期刊文献+
共找到40篇文章
< 1 2 >
每页显示 20 50 100
Determination of Ultratrace Amounts of Copper(Ⅱ) in Water Samples by Electrothermal Atomic Absorption Spectrometry After Cloud Point Extraction 被引量:10
1
作者 CHEN Jian-guo CHEN neng-wu +2 位作者 CHEN Shao-hong LIN Li ZHONG Ying-ying 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2007年第2期143-147,共5页
A novel approach was developed for the determination of ultratrace amounts of copper in water samples by using electrothermal atomic absorption spectrometry (ETAAS) after cloud point extraction ( CPE ). 1-( 2-Pyr... A novel approach was developed for the determination of ultratrace amounts of copper in water samples by using electrothermal atomic absorption spectrometry (ETAAS) after cloud point extraction ( CPE ). 1-( 2-Pyridylazo ) -2- naphthol was used as the chelating reagent and Triton X-114 as the mieellar-forming surfactant. CPE was conducted in a pH 8. 0 medium at 40 ℃ for 10 rain. After the separation of the phases by contrifugafion, the surfactant-rieh phase was diluted with 1 mL of a methanol solution of 0. 1 mol/L HNO3. Then 20μL of the diluted surfactant-rieh phase was injected into the graphite furnace for atomization in the absence of any matrix modifier. Various experimental conditions that affect the extraction and atomization processes were optimized. A detection limit of 5 ng/L was obtained after preconeentration. The linear dynamic range of the copper mass concentration was found to be 0-2.0 ng/mL, and the relative standard deviation was found to be less than 3. 1% for a sample containing 1.0 ng/mL Cu ( Ⅱ ). This developed method was successfully applied to the determination of uhratraee amounts of Cu in drinking water, tap water, and seawater samples. 展开更多
关键词 Cloud point extraction Preconeentration Electrothermal atomic absorption spectrometry Copper( Ⅱ) Water analysis
下载PDF
Cloud point extraction and flame atomic absorption spectrometry analysis of palladium, platinum, and gold ions from industrial polluted soil 被引量:5
2
作者 LIAN Yuanpei ZHEN Wei +3 位作者 TAI Zhigang YANG Yaling SONG Jun LI Zonghao 《Rare Metals》 SCIE EI CAS CSCD 2012年第5期512-516,共5页
关键词 cloud point extraction ammonium pyrolysine dithiocarbamate Tergitol TMN-6 Pd Pt AU atomic absorption spectrometry
下载PDF
Determination of total arsenic by photo-decomposition of organoarsenic compounds and hydride generation electrothermal atomic absorption spectrometry 被引量:4
3
作者 Han Hengbin, Liu Yanbing, Zhang Shuzhen Ni ZhemingResearch Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P. O. Box 2871, Beijing 100085, China 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 1993年第1期99-107,共9页
A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a p... A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml levels. 展开更多
关键词 electrothermal atomic absorption spectrometry photo -decomposition organoarsenic compounds arsenic hydride generation tap/lake water
下载PDF
Determination of Trace Amounts of Nickel (Ⅱ) by Graphite Furnace Atomic Absorption Spectrometry Coupled with Cloud Point Extraction 被引量:3
4
作者 SHAH Syed Mazhar WANG Hao-nan SU Xing-guang 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2011年第3期366-370,共5页
A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-... A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-hydroxyquinoline and Triton X-100 were used as the ligand and surfactant respectively. Nickel(Ⅱ) can form a hy-drophobic complex with 8-hydroxyquinoline, the complex can be extracted into the small volume surfactant rich phase at the cloud point temperature(CPT) for GFAAS determination. The factors affecting the cloud point extraction, such as pH, ligand concentration, surfactant concentration, and the incubation time were optimized. Under the optimal conditions, a detection limit of 12 ng/L and a relative standard deviation(RSD) of 2.9% were obtained for Ni(Ⅱ) determination. The enrichment factor was found to be 25. The proposed method was successfully applied to the determination of nickel(Ⅱ) in certified reference material and different types of water samples and the recovery was in a range of 95%―103%. 展开更多
关键词 Cloud point extraction Phase separation Graphite furnace atomic absorption spectrometry Nickel(Ⅱ)
下载PDF
Application of multiwalled carbon nanotubes treated by potassium permanganate for determination of trace cadmium prior to flame atomic absorption spectrometry 被引量:3
5
作者 XIAO Jun-ping ZHOU Qing-xiang BAI Hua-hua 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第10期1266-1271,共6页
In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption ... In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption spectrometry. The MWCNTs were oxidized by potassium permanganate under appropriate conditions before use as preconcentration packing. Parameters influencing the recoveries of target analytes were optimized. Under optimal conditions, the target analyte exhibited a good linearity (R^2=0.9992) over the concentration range 0.5-50 ng/ml. The detection limit and precision of the proposed method were 0.15 ng/ml and 2.06%, respectively. The proposed method was applied to the determination of cadmium in real-world environmental samples and the recoveries were in the range of 91.3%-108.0%. All these experimental results indicated that this new procedure could be applied to the determination of trace cadmium in environmental waters. 展开更多
