期刊文献+
共找到5,109篇文章
< 1 2 250 >
每页显示 20 50 100
A dual-route optical emission spectroscopy diagnostic with wide spectral range and high wavelength resolution on HL-2A tokamak
1
作者 陈越 高继昆 +10 位作者 龙婷 聂林 高金明 马尧 黄渊 田文静 刘延民 朱晓东 庄革 钟武律 许敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期25-30,共6页
A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a be... A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density n_(e)and deuterium temperature T_(D) in the X-point multifaceted asymmetric radiation from the edge(MARFE)region are derived simultaneously by fitting the measured D_(a) shape.The density n_(e)is observed to increase from~8.7×10^(18)m^(-3)to~7.8×10^(19)m^(-3),and the temperature T_(D)drops from~14.4 eV to~2.3 eV after the onset of MARFE in the discharge#38260. 展开更多
关键词 optical emission spectroscopy Balmer series TOKAMAK
下载PDF
Diagnostics of laser-induced plasma on carbon-based polymer material using atomic and molecular emission spectra
2
作者 Jelena PETROVIC Dragan RANKOVIC +5 位作者 Miroslav KUZMANOVIC Jelena SAVOVIC Vasili KIRIS Alena NEVAR Mikhail NEDELKO Nikolai TARASENKO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第4期175-183,共9页
Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based... Time-integrated optical emission analysis of laser-induced plasma on Teflon is presented.Plasma was induced under atmospheric pressure air using transversely excited atmospheric CO_(2) laser pulses.Teflon is a C-based polymer that is,among other things,interesting as a substrate for laser-induced breakdown spectroscopy analysis of liquid samples.This study aimed to determine the optimal experimental conditions for obtaining neutral and ionized C spectral lines and C2 and CN molecular band emission suitable for spectrochemical purposes.Evaluation of plasma parameters was done using several spectroscopic techniques.Stark profiles of appropriate C ionic lines were used to determine electron number density.The ratio of the integral intensity of ionic-to-atomic C spectral lines was used to determine the ionization temperature.A spectral emission of C2 Swan and CN violet bands system was used to determine the temperature of the colder,peripheral parts of plasma.We critically analyzed the use of molecular emission bands as a tool for plasma diagnostics and suggested methods for possible improvements. 展开更多
关键词 spectroscopy of laser-induced plasma laser-induced breakdown spectroscopy transversely excited atmospheric CO_(2)laser plasma diagnostics atomic and molecular emission spectra TEFLON
下载PDF
Analysis of the injection layer of PTCDA in OLEDs using x-ray photoemission spectroscopy and atomic force microscopy 被引量:2
3
作者 欧谷平 宋珍 +2 位作者 吴有余 陈小强 张福甲 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第6期1296-1300,共5页
Through the investigation of the sample surface and interface of 3, 4, 9, 10-perylenetetracarboxylic dianhydride (PTCDA)/indium-tin-oxide (ITO) thin films using atomic force microscopy, it has been found that the ... Through the investigation of the sample surface and interface of 3, 4, 9, 10-perylenetetracarboxylic dianhydride (PTCDA)/indium-tin-oxide (ITO) thin films using atomic force microscopy, it has been found that the surface is complanate, the growth is uniform and the defects cover basically the surface of ITO. Furthermore, the number of pinholes is small. The analysis of the sample surface and interface further verifies this result by using x-ray photoemission spectroscopy. At the same time, PTCDA is found to have the ability of restraining the diffusion of chemical constituents from ITO to the hole transport layer, which is beneficial to the improvement of the performance and the useful lifetime of the organic light emitting diodes (OLEDs). 展开更多
关键词 atomic force microscopy x-ray photoemission spectroscopy PTCDA/ITO
下载PDF
Quantitative Determination of Density of Ground State Atomic Oxygen from Both TALIF and Emission Spectroscopy in Hot Air Plasma Generated by Microwave Resonant Cavity 被引量:1
4
作者 F.MARCHAL M.YOUSFI +2 位作者 N.MERBAHI G.WATTIEAUX A.PIQUEMAL 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第3期259-265,共7页
