This study investigates the removal of silica and alumina as impurities from hematite based low-grade iron ore containing 34.18 mass% iron, 31.10 mass% of silica and 7.65 mass% alumina. Wet high-intensity magnetic sep...This study investigates the removal of silica and alumina as impurities from hematite based low-grade iron ore containing 34.18 mass% iron, 31.10 mass% of silica and 7.65 mass% alumina. Wet high-intensity magnetic separation (WHIMS) and reverse flotation (RF) were investigated. In WHIMS process, 93.08% of iron was recovered with a grade of 53.22 mass% at an optimum magnetic density of 10,000 mT, and pulp density of 2% used the L-4 machine. In RF experiments, optimal results showed 95.95% of iron recovered with 51.64 mass% grade using 1 kg/t of 1% alkaline starch as iron depressant and 1:1 mixture ratio of 0.75 kg/t DAA and NaOL as silica and alumina collectors. The designed multi-stage process involving feeding the concentrate from WHIMS into RF process reduced silica to 2.02 mass%, alumina to 1.04 mass% whilst recovering 81.94% of the iron with 67.27 mass% grade. As a result of this research, a process to produce high quality iron concentrate from hematite based low-grade iron ore with high iron recovery rate was constructed.展开更多
The compositions of Pb and Zn mixed rougher concentrates were studied. The process utilizes flotation and gravity flow sheet to separate Pb or Zn. Pb and Zn in the tailings were reclaimed by gravity more efficiently. ...The compositions of Pb and Zn mixed rougher concentrates were studied. The process utilizes flotation and gravity flow sheet to separate Pb or Zn. Pb and Zn in the tailings were reclaimed by gravity more efficiently. This test used an ion-wave shaking table developed by Kunming University of Science and Technology. Based on the test results, the optimum test condition was chosen and testing of synthetic condition was performed. The results show that the process produces a final Zn concentrate with a 42.16% grade and 79.64% recovery and a final Pb concentrate with a 46.52% grade and 78.41% recovery.展开更多
The removal of microplastics(MPs)from water using oil has shown early promise;however,incorporation of this technique into a feasible in situ method has yet to be developed.Here,a simple yet effective method of MP cap...The removal of microplastics(MPs)from water using oil has shown early promise;however,incorporation of this technique into a feasible in situ method has yet to be developed.Here,a simple yet effective method of MP capture from water using vegetable oil with bubbles is demonstrated to achieve high removal efficiencies of>98%.Comparisons are made with other methods of agitation,and higher removal efficiencies are observed when bubbles are used.Due to the low agitation provided by the bubbles,the oil layer remains unbroken,meaning that no oil is released into the bulk water phase.In this way,secondary contamination is avoided—unlike membrane filtration,another effective removal method,in which polymer-based membranes can break down due to chemical backwashing and ageing.It is demonstrated that variation in MP size within the micrometer range(50–170 lm)has minor impact on the removal efficiency;however,100%removal is achieved for larger,millimeter-sized MPs(500–5000 lm).Similarly,a high removal efficiency of greater than 99%is achieved in the capture of microfibers.Other factors such as oil volume and water salinity are also investigated and discussed.Based on these results,the proposed method can be introduced into multiple setting types as a passive and continuous method of MP capture.展开更多
文摘This study investigates the removal of silica and alumina as impurities from hematite based low-grade iron ore containing 34.18 mass% iron, 31.10 mass% of silica and 7.65 mass% alumina. Wet high-intensity magnetic separation (WHIMS) and reverse flotation (RF) were investigated. In WHIMS process, 93.08% of iron was recovered with a grade of 53.22 mass% at an optimum magnetic density of 10,000 mT, and pulp density of 2% used the L-4 machine. In RF experiments, optimal results showed 95.95% of iron recovered with 51.64 mass% grade using 1 kg/t of 1% alkaline starch as iron depressant and 1:1 mixture ratio of 0.75 kg/t DAA and NaOL as silica and alumina collectors. The designed multi-stage process involving feeding the concentrate from WHIMS into RF process reduced silica to 2.02 mass%, alumina to 1.04 mass% whilst recovering 81.94% of the iron with 67.27 mass% grade. As a result of this research, a process to produce high quality iron concentrate from hematite based low-grade iron ore with high iron recovery rate was constructed.
文摘The compositions of Pb and Zn mixed rougher concentrates were studied. The process utilizes flotation and gravity flow sheet to separate Pb or Zn. Pb and Zn in the tailings were reclaimed by gravity more efficiently. This test used an ion-wave shaking table developed by Kunming University of Science and Technology. Based on the test results, the optimum test condition was chosen and testing of synthetic condition was performed. The results show that the process produces a final Zn concentrate with a 42.16% grade and 79.64% recovery and a final Pb concentrate with a 46.52% grade and 78.41% recovery.
基金start-up financial support from the School of Engineering,Newcastle UniversityEngineering and Physical Sciences Research Council(EPSRC)for his Doctoral Training Partnership(DTP)studentship.
文摘The removal of microplastics(MPs)from water using oil has shown early promise;however,incorporation of this technique into a feasible in situ method has yet to be developed.Here,a simple yet effective method of MP capture from water using vegetable oil with bubbles is demonstrated to achieve high removal efficiencies of>98%.Comparisons are made with other methods of agitation,and higher removal efficiencies are observed when bubbles are used.Due to the low agitation provided by the bubbles,the oil layer remains unbroken,meaning that no oil is released into the bulk water phase.In this way,secondary contamination is avoided—unlike membrane filtration,another effective removal method,in which polymer-based membranes can break down due to chemical backwashing and ageing.It is demonstrated that variation in MP size within the micrometer range(50–170 lm)has minor impact on the removal efficiency;however,100%removal is achieved for larger,millimeter-sized MPs(500–5000 lm).Similarly,a high removal efficiency of greater than 99%is achieved in the capture of microfibers.Other factors such as oil volume and water salinity are also investigated and discussed.Based on these results,the proposed method can be introduced into multiple setting types as a passive and continuous method of MP capture.