期刊文献+
共找到1,896篇文章
< 1 2 95 >
每页显示 20 50 100
Modified Maze lines plus pulmonary vein isolation created by radiofrequency catheter ablation on the atrial wall to treat atrial fibrillation in elderly 被引量:1
1
作者 Caiyi LU Shiwen WANG Xinping DU Yinglong HOU Qiao XUE Xinli WU Rui CHEN Peng LIU 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2005年第2期95-100,共6页
Objective To evaluate the effect of modified Maze lines plus pulmonary vein (PV) isolation created by radiofrequency catheter ablation (RFCA) on atrial wall guided by a novel geometry mapping system in the treatment o... Objective To evaluate the effect of modified Maze lines plus pulmonary vein (PV) isolation created by radiofrequency catheter ablation (RFCA) on atrial wall guided by a novel geometry mapping system in the treatment of elderly patients with paroxysmal atrial fibrillation (PAF). Methods After regular electrophysiological study, transseptal punctures were achieved twice with Swartz L1 and R1 sheaths. PV angiographies were conducted to evaluate their orifices and branches. A balloon electrode array catheter with 64 electrodes was put in the middle of the left atrium. Atrium geometry was constructed using Ensite 3000 Navx system. Two RFCA lesion loops and three lines (modified Maze) were created on left and right atrial walls. Each lesion point was ablated for 30 seconds with preset temperature 50 (ae) and energy 30W. The disappearance or 80% decrease of the amplitude of target atrial potential and 10 to 20(|), decrease of ablation impedance were used as an index of effective ablation. Results A total of 11 patients (7 male and 4 female, mean age, 68.7±5.1 years) were enrolled. PAF history was 7.9±4.5 years. PAF could not be prevented by mean 3.1±1.6 antiarrhythmic agents in 6.3±3.4 years. None of the patients had complications with structural heart disease or stroke. Left atrial diameter was 41.3±3.6 mm and LVEF was 59.2±3.7% on echocardiography. Two loops and three lines were completed with 67.8±13.1 (73-167) lesion points. Altogether 76-168 (89.4±15.3) lesion points were created in each patient. PAF could not be provoked by rapid burst pacing up to 600 beat per minute delivered from paroxysmal coronary sinus electrode pair.Complete PV electrical isolation was confirmed by three-dimensional activation mapping. Mean procedure time was 2.7±0.6 hours and fluoroscopy time was 17.8±9.4 minutes. Patients were discharged with oral aspirin and without antiarrhythmic agents. During follow up of 6.5±1.8 months, seven patients were PAF symptom free (63.6%). PAF attacks were decreased more than 70% in two patients (18.2%). PAF frequency did not change in another two patients (18.2%). Conclusions Ensite 3000 Navx guided modified Maze lines plus PV isolation on the atrial wall is safe and feasible in the elderly patients. It has the advantages of exact procedural endpoint, shorter X-ray exposure, fewer complications and satisfied long-term effect PAF control. 展开更多
关键词 PAROXYSMAL atrial fibrillation ELECTROPHYSIOLOGY MAZE ablation pulmonary vein ablation
下载PDF
Reversal of pulmonary vein remodeling after catheter ablation of atrial fibrillation
2
作者 Jia-Hui WU Hung-Kei LI +5 位作者 Daniel M Couri Philip A Araoz Ying-Hsiang Lee Chang-Sheng MA Douglas L Packer Yong-Mei CHA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第2期163-168,共6页
Background Pulmonary veins (PV) and the atria undergo electrical and structural remodeling in atrial fibrillation (AF). This study aimed to determine PV and left atrial (LA) reverse remodeling after catheter abl... Background Pulmonary veins (PV) and the atria undergo electrical and structural remodeling in atrial fibrillation (AF). This study aimed to determine PV and left atrial (LA) reverse remodeling after catheter ablation for AF assessed by chest computed tomography (CT). Methods PV electrophysiologic studies and catheter ablation were performed in 63 patients (68% male; mean ± SD age: 56 ± 10 years) with symptomatic AF (49% paroxysmal, 51% persistent). Chest CT was performed before and 3 months after catheter ablation. Results At baseline, patients with persistent AF had a greater LA volume (91 ±29 cm3 vs. 66 ± 27 cm3; P = 0.003) and mean PV ostial area (241 + 43 mm2 vs. 212 ± 47 mm2; P = 0.03) than patients with paroxysmal AF. There was no significant correlation between the effective refractory period and the area of the left superior PV ostium. At 3 months of follow-up after ablation, 48 patients (76%) were AF free on or off antiarrhythmic drugs. There was a significant reduction in LA volume (77 ±31 cm3 to 70 ± 28 cm3; P 〈 0.001) and mean PV ostial area (224 ± 48 mm2 to 182 ± 43 mm2; P 〈 0.001). Patients with persistent AF had more reduction in LA volume (11.8 ± 12.8 cm3 vs. 4.0 ± 11.2 cm3; P = 0.04) and PV ostial area (62 mm2 vs. 34 mm2; P = 0.04) than those who have paroxysmal AF. The reduction of the averaged PV ostial area was significantly correlated with the reduction of LA volume (r = 0.38, P = 0.03). Conclusions Catheter ablation of AF improves structural remodeling ofPV ostia and left atrium. This finding is more apparent in patients with persistent AF treated by catheter ablation. 展开更多
关键词 ablation atrial fibrillation Computed tomography Left atrium pulmonary vein isolation pulmonary vein ostial area
下载PDF