Two experimental techniques have been used to quantify the atomic oxygen density in the case of hot air plasma generated by a microwave (MW) resonant cavity. The latter operates at a frequency of 2.45 GHz inside a c... Two experimental techniques have been used to quantify the atomic oxygen density in the case of hot air plasma generated by a microwave (MW) resonant cavity. The latter operates at a frequency of 2.45 GHz inside a cell of gas conditioning at a pressure of 600 mbar, an injected air flow of 12 L/min and an input MW power of 1 kW. The first technique is based on the standard two photon absorption laser induced fluorescence (TALIF) using xenon for calibration but applied for the first time in the present post discharge hot air plasma column having a temperature of about 4500 K near the axis of the nozzle. The second diagnostic technique is an actinometry method based on optical emission spectroscopy (OES). In this case, we compared the spectra intensities of a specific atomic oxygen line (844 nm) and the closest wavelength xenon line (823 nm). The two lines need to be collected under absolutely the same spectroscopic parameters. The xenon emission is due to the addition of a small proportion of xenon (1% Xe) of this chemically inert gas inside the air while a further small quantity of H2 (2~) is also added in the mixture in order to collect OH(A- X) and NH(A-X) spectra without noise. The latter molecular spectra are required to estimate gas and excitation temperatures. Optical emission spectroscopy measurements, at for instance the position z=12 mm on the axis plasma column that leads to a gas measured temperature equal to 3500 K, an excitation temperature of about 9500 K and an atomic oxygen density 2.09× 1017+ 0.2×1017 cm-3. This is in very good agreement with the TALIF measurement, which is equal to 2.0×101T cm-3. 展开更多
关键词 TALIF microwave air plasma atomic oxygen concentration actinometry optical emission spectroscopy
下载PDF
Time-resolved measurement of atomic emission enhancement by fs-ns dual-pulsed laser-induced breakdown spectroscopy 被引量:1
5
作者 颜立新 张永生 +3 位作者 郑国鑫 刘晶儒 程建平 吕敏 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第10期2271-2274,共4页
Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG ... Time-resolved measurement of atomic emission enhancement is performed by using a 500-fs KrF laser pulse incident upon a high density supersonic O2 gas jet, synchronized with an orthogonal ns frequency-doubled Nd:YAG laser pulse. The ultra-short pulse serves as an igniter of the gas jet, and the subsequent ns-laser pulse significantly enhances the atomic emission. Analysis shows that the contributions to the enhancement effect are made mainly by the bremsstrahlung radiation and cascade ionization. 展开更多
关键词 time-resolved measurement atomic emission enhancement dual-pulse LIBS
下载PDF
Determination of Lead in Lime-preserved Egg by Microwave Digestion and Flame Atomic Absorption Spectroscopy
6
作者 Mimi ZHANG 《Asian Agricultural Research》 2023年第7期51-53,共3页
[Objectives] To establish a method for determining the lead content in lime-preserved eggs, to provide a theoretical basis for the quality control of production enterprises and the sampling and testing of supervision ... [Objectives] To establish a method for determining the lead content in lime-preserved eggs, to provide a theoretical basis for the quality control of production enterprises and the sampling and testing of supervision departments. [Methods] The lead content in lime-preserved eggs was measured by the microwave digestion and flame atomic absorption spectroscopy. [Results] The method had a correlation coefficient of r2=0.998 in the injection concentration range of 0-4 mg/L. The detection limit of the method was 0.008 2 mg/kg. In the range of 0.2 to 1.0 mg/kg addition concentration, the recovery rate of the method was 92.5%-108.0%, and the relative standard deviation(RSD) was <5%. [Conclusions] This method is accurate and reliable, simple and efficient, and is suitable for the detection of lead in lime-preserved eggs. 展开更多
关键词 Microwave Digestion Flame atomic absorption spectroscopy Lime-preserved eggs LEAD
下载PDF
A seven-crystal spectrometer for high-energy resolution X-ray spectroscopy at Shanghai Synchrotron Radiation Facility
7
作者 Bing-Bao Mei Liang-Xin Wang +6 位作者 Song-Qi Gu Xiao-Zhi Su Shuo Zhang Yao Wei Jing-Yuan Ma Zheng Jiang Fei Song 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第9期82-91,共10页