关键词 multiwalled carbon nanombes (MWCNTs) solid-phase extraction flame atomic absorption spectrometry
下载PDF
Flow Injection Semi-online Preconcentration Graphite Furnace Atomic Absorption Spectrometry for Determination of Cadmium,Copper and Manganese 被引量:3
6
作者 ZHANG Yi-hua, WANG Mei-jia, SU Xing-guang, ZHENG Tao, ZHANG Han-qi and JIN Qin-han Department of Chemistry, Jilin University, Changchun 130023, P. R. ChinaCHEN YingJilin Environmental Monitoring Centre, Changchun 130011, P. R. China 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2002年第1期1-7,共7页
A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements... A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements. The analytical performances of the prospsed method for determining Cd, Cu and Mn were studied. The analytes were preconcentrated with a thiol resin(Type 190, produced by Nankai University, China) whose active group is -SH. The elements to be determined were preconcentrated onto the column for 60 s and then rinsed with deionized water and eluted with 30 μL of 1 mol/L HCl. The graphite furnace atomic absorption spectrometry(GFAAS) determination of the concentrated analyte was carried out in parallel with the next preconcentration cycle. Enrichment factors 41, 22 and 20 and detection limits(3 σ , n =10) 0.36, 3.8 and 7.0 ng/L for Cd, Cu and Mn, respectively, along with a sampling frequency of 20 h -1 , were obtained with a 60 s loading time at a sample flow rate of 3.5 mL/min. The analytical results for a number of water samples show that the flow-injection semi-online column preconcentration can not only eliminate the effect of some concomitant elements, such as Li, Na, K, Ca and Mg, on the determination of the analyte, but also enhance the sensitivity. 展开更多
关键词 FLOW-INJECTION Semi-online preconcentration atomic absorption spectrometry Cadmium Copper Manganese
下载PDF
On-line Preconcentration of Trace Nickel from Electrolytic Manganese Using Minicolumn Packed Activated Carbon for Electrothermal Atomic Absorption Spectrometry 被引量:2
7
作者 姚俊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2004年第4期17-20,共4页
The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn... The online flow injection preconcentration and electrothermal atomic absorption spectrometry method were used for the determination of trace nickel in electrolytic manganese samples by sorption on a conical minicolumn packed with activated carbon at pH 9.0. The nickel was eluted from the minicolumn with 10%(v/v) nitric acid. An enrichment factor of 190-fold for a sample volume of 10mL was obtained. The detection limit (DL) of nickel with the use of the preconcentration method was 13ng·g -1in the original solid sample. The precision for 10 replicate determinations at 150ng·g -1 nickel concentration was 5.2% relative standard deviation (RSD). The calibration graph was linear with a correlation coefficient of r=0.9996 up to concentration of 660ng·g -1 nickel. 展开更多
关键词 online preconcentration NICKEL electrothermal atomic absorption spectrometry activated carbon electrolytic manganese
下载PDF
Preconcentration of copper with multi-walled carbon nanotubes pretreated by potassium permanganate cartridge for solid phase extraction prior to flame atomic absorption spectrometry 被引量:2
8
作者 Jun Ping Xiao Qing Xiang Zhou Hua Hua Bai 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第6期714-717,共4页
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s... A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment. 展开更多
关键词 Multi-walled carbon nanotubes Solid phase extraction (SPE) Flame atomic absorption spectrometry
下载PDF
Preconcentration of Vanadium(Ⅴ) on Crosslinked Chitosan and Determination by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
9
作者 Wu Wei Qian Sha-hua +2 位作者 Xiao Mei Huang Gan-quan Chen Hao 《Wuhan University Journal of Natural Sciences》 CAS 2002年第2期222-226,共5页
A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by C... A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by CCTS was 97% at pH 4.0, and vanadium(Ⅴ) was eluted from crosslinked chitosan with 2 mL 2.0 mol·L -1 chlorhydric acid and determined by GFAAS. The detection limit (3σ,n=7) for vanadium(Ⅴ) was 4.8×1 0 -12g and the relative standard deviation (R.S.D) at concentration level of 2.6 μg·L -1 is less than 3.6%. The method shows a good selectivity and high sensitivity, and it was applied to determination of vanadium(Ⅴ) in oyster and water samples. The analytic recoveries are (97±5)%. 展开更多
关键词 crosslinked chitosan (CCTS) vanadium(Ⅴ) PRECONCENTRATION DESORPTION graphite furnace atomic absorption spectrometry (GFAAS) OYSTER sea water
下载PDF
Determination of Iron in Layered Crystal Sodium Disilicate and Sodium Silicate by Flame Atomic Absorption Spectrometry with Boric Acid as a Matrix Modifier 被引量:1
10
作者 Zhi Hua WANG Min CAI Shu Jun WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第6期809-812,共4页
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously e... The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5 μg.mL^-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%- 101%, the sensitivity is 0.19 μg.mL^-l and the detection limit is 77 ng.mL^-1. The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis. 展开更多
关键词 Layered crystal sodium disilicate sodium silicate flame atomic absorption spectrometry determination of iron boric acid.