Radiofrequency Ablation Mapping with Circumferential Catheter for Paroxys- mal Atrial Fibrillation Originating From the Pulmonary Veins
3
作者 刘震 吴书林 +5 位作者 杨平珍 方咸宏 李海杰 陈泗林 詹贤章 薛玉梅 《South China Journal of Cardiology》 CAS 2002年第2期72-76,共5页
Objectives To assessed the feasibility and effectiveness of electrophysiological mapping of pulmonary veins with a circumferential 10 - electrode catheter and radiofrequency catheter ablation therapy for patients with... Objectives To assessed the feasibility and effectiveness of electrophysiological mapping of pulmonary veins with a circumferential 10 - electrode catheter and radiofrequency catheter ablation therapy for patients with paroxysmal atrial fibrillation. Background Standard mapping and ablation of focal sources of atrial fibrillation are associated with very long procedure times and low efficacy. Mapping and ablation pulmonary veins guide with a circular catheter could overcome these limitations. Methods 16 patients [male 11, female 5, mean age (51 ±14. 5) years] with paroxysmal atrial fibrillation refractory to antiarrhythmic drugs were included in this group. A circumferential 10 - electrode catheter was used to pulmonary vein mapping during sinus rhythm or CSd pacing to determine the origin of atrial premature contractions. When the ablative target pulmonary vein was found, the pulmonary vein potentials' distribution and activation were assessment pulmonary veins' ostial ablation was performed at the segments showing earliest activation of pulmonary vein potentials. The end point was designed: 1) elimination of pulmonary vein potential; 2) pulmonary vein potential dissociation from atrial waves; 3) atrial ectopic beats disappear. Results A total of 36 pulmonary veins were ablated, including 16 left superior, 12 right superior, 7 left inferior and 1 right inferior. 1 pulmonary vein in 2 patients was ablated, 2 pulmonary veins in 8 patients were ablated, 3 pulmonary veins were ablated in 5 patients and 4 pulmonary veins were ablated in 1 pa- tient. Procedure duration and fluoroscopy time respectively were 186. 7±63. 8 min and 51. 5±15. 0 min. During the follow-up 1-12 months, 11 patients (68. 7 % ) were free of AF without any antiarrhythmic drugs, 2 of them were reablation, effective in 3/16 (18. 7 % ) and unsuccessful in 2/16 (12. 6 % ) . 2 cases recurred with atrial premature, 1 was treated with amiodarone and the other was repeat electrophysiologi-cal mapping and ablation, 5 cases with paroxysmal a-trial fibrillation recurred, 3 of them were treated with amiodarone (2 cases) or sotalol (1 case) , one was implantled with DDDR pacemaker (having programmer of anti - atrial fibrillation), one was repeat ablation. PV's diameter in 2 of them reduced more than 50 % , but they were asymptomatic during the follow - up period. 1 case had pneumothorax complication and disappeared after 7 days. Conclusions This study suggests that careful mapping and elimination of these ectopic foci under the guide of circular catheter may have higher success rate and splendid future. 展开更多
关键词 atrial fibrillation pulmonary vein catheter ablation
下载PDF
Removal of a pulmonary artery foreign body during pulse ablation in a patient with atrial fibrillation:A case report
4
作者 Rui Yan Xin-Yu Lei +2 位作者 Jun Li Liang-Liang Jia Hai-Xiong Wang 《World Journal of Clinical Cases》 SCIE 2023年第27期6587-6591,共5页
BACKGROUND Foreign bodies in the pulmonary circulation have been documented in the literature and are typically caused by interventional procedures.However,reports of pulmonary artery foreign bodies during femoral vei... BACKGROUND Foreign bodies in the pulmonary circulation have been documented in the literature and are typically caused by interventional procedures.However,reports of pulmonary artery foreign bodies during femoral vein puncture are rare,and there is no description of this complication from the guidewire surface flows into the pulmonary artery during a pulse ablation in a patient with atrial fibrillation.CASE SUMMARY We described a case in which a linear foreign body suddenly appeared on fluoroscopy image during pulsed ablation of atrial fibrillation.Multiposition angiography showed that the foreign body was currently lodged in the pulmonary artery but was hemodynamically stable.We then chose to use an interventional approach to remove the foreign body from the pulmonary artery.This foreign body was subsequently confirmed to be from the hydrophilic coating of the guidewire surface.This may be related to the difficulties encountered during the puncture of the femoral vein.This is a rare and serious complication of femoral vein puncture.Therefore,we reported this case in order to avoid a similar situation.CONCLUSION Mismatches between interventional devices from different manufacturers used for femoral venipuncture may result in pulmonary artery foreign bodies. 展开更多
关键词 Femoral vein puncture atrial fibrillation Guide wire COMPLICATION pulmonary artery foreign body Case report
下载PDF
Segmental radiofrequency ablation of pulmonary vein ostia for patients with refractory paroxysmal atrial fibrillation using multi-slice spiral computed tomography guidance 被引量:6
5
作者 JIANG Chen-yang(蒋晨阳) +7 位作者 WANG Jian-an(王建安) HE Hong(何红) SUN Yong(孙勇) ZHOU Bin-quan(周斌全) 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2005年第12期1153-1156,共4页
Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral ... Objective: To evaluate the safety and clinical efficacy of segmental radiofrequency ablation of pulmonary vein (PV) ostia for patients with refractory paroxysmal atrial fibrillation (AF) under multi-slice spiral computed tomography (MSCT) guidance before the procedure. Methods: A series of 58 consecutive patients with refractory paroxysmal AF were enrolled to undergo segmental radiofrequency ablation ofPV ostia. The 36 male and 22 female patients with mean age of (57.4±9.5) (32-79) years and no obvious organic heart disease. Before ablation, patients received MSCT to generate 3-dimentional image of the left atrium (LA) and proximal PVs. Patients then underwent segmental radiofrequency ablation ofPV ostia using PV circular mapping catheter manipulated several times to ensure complete isolation between PVs and LA. Results: No complications occurred during the procedure. One patient developed delayed cardiac tamponade, which was drained percutaneously. The mean follow-up time was (17.1±9.3) months. Forty-one patients (95%) experienced improved quality of life one month after the procedure. Thirty-six patients (83%) showed stable sinus rhythm, while 10 patients (23%) required additional anti-arrhythmic drugs. AF returned≥1 time in 6 (14%) patients who underwent anti-arrhythmic drug therapy, but the number of episodes was less than that before the procedure. However, one patient experienced recurrent episodes of atrial flutter. Conclusion: It is safe and effective to perform segmental radiofrequency ablation of PV ostia for patients with refractory paroxysmal AF using MSCT guidance mappening. 展开更多
关键词 atrial fibrillation pulmonary vein Radiofrequency ablation Multi-slice spiral computed tomography
下载PDF
Impact of Pulmonary Vein Anatomy on Long-term Outcome of Cryoballoon Ablation for Atrial Fibrillation 被引量:4
6
作者 Shang-wei HUANG Qi JIN +6 位作者 Ning ZHANG Tian-you LING Wen-qi PAN Chang-jian LIN Qing-zhi LUO Yan-xin HAN Li-qun WU 《Current Medical Science》 SCIE CAS 2018年第2期259-267,共9页
Variant pulmonary vein anatomy (PVA) has been reported to influence the recurrence of atrial fibrillation (AF) after radiofrequency ablation. However, the effects of PVA on AF in patients undergoing cryoballoon ab... Variant pulmonary vein anatomy (PVA) has been reported to influence the recurrence of atrial fibrillation (AF) after radiofrequency ablation. However, the effects of PVA on AF in patients undergoing cryoballoon ablation (CBA) remain unknown. The present study aimed to examine the impact of PVA on the long-term outcome of CBA for AF. A total of 78 patients (mean age 60.7±10.9 years, 64.1% males) with symptomatic and drug-refractory paroxysmal AF were enrolled in the study. Left atrium (LA) and PVA acquired at computed tomography angiography (CTA) were reconstructed with CARTO 3 SYSTEM. Patients were routinely evaluated by 24-hour Holter monitoring following CBA. Cox regression was used to detect the predictors of AF recurrence after CBA. The results showed abnormal PVA in 30 patients (38.5%) and 18 patients (23.1%) had left common PV (LCPV). Electrical pulmonary vein isolation was achieved in all patients. After a mean follow-up of 689.5±103.8 days, it was found that patients with abnormal PVA had similar AF recurrence rate to those with normal PVA (26.7% vs. 25.0%, P=0.54), and there was no significant difference in AF recurrence rate between LCPV patients and non-LCPV patients (33.7% vs. 23.3%, P=0.29). Cox regression analysis showed that AF duration (72.9±9.0 vs. 42.3±43.2 months, HR 1.001; 95%CI 1.003- 1.014; P〈0.001) and cryo-applications of right-side PVs (3.0±1.6 vs. 4.7±1.7, HR 0.661; 95% CI 0.473-0.925; P=0.016) were independent predictors of freedom from AF, but PVA was not identified as a predictor of long-term success. In conclusion, the variant PVA cannot significantly influence the long-term outcome of AF patients undergoing CBA; longer AF duration and less cryo-applications of right-side PVs are associated with higher AF recurrent rate. 展开更多
关键词 atrial fibrillation pulmonary vein ANATOMY cryoballoon ablation
下载PDF
Hemoptysis secondary to pulmonary vein stenosis after radiofrequency ablation for atrial fibrillation: A case report and literature review 被引量:2
7
作者 Zhiming Xuan Boyu Liu +2 位作者 Minjun Ci Zhe Wang Yong Fan 《Journal of Interventional Medicine》 2020年第2期98-100,共3页
Objectives: Pulmonary vein stenosis(PVS) is a known complication after radiofrequency ablation of atrial fibrillation(RAAF) and is often misdiagnosed owing to lack of awareness regarding PVS among noncardiologists.Mis... Objectives: Pulmonary vein stenosis(PVS) is a known complication after radiofrequency ablation of atrial fibrillation(RAAF) and is often misdiagnosed owing to lack of awareness regarding PVS among noncardiologists.Misdiagnosis results in unnecessary treatment;therefore, greater understanding of PVS can improve the management of these patients.Methods: We report the case of a 38-year-old man with a history of RAAF who presented with massive hemoptysis.His symptoms persisted despite undergoing transcatheter bronchial artery embolization on two occasions.Results: Pulmonary computed tomography angiography revealed a completely occluded left superior pulmonary vein. Considering the patient’s history of RAAF, we diagnosed him with RAAF-induced PVS and performed left superior lobectomy after which hemoptysis did not recur.Conclusions: Unexplained massive hemoptysis should alert clinicians regarding the possibility of RAAF-induced PVS. Balloon angioplasty and stent placement are used to treat PVS;however, their efficacy is controversial considering the high recurrence rates associated with these interventions. 展开更多
