AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy...AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy(CRT)design versus those employing the vision shaping treatment(VST)design.METHODS:This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years.A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses:CRT,Euclid,and Mouldway.The study’s primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.RESULTS:In the 3-year follow-up,the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group,0.59±0.37 mm in the Euclid lens group,and 0.63±0.38 mm in the Mouldway lens group.A noteworthy disparity emerged between the CRT and Mouldway groups(P<0.01),as well as between the CRT and Euclid groups(P<0.001).Additionally,it was observed that 32.1%of participants who wore CRT lenses experienced a decelerated progression of myopia,in contrast to 47.2%in the Euclid group and 44.4%in the Mouldway group.Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups(P<0.01),and similarly,the CRT group demonstrated a statistically significant difference when compared to the Mouldway group(P<0.05).CONCLUSION:Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia.In contradistinction to ortho-k lenses utilizing the CRT design,those employing the VST design exhibited a more favorable impact regarding retarding AL elongation.展开更多
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc...AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.展开更多
AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.M...AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice.展开更多
AIM:To determine the normative distribution of axial length(AL),anterior chamber depth(ACD),anterior chamber volume(ACV),anterior chamber angle(ACA),and some of their associated factors in subjects aged 60 and over.ME...AIM:To determine the normative distribution of axial length(AL),anterior chamber depth(ACD),anterior chamber volume(ACV),anterior chamber angle(ACA),and some of their associated factors in subjects aged 60 and over.METHODS:In this cross-sectional study,160 clusters were sampled using multi-stage cluster sampling in Tehran,Iran.After a preliminary interview,the participants underwent optometric examinations including visual acuity and refraction measurement followed by slit lamp biomicroscopy.Finally,ocular imaging was done using the Pentacam AXL to measure AL,ACD,ACV,and ACA.RESULTS:A total of 4519 eyes of 2436 participants were evaluated,of whom 58.0%(n=1412)were female.The mean age of the subjects was 67.32±6.05y(range:60-95y).The mean AL,ACD,ACV,and ACA was 23.22 mm(23.18-23.27 mm),2.61 mm(2.59-2.62 mm),126.56 mm3(125.08-128.04 mm3),and 30.61°(30.3°-30.92°),respectively.In the multivariable model,after adjusting for the effect of both eyes,the longest and shortest AL was seen in myopic and hyperopic subjects,respectively.AL,ACD,ACV and ACA were significantly larger in men compared to women(P<0.001).Except ACA,other evaluated parameters showed an inverse correlation with age(P<0.001),however,this correlation was insignificant for AL(P=0.623).CONCLUSION:Normative value of AL,and other biometric parameters are specific for each ethnicity,age and sex group.Any alteration in these parameters and their effect on refraction should be considered in this age group,especially in case of cataract surgery.展开更多
AIM:To report the myopia-controlling effect of repeated low-level red-light(RLRL)therapy in patients with Stickler syndrome(STL),an inherited collagenic disease typically presenting with early onset myopia.METHODS:Thr...AIM:To report the myopia-controlling effect of repeated low-level red-light(RLRL)therapy in patients with Stickler syndrome(STL),an inherited collagenic disease typically presenting with early onset myopia.METHODS:Three STL children,aged 3,7,and 11y,received RLRL therapy throughout the follow-up period of 17,3,and 6mo,respectively after exclusion of fundus anomalies.Data on best-corrected visual acuity(BCVA),intraocular pressure,cycloplegic subjective refraction,ocular biometrics,scanning laser ophthalmoscope,optical coherence tomography,genetic testing,systemic disease history,and family history were recorded.RESULTS:At the initiation of the RLRL therapy,the spherical equivalent(SE)of 6 eyes from 3 patients ranged from-3.75 to-20.38 D,axial length(AL)were from 23.88 to 30.68 mm,and BCVA were from 0.4 to 1.0(decimal notation).Myopia progression of all six eyes slowed down after RLRL therapy.AL in five out of the six eyes shortened-0.07 to-0.63 mm.No side effects were observed.CONCLUSION:Three cases of STL whose progression of myopic shift and AL elongation are successfully reduced and even reversed after RLRL therapy.展开更多
AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHOD...AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan.展开更多
