This paper researches on some key technologies of anti-jamming of an air-borne radar receiver, the automatic testing of AGC, IAGC and multi-filtering under one million noisy pulses by the computer simulation system. T...This paper researches on some key technologies of anti-jamming of an air-borne radar receiver, the automatic testing of AGC, IAGC and multi-filtering under one million noisy pulses by the computer simulation system. The system tests the width of the jamming pulse whose width is 100% bigger, 60% bigger and 100% smaller than the Radar signal’s respectively and show the SNR curve.展开更多
直流系统是支撑高比例新能源接入与灵活高效用能的重要技术方向。固态式直流断路器(solid state DC circuit breaker,SSCB)具有开断速度极快、无电弧、寿命长等优点,在中低压直流系统的故障保护中得到广泛应用。随着电力电子器件的发展...直流系统是支撑高比例新能源接入与灵活高效用能的重要技术方向。固态式直流断路器(solid state DC circuit breaker,SSCB)具有开断速度极快、无电弧、寿命长等优点,在中低压直流系统的故障保护中得到广泛应用。随着电力电子器件的发展,固态式直流断路器的拓扑结构、工作性能也在不断进步。为此基于逆阻型集成门极换流晶闸管(intergated gate commutate thyristor,IGCT),提出了一种新型的固态式直流断路器结构及设计方法,通流支路采用逆阻IGCT反并联结构实现双向通流,缓冲支路采用金属氧化物避雷器(metal oxide varistor,MOV)-电容结构来抑制过电压,吸能支路采用MOV吸收系统能量。进一步地,给出了关键元器件的参数设计方法,并验证了有效性;设计了性能良好的重力热管散热器,单个模块散热功率可达700 W;提出了主被动结合的控保策略,提高断路器的保护性能。最后,研制了固态式直流断路器样机,可用于750 V以内的低压直流系统,额定通流可达2 kA,可在百微秒内开断10 kA故障电流,成本低、体积小、高可靠,具有良好的应用前景。展开更多
目的评价药师干预口服抗肿瘤药物患者用药依从性的成效。方法采用计算机检索PubMed,Web of Science,Embase及中国知网、维普和万方医学数据库中药师对口服抗肿瘤药物患者用药依从性进行干预的相关研究,检索时限为自建库起至2022年4月1...目的评价药师干预口服抗肿瘤药物患者用药依从性的成效。方法采用计算机检索PubMed,Web of Science,Embase及中国知网、维普和万方医学数据库中药师对口服抗肿瘤药物患者用药依从性进行干预的相关研究,检索时限为自建库起至2022年4月1日。采用Cochrane偏倚风险评价工具RoB2进行偏倚风险评价,采用RevMan 5.4软件进行Meta分析,无法进行Meta分析的结局指标进行描述性统计。结果共纳入8项随机对照试验(RCT),涉及患者717例。常见的用药依从性干预措施为定期随访、用药教育和咨询。测量方法包括直接评估法和间接评估法,其中直接评估法通过测量血药浓度;间接评估法包括客观评估法(药片计数法和电子监测设备)和主观评估法(患者问卷调查)。4项以患者是否依从用药二分类变量为结局指标的RCT的Meta分析结果显示,药师对口服抗肿瘤药物患者进行药学干预可显著提高其用药依从性[OR=4.59,95%CI(1.09,19.29),P=0.04];亚组分析结果显示,采用主观评估法评估用药依从性的研究中,干预组的用药依从性显著提高[OR=6.84,95%CI(2.84,16.50),P<0.0001]。结论药师积极对口服抗肿瘤药物患者进行药学干预,可提高患者的用药依从性。展开更多
文摘This paper researches on some key technologies of anti-jamming of an air-borne radar receiver, the automatic testing of AGC, IAGC and multi-filtering under one million noisy pulses by the computer simulation system. The system tests the width of the jamming pulse whose width is 100% bigger, 60% bigger and 100% smaller than the Radar signal’s respectively and show the SNR curve.
文摘目的评价药师干预口服抗肿瘤药物患者用药依从性的成效。方法采用计算机检索PubMed,Web of Science,Embase及中国知网、维普和万方医学数据库中药师对口服抗肿瘤药物患者用药依从性进行干预的相关研究,检索时限为自建库起至2022年4月1日。采用Cochrane偏倚风险评价工具RoB2进行偏倚风险评价,采用RevMan 5.4软件进行Meta分析,无法进行Meta分析的结局指标进行描述性统计。结果共纳入8项随机对照试验(RCT),涉及患者717例。常见的用药依从性干预措施为定期随访、用药教育和咨询。测量方法包括直接评估法和间接评估法,其中直接评估法通过测量血药浓度;间接评估法包括客观评估法(药片计数法和电子监测设备)和主观评估法(患者问卷调查)。4项以患者是否依从用药二分类变量为结局指标的RCT的Meta分析结果显示,药师对口服抗肿瘤药物患者进行药学干预可显著提高其用药依从性[OR=4.59,95%CI(1.09,19.29),P=0.04];亚组分析结果显示,采用主观评估法评估用药依从性的研究中,干预组的用药依从性显著提高[OR=6.84,95%CI(2.84,16.50),P<0.0001]。结论药师积极对口服抗肿瘤药物患者进行药学干预,可提高患者的用药依从性。