supalaset +3 位作者 Chulaluck Tangmonkongvoragul Napaporn Tananuvat Winai Chaidaroon Somsanguan Ausayakhun 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第8期1334-1337,共4页
AIM:To investigate the incidence and the predisposing factors of anterior chamber(AC)gas bubbles during femtosecond laser(FS)flap creation for laser in situ keratomileusis(LASIK).METHODS:All patients who underwent FS-... AIM:To investigate the incidence and the predisposing factors of anterior chamber(AC)gas bubbles during femtosecond laser(FS)flap creation for laser in situ keratomileusis(LASIK).METHODS:All patients who underwent FS-LASIK surgery at CMU LASIK Center between January 2013 and May 2016 were retrospective reviewed.Preoperative and intraoperative data including keratometry,white-towhite(WTW)corneal diameter,flap parameters(diameter,thickness,hinge position,and tunnel length)and pulse energy were reviewed and compared between incident group and control group.To determine the risk factors,univariate and multivariate conditional logistic regression were used;the eye was unit of analysis.RESULTS:The incidence of AC gas bubbles was 1.6%(22 out of 1378 eyes).The median WTW in the AC bubbles group was 11.5 mm(range 11.1-12.1),which was significantly different from the control group(11.7 mm,range 10.5-12.8,P=0.021).The result of the median WTW minus the flap diameter in the AC bubbles group was 2.5 mm(range 2.1-3.2),which was statistically different to the control group(2.7 mm,range 1.5-3.8,P=0.008).The logistic regression analysis showed that the result of the WTW minus the flap diameter in the AC bubbles group had an adjusted odds ratio of 0.204(95%CI;0.056-0.747,P=0.016).CONCLUSION:Development of AC gas bubbles during FS flap creation is not an uncommon event in Asian eyes which typically have a small WTW.The flap diameter when adjusted relatively to the WTW is a predisposing factor to the possibility of AC gas bubbles occurrence. 展开更多
关键词 anterior chamber gas bubble LASIK femtosecond laser
下载PDF
Comparison between Ophthalmologists and Community Health Workers in Screening of Shallow Anterior Chamber with Oblique Flashlight Test 被引量:1
19
作者 Yusoh Nuriyah Xue-tao Ren +2 位作者 Li Jiang Xi-pu Liu Yan-hong Zou 《Chinese Medical Sciences Journal》 CAS CSCD 2010年第1期50-52,共3页
Objective To study the agreement between ophthalmologists and community health workers in detecting shallow anterior chamber with oblique flashlight test. Methods Totally 425 subjects were given an eye examination in ... Objective To study the agreement between ophthalmologists and community health workers in detecting shallow anterior chamber with oblique flashlight test. Methods Totally 425 subjects were given an eye examination in a community health center. The anterior chamber depth of each subject was examined by one ophthalmologist and two trained community health workers (one nurse and one non-professional health worker) using oblique flashlight test. Inter-observer agreement was determined using the weighted kappa statistic. Results Among the enrolled subjects,148 (35%) were male and 277 (65%) were female. Good agreement was noted in all the three observers. The comparison between the ophthalmologist and the nurse showed a kappa statistic of 0.42 for both eyes (P<0.001). The kappa statistic was 0.54 and 0.52 for right and left eyes respectively between the ophthalmologist and the non-professional health worker (P<0.001). As for agreement between the nurse and the non-professional health worker,the kappa statistic was 0.49 and 0.38 for right and left eyes,respectively (P<0.001). Conclusion The oblique flashlight test may be used as an applicable tool by trained community health workers for screening of shallow anterior chamber and play a role in blindness prevention in community. 展开更多
关键词 GLAUCOMA shallow anterior chamber oblique flashlight test
下载PDF
Distribution of Axial Length, Anterior Chamber Depth and Lens Thickness of Pre-Operative Cataract Patients in Indonesian Population 被引量:1
20
作者 Titiek Ernawati Maharani Kartika Anggraeni +1 位作者 Kevin Anggakusuma Hendrawan Rianti Wulandari Pratiwi 《Open Journal of Ophthalmology》 2020年第4期288-296,共9页
<strong>Purpose:</strong> Biometry measurement of pre-operative cataract patients plays<span "=""> a major role in calculating intraocular lens power. This study aimed to review and de... <strong>Purpose:</strong> Biometry measurement of pre-operative cataract patients plays<span "=""> a major role in calculating intraocular lens power. This study aimed to review and determine the distribution of biometry components, such as axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) of pre-operative cataract patient in Indonesian population. <b>Methods: </b>A cross-sectional study data w</span>ere obtained from 2015-2018 cataract surgery at Prima Husada Citra Hospital, Surabaya, East Java, Indonesia. A total of 1295 eyes with cataract was included in the study based on their medical record. We analyzed the data using descriptive analysis and correlated<span "=""> each variable using the Spearman’s Rho analysis. <b>Results: </b>Mean AL, LT and ACD was 23.81 </span>± 1.46 mm, 4.49 ± 0.55 mm, 3.25 ±<span "=""> 0.70 mm respectively. Male has longer AL and deeper ACD with (<i>p</i> < 0.001), while LT was found thicker in female (<i>p</i></span><span "=""> </span>=<span "=""> </span><span "="">0.005). The increase of AL was accompanied by ACD (<i>r</i> = 0.457;<i>p</i> < 0.001) and a thinner LT (<i>r </i>= </span><span "=""><span style="color:#4F4F4F;">&#45;</span>0.101;<i>p</i> < 0.001). <b>Conclusions: </b>LT is increased with age while AL and ACD are shortened with age. There was a positive correlation between AL and ACD, but a</span>n inverse correlation between AL and LT. 展开更多
关键词 anterior chamber Depth Axial Length CATARACT Lens Thickness
下载PDF
上一页 1 2 90 下一页 到第
使用帮助 返回顶部