AIM: To study ocular axial lengths in pediatric subjects without intraocular pathology. METHODS: An Institutional Review Board-approved consecutive retrospective chart review of axial lengths measured in pediatric sub...AIM: To study ocular axial lengths in pediatric subjects without intraocular pathology. METHODS: An Institutional Review Board-approved consecutive retrospective chart review of axial lengths measured in pediatric subjects who underwent examination under anesthesia due to positive family history of retinoblastoma or other inherited ocular disease. Only subjects without any intraocular pathology in either eye were included. Subjects were stratified into age groups. An axial length model using a logarithmic regression algorithm was calculated.RESULTS: Data from 330 eyes of 165 subjects were included in the study. The mean age at the time of examination was 30.62(SD 18.04)mo. The steepest increase in axial length was present during the first 10 mo of life. After 36 mo, there was no statistically significant axial length growth. CONCLUSION: This study presents the biggest series of pediatric axial lengths in healthy eyes. The axial length model developed with these data may assist in the diagnosis and management of a wide variety of pediatric ophthalmic diseases.展开更多
AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairme...AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairment screening of 3 to 4 y kindergarten students.METHODS: Between April and June 2017, a total of 4350 participants aged 3-to 4-year-old(8700 eyes) from 10 cluster random sampling kindergartens in Shanghai, Pudong District were involved. According to the measurement and analysis of the unaided visual acuity(VA), AL, CRC, AL/CRC ratio, astigmatism and other refractive parameters, the data distribution and reference range were obtained.RESULTS: Uncorrected VA of examined children was 0.23±0.08(logMAR, mean±SD) [95% confidence interval(CI) range ≤0.36];AL was 22.10±0.79 mm(95%CI 20.55-23.65);CRC was 7.86±0.26 mm(95%CI, 7.35-8.37);AL/CRC ratio was 2.81±0.12(95%CI, 2.57-3.05). The median of astigmatism was-0.5 D, a total of 56.3% had astigmatism <-0.50 D, 85.3%<-1.00 D, 6.7%>-1.50 D;71% were astigmatism with the rule. Eye-specific analyses were conducted. Statistical difference of VA was in right and left eyes. There were no significant differences between two eyes of AL, CRC, AL/CRC ratio and astigmatism(P>0.05).CONCLUSION: VA and AL/CRC ratio reference could be used to assess refractive development in children and screening uncorrected refractive errors or amblyopia. Astigmatism needs to be considered in the diagnosis.展开更多
AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were include...AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed.展开更多
AIM:To explore the photopic pupil size behavior in myopic children undergoing overnight orthokeratology(ortho-k)over 1-year period and its effects on the axial elongation.METHODS:A total of 202 Chinese myopic children...AIM:To explore the photopic pupil size behavior in myopic children undergoing overnight orthokeratology(ortho-k)over 1-year period and its effects on the axial elongation.METHODS:A total of 202 Chinese myopic children were enrolled in this prospective clinical trial.Ninetyfive subjects in ortho-k group and eighty-eight subjects in spectacle group completed the 1-year study.Axial length(AL)was measured before enrollment and every 6mo after the start of ortho-k.The photopic pupil diameter(PPD)was determined using the Pentacam AXL and measured in an examination room with lighting of 300-310 Lx.Stepwise multiple linear regression analysis was used to identify variables contribution to axial elongation.RESULTS:Compared with spectacle group,the average 1-year axial elongation was significantly slower in the ortho-k group(0.25±0.27 vs 0.44±0.23 mm,P<0.0001).In ortho-k group,PPDs significantly decreased from 4.21±0.62 mm to 3.94±0.53 mm after 1mo of lens wear(P=0.001,Bonferroni correction)and the change lasts for 3-month visit.No significantly change during the other follow-up visits was found(P>0.05,Bonferroni correction).The 4.81 mm PPD may be a possible cutoff point in the ortho-k group.Subjects with PPD below or equal to 4.81 mm tended to have smaller axial elongation compared to subjects with PPD above 4.81 mm after 1-year period(t=-3.09,P=0.003).In ortho-k group,univariate analyses indicated that those with older age,greater degree of myopia,longer AL,smaller baseline PPD(PPDbaseline)experienced a smaller change in AL.In multivariate analyses,older age,greater AL and smaller PPDbaseline were associated with smaller increases in AL.In spectacle group,PPD tended to be stable(P>0.05,Bonferroni correction)and did not affect axial growth.CONCLUSION:PPDs experience significantly decreases at 1-month and 3-month ortho-k treatment.Children with smaller PPD tend to experience slower axial elongation and may benefit more from ortho-k.展开更多
AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in ...AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.展开更多
The theoretical results of axial force distribution models differ greatly from tests because of the complication of the rock type material. A three-parameter combined-power model is proposed by curves fitting the test...The theoretical results of axial force distribution models differ greatly from tests because of the complication of the rock type material. A three-parameter combined-power model is proposed by curves fitting the test data recorded from the pull tests on anchoring bars used in different engineering projects. Based on the comparison of the mechanical characteristics of shaft anchors and prestressed tendons, a two-parameter combined-power function model for prestressed tendons is proposed. The bounded length derived from the model and the suggested values of the parameters are also proposed. Compared with the Gaussian model, the three-parameter combined-power model is more precise and simple in expression. Results also suggest that the bounded length calculated from the average stress method is not safe enough.展开更多
AIM:To evaluate the effect of axial length(AL)and anterior chamber depth(ACD)on peripheral refractive profile in myopic patients compared to emmetropic participants.METHODS:This cross-sectional study was conducted in ...AIM:To evaluate the effect of axial length(AL)and anterior chamber depth(ACD)on peripheral refractive profile in myopic patients compared to emmetropic participants.METHODS:This cross-sectional study was conducted in right eyes of 58 participants of whom 38 were emmetropic and 20 were myopic.Central and peripheral refraction were measured at 10°,20°,and 30°eccentricities in nasal and temporal fields using an open-field autorefractor.The Lenstar LS900 was used to measure ACD and AL.The participants were divided into three groups of short(<22.5 mm),normal(22.5-24.5 mm),and long eye(>24.5 mm)according to AL and three groups of low ACD(<3.00 mm),normal ACD(3.00-3.60 mm),and high ACD(>3.60 mm)according to ACD.RESULTS:The mean age of the participants was 22.26±3.09 y(range 18-30 y).The peripheral mean spherical refractive error showed a hypermetropic shift in myopic and emmetropic groups although this shift was more pronounced in the myopic group.The results showed significant changes in the spherical equivalent,J0,and J45 astigmatism in all gazes with an increase in eccentricity(P<0.001).The pattern of refractive error changes was more noticeable in long and short eyes versus normal AL eyes.Moreover,the pattern of peripheral refractive changes was much more prominent in the high ACD group versus the normal ACD group and in the normal ACD group versus the low ACD group.CONCLUSION:Peripheral refraction changes are greater in participants with AL values outside the normal range and deeper ACD values compared to participants with normal AL and ACD.展开更多
Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However...Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However,when compared with the eyes of normal children,the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus,assessment methods,and statistical outcome,making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed.The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists,with the hope of offering assistance that will enhance long-term therapeutic effects for these children.展开更多
AIM:To investigate the association of axial length(AL),lens thickness(LT),and lens vault(LV)with postoperative anterior chamber angle metrics after laser peripheral iridotomy(LPI).METHODS:Prospective observational stu...AIM:To investigate the association of axial length(AL),lens thickness(LT),and lens vault(LV)with postoperative anterior chamber angle metrics after laser peripheral iridotomy(LPI).METHODS:Prospective observational study of 69 patients(97 eyes)were diagnosed as primary angle-closure suspect(PACS),primary angle closure(PAC)or primary angle-closure glaucoma(PACG).AL,LT,anterior central chamber depth(ACD),angle opening distance(AOD),trabecular iris angle(TIA),and angle recess area(ARA)were measured before and 1 wk after LPI.The association between AL,LT,LV with ACD,AOD,TIA,ARA were analyzed by comparing the differences between preoperative and postoperative measurements for anterior segment biometric parameters.RESULTS:ACD,AOD,TIA,and ARA were significantly increased after LPI(all P<0.05).Greater LT was significantly associated with greater postoperative increases in ACD,AOD,TIA,and ARA(all P<0.05).AL was not significantly associated with changes of anterior segment biometric parameters.Greater LV was significantly associated with greater postoperative increases in ACD,AOD,and TIA(all P<0.05),but was not significantly associated with changes of ARA.CONCLUSION:Greater baseline LT and LV measurements are associated with greater increases in anterior segment biometric parameters after laser peripheral iridotomy.AL are not associated with the change of anterior segment biometric parameters.展开更多