A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facili... A Johann-type X-ray spectrometer was successfully developed at the hard X-ray branch(in-vacuum undulator with a 24-mm periodic length)of the energy material beamline(E-line)at the Shanghai Synchrotron Radiation Facility(SSRF).This spectrometer was utilized to implement X-ray emission spectroscopy(XES),high-energy resolution fluorescence-detected X-ray absorption spectroscopy(HERFD-XAS),and resonant inelastic X-ray scattering.Seven spherically bent crystals were positioned on the respective vertical 500-mm-diameter Rowland circles,adopting an area detector to increase the solid angle to 1.75%of 4πsr,facilitating the study of low-concentrate systems under complex reaction conditions.Operated under the atmosphere pressure,the spectrometer covers the energy region from 3.5 to 18 keV,with the Bragg angle ranging from 73°to 86°during vertical scanning.It offers a promised energy resolution of sub-eV(XES)and super-eV(HERFD-XAS).Generally,these comprehensive core-level spectroscopy methods based on hard X-rays at the E-line with an extremely high photon flux can meet the crucial requirements of a green energy strategy.Moreover,they provide substantial support for scientific advances in fundamental research. 展开更多
关键词 X-ray emission spectroscopy High-energy-resolution X-ray spectrometer Johann geometry Energy materials SSRF
下载PDF
Control of Nickel Alloy Structural Change by the Atomic Emission Spectroscopy Method
8
作者 Nina Molchan Dmitriy Eliseev Valery Fertikov 《American Journal of Analytical Chemistry》 2016年第9期633-641,共9页
The aim of the work was the assessment of capability for the change control in the structure of a compact material of pelletized heatproof nickel alloy grade EP741NP using the atomic emission method. The proposed meth... The aim of the work was the assessment of capability for the change control in the structure of a compact material of pelletized heatproof nickel alloy grade EP741NP using the atomic emission method. The proposed method of evaluation is based on the statistical significance of the analytical response differences during atomic emission spectroscopy of solid specimens taken from one sample before and after heat treatment using the instruments AtomComp 81 and ARL 4460 with a high-voltage spark excitation. For calculations, the ratio of the line intensity of the analyzed element to the line intensity of the main sample component (in our case Ni<sub>2254</sub>) was used. The difference confidence estimation was made by the averages comparison method in a variance analysis. The study results are presented on the effect of material structure on analytical response during atomic emission spectroscopy of solid specimens. It was proved that the samples before and after heat treatment give statistically differing results while analyzed. 展开更多
关键词 atomic emission Spectral Analysis Pelletized Heatproof Nickel Alloy STRUCTURE
下载PDF
Plasma diagnostics by optical emission spectroscopy on manganese ore in conjunction with XRD, XRF and SEM-EDS 被引量:4
9
作者 Muhammad FAHAD Sajad ALI Yaseen IQBAL 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第8期103-110,共8页
Manganese(Mn) is an important industrial mineral.Information about the chemical and phase constitution along with the concentration of impurities presented in Mn ore is compulsory in assessing its suitability for diff... Manganese(Mn) is an important industrial mineral.Information about the chemical and phase constitution along with the concentration of impurities presented in Mn ore is compulsory in assessing its suitability for different applications.We performed the qualitative and quantitative analysis of low-grade Mn ore(LGMO) using laser-induced breakdown spectroscopy(LIBS) in conjunction with x-ray diffraction(XRD), x-ray fluorescence(XRF) and scanning electron microscopy(SEM) coupled with energy dispersive x-ray electron spectroscopy(EDS).The optical emission spectra of the LGMO sample displayed the presence of Mn, Si, Ca, Fe, Al, Mg,V, Ti, Sr, Ni, Na, Ba and Li.The plasma parameters, electron temperature and number density were estimated using the Boltzmann plot and Stark broadening line profile methods and were found to be 7500 K±750 K and 8.18±0.8×1017 cm-3, respectively.Quantitative analysis was performed using the calibration-free LIBS(CF-LIBS) method and its outcome along with XRD, XRF and SEM-EDS data showed almost analogous elemental composition, while the LIBS method gave acceptably precise elemental analysis by detecting the low atomic number element Li besides V and Sr.The results obtained using LIBS for the LGMO exhibited its ability as a powerful analytical tool and XRF, XRD and SEM-EDS as complementary methods for the compositional analysis of complex low-grade mineral ore. 展开更多
