Quantity of trace arsenic in grain and soil was determined by hydride nondispersive atomic fluorescence method.Optimum conditions of measurement were selected in the experiment including the pH of the medium, reductiv...Quantity of trace arsenic in grain and soil was determined by hydride nondispersive atomic fluorescence method.Optimum conditions of measurement were selected in the experiment including the pH of the medium, reductive agent, the concentration and flowing velocity of KBH4, rate of carrier gas and atomized temperature. The reference sample of rice C was determined and the linear relationship of the calibration curve was plotted, indicating that the method was highly precise. In the experiment of recovery rate, the method was quite satisfactory.Based on the determination of hundreds of samples, it is proved that atomic fluorescence method is rapid, sensitive and low in interference. It is very efficient on determination of trace arsenic in soils and grains, especially in grains.展开更多
In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in det...In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.展开更多
The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectro...The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More展开更多
A new multi-element analysis technique based on laser-excited atomic fluorescence was reviewed. However, the one-wavelength-one-transition constraint was overcome. Numerous elements were induced to fluoresce at a sing...A new multi-element analysis technique based on laser-excited atomic fluorescence was reviewed. However, the one-wavelength-one-transition constraint was overcome. Numerous elements were induced to fluoresce at a single excitation wavelength of 193 nm. This was possible provided that the analytes were imbedded in dense plumes, such as those produced by pulsed laser ablation. The underlying mechanism of the technique was explained and corroborated. Analytical applications to metals, plastics, ceramics and their composites were discribed. Detection limits in the ng/g range and mass limits of atto moles were demonstrated. Several real-world problems, including the analysis of paint coating for trace lead, the non-destructive analysis of potteries and ink, the chemical profiling of electrode plastic interfaces, and the analysis of ingestible lead colloids were discussed.展开更多
A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS...A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS). After the compound is reduced with potassium borohydrid(KBH4), the resultant mercury vapor was injected into the instrument and iodine was, therefore, indirectly determined. Experimental parameters such as the conditions of extraction reagents, aqueous phase acidity, elemental mercury diffusion temperature in a vial and other factors were investigated and optimized. Under the optimum experimental conditions, this method shows a detection limit of 0.038μg/L iodine and a linear relationship between 0.04-20 p.g/L. The method was applied to determining the iodine content in marine duck eggs, kelps, laver and Ganoderma lucidum spirulina, showing a relative standard deviation(RSD) of 2.15% and the recoveries in the range of 98.1%-102.5%.展开更多
Atomic density is a basic and important parameter in quantum optics, nonlinear optics, and precision measurement.In the past few decades, several methods have been used to measure atomic density, such as thermionic ef...Atomic density is a basic and important parameter in quantum optics, nonlinear optics, and precision measurement.In the past few decades, several methods have been used to measure atomic density, such as thermionic effect, optical absorption, and resonance fluorescence. The main error of these experiments stemmed from depopulation of the energy level, self-absorption, and the broad bandwidth of the laser. Here we demonstrate the atomic density of^87 Rb vapor in paraffin coated cell between 297 K and 334 K mainly using fluorescence measurement. Optical pumping, anti-relaxation coating, and absorption compensation approaches are used to decrease measurement error. These measurement methods are suitable for vapor temperature at dozens of degrees. The fitting function for the experimental data of87 Rb atomic density is given.展开更多
Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of va...Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of various spectroscopic techniques, mainly including atomic absorption spectrometry (AAS) inductively coupled plasma emission spectrometry (ICP-AES) X-ray fluorescence spectroscopy (XRF) atomic fluorescence spectroscopy (AFS) direct reading spectroscopy (OES) glow discharge emission spectroscopy (GD-OSE) laser-induced breakdown spectroscopy (LIBS), in the formulation of non-ferrous metal standards in China. The AAS method was the most widely used single-element microanalysis method among the non-ferrous metal standards. The ICP-AES method was good at significant advantages in the simultaneous detection of multiple elements. The XRF method was increasingly used in the determination of primary and secondary trace elements due to its simple sample preparation and high efficiency. The AFS was mostly detected by single-element trace analysis. OES GD-OES and LIBS were playing an increasingly important role in the new demand area for non-ferrous metals. This paper discussed matrix elimination, sample digestion, sample preparation, instrument categories and other aspects of some standards, and summarized the advantages of spectral analysis and traditional chemical analysis methods. The new methods of future spectroscopic technology had been illustrated in the process of developing non-ferrous metal standards.展开更多