Ultrasonic biometry was done in 232 normal eyes and 138 eyes with primary angle closure glaucoma (ACG), using Ultrascan Digital B System IV (10 MHz). The ratio between the lens thickness and the axial length (lens thi...Ultrasonic biometry was done in 232 normal eyes and 138 eyes with primary angle closure glaucoma (ACG), using Ultrascan Digital B System IV (10 MHz). The ratio between the lens thickness and the axial length (lens thickness to axial length factor, LAF) was evaluated as a biometric index for assessing the eye with primary ACG in Chinese. LAF of 2.00 was found to be ideal point of demarcation between ACG and normal eyes (i.e., lens thickness equals to 1/5 of axial length). It appears that LAF is helpful i...展开更多
AIM: To assess the relationship between axial length(AL) and intraocular lens(IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database.METHODS: Retrospectiv...AIM: To assess the relationship between axial length(AL) and intraocular lens(IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database.METHODS: Retrospective analysis of data collected online via astigmatismfix.com, a freely available online toric back-calculator where surgeons enter pre-and postoperative information to help manage residual postoperative astigmatism.Included records were deemed valid with entry of AL and IOL orientation between January 2017 and March 2019.Rotation was determined by a difference of ≥5° between pre-operative intended IOL orientation and actual post-operative IOL orientation.Frequency and magnitude of rotation are presented with means and associated standard deviation(SD).Linear regression models of this association are presented.RESULTS: Records of 6752 eyes were included in the analysis, of which 74.8% were determined to have a rotated IOL.The magnitude of rotation increased with each millimeter(mm) increase in AL with a mean rotation of 13.3°(SD: 12.8°) for eyes with AL 20-20.9 mm and a maximum mean rotation of 30.6°(SD: 30.3°) among eyes with AL 29-29.9 mm.General linear modeling demonstrated a significant association(P<0.0001) with a parameter estimate of 1.19(standard error: 0.159) and R;of 0.0083.CONCLUSION: Analysis from an online database indicates that toric IOLs inserted into eyes with longer AL are more likely to rotate and to rotate more degrees from the target axis.The findings from this study are clinically relevant for surgeons implanting toric IOLs.展开更多
AIM:To evaluate the accuracy of segmented measurement of axial length(AL)in high myopia filled with silicone oil by immersion B-scan ultrasonography(immersion B-scan).METHODS:From June 2016 to June 2020,a total of 67 ...AIM:To evaluate the accuracy of segmented measurement of axial length(AL)in high myopia filled with silicone oil by immersion B-scan ultrasonography(immersion B-scan).METHODS:From June 2016 to June 2020,a total of 67 ultra-high myopia inpatients(67 eyes)who underwent silicone oil removal combined with cataract extraction and intraocular lens(IOL)implantation were retrospectively enrolled.The preoperative axial length(AL)of 31 patients with severe cataract were segmented measured using immersion B-scan(B-scan group)and another 36 patients with mild or moderate cataract were measured using IOLMaster 500(IOLMaster group).The post-operative ALs in two groups were both measured using IOLMaster 500.The IOL power was calculated with Haigis formula.The differences in ALs between pre-and post-surgery,as well as the postoperative refractive spherical equivalent,absolute refractive error,the prediction deviation of postoperative refraction and best corrected visual acuity(BCVA)were compared.RESULTS:The pre-and post-operative ALs were 30.46±1.63 mm(range 28.09-33.51 mm)and 30.42±1.70 mm(range 28.03-33.90 mm)in B-scan group(t=0.644,P=0.542)and 30.51±1.21 mm(range 28.03-33.90 mm)and 30.43±1.27 mm(range 28.54-33.50 mm)in IOLMaster group(t=1.843,P=0.074),respectively.Three months after surgery,BCVA were 0.45±0.13(range 0.3-0.9)and 0.44±0.20(range 0.2-1.0)in B-scan and IOLMaster group respectively(t=0.086,P=0.932).There was no significant difference of the postoperative spherical equivalent(-3.11±0.65 D vs-3.21±0.51 D,t=0.671,P=0.505)and the absolute refractive error(0.589±0.340 vs 0.470±0.245 D,t=1.615,P=0.112)between two groups.In B-scan group,absolute refractive error within±0.50 D was found in 18 eyes(58.1%),within±1.00 D in 26 eyes(83.9%),and within±1.50 D in 31 eyes(100%).In IOLMaster group,absolute refractive error within±0.50 D was found in 23 eyes(63.9%),within±1.00 D in 34 eyes(94.4%),and within±1.50 D in 36 eyes(Z=0.757,P=0.449).CONCLUSION:The segmented measurement of ALs by immersion B-scan shows comparable measurement accuracy with that of IOLMaster 500 in ultra-high myopia patients with severe cataract secondary to silicone oil filling and can obtain an ideal postoperative refractive state.展开更多