关键词 HEMOPTYSIS pulmonary vein Radiofrequency ablation atrial fibrillation
下载PDF
Paroxysmal atrial fibrillation ablation:Achieving permanent pulmonary vein isolation by point-by-point radiofrequency lesions
8
作者 Alonso Pedrote Juan Acosta +2 位作者 Beatriz Jáuregui-Garrido Manuel Frutos-López Eduardo Arana-Rueda 《World Journal of Cardiology》 CAS 2017年第3期230-240,共11页
Pulmonary vein isolation by point-by-point radiofrequency catheter ablation constitutes the cornerstone of catheter ablation strategies for the treatment of atrial fibrillation. However, despite advances in pulmonary ... Pulmonary vein isolation by point-by-point radiofrequency catheter ablation constitutes the cornerstone of catheter ablation strategies for the treatment of atrial fibrillation. However, despite advances in pulmonary vein isolation ablation strategies, long-term success rates after ablation remain suboptimal, which highlights the need to develop techniques to achieve more durable lesions. Strategies proposed to improve the durability of pulmonary vein isolation can be divided into two groups: Those addressed to improving the quality of the lesion and those that optimize the detection of acute PV reconnection during the ablation procedure. This manuscript reviews the role and potential benefits of these techniques according to current clinical evidence. 展开更多
关键词 atrial fibrillation pulmonary vein isolation Lesion durability Contact force pulmonary vein reconnection
下载PDF
Ultrasound ablation of pulmonary veins for treatment of paroxysmal atrial fibrillation
9
作者 王建安 孙勇 何红 《Journal of Zhejiang University Science》 CSCD 2003年第6期745-748,共4页
Objective : to evaluate the efficacy and safety of ultrasound ablation of pulmonary veins for treatment of paroxysmal atrial fibrillation. Methods : The study population consisted of 9 patients with 5 males and 4 fem... Objective : to evaluate the efficacy and safety of ultrasound ablation of pulmonary veins for treatment of paroxysmal atrial fibrillation. Methods : The study population consisted of 9 patients with 5 males and 4 females enrolled consecutively who had idiopathic paroxysmal atrial fibrillation(AF) . The ultrasound balloon was positioned through a special sheath to the orifice of the target vein by a transseptal procedure. The balloon was inflated with contrast-mixed saline (contrast: saline = 1:4) whose volume was decided by the diameter of the target pulmonary vein. The ablation energy was usually set up at 35 to 40 watts with temperature controlled at 60℃ . The duration of each ablation was about 120 seconds which was repeated not over 10 times. Results: The average duration of the total procedure was 132± 68 min for our patients. The average fluoroscopy time was 33 ±17 min. With a mean follow-up of 16 ±8 months after the procedure, AF was completely eliminated in 4 patients without antiarrhythmic drugs. The episodes of atrial fibrillation were eliminated in 2 patients with low dosage of oral amiodarone (0.1, once daily) which was ineffective before the procedure. The frequency of episodes was similar to that before the procedure in 3 patients. There were no complications such as hemopericardium, air embolism and stenosis of the pulmonary veins by angiography, related to the procedure. Conclusion : Ultrasound ablation of the pulmonary veins is a new approach to treat paroxysmal atrial fibrillation. Before we determined its value, we need to do more researches with bigger sample, randomization and comparison design. 展开更多
关键词 Ultrasound ablation Paroxysmal atrial fibrillation Pulminary veins
下载PDF
Design and Baseline Patient Characteristics of the Prospective, Observational, Multicenter and Multinational Cohort Study Comparing Radiofrequency with Cryoablation for Pulmonary Vein Isolation in Patients with Atrial Fibrillation—The Freeze Cohort Study
10
作者 Ellen Hoffmann Uwe Dorwarth +13 位作者 Karl Heinz Kuck Jürgen Vogt Malte Kuniss Steffen Schneider Jürgen Tebbenjohanns Kyong Ryul Julian Chun Dietrich Andresen Stefan Spitzer Thorsten Lewalter Stephan Willems Johannes Brachmann Christoph Stellbrink Bernhard Rauch Jochen Senges 《International Journal of Clinical Medicine》 2014年第19期1161-1172,共12页
Aims: The FREEZE-cohort study (NCT 01360008) is a prospective observational, multicenter and multinational study to evaluate safety and effectiveness of cryoballoon ablation for pulmonary vein isolation as compared to... Aims: The FREEZE-cohort study (NCT 01360008) is a prospective observational, multicenter and multinational study to evaluate safety and effectiveness of cryoballoon ablation for pulmonary vein isolation as compared to radiofrequency ablation in patients with paroxysmal or persistent atrial fibrillation (lasting < one year) under the conditions of clinical routine. Methods and Results: The study started in 2011 and anticipates inclusion up to 2000 patients in each of the two treatment groups. A total of 37 centers from 8 countries worldwide, all experienced in at least one of the two ablation techniques, participate in the study. The primary