期刊文献+
共找到10篇文章
< 1 >
每页显示 20 50 100
Case Report of a Pseudoaneurysm of Ascending Aorta Treated by Stent
1
作者 Mohammed Malik Bennani Mohamed Reda Barchiche Louis Chebli 《Open Journal of Clinical Diagnostics》 2023年第3期62-67,共6页
Pseudoaneurysms of the ascending aorta are a rare complication of aortic and cardiac surgery. In this article, we present a clinical case of a 56-year-old patient with a fortuitous diagnosis of a pseudoaneurysm of asc... Pseudoaneurysms of the ascending aorta are a rare complication of aortic and cardiac surgery. In this article, we present a clinical case of a 56-year-old patient with a fortuitous diagnosis of a pseudoaneurysm of ascending aorta that was treated by an endovascular stent-graft. We discuss in this article the diagnostic and therapeutic aspect of the case and the place of endovascular treatment for the ascending aorta. 展开更多
关键词 PSEUDOANEURYSM ascending aorta Bentley Stent-Graft Endovascular Treat
下载PDF
Left to Right Extracardial Shunt to Control Hemorrhage of Ascending Aorta and Left Ventricle: A Report of 3 Cases 被引量:4
2
作者 刘成硅 杨辰垣 +3 位作者 张凯伦 孙宗权 肖诗亮 蓝鸿钧 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1998年第3期177-179,共3页
Presented in this paper are 3 cases of hemorrhage of ascending aorta and left ventricle after open heart surgery treated by extracardial bypass in our hospital from Oct. 1994 to Dec. 1995. Remained aneurysmal wall enc... Presented in this paper are 3 cases of hemorrhage of ascending aorta and left ventricle after open heart surgery treated by extracardial bypass in our hospital from Oct. 1994 to Dec. 1995. Remained aneurysmal wall enclosing conduit graft was used as a sac bypassed to right atrium to form a extracardial left-toright shunt in order to control bleeding and the results turned out to be satisfactory. The bypass and hemodynamically ignorable shunt can close spontaneously without complications with recovery of coagulation system. The technique may find wide application in clinical practice. 展开更多
关键词 left-to-right extracardial shunt HEMORRHAGE ascending aorta left ventricle
下载PDF
Clinical Study of the Ascending Aorta Wall Motion by Velocity Vector Imaging in Patients with Primary Hypertension 被引量:2
3
作者 王蕾 王静 +4 位作者 谢明星 王新房 吕清 陈明 郑少萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2009年第1期127-130,共4页
We studied the wall motion characteristics of the ascending aorta by velocity vector imaging (VVI) in primary hypertension patients. The ascending aortas both in 30 patients with primary hypertension and 30 normal c... We studied the wall motion characteristics of the ascending aorta by velocity vector imaging (VVI) in primary hypertension patients. The ascending aortas both in 30 patients with primary hypertension and 30 normal controls were examined by Acuson sequoia 512 equiped with VVI. The maximum velocity (Vs, Ve) of every point on the anterior wall of ascending aorta both in systole and diastole was measured. The aortic diameter was wider in the hypertension patients than that in the healthy subjects (P〈0.05). The movement amplitude of the anterior wall of the ascending aorta in long axis view in the hypertension patients was lower than that in the healthy subjects (P〈0.05). The motion and time to peak in systole of each point of the ascending aorta in the healthy subjects had no significant difference (P〉0.05). The velocity curves of the anterior wall of ascending aorta both in the hypertension and healthy subjects were regular, and the curve in systole was named S wave and that in diastole named E wave. The velocity of S wave and E wave was slower in the hypertension patients than that in the healthy subjects (P〈0.05). The time to peak of S wave on the anterior wall of ascending aorta in systole was shorter in the hypertension patients than in the healthy subjects (P〈0.05). VVI could be used to accurately and directly observe the movement character of the ascending aorta walls, which would help us understand the elasticity of great arteries in patients with hypertension. 展开更多
关键词 velocity vector imaging HYPERTENSION ascending aorta anterior wall
下载PDF
Association of dissected ascending aorta diameter with preoperative adverse events in patients with acute type A aortic dissection
4
作者 George Samanidis Meletios Kanakis +1 位作者 Charalampos Georgiou Konstantinos Perreas 《World Journal of Cardiology》 2022年第4期231-238,共8页