关键词 plasma diagnostic optical emission spectroscopy spectrochemical analysis LASER-INDUCED BREAKDOWN spectroscopy SEM-EDS
下载PDF
Study of spatial and temporal evolution of Ar and F atoms in SF6/Ar microsecond pulsed discharge by optical emission spectroscopy 被引量:4
10
作者 Hongyue LI Xingwei WU +5 位作者 Cong LI Yong WANG Ding WU Jiamin LIU Chunlei FENG Hongbin DING 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第7期69-76,共8页
The study of sulfur hexafluoride(SF6) discharge is vital for its application in gas-insulated equipment. Direct current partial discharge(PD) may cause SF6 decomposition, and the decomposed products of SF6, such as F ... The study of sulfur hexafluoride(SF6) discharge is vital for its application in gas-insulated equipment. Direct current partial discharge(PD) may cause SF6 decomposition, and the decomposed products of SF6, such as F atoms, play a dominant role in the breakdown of insulation systems. In this study, the PD caused by metal protrusion defects is simulated by a needle-plate electrode using pulsed high voltage in SF6/Ar mixtures. The spatial and temporal characteristics of SF6/Ar plasma are analyzed by measuring the emission spectra of F and Ar atoms, which are important for understanding the characteristics of PD. The spatial resolved results show that both F and Ar atom spectral intensities increase first from the plate anode to the needle and then decrease under the conditions of a background pressure of400 Pa, peak voltage of-1000 V, frequency of 2 kHz, pulse width of 60 μs, and electrode gap of 5-9 mm. However, the distribution characteristics of F and Ar are significantly different. The temporal distribution results show that the spectral intensity of Ar decreasesfirst and then increases slowly, while the spectral intensity of F increases slowly for the duration of the pulsed discharge at the electrode gap of 5 mm and the pulse width of40-80 μs. 展开更多
关键词 optical emission spectroscopy partial DISCHARGE SF6-insulated equipment SPATIAL and temporal evolution
下载PDF
Determination of vanadium in food and traditional Chinese medicine by graphite furnace atomic absorption spectroscopy 被引量:3
11
作者 ZOUMingqiang JIANGTiansu +1 位作者 WANGDaning ZHAIQingzhou 《Rare Metals》 SCIE EI CAS CSCD 2003年第1期14-18,共5页
Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions wher... Various experimental conditions were described for the vanadium determinationby graphite furnace atomic absorption spectroscopy (GFAAS). The experiments showed that whenatomization took place under the conditions where the combination of a pyrolytic coating graphitetube and fast raising temperature were used and the temperature was stable, the signal peak shapescould be improved, the sensitivity was enhanced, and the memory effect was removed. The vanadium infood and traditional Chinese medicinal herbs can be accurately determined using the standard curvemethod. 展开更多
关键词 vanadium determination graphite furnace atomic absorption spectroscopy(GFAAS) FOOD traditional Chinese medicinal herb
下载PDF
Langmuir Probe and Optical Emission Spectroscopy Studies of Low-Pressure Gas Mixture of CO_2 and N_2 被引量:2
12
作者 E.F.MENDEZ-MARTINEZ P.G.REYES +2 位作者 D.OSORIO-GONZALEZ F.CASTILLO H.MARTINEZ 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第3期314-319,共6页
Optical emission spectroscopy was used to study a gas mixture glow discharge of CO2 and N2 at a total pressure of 1.2 Torr, a power of 100 W and a flow of 16.5 L/min. The emission bands were measured in the wavelength... Optical emission spectroscopy was used to study a gas mixture glow discharge of CO2 and N2 at a total pressure of 1.2 Torr, a power of 100 W and a flow of 16.5 L/min. The emission bands were measured in the wavelength range of 200 nm to 900 nm. The principal species observed were O2^+ (A^2П→ X^2П), CO^+ (A^2П→X^2∑), N2^+ (B^2∑u+ → X^2∑g^+), CO2^+ (A^2∏ → X^2∏), N2(C^3∏u → B^3∏g), O2(b^1∑g^+→ X^3∑g^-), and CO (a^r3∑→a^3∏). The behavior of the band intensities as a function of the N2 percentage is consistent with recent Monte Carlo simulations. The electron temperature and ion density were determined by a double Langmuir probe. The electron temperature was found in the range of 1.55 eV to 2.93 eV, and the electron concentration in the order of 10^10 cm^-3. The electron temperature and ion density at pure N2 and pure CO2 agree with previous measurements. 展开更多