outcome parameter of the study is defined as atrial fibrillation recurrence rate during twelve months of follow-up. Secondary outcome parameters include primary success rates, complication rates in general, specific complications with respect to phrenic nerve palsy and pulmonary vein stenosis, radiation exposure, clinical course including death and repeat ablation. Finally specific procedural aspects will be evaluated in a descriptive manner. Preliminary data of the first 1882 patients show that in clinical practice cryoablation is preferentially performed in patients with paroxysmal atrial fibrillation, whereas application of radiofrequency ablation is equally distributed between patients with persistent and paroxysmal atrial fibrillation. Conclusion: Based on multi-center and multi-national data the FREEZE-cohort study will provide important information on long-term efficacy, clinical effectiveness, complication rates and procedural differences between atrial fibrillation patients treated with either cryoablation or radiofrequency ablation. 展开更多
关键词 atrial fibrillation catheter ablation CRYOBALLOON ablation RADIOFREQUENCY ablation REGISTRY
下载PDF
Mechanisms and clinical significance of early recurrences of atrial arrhythmias after catheter ablation for atrial fibrillation 被引量:18
11
作者 Jackson J Liang Sanjay Dixit Pasquale Santangeli 《World Journal of Cardiology》 CAS 2016年第11期638-646,共9页
Early recurrence of atrial arrhythmias(ERAA) after ablation is common and strongly predicts late recurrences and ablation failure. However, since arrhythmia may eventually resolve in up to half of patients with ERAA, ... Early recurrence of atrial arrhythmias(ERAA) after ablation is common and strongly predicts late recurrences and ablation failure. However, since arrhythmia may eventually resolve in up to half of patients with ERAA, guidelines do not recommend immediate reintervention for ERAA episodes occurring during a 3-mo postablation blanking period. Certain clinical demographic, electrophysiologic, procedural, and ERAA-related characteristics may predict a higher likelihood of longterm ablation failure. In this review, we aim to discuss potential mechanisms of ERAA, and to summarize the clinical significance, prognostic implications, and treatment options for ERAA. 展开更多
关键词 atrial fibrillation RECURRENCE catheter ablation pulmonary vein isolation
下载PDF
Catheter ablation of atrial fibrillation in elderly population 被引量:10
12
作者 Josef Kautzner Petr Peichl +3 位作者 Marek Sramko Robert Cihak Bashar Aldhoon Dan Wichterle 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2017年第9期563-568,共6页
Background Although elderly patients have been included in published series of catheter ablation for atrial fibrillation (AF), clinicalbenefit and safety remain still less defined in this population. A retrospective... Background Although elderly patients have been included in published series of catheter ablation for atrial fibrillation (AF), clinicalbenefit and safety remain still less defined in this population. A retrospective analysis of the results of catheter ablation for AF in a large volumecenter focused on comparison of elderly patients with the rest of the patient cohort was conducted in this study. Methods Consecutive patientswho underwent catheter ablation for AF between January 2001 and December 2016 were analysed. A total population of 3197 patients wasdichotomized by the age of 70 years (394 elderly vs. 2803 younger subjects). Patients were followed in terms of arrhythmia status and sur-vival for a median period of 18 vs. 21 and 35 vs. 57 months, respectively. Results Elderly patients were more frequently females (49% vs.29%, P 〈 0.0001), had a history of hypertension (79% vs. 57%, P 〈 0.0001), diabetes (16% vs. 11%, P 〈 0.01), stroke (9% vs. 6%, P 〈 0.01),coronary/peripheral artery disease (14% vs. 8%, P 〈 0.0001), and CHAzDS2-VASc score (3.1 ± 1.3 vs. 1.5 ± 1.2 s, P 〈 0.0001). Major com-plications were more frequent in elderly (5.3% vs. 3.2%, P = 0.03); however, this difference was driven by vascular complications (3.6% vs.1.9%, P = 0.04). There were comparable rates of cerebrovascular (0.3 vs. 0.3%) or nonvascular complications (1.8 vs. 1.2%). Good arrhyth-mia control was inferior in elderly patients as compared with the rest of the cohort, both without and with antiarrhythmic drugs: 44.2% vs.58.2% (P 〈 0.0001) and 78.2 vs. 83.2% (P 〈 0.01), respectively. Poor arrhythmia control was associated with relative risk of all-cause mor-tality of 2.7 (95% CI: 1.1-6.4) in elderly patients and 1.4 (95% CI: 0.9-2.0) in younger subjects. Conclusions Catheter ablation for AF inelderly patients is safe although somewhat less effective. Good arrhythmia control is associated with better survival, especially in elderly patients. 展开更多
关键词 atrial fibrillation catheter ablation COMPLICATIONS The ELDERLY
下载PDF
Clinical outcomes of radiofrequency catheter ablation of atrial fibrillation in octogenarians lO-year experience of a one high-volume center 被引量:6
13
作者 Alan Bulava Jiri Hanis Ladislav Dusek 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2017年第9期575-581,共7页