<strong>Purpose:</strong> Biometry measurement of pre-operative cataract patients plays<span "=""> a major role in calculating intraocular lens power. This study aimed to review and de...<strong>Purpose:</strong> Biometry measurement of pre-operative cataract patients plays<span "=""> a major role in calculating intraocular lens power. This study aimed to review and determine the distribution of biometry components, such as axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) of pre-operative cataract patient in Indonesian population. <b>Methods: </b>A cross-sectional study data w</span>ere obtained from 2015-2018 cataract surgery at Prima Husada Citra Hospital, Surabaya, East Java, Indonesia. A total of 1295 eyes with cataract was included in the study based on their medical record. We analyzed the data using descriptive analysis and correlated<span "=""> each variable using the Spearman’s Rho analysis. <b>Results: </b>Mean AL, LT and ACD was 23.81 </span>± 1.46 mm, 4.49 ± 0.55 mm, 3.25 ±<span "=""> 0.70 mm respectively. Male has longer AL and deeper ACD with (<i>p</i> < 0.001), while LT was found thicker in female (<i>p</i></span><span "=""> </span>=<span "=""> </span><span "="">0.005). The increase of AL was accompanied by ACD (<i>r</i> = 0.457;<i>p</i> < 0.001) and a thinner LT (<i>r </i>= </span><span "=""><span style="color:#4F4F4F;">-</span>0.101;<i>p</i> < 0.001). <b>Conclusions: </b>LT is increased with age while AL and ACD are shortened with age. There was a positive correlation between AL and ACD, but a</span>n inverse correlation between AL and LT.展开更多
AIM:To investigate whether the axial length(AL)/total corneal refractive power(TCRP)ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan’s syndrome(MFS)in children.METHODS:The rel...AIM:To investigate whether the axial length(AL)/total corneal refractive power(TCRP)ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan’s syndrome(MFS)in children.METHODS:The relationship between the AL/TCRP ratio and the diagnosis of MFS for 192 eyes in 97 children were evaluate.The biological characteristics,including age,sex,AL,and TCRP,were collected from medical records.Receiver operating characteristic(ROC)curve analysis was performed to investigate whether the AL/TCRP ratio effectively distinguishes MFS from other subjects.The Youden index was used to re-divide the whole population into two groups according to an AL/TCRP ratio of 0.59.RESULTS:Of 96 subjects(mean age 7.46±3.28 y)evaluated,56(110 eyes)had a definite diagnosis of MFS in childhood based on the revised Ghent criteria,41(82 eyes)with diagnosis of congenital ectopia lentis(EL)were included as a control group.AL was negatively correlated with TCRP,with a linear regression coefficient of-0.36(R2=0.08).A significant correlation was found between age and the AL/TCRP ratio(P=0.023).ROC curve analysis showed that the AL/TCRP ratio distinguished MFS from the other patients at a threshold of 0.59.MFS patients were present in 24/58(41.38%)patients with an AL/TCRP ratio of≤0.59 and in 34/39(87.18%)patients with an AL/TCRP ratio of>0.59.CONCLUSION:An AL/TCRP ratio of>0.59 is significantly associated with the risk of MFS.The AL/TCRP ratio should be measured as a promising marker for the prognosis of children MFS.Changes in the AL/TCRP ratio should be monitored over time.展开更多
文摘AIM:To elucidate whether differences exist in the impact on retarding the elongation of axial length(AL)among children with myopia when utilizing orthokeratology(ortho-k)lenses employing the corneal refractive therapy(CRT)design versus those employing the vision shaping treatment(VST)design.METHODS:This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years.A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses:CRT,Euclid,and Mouldway.The study’s primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.RESULTS:In the 3-year follow-up,the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group,0.59±0.37 mm in the Euclid lens group,and 0.63±0.38 mm in the Mouldway lens group.A noteworthy disparity emerged between the CRT and Mouldway groups(P<0.01),as well as between the CRT and Euclid groups(P<0.001).Additionally,it was observed that 32.1%of participants who wore CRT lenses experienced a decelerated progression of myopia,in contrast to 47.2%in the Euclid group and 44.4%in the Mouldway group.Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups(P<0.01),and similarly,the CRT group demonstrated a statistically significant difference when compared to the Mouldway group(P<0.05).CONCLUSION:Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia.In contradistinction to ortho-k lenses utilizing the CRT design,those employing the VST design exhibited a more favorable impact regarding retarding AL elongation.