下载PDF
Determination of Trace Selenium in Electrolytic Manganese by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
11
作者 姚俊 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2003年第2期32-34,共3页
The effects of four types of graphite tube and five matrix modifiers on the determination of selenium by graphite furnace atomic absorption spectrometry were compared.The results show that platform thermolysis coat gr... The effects of four types of graphite tube and five matrix modifiers on the determination of selenium by graphite furnace atomic absorption spectrometry were compared.The results show that platform thermolysis coat graphite tube and magnesium nitrate and cobaltco as matrix modifer can get a high sensitivity and a good recovery.The optimized working conditions and interference in the determination were invesigated.This result is consistent with that of XRF.The recovery is from 100.8 % to102.2 %,the relative standard deviation is from 3.47% to 5.56 % (n=9),and the detection limit of selenium is 378 pg (C=44.5μg/g to 97.3μg/g.).The proposed method can be applied to the rapid determination of selenium in electrolytic manganese. 展开更多
关键词 electrolytic manganese SELENIUM matrix modifier atomic absorption spectrometry
下载PDF
Determination of Trace Iron in High Purity Sodium Fluoride by Graphite Furnace Atomic Absorption Spectrometry 被引量:1
12
作者 QIAN Sha-hua HUANG Gan-quan +2 位作者 XUE Ai-fang CHEN Li-hua WANG Mei-lin (College of Chemistry and Environmental Science, Wuhan University, Wuhan, 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 2000年第1期106-108,共3页
A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that th... A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that the ashing temperature can be increased to 1 400°C and matrix interferences eliminated, the sensitivity of iron increased in 1. 27 fold by the addition of nickel nitrate. The method is applied to the determination of iron in sodium fluoride and satisfactory results are obtained. 展开更多
关键词 Key words Graphite furnace atomic absorption spectrometry iron determination sodium fluoride matrix modifier
下载PDF
Uncertainty in Detecting Copper and Zinc Contents in Maize Flour by Flame Atomic Absorption Spectrometry with Wet Digestion Method 被引量:1
13
作者 Jianghua SHAN 《Agricultural Biotechnology》 CAS 2016年第1期1-4,7,共5页
[ Objective] This study aimed to evaluate the uncertainty in detecting copper and zinc contents in maize flour by flame atomic absorption spectrometry. [ Method] Combined with the actual inspection experience, the unc... [ Objective] This study aimed to evaluate the uncertainty in detecting copper and zinc contents in maize flour by flame atomic absorption spectrometry. [ Method] Combined with the actual inspection experience, the uncertainty in detecting copper and zinc contents in maize flour by tame atomic absorption spec- trometry was evaluated to establish the mathematical model. The uncertainty sources in the experimental process were investigated to analyze several components af- fecting the uncertainty in sample detection, including sample weighing, standard material transfer, solution dilution and volume setting, curve fitting, and repeat- ability of measurement instruments. [ Result] Standard curve fitting and repeatability test were two major factors that significantly affected the combined standard uncertainty. However, in the actual detection process, standard curve calibration and repeated detection procedures should be controlled strictly. Finally, the ex- panded uncertainty of copper and zinc contents in maize flour was ( 1.38 ± 0.08) mg/kg and ( 10.20 ± 1.20) mg/kg, respectively. [ Conclusion] This study provided reference for improving the accuracy and reliability of the detection method. 展开更多
关键词 atomic absorption spectrometry UNCERTAINTY Maize flour COPPER ZINC
下载PDF
DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION ATOMIC ABSORPTION SPECTROMETRY WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION
14
作者 Shu Kun XU and Zhao Lun FANG Institute of Applied Ecology, Academia Sinica, Shenyang, 110015 《Chinese Chemical Letters》 SCIE CAS CSCD 1992年第11期915-918,共4页