Background Prevalence of atrial fibrillation (AF) increases with age. Radiofrequency catheter ablation (RFCA) is an establishedtreatment option superior to antiarrhythmics (AAs). In this study, we investigated s... Background Prevalence of atrial fibrillation (AF) increases with age. Radiofrequency catheter ablation (RFCA) is an establishedtreatment option superior to antiarrhythmics (AAs). In this study, we investigated safety and efficacy of RFCA of AF in octogenarians.Methods From our database, we extracted procedural and follow-up data for patients 〉 80 years with symptomatic AF undergoing RFCAand compared this population to RFCA patients 〈 50 years. All patients underwent pulmonary vein isolation (PVI) supplemented by linearlesions in PVI-nonresponders. Arrhythmia-free survival was assessed using seven day Holter every three months post procedure. All patientscompleted their 12 months follow-up. Results Fifty patients aged ≥80 years (80.5 ± 1.6 years) were compared to 259 patients aged 〈 50years (43.5±5.5 years). The RFCA complication rate did not vary between groups. No differences in procedural characteristics were seenafter being analyzed by type of AF. Among patients with paroxysmal AF, 71.4% octogenarian vs. 84.7% young patients was free of anyarrhythmia, without AAs, after single procedure. For non-paroxysmal AF, arrhythmia-free survival without AAs, was considerably lower(58.6% octogenarians vs. 81.2% younger patients, P = 0.023). If AAs were used, arrhythmia-free survival for paroxysmal AF increased to90.5% and 92.1% in octogenarians and younger patients, respectively; and in non-paroxysmal AF it increased to 79.3% vs. 88.4%. ConclusionsRFCA is a safe and effective strategy to achieve normal sinus rhythm in a highly selected group of octogenarians. Paroxysmal AF ablation inoctogenarians has similar clinical effectiveness as that seen in much younger patients. Non-paroxysmal AF ablation has lower, but still rea-sonable clinical effectiveness. 展开更多
关键词 atrial fibrillation catheter ablation Effectiveness OCTOGENARIANS Safety The ELDERLY
下载PDF
Value of cystatin C in predicting atrial fibrillation recurrence after radiofrequency catheter ablation 被引量:4
14
作者 Li-Li JIN Ling YOU Rui-Qin XIE 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第12期725-731,共7页
Backgroud Recent studies have demonstrated that cystatin C is a valuable risk marker for cardiovascular disease morbidity and mortality.Therefore,we hypothesized that the pre-ablation cystatin C level was associated w... Backgroud Recent studies have demonstrated that cystatin C is a valuable risk marker for cardiovascular disease morbidity and mortality.Therefore,we hypothesized that the pre-ablation cystatin C level was associated with post-ablation atrial fibrillation(AF)recurrence.Methods 207 patients were enrolled and completed in this prospective observational study.Patients with AF scheduled for receive radiofrequency catheter ablation(RFCA)therapy were screened for the study.Before ablation therapy,electrocardiogram,24 h holter monitor,transesophageal echocardiography,serum cystatin C,high-sensitivity C-reactive protein,creatinine levels,and routine blood examinations were examined.After ablation,patients were followed up every week for the first month,and then at 2,3,6,9,and 12 months.Thereafter,patients came back to out-patient clinic every six months regularly.Electrocardiogram or 24 h holter monitor were repeated if the patient experienced palpitations or every six months.AF recurrence was defined as atrial flbrillation/atrial flutter or atrial tachycardia lasting≥30 seconds within three months after therapy.Results Compared to patients with no AF recurrence,patients with recurrence had longer AF history(P=0.007),more early recurrence(P=0.000),a larger left atrium(P=0.004),and higher pre-ablation cystatin C levels(P=0.000).Multivariate regression analysis revealed that cystatin C and left atria(LA)diameter were risk factors for AF recurrence.After adjusting for LA diameter,the risk of AF recurrence increased 30%with every milligram cystatin C elevation(95%CI:1.117-1.523).Conclusions Pre-ablation cystatin C levels were associated with AF recurrence after RFCA therapy,an optimal cut-off value of 1.190 mg/L(sensitivity=0.576;specificity=0.851). 展开更多
关键词 atrial fibrillation catheter ablation CYSTATIN C RECURRENCE
下载PDF
Catheter ablation for atrial fibrillation is associated with reduced risk of mortality in the elderly:a prospective cohort study and propensity score analysis 被引量:5
15
作者 Xin SU Xin DU +13 位作者 Shang-Xin LU Chao JIANG Jing DU Shi-Jun XIA Zhao-Jie DONG Zhao-Xu JIA De-Yong LONG Cai-Hua SANG Ri-Bo TANG Nian LIU Song-Nan LI Rong BAI Jian-Zeng DONG Chang-Sheng MA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第12期740-749,共10页