BACKGROUND Acute type A aortic dissection(ATAAD)is a life-threatening disease associated with high morbidity and mortality.AIM To evaluate the diameter of dissected ascending aorta in patients diagnosed with ATAAD and... BACKGROUND Acute type A aortic dissection(ATAAD)is a life-threatening disease associated with high morbidity and mortality.AIM To evaluate the diameter of dissected ascending aorta in patients diagnosed with ATAAD and whether the aortic diameter is associated with preoperative adverse events.METHODS A total of 108 patients diagnosed with ATAAD who underwent emergency operation under hypothermic circulatory arrest were enrolled in this study.Demographic characteristics and perioperative data were recorded.In all patients,preoperative chest and abdomen computed tomography(CT)scans were performed.RESULTS Median age of the patients was 61.5(52.5-70.5)years and median body mass index(BMI)was 28.2(25.1-32.6)cm^(2).The number of female patients was 37(25%).Median diameter of the ascending aorta was 5.0(4.5-6)cm and 53.8%of the patients had an aortic diameter<5.0 cm,while 32.3%of the patients had an aortic diameter of 4.5cm and 72.0%had an ascending aorta diameter<5.5 cm.The diameter of the ascending aorta did not differ in patients with vs without preoperative adverse events:Preoperative neurological dysfunction(P=0.53)and hemodynamic instability(P=0.43).Median age of patients with preoperative hemodynamic instability was 65(57.5-74)years,while it was 60(51-68)years in patients without(P=0.04)CONCLUSION Although current guidelines suggest replacing the ascending aorta with a diameter>5.5 cm,most of the patients with ATAAD had an aortic diameter of less than 5.5 cm.The diameter of the ascending aorta in patients diagnose with ATAAD is not associated with preoperative adverse events. 展开更多
关键词 ACUTE Aortic dissection Type A ascending aorta DIAMETER
下载PDF
Traumatic Break of the Ascending Aorta: About a Case
5
作者 Abdoulaye Kante Andrea Perrotti +16 位作者 Brehima Coulibaly Mamadou Almamy Keita Drissa Traore Mamadou Diakite Mariam Daou Bakary Keita Birama Togola Nouhoum Ongoiba Harrison Haight Anne Sophie Lacagne Julie Ritter Anne Claire Mogenet Enrica Dorigo Camille Durst Djamel Kaili Francois Clement Sidney Chocron 《Open Journal of Thoracic Surgery》 2018年第4期63-67,共5页
The traumatic break of the ascending aorta is rare. We bring report the case of a 40-year-old man, a victim of accident of the public highway having caused a break of the posterior face of the ascending aorta. The exp... The traumatic break of the ascending aorta is rare. We bring report the case of a 40-year-old man, a victim of accident of the public highway having caused a break of the posterior face of the ascending aorta. The explorations scanno graphique and per operating highlighted this break. The treatment consisted of an edge-to-edge direct suture of the ascending aorta. 展开更多
关键词 Traumatic Break ascending aorta Accident of the Public Highway
下载PDF
Adventitial Rupture of the Ascending Thoracic Aorta Extended to the Buttock by Thoracic Crushing between Two Tanks at the Thoracic and Cardiovascular Surgery Department at the Besançon CHRU
6
作者 Abdoulaye Kante Andrea Perrotti +23 位作者 Brehima Coulibaly Mamadou Almamy Keita Drissa Traore Siaka Diallo Mariam Daou Mamadou Diakite Babou Bah Brehima Bengaly MoustaphIssa Magane Bakary Keita Birama Togola Drissa Ouattara Souleymane Sanogo Timbely Guidere Nouhom Ongoiba Harrison Haight Anne Sophie Lacagne Julie Ritter Anne Claire Mogenet Enrica Dorigo Camille Durst Djamel Kaili Francois Clement Sidney Chocron 《Open Journal of Thoracic Surgery》 2018年第4期74-78,共5页
Traumatic rupture of the ascending aorta is rare. We report the case of a 23-year-old man who suffered a service accident by crushing the thorax between two tanks during army maneuvers that resulted in an adventitial ... Traumatic rupture of the ascending aorta is rare. We report the case of a 23-year-old man who suffered a service accident by crushing the thorax between two tanks during army maneuvers that resulted in an adventitial rupture of the ascending thoracic aorta extending to the Crosse. Treatment consisted of replacement of the ascending aorta with a 24 mm Hemashield straight tube and re-implantation of supra-aortic vessels at the dome of the prosthesis. 展开更多
关键词 Traumatic Rupture ascending aorta Extended to Lacrosse Service Accident
下载PDF
Aortic Root and Ascending Aortic Aneurysm Related to One Case. Reimplantation of the Right Coronary Artery by 8 mm Dacron Tube (Cabrol Hemi Mustache) and Review of the Literature
7
作者 Abdoulaye Kanté Bréhima Coulibaly +6 位作者 Mamadou Diakité Samba Sidibé Drissa Traoré Bréhima Bengaly Mariam Daou Demba Yattera Nouhoum Ongoïba 《Open Journal of Thoracic Surgery》 2021年第1期1-10,共10页
The aortic aneurysm is the 13th leading cause of death in Western countries. The incidence of thoracic aortic aneurysms is estimated at 4.5 cases per 100,000. The diagnosis is often made on a chest x-ray or other imag... The aortic aneurysm is the 13th leading cause of death in Western countries. The incidence of thoracic aortic aneurysms is estimated at 4.5 cases per 100,000. The diagnosis is often made on a chest x-ray or other imaging tests, such as an echocardiogram done for other heart diseases. Echocardiography is the first test to assess the diameter of the ascending aorta and its progression over time. Most patients are first assessed and followed up with spiral thoracic computed tomography with injection of contrast medium, supplemented by 3-dimensional reconstruction of the aneurysm in order to