On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(... On-line ion-exchange separation and preconcentration were combined with flow-injection hydride generation atomic absorption spectrometry (HGAAS) to determine ultra-trace amounts of antimony in water samples. Antimony(Ⅲ) was preconcentrated on a micro-column packed with CPG-8Q chelating ion-exchanger using time-based sample loading and eluted by 4 mol l^(-1) HCl directly into the hydride generation AAS system. A detection limit (3σ) of 0.0015μg l^(-1) Sb(Ⅲ) was obtained on the basis of a 20 fold enrichment and with a sampling frequency of 60h^(-1). The precision was 1.0% r.s.d.(n=11) at the 0.5μg l^(-1) Sb(Ⅲ) level. Recoveries for the analysis of antimony in tap water, snow water and sea water samples were in the range 97-102%. 展开更多
关键词 Zhang DETERMINATION OF ANTIMONY IN WATER SAMPLES BY FLOW-INJECTION HYDRIDE GENERATION atomic absorption spectrometry WITH ON-LINE ION-EXCHANGE COLUMN PRECONCENTRATION SQ CPG ION LINE
下载PDF
A Study of the Background Absorption of Slurry Algae in the Graphite Furnace Atomic Absorption Spectrometry
15
作者 MO Sheng-jun, SONG Jian-yi, LIN Zhuo-xin and TONG You-wen (Department of Chemistry, South China Normal University, Guangzhou, 510631) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1993年第3期256-260,共5页
In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples an... In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples and cadmium from river water samples by unicellular green algae and were determined by slurry GFAAS. Dar- 展开更多
关键词 Graphite furnace atomic absorption spectrometry (GFAAS) Background absorption ALGAE
下载PDF
Determination of CaO in Baotou Columbite and Steel Cinder with Flame Atomic Absorption Spectrometry
16
作者 LI Jianqiang (Applied Science School, USTB, Beijing 100083, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1997年第2期62-62,共1页
The determination of CaO content in columbite and steel cinder with flame atomic absorption spectrometry is studied. EDTA+TEA is used to eliminate the interferences, in HCI media,with La as releaser. The methods of sa... The determination of CaO content in columbite and steel cinder with flame atomic absorption spectrometry is studied. EDTA+TEA is used to eliminate the interferences, in HCI media,with La as releaser. The methods of sample treatment and the CaO in remainder undissolved in acids have been conducted. The result of the determination and recovery of CaO shows that the rate of recovery is 100% ~ 102 %, R. S.D<2 %. 展开更多
关键词 atomic absorption spectrometry CaO columbite steel cinder
下载PDF
Determination of Impurity Silicon in Anticancer Drug (Ge-132) by Electrothermally Atomised Atomic Absorption Spectrometry with Optical Temperature Control Accessory
17
作者 Xie Shujuan, Wang Daning and Zou Mingqiang (Jilin I/E Commodity Inspection Bureau, Changchun)Cui Xiaoyuan,Ren Yulin and Zheng Yansheng (Department of Chemistry, Jilin University, Changchun)Wang Jincheng (Dalian Military Medical School, Dalian) 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1991年第4期205-211,共7页
The present paper describes the ashing and atomization processes in silicon analysis by electrothermally atomised atomic absorption spectrometry(EAAAS) with an uncoat-ed graphite tube, a pyrolytically coated graphite ... The present paper describes the ashing and atomization processes in silicon analysis by electrothermally atomised atomic absorption spectrometry(EAAAS) with an uncoat-ed graphite tube, a pyrolytically coated graphite tube and a tungsten-coated graphitetube. The sensitivity and linear range of three graphite tubes were compared. By using optical temperature control accessory, the signals are enhanced by a factor of 2 and the germanium interferences in the determination of silicon are eliminated. The effects of time constant and carrier gas flow-rate on the determination of silicon were also tested. The sample can be directly analyzed in its aqueous solution without any pretreatment. The measurements of samples containing 0. 2 μg/mL and 0. 4 μg/mL silicon were run ten times and the variation coefficient is 4. 9% and 2.6%, respectively. The recovery tests for carboxyethyl germanium sesquioxide(Ge-132) synthesized and imported were performed, and the recoveries are 97. 0% and 110%, respectively. Keywords Carboxyethyl germanium sesquioxide, Electrothermally atomised atomic absorption spectrometry, Silicon 展开更多