基金the Deputyship for Research and Innovation,Ministry of Education in Saudi Arabia for funding this research work through the project(No.IFKSUOR3-433-1)。
文摘AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments.
基金Supported by the National Natural Science Foundation of China (No.81770972,No.81970843)。
文摘AIM:To evaluate the postoperative refractive prediction error(PE)and determine the factors that af fect the refractive outcomes of combined pars plana vitrectomy(PPV)or silicone oil removal(SOR)with cataract surgery.METHODS:The study is a retrospective,case-series study.Totally 301 eyes of 301 patients undergoing combined PPV/SOR with cataract surgery were enrolled.Eligible individuals were separated into four groups according to their preoperative diagnoses:silicone oil-filled eyes after PPV(group 1),epiretinal membrane(group 2),macular hole(group 3),and primary retinal detachment(RD;group 4).The variables af fecting postoperative refractive outcomes were analyzed,including age,gender,preoperative best-corrected visual acuity(BCVA),axial length(AL),keratometry average,anterior chamber depth(ACD),intraocular tamponade,and vitreoretinal pathology.The outcome measurements include the mean refractive PE and the proportions of eyes with a PE within±0.50 diopter(D)and±1.00 D.RESULTS:For all patients,the mean PE was-0.04±1.17 D,and 50.17%of patients(eyes)had a PE within±0.50 D.There was a significant difference in refractive outcomes among the four groups(P=0.028),with RD(group 4)showing the least favorable refractive outcome.In multivariate regression analysis,only AL,vitreoretinal pathology,and ACD were strongly associated with PE(all P<0.01).Univariate analysis revealed that longer eyes(AL>26 mm)and a deeper ACD were correlated with hyperopic PE,and shorter eyes(AL<26 mm)and a shallower ACD were correlated with myopic PE.CONCLUSION:RD patients have the least favorable refractive outcome.AL,vitreoretinal pathology,and ACD are strongly associated with PE in the combined surgery.These three factors affect refractive outcomes and thus can be used to predict a better postoperative refractive outcome in clinical practice.
基金Supported by National Institute for Medical Research Development(NIMAD)affiliated with the Iranian Ministry of Health and Medical Education(No.963660).
文摘AIM:To determine the normative distribution of axial length(AL),anterior chamber depth(ACD),anterior chamber volume(ACV),anterior chamber angle(ACA),and some of their associated factors in subjects aged 60 and over.METHODS:In this cross-sectional study,160 clusters were sampled using multi-stage cluster sampling in Tehran,Iran.After a preliminary interview,the participants underwent optometric examinations including visual acuity and refraction measurement followed by slit lamp biomicroscopy.Finally,ocular imaging was done using the Pentacam AXL to measure AL,ACD,ACV,and ACA.RESULTS:A total of 4519 eyes of 2436 participants were evaluated,of whom 58.0%(n=1412)were female.The mean age of the subjects was 67.32±6.05y(range:60-95y).The mean AL,ACD,ACV,and ACA was 23.22 mm(23.18-23.27 mm),2.61 mm(2.59-2.62 mm),126.56 mm3(125.08-128.04 mm3),and 30.61°(30.3°-30.92°),respectively.In the multivariable model,after adjusting for the effect of both eyes,the longest and shortest AL was seen in myopic and hyperopic subjects,respectively.AL,ACD,ACV and ACA were significantly larger in men compared to women(P<0.001).Except ACA,other evaluated parameters showed an inverse correlation with age(P<0.001),however,this correlation was insignificant for AL(P=0.623).CONCLUSION:Normative value of AL,and other biometric parameters are specific for each ethnicity,age and sex group.Any alteration in these parameters and their effect on refraction should be considered in this age group,especially in case of cataract surgery.