The soil heavy metals(Hg and As)in Duanzhou District of Zhaoqing City were determined by AFS200 T atomic fluorescence spectropho-tometer,and the soil environment in Duanzhou District was evaluated by several evaluatio...The soil heavy metals(Hg and As)in Duanzhou District of Zhaoqing City were determined by AFS200 T atomic fluorescence spectropho-tometer,and the soil environment in Duanzhou District was evaluated by several evaluation methods of soil heavy metal pollution,such as single factor index method,pollution load index method and Nemerow comprehensive pollution index method.Finally,according to the data and conclu-sions,the soil pollution situation in Duanzhou District of Zhaoqing was analyzed.The results will let more people pay attention to the changes of the environment and realize the harm of the environment,and the government can formulate a new plan conducive to the coordinated development of the environment and economy.展开更多
To investigate the correlation between hair selenium (Se) level and gastric cancer. Methods: Atomic fluorescence spectrophotometer(AFS) was used to detect the Se level in hair. Results: The Se concentration in p...To investigate the correlation between hair selenium (Se) level and gastric cancer. Methods: Atomic fluorescence spectrophotometer(AFS) was used to detect the Se level in hair. Results: The Se concentration in patients with gastric cancer ranged from 0.25 to 2.33 μg/g(0.825 ± 0.51 μg/g), and that of health individuals ranged from 4.23 to 9.21 μg/g(6.29± 1.68 μg/g). The results showed that the Se concentration in the patients' hair was significantly lower than that in controls (P 〈 0.01). Conclusion: There is a correlation between hair concentration and gastric cancer.展开更多
Two 1,8-naphthalimide derivatives of 7H-benzimidazo[2,1,-a]benz[de] isoquino- lin-7-one(1) and 4-bromo-7H-benzimidazo[2,1,-a]benz[de]isoquinolin-7-one(2) have been synthesized and characterized by elemental analys...Two 1,8-naphthalimide derivatives of 7H-benzimidazo[2,1,-a]benz[de] isoquino- lin-7-one(1) and 4-bromo-7H-benzimidazo[2,1,-a]benz[de]isoquinolin-7-one(2) have been synthesized and characterized by elemental analysis, IR, 1H NMR, UV-Vis and fluorescence spectra. For the two compounds, density functional theory(DFT) calculations of the structures and natural population atomic charge analysis have been performed at the B3LYP/6-311G** level of theory. Based on Onsager reaction filed model and by using TD-DFT method at the B3LYP/6-311G** level, electron spectra of 1 and 2 with solvent effect in CHCl3 solvent have been predicted, which are in agreement with the experimental ones. Comparative studies on 1 and 2 indicate that introducing an electron-withdrawing group of Br into the 4-position of naphthalene ring in 2 does not significantly make the molecular geometry of 2 different from that of 1, but evidently changes the atomic charge redistribution, moves the positive-negative charges center and then changes the dipole moment in 2. Additionally, for compound 2, the existence of Br atom has also influenced the peak intensity and peak locations in both electron and fluorescence spectra.展开更多
A fluorescence detection scheme is applied to image an atomic beam. Using two laser diodes as the sources of detection light and pumping light respectively, the fluorescence image of the atomic beam is then observed b...A fluorescence detection scheme is applied to image an atomic beam. Using two laser diodes as the sources of detection light and pumping light respectively, the fluorescence image of the atomic beam is then observed by a commercial CCD-camera, which is corresponding to the atomic state and velocity distribution. The detection scheme has a great utilization in the experiments of cold atoms and atomic optics.展开更多
Flue gas from coal combustion contains significant amounts of volatile selenium (Se). The capture of Se in the flue gas desulfurization (FGD) scrubber unit has resulted in a generation of metal-laden residues. It ...Flue gas from coal combustion contains significant amounts of volatile selenium (Se). The capture of Se in the flue gas desulfurization (FGD) scrubber unit has resulted in a generation of metal-laden residues. It is important to determine Se speciation to understand the environmental impact of its disposal. A simple method has been developed for selective inorganic Se(IV), Se(VI) and organic Se determination in the liquid-phase FGD residues by hydride generation atomic fluorescence spectrometry (AFS). It has been determined that Se(IV), Se(VI) and organic Se can be accurately determined with detection limits (DL) of 0.05, 0.06 and 0.06 μg/L, respectively. The accuracy of the proposed method was evaluated by analyzing the certified reference material, NIST CRM 1632c, and also by analyzing spiked tap-water samples. Analysis indicates that the concentration of Se is high in FGD liquid residues and primarily exists in a reduced state as selenite (Se(IV)). The toxicity of Se(IV) is the strongest of all Se species. Flue gas desulfurization residues pose a serious environmental risk.展开更多
文摘Quantity of trace arsenic in grain and soil was determined by hydride nondispersive atomic fluorescence method.Optimum conditions of measurement were selected in the experiment including the pH of the medium, reductive agent, the concentration and flowing velocity of KBH4, rate of carrier gas and atomized temperature. The reference sample of rice C was determined and the linear relationship of the calibration curve was plotted, indicating that the method was highly precise. In the experiment of recovery rate, the method was quite satisfactory.Based on the determination of hundreds of samples, it is proved that atomic fluorescence method is rapid, sensitive and low in interference. It is very efficient on determination of trace arsenic in soils and grains, especially in grains.