关键词 Determination of Impurity Silicon in Anticancer Drug by Electrothermally Atomised atomic absorption spectrometry with Optical Temperature Control Accessory GE-132
下载PDF
Determination of Pb Content in Soil Samples by Graphite Furnace Atomic Absorption Spectrometry
18
作者 Feng Huang Yihu Zeng +1 位作者 Jinxian Tang Ting Yang 《Meteorological and Environmental Research》 CAS 2013年第9期32-33,共2页
[ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydroch... [ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydrochloric acid system. Palladium nitrate was added to eliminate ma- trix interference. Digestion acid, ashing and atomization temperature of the sample were selected. The operating parameters of instrument and tem- perature-rise program of graphite furnace were optimized. National standard matter was used to verify accuracy of the method. [Result] The detec- tion limit for Pb was 0.27 μg/g by graphite furnace atomic absorption spectrometry, and the recovery rate was 91.0% -96.1%. [ Conclusion The method had rapid analysis velocity, high sensitivity, less interference and easy operation. When applied to determination of trace Pb in the soil, the method obtained satisfactory results. 展开更多
关键词 Graphite furnace atomic absorption spectrometry SOIL PB China
下载PDF
Determination of Manganese in Tri Calcium Phosphate (TCP) by Atomic Absorption Spectrometry
19
作者 Y. Yildiz R. Karadag +1 位作者 M. Cordera B. Gensinger 《American Journal of Analytical Chemistry》 2020年第8期301-308,共8页
Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standard... Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standards. A number of analytical methods are presently used for the analysis of metals in the biochemical. The instrumental techniques available are Inductively Coupled Plasma (ICP/MS), X-Ray Fluorescence, UV-VIS Spectrophotometry, and Atomic Absorption Spectrometry. Flame AA has gained widespread acceptance as an analytical technique and is used for many applications. In this study, we have determined the amount of manganese metal present in Tricalcium Phosphate (TCP) using Flame Atomic Absorption Spectrophotometer. The method has high precision and accuracy. The percent recovery was found to be 99.8% for spiked sample. The results meet the requirement. 展开更多
关键词 Manganese Determination Tri Calcium Phosphate Flame atomic absorption spectrometry
下载PDF
Gold Determination by Electrothermal Atomic Absorption Spectrometry After Preconcentration Using Natural Deep Eutectic Solvent Based on Menthol and Camphor
20
作者 Valeriia Maksimova Varvara Lapina +2 位作者 Leonid Martynov Andrey Shishov Olga Mokhodoeva 《Journal of Analysis and Testing》 EI CSCD 2023年第4期435-443,共9页
A novel analytical procedure for the determination of gold by electrothermal atomic absorption spectrometry combined with selective liquid-liquid extraction by natural deep eutectic solvents(NADESs)is presented.The ex... A novel analytical procedure for the determination of gold by electrothermal atomic absorption spectrometry combined with selective liquid-liquid extraction by natural deep eutectic solvents(NADESs)is presented.The extraction ability of the NADESs prepared using menthol,thymol and camphor toward gold in hydrochloric acid solutions was studied.The extraction efficiency was improved by optimizing the parameters including the composition of the NADES s,the volume ratio of organic and aqueous phases,kinetics,and acidity of the solution.Quantitative determination of gold was carried out by electrothermal atomic absorption spectrometry directly in the NADES s phase dissolved in isopropyl alcohol.The extraction recovery of gold from 1 mol/L HCl with the NADESs based on menthol and camphor mixed in a molar ratio 1:1 was 99.7%at an enrichment factor of 100.The limits of detection and quantification of the proposed procedure were 1μg/L and 3.3μg/L,respectively,with a relative standard deviation of less than 5%.The developed procedure was applied for determination of gold in the certified reference material of ore,environmental and waste waters. 展开更多
关键词 Gold Liquid-liquid extraction Menthol/camphor Natural deep eutectic solvents(NADESs) Electrothermal atomic absorption spectrometry(ETAAS)
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部