期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Characteristics of K_d (490) around Nansha Islands in the South China Sea
1
作者 张清凌 陈楚群 +1 位作者 施平 殷克东 《Marine Science Bulletin》 CAS 2004年第1期9-17,共9页
The diffusion attenuation coefficient for downwelling irradiance, Kd (490), is an important optical parameter of seawater. The optical property, Kd (490), around Nansha Islands in the South China Sea was analyzed base... The diffusion attenuation coefficient for downwelling irradiance, Kd (490), is an important optical parameter of seawater. The optical property, Kd (490), around Nansha Islands in the South China Sea was analyzed based on optical data profiles measured with SPMR ( SeaWiFS Profiling Multichannel Radiometer ) and SMSR ( SeaWiFS Multichannel Surface Reference ) instrument in April and May, 1999. The results show that Kd (490) is closely correlated with chlorophyll-a concentration, Cchl.a, and that the vertical distribution of Kd (490) shows the strong stratification of the water column in this area. Kd (490) has a similar vertical co-variation as KL (490), the diffusive attenuation coefficient for upwelling radiance. Both coefficients increase with depth in the upper layer, where KL (490) is greater than Kd (490); and after a depth, approximatively at the chlorophyll maximum, they decrease with depth, with the former being smaller than the latter. 展开更多
关键词 South China Sea Nansha Islands diffusion attenuation coefficient Kd (490) underwater spectral measurement
下载PDF
Measurement errors of ultrasonic velocity and attenuation due to nonparallelness of specimen faces
2
作者 WEI Tingcun(Department of Electrical Engineering, Tohoku University Japan) 《Chinese Journal of Acoustics》 2003年第2期113-120,共8页
The measurement errors due to nonparallelness of specimen faces in the ultrasonic velocity and attenuation coefficient measured by the pulse reflection method in VHF range have been investigated theoretically, and the... The measurement errors due to nonparallelness of specimen faces in the ultrasonic velocity and attenuation coefficient measured by the pulse reflection method in VHF range have been investigated theoretically, and the theoretical expressions for estimating these measurement errors are given. It has also been shown that, the attenuation coefficient error is depending on both the nonparallelness angle of specimen faces and the ultrasonic frequency, but the velocity error is only depending on the former. Furthermore, for pure silica glass specimen it is estimated that, in VHF range in order to insure that the attenuation coefficient and velocity errors due to nonparallelness of specimen faces are less than 10% and 0.01%, respectively, the nonparallelness angle of specimen faces must be less than 10 s and 40 s correspondingly. 展开更多
关键词 of on IT AS Measurement errors of ultrasonic velocity and attenuation due to nonparallelness of specimen faces that IS
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部