文摘In this paper, a new MPT(microwave plasma torch) device has been used as a atomizer for atomic fluorescence spectrometry. Spme elements, such as Zn, Cd, Hg, Pb, As, Co, Mg, Cu, Ag, Mn, Fe have been investigated in detail.
文摘The Microwave-Induced Plasma (MIP) has received considerable attention during the past decade since theintroduction of the Becnakker Cavity. It has been commonly used as an atomization cell for atomic emission spectrometry (AES) and atomic absorption spectrometry (AAS), and a great success was achieved for both techniques. More
文摘A new multi-element analysis technique based on laser-excited atomic fluorescence was reviewed. However, the one-wavelength-one-transition constraint was overcome. Numerous elements were induced to fluoresce at a single excitation wavelength of 193 nm. This was possible provided that the analytes were imbedded in dense plumes, such as those produced by pulsed laser ablation. The underlying mechanism of the technique was explained and corroborated. Analytical applications to metals, plastics, ceramics and their composites were discribed. Detection limits in the ng/g range and mass limits of atto moles were demonstrated. Several real-world problems, including the analysis of paint coating for trace lead, the non-destructive analysis of potteries and ink, the chemical profiling of electrode plastic interfaces, and the analysis of ingestible lead colloids were discussed.
文摘A method for the determination of iodine based upon compound H2HgI4, formed between I- and Hg1+ in nitric acid and extracted in methyl isobutyl ketone(MIBK), was developed via atomic fluorescence spectrometry(AFS). After the compound is reduced with potassium borohydrid(KBH4), the resultant mercury vapor was injected into the instrument and iodine was, therefore, indirectly determined. Experimental parameters such as the conditions of extraction reagents, aqueous phase acidity, elemental mercury diffusion temperature in a vial and other factors were investigated and optimized. Under the optimum experimental conditions, this method shows a detection limit of 0.038μg/L iodine and a linear relationship between 0.04-20 p.g/L. The method was applied to determining the iodine content in marine duck eggs, kelps, laver and Ganoderma lucidum spirulina, showing a relative standard deviation(RSD) of 2.15% and the recoveries in the range of 98.1%-102.5%.
基金Project supported by the Natural Science Foundation of China(Grant Nos.11274118 and 11474095)the Innovation Program of Shanghai Municipal Education Commission of China(Grant No.13ZZ036)the Fundamental Research Funds for the Central Universities of China
文摘Atomic density is a basic and important parameter in quantum optics, nonlinear optics, and precision measurement.In the past few decades, several methods have been used to measure atomic density, such as thermionic effect, optical absorption, and resonance fluorescence. The main error of these experiments stemmed from depopulation of the energy level, self-absorption, and the broad bandwidth of the laser. Here we demonstrate the atomic density of^87 Rb vapor in paraffin coated cell between 297 K and 334 K mainly using fluorescence measurement. Optical pumping, anti-relaxation coating, and absorption compensation approaches are used to decrease measurement error. These measurement methods are suitable for vapor temperature at dozens of degrees. The fitting function for the experimental data of87 Rb atomic density is given.
文摘Spectral analysis was a method of identifying substances, determining their chemical composition and calculating their content based on their spectral characteristics. This paper mainly discussed the application of various spectroscopic techniques, mainly including atomic absorption spectrometry (AAS) inductively coupled plasma emission spectrometry (ICP-AES) X-ray fluorescence spectroscopy (XRF) atomic fluorescence spectroscopy (AFS) direct reading spectroscopy (OES) glow discharge emission spectroscopy (GD-OSE) laser-induced breakdown spectroscopy (LIBS), in the formulation of non-ferrous metal standards in China. The AAS method was the most widely used single-element microanalysis method among the non-ferrous metal standards. The ICP-AES method was good at significant advantages in the simultaneous detection of multiple elements. The XRF method was increasingly used in the determination of primary and secondary trace elements due to its simple sample preparation and high efficiency. The AFS was mostly detected by single-element trace analysis. OES GD-OES and LIBS were playing an increasingly important role in the new demand area for non-ferrous metals. This paper discussed matrix elimination, sample digestion, sample preparation, instrument categories and other aspects of some standards, and summarized the advantages of spectral analysis and traditional chemical analysis methods. The new methods of future spectroscopic technology had been illustrated in the process of developing non-ferrous metal standards.
