期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Integrated Geoelectrical Resistivity Method for Environmental Assessment of Landfill Leachate Pollution and Aquifer Vulnerability Studies
1
作者 Stanley U. Eze Omafume M. Orji +2 位作者 Abriku E. Onoriode Saleh A. Saleh Macpaul O. Abolarin 《Journal of Geoscience and Environment Protection》 2022年第9期1-26,共26页
Leachate plumes from landfills are a major source of pollution in Nigeria, especially in urban areas. Assessing leachate contamination in the subsoil is considered a complex process that needs detailed field measureme... Leachate plumes from landfills are a major source of pollution in Nigeria, especially in urban areas. Assessing leachate contamination in the subsoil is considered a complex process that needs detailed field measurement to accurately define the extent of contamination. To ascertain the extent of pollution of the subsoil and groundwater sources which were reportedly contaminated by leachate plumes from an old dumpsite located in Osubi town, an integrated geo-electrical method involving 1-D vertical electrical sounding (VES) and 2-D, 3-D ERT techniques were employed. Orthogonal set of 2-D apparent resistivity data was collected in a 100 × 50 m<sup>2</sup> rectangular grid around the dumpsite, using the Wenner array. Two years later, three (3) 2-D resistivity imaging profiles were also recorded in time-lapse mode at the dumpsite to monitor the possible effects of attenuation on the leachate over time. Ten (10) VES data were also acquired and used along with the 2-D imaging data. 2-D apparent resistivity data were inverted with Dipprowin software program. The orthogonal set of 2-D lines of apparent resistivity was merged into 3-D data and inverted with RES3DINV program to create a 3-D subsurface resistivity model. Geological models observed from 2-D and 3-D resistivity inversion revealed low resistivity values in the order ρ Ω·m which is indicative of leachate plumes in the saturation zone (pore water). The 2-D resistivity-depth sections imaged low resistivity leachate plumes at the near surface (<5 m) to a depth of 25.0 m, while 3-D inversion depth slices imaged leachate contaminant within the first, second and third layers at depth ranging from 0.00 - 2.50 m, 2.50 - 5.38 m and 5.38 - 8.68 m respectively. Thus, leachate contamination clearly increased with depth beyond the depth of first and second aquifers in the area which implies that available groundwater for domestic use is already contaminated with leachate from the dumpsite. Leachate contaminant-depth map estimated for the second geoelectric layers for VES 2, 3, 4, 7, 8, 9, and 10 shows that the second layer has been invaded completely by leachate contamination up to 6.5 m depth. 2-D apparent resistivity data acquired two years after show lower resistivity anomalies of the leachate plume caused by time-lapse attenuation effect on the observed resistivity of the leachate. This indicates that the leachate plume has become more conductive and toxic to the environment. The Longitudinal conductance map of the area shows that the aquifer protective capacity of this area is weak (0.1 - 0.19 Mho) thus, aquifers in the area are prone to pollution from the dumpsite. The three techniques used in this study (2-D, 3-D ERT and 1-D VES) fitly provided crucial information on the degree of contamination caused by the landfill leachate plume. Therefore, it is advisable to implement an environmental remediation and leachate management program. 展开更多
关键词 Leachate Contamination Groundwater Pollution 2D and 3D Electrical Resistivity Tomography (ERT) aquifer vulnerability Environmental Assessment
下载PDF
Assessment of Groundwater Pollution Potential through GIS Technique: A Case Study for Pelly-Mianrudan Plain, Lali Urban District, Iran 被引量:1
2
作者 M. Chitsazan Z. Rahimi Y. Mirzaee 《Journal of Environmental Science and Engineering》 2011年第10期1350-1362,共13页
Considering the low average rainfall in the country and the importance of groundwater as a water supply source for drinking and agricultural water sections, water quality condition of groundwater must be controlled an... Considering the low average rainfall in the country and the importance of groundwater as a water supply source for drinking and agricultural water sections, water quality condition of groundwater must be controlled and prevented from any contamination. Identifying the vulnerable areas to pollution is one way of prevention. Many models have been offered for this purpose. In this study, a numerical rating scheme, called DRASTIC has been used for evaluating potential for groundwater pollution in pelly-mianrudan plain that is located in northern Lalli city in Khuzestan province. Resulted map obtained in GIS environment shows that the study area has DRASTIC index of 71-150 that is divided to five vulnerable zones namely no significance, very low, low, low to moderate, moderate to high. Maximum groundwater vulnerability correspondent low to medium zone that approximately covers 45 percentage of the study area and other parts on the northwest and center of the study area has high vulnerability. The sensitivity analysis showed that correlation DRASTIC index with net Recharge (0.68) and Impact of vadose zone media (0.63) parameters is more than other parameters in the study pelly-mianrudan area. The statistical analysis confirms that parameter soil media and topography are the most sensitive to contamination, followed in importance by parameters aquifer medium, vadose zone, recharge, hydraulic conductivity and depth to water. 展开更多
关键词 aquifer vulnerability DRASTIC model geographical information system pelly-mianrudan plain sensitivity analysis.
下载PDF