Background It is unclear whether catheter ablation(CA)for atrial fibrillation(AF)affects the long-term prognosis in the elderly.This study aims to evaluate the relationship between CA and long-term outcomes in elderly... Background It is unclear whether catheter ablation(CA)for atrial fibrillation(AF)affects the long-term prognosis in the elderly.This study aims to evaluate the relationship between CA and long-term outcomes in elderly patients with AF.Methods Patients more than 75 years old with non-valvular AF were prospectively enrolled between August 2011 and December 2017 in the Chinese Atrial Fibrillation Registry Study.Participants who underwent CA at baseline were propensity score matched(1:1)with those who did not receive CA.The outcome events included all-cause mortality,cardiovascular mortality,stroke/transient ischemic attack(TIA),and cardiovascular hospitalization.Results Overall,this cohort included 571 ablated patients and 571 non-ablated patients with similar characteristics on 18 dimensions.During a mean follow-up of 39.75±19.98 months(minimum six months),24 patients died in the ablation group,compared with 60 deaths in the non-ablation group[hazard ratio(HR)=0.49,95%confidence interval(CI):0.30-0.79,P=0.0024].Besides,6 ablated and 29 non-ablated subjects died of cardiovascular disease(HR=0.25,95%CI:0.11-0.61,P=0.0022).A total of 27 ablated and 40 non-ablated patients suffered stroke/TIA(HR=0.79,95%CI:0.48-1.28,P=0.3431).In addition,140 ablated and 194 non-ablated participants suffered cardiovascular hospitalization(HR=0.84,95%CI:0.67-1.04,P=0.1084).Subgroup analyses according to gender,type of AF,time since onset of AF,and anticoagulants exposure in initiation did not show significant heterogeneity.Conclusions In elderly patients with AF,CA may be associated with a lower incidence of all-cause and cardiovascular mortality. 展开更多
关键词 atrial fibrillation catheter ablation MORTALITY STROKE The elderly
下载PDF
Long-term results of single-procedure catheter ablation for atrial fibrillationin pre-and post-menopausal women 被引量:5
16
作者 Tao LIN Xing DU Rong BAI Ying-Wei CHEN Rong-Hui YU De-Yong LONG Ri-Bo TANG Cai-Hua SANG Song-Nan LI Chang-Sheng MA Jian-Zeng DONG 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2014年第2期120-125,共6页
Objectives To address whether menopause affects outcome of catheter ablation (CA) for atrial fibrillation (AF) by comparing the safety and long-term outcome of a single-procedure in pre-and post-menopausal women. ... Objectives To address whether menopause affects outcome of catheter ablation (CA) for atrial fibrillation (AF) by comparing the safety and long-term outcome of a single-procedure in pre-and post-menopausal women. Methods A total of 743 female patients who underwent a single CA procedure of drug-refractory AF were retrospectively analyzed. The differences in clinical presentation and outcomes of CA for AF between the pre-menopausal women (PreM group, 94 patients, 12.7%) and the post-menopausal women (PostM group, 649 patients, 87.3%) were assessed. Results The patients in the PreM group were younger (P&lt;0.001) and less likely to have hypertension (P&lt;0.001) and diabetes (P=0.005) than those in the PostM group. The two groups were similar with regards to the proportion of concomitant mitral valve regurgitation coronary artery disease, left atrium dimensions, and left ventricular ejection fraction. The overall rate of complica-tions related to AF ablation was similar in both groups (P=0.385). After 43 (16-108) months of follow-up, the success rate of ablation was 54.3%in the PreM group and 54.2%in the PostM group (P=0.842). The overall freedom from atrial tachyarrhythmia recurrence was simi-lar in both groups. Menopause was not found to be an independent predictive factor of the recurrence of atrial tachyarrhythmia. Conclusions The long-term outcomes of single-procedure CA for AF are similar in pre-and post-menopausal women. Results indicated that CA of AF appears to be as safe and effective in pre-menopausal women as in post-menopausal women. 展开更多
关键词 atrial fibrillation catheter ablation FOLLOW-UP Menopausal woman
下载PDF
Catheter ablation of atrial fibrillation: Radiofrequency catheter ablation for redo procedures after cryoablation 被引量:2
17
作者 Klaus Kettering Felix Gramley 《World Journal of Cardiology》 CAS 2013年第8期280-287,共8页
AIM: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation.METHODS: Thirty patients(paroxysmal atrial fibrillati... AIM: To evaluate the effectiveness of two different strategies using radiofrequency catheter ablation for redo procedures after cryoablation of atrial fibrillation.METHODS: Thirty patients(paroxysmal atrial fibrillation: 22 patients,persistent atrial fibrillation: 8 patients) had to undergo a redo procedure after initially successful circumferential pulmonary vein(PV) isolation with the cryoballoon technique(Arctic Front Balloon,CryoCath Technologies/Medtronic).The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy(CARTO;Biosense Webster) depending on the intra-procedural findings.After discharge,patients were scheduled for repeated visits at the arrhythmia clinic.A 7-day Holter monitoring was performed at 3,12 and 24 mo after the ablation procedure.RESULTS: During the redo procedure,a mean number of 2.9 re-conducting pulmonary veins(SD ± 1.0 PVs) were detected(using a circular mapping catheter).In 20 patients,a segmental approach was sufficient to eliminate the residual pulmonary vein conduction because there were only a few recovered pulmonary vein fibres.In the remaining 10 patients,a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction.All recovered pulmonary veins could be isolated successfully again.At 2-year follow-up,73.3% of all patients were free from an arrhythmia recurrence(22/30).There were no major complications.CONCLUSION: In patients with an initial circumferential pulmonary vein isolation using the cryoballoon technique,a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation. 展开更多
关键词 atrial fibrillation catheter ablation CRYOablation pulmonary veinS SUPRAVENTRICULAR ARRHYTHMIAS
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