基金Supported by Special Projects in Key Fields of Universities and Colleges in Guangdong Province(2021ZDZX4023)Special Fund Project for Enterprise Science and Technology Commissioners of Guangdong Province in 2020(GDKTP2020059100)+1 种基金Quality Engineering and Educational Reform Project of Zhaoqing University(zlgc 201931)Guangdong Provincial Key Laboratory of Environmental Health and Land Resource(2020B121201014)
文摘The soil heavy metals(Hg and As)in Duanzhou District of Zhaoqing City were determined by AFS200 T atomic fluorescence spectropho-tometer,and the soil environment in Duanzhou District was evaluated by several evaluation methods of soil heavy metal pollution,such as single factor index method,pollution load index method and Nemerow comprehensive pollution index method.Finally,according to the data and conclu-sions,the soil pollution situation in Duanzhou District of Zhaoqing was analyzed.The results will let more people pay attention to the changes of the environment and realize the harm of the environment,and the government can formulate a new plan conducive to the coordinated development of the environment and economy.
文摘To investigate the correlation between hair selenium (Se) level and gastric cancer. Methods: Atomic fluorescence spectrophotometer(AFS) was used to detect the Se level in hair. Results: The Se concentration in patients with gastric cancer ranged from 0.25 to 2.33 μg/g(0.825 ± 0.51 μg/g), and that of health individuals ranged from 4.23 to 9.21 μg/g(6.29± 1.68 μg/g). The results showed that the Se concentration in the patients' hair was significantly lower than that in controls (P 〈 0.01). Conclusion: There is a correlation between hair concentration and gastric cancer.
基金Supported by Doctor Foundation of Shandong Province(No.BS2010CL021)Natural Science Foundation of Shandong Province(ZR2009AL020)Jiangsu Key Laboratory for Chemistry of Low-dimensional Materials P.R.China(JSKC12106 and JSKC12107)
文摘Two 1,8-naphthalimide derivatives of 7H-benzimidazo[2,1,-a]benz[de] isoquino- lin-7-one(1) and 4-bromo-7H-benzimidazo[2,1,-a]benz[de]isoquinolin-7-one(2) have been synthesized and characterized by elemental analysis, IR, 1H NMR, UV-Vis and fluorescence spectra. For the two compounds, density functional theory(DFT) calculations of the structures and natural population atomic charge analysis have been performed at the B3LYP/6-311G** level of theory. Based on Onsager reaction filed model and by using TD-DFT method at the B3LYP/6-311G** level, electron spectra of 1 and 2 with solvent effect in CHCl3 solvent have been predicted, which are in agreement with the experimental ones. Comparative studies on 1 and 2 indicate that introducing an electron-withdrawing group of Br into the 4-position of naphthalene ring in 2 does not significantly make the molecular geometry of 2 different from that of 1, but evidently changes the atomic charge redistribution, moves the positive-negative charges center and then changes the dipole moment in 2. Additionally, for compound 2, the existence of Br atom has also influenced the peak intensity and peak locations in both electron and fluorescence spectra.
文摘A fluorescence detection scheme is applied to image an atomic beam. Using two laser diodes as the sources of detection light and pumping light respectively, the fluorescence image of the atomic beam is then observed by a commercial CCD-camera, which is corresponding to the atomic state and velocity distribution. The detection scheme has a great utilization in the experiments of cold atoms and atomic optics.
基金supported by the National Natural Science Foundation of China (No.90410018)the Shanxi Nature Science Foundation (No.20051017)+1 种基金the Shanxi Returned Scholar Research Project (No.2005-21)the Programfor Changjiang Scholars and Innovative Research Team at University in MOE,China (No.IRT0517)
文摘Flue gas from coal combustion contains significant amounts of volatile selenium (Se). The capture of Se in the flue gas desulfurization (FGD) scrubber unit has resulted in a generation of metal-laden residues. It is important to determine Se speciation to understand the environmental impact of its disposal. A simple method has been developed for selective inorganic Se(IV), Se(VI) and organic Se determination in the liquid-phase FGD residues by hydride generation atomic fluorescence spectrometry (AFS). It has been determined that Se(IV), Se(VI) and organic Se can be accurately determined with detection limits (DL) of 0.05, 0.06 and 0.06 μg/L, respectively. The accuracy of the proposed method was evaluated by analyzing the certified reference material, NIST CRM 1632c, and also by analyzing spiked tap-water samples. Analysis indicates that the concentration of Se is high in FGD liquid residues and primarily exists in a reduced state as selenite (Se(IV)). The toxicity of Se(IV) is the strongest of all Se species. Flue gas desulfurization residues pose a serious environmental risk.