关键词 optical emission spectroscopy glow discharge electron temperature CO2 N2
下载PDF
Development of vacuum ultraviolet spectroscopy for measuring edge impurity emission in the EAST tokamak 被引量:4
13
作者 Hongming ZHANG Bo LYU +9 位作者 Liang HE Yongcai SHEN Jun CHEN Jia FU Bin BIN Xunyu WANG Fudi WANG Yingying LI Ling ZHANG Bing LIU 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第8期8-13,共6页
The dominant wavelength range of edge impurity emissions moves from the visible range to the vacuum ultraviolet(VUV)range,as heating power increasing in the Experimental Advanced Superconducting Tokamak(EAST).The meas... The dominant wavelength range of edge impurity emissions moves from the visible range to the vacuum ultraviolet(VUV)range,as heating power increasing in the Experimental Advanced Superconducting Tokamak(EAST).The measurement provided by the existing visible spectroscopies in EAST is not sufficient for impurity transport studies for high-parameters plasmas.Therefore,in this study,a VUV spectroscopy is newly developed to measure edge impurity emissions in EAST.One Seya-Namioka VUV spectrometer(McPherson 234/302)is used in the system,equipped with a concave-corrected holographic grating with groove density of 600 grooves mm-1.Impurity line emissions can be observed in the wavelength range ofλ=50-700 nm,covering VUV,near ultraviolet and visible ranges.The observed vertical range is Z=-350-350 mm.The minimum sampling time can be set to 5 ms under full vertical binning(FVB)mode.VUV spectroscopy has been used to measure the edge impurity emission for the 2019 EAST experimental campaign.Impurity spectra are identified for several impurity species,i.e.,lithium(Li),carbon(C),oxygen(O),and iron(Fe).Several candidates for tungsten(W)lines are also measured but their clear identification is very difficult due to a strong overlap with Fe lines.Time evolutions of impurity carbon emissions of CⅡat 134.5 nm and CⅢat 97.7 nm are analyzed to prove the system capability of time-resolved measurement.The measurements of the VUV spectroscopy are very helpful for edge impurity transport study in the high-parameters plasma in EAST. 展开更多
关键词 EAST TOKAMAK IMPURITY tungsten vacuum ULTRAVIOLET spectroscopy EDGE IMPURITY emission plasma diagnostics
下载PDF
The Study of the Impact of Mercury Sample Magnetization Prior to Detection by Emission Spectroscopy 被引量:1
14
作者 Wameath S. Abdul-Majeed William B. Zimmerman 《Journal of Environmental Science and Engineering(A)》 2012年第3期380-387,共8页
Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or... Experimental investigations were conducted in this study to explore the effect of magnetization on water sample properties and to envisage whether the effect is beneficial for mercury detection in a sample of water or not. Subjecting the water sample to 0.3 Tesla magnetic field for 14 hours led to instantaneous effects on the examined water properties, where a reduction in the values of pH (7%) and interfacial tension (0.2%) was observed, whereas an increase (8%) in water electrical conductivity was recorded. Similar behaviours with slight changes in trend were observed after storing the samples for six days, which indicates a creation of permanent effects. Other experiments were conducted to explore the impact of magnetizing water sample containing inorganic mercury prior to detection by emission spectroscopy. Samples were prepared with different mercury concentrations and derivatized by using tin chloride (SnCI2). The generated mercury vapour species were transported with aid of carrier gas into a dielectric barrier discharge plasma atomizer, in which the mercury signal at 253.65 nm was recorded. The results have shown 3.5%-7.5% increase in the signal intensities recorded for the magnetized samples, mostly attributed to a reduction in the sample surface tension and other reasons, which facilitates analyte derivatization. 展开更多
关键词 Water magnetization DBD plasma atomic emission spectroscopy heavy metals.
