Fecal incontinence is an unresolved problem, which has a serious effect on patients, both physically and psychologically. For patients with severe symptoms, treatment with an artificial anal sphincter could be a poten...Fecal incontinence is an unresolved problem, which has a serious effect on patients, both physically and psychologically. For patients with severe symptoms, treatment with an artificial anal sphincter could be a potential option to restore continence. Currently, the Acticon Neosphincter is the only device certified by the US Food and Drug Administration. In this paper, the clinical safety and efficacy of the Acticon Neosphincter are evaluated and discussed. Furthermore, some other key studies on artificial anal sphincters are presented and summarized. In particular, this paper highlights that the crucial problem in this technology is to maintain long-term biomechanical compatibility be- tween implants and surrounding tissues. Compatibility is affected by changes in both the morphology and mechanical properties of the tissues surrounding the implants. A new approach for enhancing the long-term biomechanical compatibility of implantable artificial sphincters is proposed based on the use of smart materials.展开更多
This paper presents a set of analytical expressions used to determine the coupling coefficient between primary and secondary Litz-wire planar coils used in a transcutaneous energy transfer(TET) system. A TET system ha...This paper presents a set of analytical expressions used to determine the coupling coefficient between primary and secondary Litz-wire planar coils used in a transcutaneous energy transfer(TET) system. A TET system has been designed to power a novel elastic scaling artificial anal sphincter system(ES-AASS) for treating severe fecal incontinence(FI), a condition that would benefit from an optimized TET. Expressions that describe the geometrical dimension dependence of self- and mutual inductances of planar coils on a ferrite substrate are provided. The effects of ferrite substrate conductivity, relative permeability, and geometrical dimensions are also considered. To verify these expressions, mutual coupling between planar coils is computed by 3D finite element analysis(FEA), and the proposed expressions show good agreement with numerical results. Different types of planar coils are fabricated with or without ferrite substrate. Measured results for each of the cases are compared with theoretical predictions and FEA solutions. The theoretical results and FEA results are in good agreement with the experimental data.展开更多
基金supported by the Shanghai Pujiang Program(No.09PJ1406500)the National Natural Science Foundation of China(Nos.30970704,51075263,51121063,and 50821003)the Foundation from the State Key Laboratory of Mechanical Systems and Vibration(No.MSVZD201203),China
文摘Fecal incontinence is an unresolved problem, which has a serious effect on patients, both physically and psychologically. For patients with severe symptoms, treatment with an artificial anal sphincter could be a potential option to restore continence. Currently, the Acticon Neosphincter is the only device certified by the US Food and Drug Administration. In this paper, the clinical safety and efficacy of the Acticon Neosphincter are evaluated and discussed. Furthermore, some other key studies on artificial anal sphincters are presented and summarized. In particular, this paper highlights that the crucial problem in this technology is to maintain long-term biomechanical compatibility be- tween implants and surrounding tissues. Compatibility is affected by changes in both the morphology and mechanical properties of the tissues surrounding the implants. A new approach for enhancing the long-term biomechanical compatibility of implantable artificial sphincters is proposed based on the use of smart materials.
基金Project supported by the National Natural Science Foundation of China(No.31170968)
文摘This paper presents a set of analytical expressions used to determine the coupling coefficient between primary and secondary Litz-wire planar coils used in a transcutaneous energy transfer(TET) system. A TET system has been designed to power a novel elastic scaling artificial anal sphincter system(ES-AASS) for treating severe fecal incontinence(FI), a condition that would benefit from an optimized TET. Expressions that describe the geometrical dimension dependence of self- and mutual inductances of planar coils on a ferrite substrate are provided. The effects of ferrite substrate conductivity, relative permeability, and geometrical dimensions are also considered. To verify these expressions, mutual coupling between planar coils is computed by 3D finite element analysis(FEA), and the proposed expressions show good agreement with numerical results. Different types of planar coils are fabricated with or without ferrite substrate. Measured results for each of the cases are compared with theoretical predictions and FEA solutions. The theoretical results and FEA results are in good agreement with the experimental data.