improve the accuracy of measurements, identification of its proximal part and distal. When dilation of the ascending aorta reaches the critical diameter of 50 mm, there is a risk of aortic dissection or rupture. Supravalvular aneurysms are treated by replacing the ectatic portion with a Dacron<span style="white-space:nowrap;">&#174</span> tube in the supracoronary position. Aortic root aneurysms, including coronary ostia, require tube replacement, reimplantation of coronary ostia, as well as surgery on the aortic valve. In this article, we report a case of aneurysm of the aortic root and the ascending aorta treated by aortic valve replacement and the ascending aorta associated with the Cabrol hemi-mustache technique and we review the literature. 展开更多
关键词 Aortic Root and ascending Aortic Aneurysm Aortic Valve Replacement and ascending aorta Cabrol’s Hemi Mustache
下载PDF
A canine model of aortic arch aneurysm created with autologous pericardium
8
作者 Weixiao Li Jun Li +7 位作者 Qiang li Mingzhe Cui Rutao Xu Shuiting Zhai Cheshire Nick Tianxiao Li Jiangbo Chen Wenli Zhao 《Journal of Interventional Medicine》 2022年第3期133-137,共5页
Background:To establish a canine model of aortic arch aneurysm that is suitable for research on new devices and techniques applied to the aortic arch.Materials and methods:Fifteen mongrel dogs underwent surgery.The au... Background:To establish a canine model of aortic arch aneurysm that is suitable for research on new devices and techniques applied to the aortic arch.Materials and methods:Fifteen mongrel dogs underwent surgery.The autologous pericardial patch was sewn on the aortotomy site in the anterior wall of the aortic arch.The animals were followed up for 3 months postoperatively.Computed tomography angiography was used to visualize and measure the aneurysm model.Hematoxylin and eosin staining was used to observe the histological characteristics of the aneurysm model.Changes in aneurysm diameter over time were analyzed using analysis of variance.Results:One dog died of hemorrhage during surgery.Fourteen dogs survived the surgical procedure.Two of them died on the first postoperative day because of ruptures at the suturing margin.The diameter of the aneurysm model was twice as large as that of the aortic arch.There was no significant change in the maximum diameter of the aneurysm model during the follow-up period.Conclusions:We established a controllable and stable aortic arch aneurysm model created with an autologous pericardium patch.The aneurysm model can be used to research endoleaks after thoracic endovascular aortic repair and new endovascular techniques can be applied to the aortic arch. 展开更多
关键词 Aortic aneurysm Pericardium patch ascending aorta Aortic arch Animal model
下载PDF
Successful Surgical Treatment of a Giant Mediastinal False Aneurysm 30 Years after Bentall Operation
9
作者 Vincenzo Smorto Massimo Longo +4 位作者 Paolo Pisi Marco Meli Luca Massarenti Paolo Giovanardi Guglielmo Stefanelli 《World Journal of Cardiovascular Surgery》 2016年第3期35-39,共5页
False aneurysm occurring after replacement of ascending aorta by a vascular prosthesis is a rare, but life-threatening complication. In spite of advances in endovascular techniques, surgery remains the treatment of ch... False aneurysm occurring after replacement of ascending aorta by a vascular prosthesis is a rare, but life-threatening complication. In spite of advances in endovascular techniques, surgery remains the treatment of choice in the majority of cases. We report the case of a huge pseudoaneurysm caused by late dehiscence of the right coronary ostium-aortic tubular graft anastomosis, occurred 30 years after replacement of aortic valve and ascending aorta by classical Bentall operation. A fistula originating from the aneurysmal sac extended across the sternum into the thoracic subcutaneous soft tissues and gave rise to a pulsatile mass well appreciable on the anterior chest wall. The surgical treatment, consisting of partial resection of the aortic tubular graft and sternal reconstruction was effective and uneventful. 展开更多
关键词 Re-Do Aortic Surgery False Aneurysm of the ascending aorta Bentall Operation
下载PDF
Very large aortic pseudoaneurysm repair using a septal occluder
10
作者 Paulo R.A.Caramori Ricardo Lasevitch +5 位作者 Mauricio L.Suksteris Ricardo M.Pianta Joao B.Petracco Fabiano Ramos Fabio M.Velho Felipe S.Torres 《Discussion of Clinical Cases》 2021年第2期14-17,共4页
A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous interven... A 63-year-old man,with previous coronary artery bypass surgery presented with infectious aortitis and a large ascending aorta pseudoaneurysm,causing compression of the left internal mammary graft.Percutaneous intervention with stenting of the graft followed by closure of the pseudoaneurysm using an atrial septal defect occluder was successfully carried out. 展开更多
关键词 ascending aorta PSEUDOANEURYSM Percutaneous repair Septal occluder
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部