下载PDF
Analysis of Aluminum Dust Cloud Combustion Using Flame Emission Spectroscopy 被引量:1
15
作者 Sanghyup Lee Kwanyoung Noh Woongsup Yoon 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2015年第9期2431-2438,共8页
In this study,aluminum flame analysis was researched in order to develop a measurement method for high-energy-density metal aluminum dust cloud combustion,and the flame temperature and UV-VIS-IR emission spectra were ... In this study,aluminum flame analysis was researched in order to develop a measurement method for high-energy-density metal aluminum dust cloud combustion,and the flame temperature and UV-VIS-IR emission spectra were precisely measured using a spectrometer.Because the micron-sized aluminum flame temperature was higher than 2 400 K,Flame temperature was measured by a non-contact optical technique,namely,a modified two-color method using 520 and 640nm light,as well as by apolychromatic fitting method.These methods were applied experimentally after accurate calibration.The flame temperature was identified to be higher than 2 400 Kusing both methods.By analyzing the emission spectra,we could identify AlO radicals,which occur dominantly in aluminum combustion.This study paves the way for realization of a measurement technique for aluminum dust cloud combustion flames,and it will be applied in the aluminum combustors that are in development for military purposes. 展开更多
关键词 ALUMINUM COMBUSTION FLAME characteristics High-temperature measurement emission spectroscopy DIAGNOSTICS
下载PDF
Determination of trace elements in maifanite by outer cover electrode atomic emission spectrometry 被引量:1
16
作者 LIJianqiang LUYiqiang JIANGWei 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期161-165,共5页
Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer ... Maifanite is a nature medicinal stone used in many fields for long time. Theresearch on it showed that there are many trace elements in maifanite. In this paper, 36 traceelements in maifanite were determined by outer cover electrode atomic emission spectrometry, and thedetermination conditions were studied systematically. The results show that the concentrations ofelements, which are beneficial to human health, are higher, and the elements harmful to peoplehealth such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy werealso discussed. 展开更多
关键词 atomic emission spectrometry outer cover electrode DETERMINATION TRACEELEMENTS maifanite
下载PDF
Novel infrared differential optical absorption spectroscopy remote sensing system to measure carbon dioxide emission 被引量:1
17
作者 Ru-Wen Wang Pin-Hua Xie +1 位作者 Jin Xu Ang Li 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第1期353-359,共7页
A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The ... A CO_2 infrared remote sensing system based on the algorithm of weighting function modified differential optical absorption spectroscopy(WFM-DOAS) is developed for measuring CO_2 emissions from pollution sources. The system is composed of a spectrometer with band from 900 nm to 1700 nm, a telescope with a field of view of 1.12?, a silica optical fiber, an automatic position adjuster, and the data acquisition and processing module. The performance is discussed,including the electronic noise of the charge-coupled device(CCD), the spectral shift, and detection limits. The resolution of the spectrometer is 0.4 nm, the detection limit is 8.5 × 10^(20)molecules·cm^(-2), and the relative retrieval error is < 1.5%.On May 26, 2018, a field experiment was performed to measure CO_2 emissions from the Feng-tai power plant, and a twodimensional distribution of CO_2 from the plume was obtained. The retrieved differential slant column densities(dSCDs)of CO_2 are around 2 × 10^(21) molecules·cm^(-2) in the unpolluted areas, 5.5 × 10^(21)molecules·cm^(-2) in the plume locations most strongly affected by local CO_2 emissions, and the fitting error is less than 2 × 10^(20)molecules·cm^(-2), which proves that the infrared remote sensing system has the characteristics of fast response and high precision, suitable for measuring CO_2 emission from the sources. 展开更多
关键词 weighting function modified DIFFERENTIAL optical ABSORPTION spectroscopy(WFM-DOAS) INFRARED instrument CO2 emission SOURCES
