Objective To compare the long-term clinical effects of two kinds of crowns and bridges made of porcelain fused to Au-Pt alloy and Ni-Cr alloy. Methods A total of 131 teeth (64 patients) were rehabilitated using porcel...Objective To compare the long-term clinical effects of two kinds of crowns and bridges made of porcelain fused to Au-Pt alloy and Ni-Cr alloy. Methods A total of 131 teeth (64 patients) were rehabilitated using porcelain-fused-to-metal crowns, among which 59 were rehabilitated with Au-Pt alloy metal ceramic crown and 72 with Ni-Cr alloy metal ceramic crown. The porcelain fracture, shade, marginal adaptation, gingival discoloration, and gingival status after finishing restoration and 36 months of follow-up were evaluated. Results After 36 months of restoration, porcelain fused to Au-Pt alloy crown showed better clinical effects than porcelain fused to Ni-Cr alloy crown in shade, marginal adaptation, gingival discoloration, as well as gingival status (all P<0.05). Conclusion The Au-Pt alloy ceramic crown is superior to Ni-Cr alloy ceramic crown in long-term clinical effects.展开更多
The Au-Pt alloy nanoparticles(Au-PtNPs) were electrochemically deposited on the surface of polyaniline nanotube(nanoPAN) and chitosan(CS) modified glassy carbon electrode(GCE). The electrochemical behavior of ...The Au-Pt alloy nanoparticles(Au-PtNPs) were electrochemically deposited on the surface of polyaniline nanotube(nanoPAN) and chitosan(CS) modified glassy carbon electrode(GCE). The electrochemical behavior of lincomycin at Au-PtNPs/nanoPAN/CS modified GCE was investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Cyclic voltammetric experiments show that lincomycin at the nanocomposite membrane modified electrode exhibited a pair of quasi-reversible redox peaks in pH=6.0 PBS. The membrane could accelerate the electron transfer of lincomycin on the electrode and significantly enhance the peak current. In a range of 3.0-100.0 mg/L, the reductive peak current of lincomycin at 0.42 V was linearly related to its concentration and the linear regression equation was ip,c=0.2703ρ-0.0042(ip, c: μA; ρ: mg/L; r=0.998, n=7) with a detection limit of 1.0 mg/L(S/N =3). Compared with other methods, this method exhibited many advantages such as high sensitivity, selectivity, wide linear range and low detection limit. The method was used to determine the content of lincomycin in injections commercially available with satisfactory results. Some electrochemical parameters involved in the redox reaction of lincomycin, such as parameter of kinetic ha, standard rate constant ks and the number of H^+, were also calculated.展开更多
文摘Objective To compare the long-term clinical effects of two kinds of crowns and bridges made of porcelain fused to Au-Pt alloy and Ni-Cr alloy. Methods A total of 131 teeth (64 patients) were rehabilitated using porcelain-fused-to-metal crowns, among which 59 were rehabilitated with Au-Pt alloy metal ceramic crown and 72 with Ni-Cr alloy metal ceramic crown. The porcelain fracture, shade, marginal adaptation, gingival discoloration, and gingival status after finishing restoration and 36 months of follow-up were evaluated. Results After 36 months of restoration, porcelain fused to Au-Pt alloy crown showed better clinical effects than porcelain fused to Ni-Cr alloy crown in shade, marginal adaptation, gingival discoloration, as well as gingival status (all P<0.05). Conclusion The Au-Pt alloy ceramic crown is superior to Ni-Cr alloy ceramic crown in long-term clinical effects.
基金Supported by the National Natural Science Foundation of China(Nos.20635020 and 20805025)Doctorial Foundation of the Ministry of Education of China(No.20060426001) Doctorial Fund of Qingdao University of Science and Technology, China(No.0022278)
文摘The Au-Pt alloy nanoparticles(Au-PtNPs) were electrochemically deposited on the surface of polyaniline nanotube(nanoPAN) and chitosan(CS) modified glassy carbon electrode(GCE). The electrochemical behavior of lincomycin at Au-PtNPs/nanoPAN/CS modified GCE was investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Cyclic voltammetric experiments show that lincomycin at the nanocomposite membrane modified electrode exhibited a pair of quasi-reversible redox peaks in pH=6.0 PBS. The membrane could accelerate the electron transfer of lincomycin on the electrode and significantly enhance the peak current. In a range of 3.0-100.0 mg/L, the reductive peak current of lincomycin at 0.42 V was linearly related to its concentration and the linear regression equation was ip,c=0.2703ρ-0.0042(ip, c: μA; ρ: mg/L; r=0.998, n=7) with a detection limit of 1.0 mg/L(S/N =3). Compared with other methods, this method exhibited many advantages such as high sensitivity, selectivity, wide linear range and low detection limit. The method was used to determine the content of lincomycin in injections commercially available with satisfactory results. Some electrochemical parameters involved in the redox reaction of lincomycin, such as parameter of kinetic ha, standard rate constant ks and the number of H^+, were also calculated.