18
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 pulmonary veins catheter ablation atrial fibrillation Transesophageal echocardiography Three-dimensional echocardiography
下载PDF
Pulmonary vein isolation implemented by second-generation cryoballoon for treating hypertrophic cardiomyopathy patients with symptomatic atrial fibrillation:a case-control study 被引量:3
19
作者 Zhong-Jing CAO Xiao-Gang GUO +4 位作者 Qi SUN Jian-Du YANG Hui-Qiang WEI Shu ZHANG Jian MA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第8期476-485,共10页
Background Atrial fibrillation(AF)is a generally acknowledged turning-point of the natural history of hypertrophic cardiomyopathy(HCM);however,data from the cryoballoon ablation(CBA)for AF in HCM patients are relative... Background Atrial fibrillation(AF)is a generally acknowledged turning-point of the natural history of hypertrophic cardiomyopathy(HCM);however,data from the cryoballoon ablation(CBA)for AF in HCM patients are relatively scarce.The study aimed to evaluate the efficacy and safety of CBA in HCM patients with AF.Methods We retrospectively analyzed HCM patients among 1253 patients with symptomatic AF who underwent CBA for pulmonary vein isolation in a single center.The study analyzed the AF recurrence and assessed the CBA indexes,including nadir temperature,time-to-isolation,CBA failure,pulmonary vein potentials(PVPs),and redo procedure.Results A total of 108 patients were included(mean age:59.0±6.9 years),27 patients(25%)had HCM,with the median follow-up duration of 25.5 months.The one-year AF-free rates were 79.0%vs.63.0%(non-HCM vs.HCM),while the two-year AF-free rates were 77.8%vs.55.1%[hazard ratio(HR)=2.758,log-rank P=0.024].Patients with persistent AF had poor AF-free rates compared to those with paroxysmal AF(P<0.001).The CBA failure was the most common in the right inferior pulmonary veins,which had the lowest PVPs.Multivariate Cox regression analysis indicated that HCM and persistent AF were risk factors for AF recurrence(HR=2.74,95%CI:1.29–5.79,P=0.008;and HR=3.97,95%CI:1.85–8.54,P<0.001,respectively).Conclusions The CBA can be effectively and safely used to treat HCM patients with symptomatic AF.The freedom from AF for HCM patients after CBA is relatively low compared to that for non-HCM patients. 展开更多
关键词 atrial fibrillation Cryoballoon ablation Hypertrophic cardiomyopathy pulmonary vein isolation
下载PDF
Impact of computed tomography image and contact force technology on catheter ablation for atrial fibrillation 被引量:1
20
作者 Ibrahim Marai Mahmoud Suleiman +3 位作者 Miry Blich Jonathan Lessick Sobhi Abadi Monther Boulos 《World Journal of Cardiology》 CAS 2016年第4期317-322,共6页
AIM:To investigate the impact of using computed tomography(CT) and contact force(CF) technology on recurrence of atrial tachyarrhythmia after atrial fibrillation(AF) ablation.METHODS: This non-randomized study include... AIM:To investigate the impact of using computed tomography(CT) and contact force(CF) technology on recurrence of atrial tachyarrhythmia after atrial fibrillation(AF) ablation.METHODS: This non-randomized study included 2 groups of patients. All patients had symptomatic recurrent paroxysmal or persistent AF and were treated with at least 1 anti arrhythmic medication or intolerant to medication. The first group included 33 patients who underwent circumferential pulmonary veins isolation(PVI) for AF during 2012 and 2013 guided by CT image integration(Cartomerge, Biosense Webster, Diamond Bar, CA, United States) of left atrium and pulmonary veins into an electroanatomic mapping(EAM) system(CT group) using standard irrigated radiofrequency catheter(Thermo Cool, Carto, Biosense Webster, Diamond Bar, CA, United States) or irrigated catheter with integrated CF sensor(Smart Touch, Carto, Biosense Webster, Diamond Bar, CA, United States). The second group included immediately preceding 32 patients who had circumferential PVI by standard irrigated catheter(Thermo Cool) using only EAM(Carto) system(EAM group). Linear lesions were performed according to the discretion of operator. RESULTS: Sex, age, and persistent AF were not different between groups. PVI was achieved in all patients in both groups. Linear ablations including cavo-tricuspid isthmus and or roof line ablation were not different between groups. Free of atrial tachyarrhythmia during follow-up of 24 mo was significantly higher among CT group compared to EAM group(81% vs 55%; respectively; P = 0.027). When 11 patients from CT group who had ablation using Smart Touch catheter were excluded, the difference between CT group and EAM became non significant(73% vs 55%; respectively; P = 0.16). Sub analysis of CT group showed that patients who had ablation using Smart Touch catheter tend to be more free of atrial tachyarrhythmia compared to patients who had ablation using standard irrigated catheter during follow-up(100% vs 73%; respectively; P = 0.07). Major complications(pericardial effusion, cerebrovascular accident/transient ischemic attack, vascular access injury requiring intervention) did not occurred in both groups.CONCLUSION:These preliminary results suggest that CT image integration and CF technology may reduce the recurrence of atrial tachyarrhythmia after catheter ablation for AF. 展开更多
关键词 atrial fibrillation catheter ablation IMAGE integration Contact force
下载PDF
上一页 1 2 95 下一页 到第
使用帮助 返回顶部