下载PDF
Investigation on plasma characteristics in a laser ablation pulsed plasma thruster by optical emission spectroscopy 被引量:2
18
作者 Yu ZHANG Jianjun WU +2 位作者 Yang OU Daixian ZHANG Jian LI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第4期83-89,共7页
In order to further improve the propulsion performance of pulsed plasma thrusters for space micro propulsion,a novel laser ablation pulsed plasma thruster is proposed,which separated the laser ablation and electromagn... In order to further improve the propulsion performance of pulsed plasma thrusters for space micro propulsion,a novel laser ablation pulsed plasma thruster is proposed,which separated the laser ablation and electromagnetic acceleration.Optical emission spectroscopy is utilized to investigate the plasma characteristics in the thruster.The spectral lines at different times,positions and discharge intensities are experimentally recorded,and the plasma characteristics in the discharge channel are concluded through analyzing the variation of spectral lines.With the discharge energy of 24 J,laser energy of 0.6 J and the use of aluminum propellant,the specific impulse and thrust efficiency reach 6808 s and 70.6%,respectively. 展开更多
关键词 laser ablation PULSED PLASMA THRUSTER optical emission spectroscopy PLASMA PROPULSION performance
下载PDF
Time-Resolved Optical Emission Spectroscopy Diagnosis of CO_2 Laser-Produced SnO_2 Plasma 被引量:1
19
作者 兰慧 王新兵 左都罗 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第9期902-906,共5页
The spectral emission and plasma parameters of SnO2 plasmas have been investigated. A planar ceramic SnO2 target was irradiated by a CO2 laser with a full width at half maximmn of 80 ns. The temporal behavior of the s... The spectral emission and plasma parameters of SnO2 plasmas have been investigated. A planar ceramic SnO2 target was irradiated by a CO2 laser with a full width at half maximmn of 80 ns. The temporal behavior of the specific emission lines from the SnO2 plasma was characterized. The intensities of Sn I and Sn Ⅱ lines first increased, and then decreased with the delay time. The results also showed a faster decay of Sn I atoms than that of Sn II ionic species. The temporal evolutions of the SnO2 plasma parameters (electron temperature and density) were deduced. The measured temperature and density of SnO2 plasma are 4.38 eV to 0.5 eV and 11.38×1017 cm 3 to 1.1×1017^ cm-3, for delay times between 0.1 μs and 2.2 #s. We also investigated the effect of the laser pulse energy on Sn02 plasma. 展开更多
关键词 optical emission spectroscopy laser produced plasma C02 laser electrontemperature electron density
下载PDF
Determination of Non-Maxwellian Electron Energy Distributions in Low-Pressure Plasmas by Using the Optical Emission Spectroscopy and a Collisional-Radiative Model 被引量:1
20
作者 朱悉铭 蒲以康 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第3期267-278,共12页
A Maxwellian electron energy distribution function (EEDF) is often assumed when using the optical emission line-ratio method to determine the electron temperature in low- temperature plasmas. However, in many cases,... A Maxwellian electron energy distribution function (EEDF) is often assumed when using the optical emission line-ratio method to determine the electron temperature in low- temperature plasmas. However, in many cases, non-Maxwellian EEDFs can be formed due to the non-local electron heating or the inelastic-collisional energy loss processes. In this work, with a collisional-radiative model, we propose an approach to obtain the non-Maxwellian EEDF with a 'two-temperature structure' from the emission line-ratios of Paschen 2p levels of argon and kryp- ton atoms. For applications of this approach in reactive gas (CF4, O2, etc) discharges that contain argon and krypton, recommendations of some specific emission line-ratios are provided, according to their sensitivities to the EEDF variation. The kinetic processes of the relevant excited atoms are also discussed in detail. 展开更多
关键词 plasma diagnostics optical emission spectroscopy non-Maxwellian EEDF collisional-radiative model
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部