文摘AIM:To report the myopia-controlling effect of repeated low-level red-light(RLRL)therapy in patients with Stickler syndrome(STL),an inherited collagenic disease typically presenting with early onset myopia.METHODS:Three STL children,aged 3,7,and 11y,received RLRL therapy throughout the follow-up period of 17,3,and 6mo,respectively after exclusion of fundus anomalies.Data on best-corrected visual acuity(BCVA),intraocular pressure,cycloplegic subjective refraction,ocular biometrics,scanning laser ophthalmoscope,optical coherence tomography,genetic testing,systemic disease history,and family history were recorded.RESULTS:At the initiation of the RLRL therapy,the spherical equivalent(SE)of 6 eyes from 3 patients ranged from-3.75 to-20.38 D,axial length(AL)were from 23.88 to 30.68 mm,and BCVA were from 0.4 to 1.0(decimal notation).Myopia progression of all six eyes slowed down after RLRL therapy.AL in five out of the six eyes shortened-0.07 to-0.63 mm.No side effects were observed.CONCLUSION:Three cases of STL whose progression of myopic shift and AL elongation are successfully reduced and even reversed after RLRL therapy.
基金Supported by National Key Basic Research Program of China(973 Program,No.2013CB967000)National Natural Science Foundation of China(No.81271052)
文摘AIM:To evaluate the accuracy of axial length(AL)measurements obtained from immersion B-scan ultrasonography(immersion B-scan)for intraocular lens(IOL)power calculation in patients with high myopia and cataracts.METHODS:Immersion B-scan,contact A-scan ultrasonography(contact A-scan),and the IOLMaster were used to preoperatively measure the AL in 102 eyes from 102 patients who underwent phacoemulsification and IOL implantation.Patients were divided into two groups according to the AL:one containing patients with22 mm≤AL【26 mm(group A)and the other containing patients with AL≥26 mm(group B).The mean error(ME)was calculated from the difference between the AL measurement methods predicted refractive error and the actual postoperative refractive error.RESULTS:Ingroup A,ALs measured byimmersion Bscan(23.48±1.15)didn’t differ significantly from those measured by the IOLMaster(23.52±1.17)or from those by contact A-scan(23.38±1.20).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.090±0.397 D)didn’t differ significantly from those of IOLMaster(-0.095±0.411 D)and contact A-scan(-0.099±0.425 D).In group B,ALs measured by immersion B-scan(27.97±2.21 mm)didn’t differ significantly from those of the IOLMaster(27.86±2.18 mm),but longer than those measured by Contact A-scan(27.75±2.23 mm,P=0.009).In the same group,the standard deviation(SD)of the mean error(ME)of immersion B-scan(-0.635±0.157 D)didn’t differ significantly from those of the IOLMaster(-0.679±0.359 D),but differed significantly from those of contact A-scan(-0.953±1.713 D,P=0.028).CONCLUSION:ImmersionB-scanexhibitsmeasurement accuracy comparable to that of the IOLMaster,and is thus a good alternative in measuring AL in eyes with high myopia when the IOLMaster can’t be used,and it is more accurate than the contact A-scan.
基金Supported by NIH Center Core Grant(P30EY014801),Research to Prevent Blindness Unrestricted Grant,Department of Defense at the Bascom Palmer Eye Institute
文摘AIM: To study ocular axial lengths in pediatric subjects without intraocular pathology. METHODS: An Institutional Review Board-approved consecutive retrospective chart review of axial lengths measured in pediatric subjects who underwent examination under anesthesia due to positive family history of retinoblastoma or other inherited ocular disease. Only subjects without any intraocular pathology in either eye were included. Subjects were stratified into age groups. An axial length model using a logarithmic regression algorithm was calculated.RESULTS: Data from 330 eyes of 165 subjects were included in the study. The mean age at the time of examination was 30.62(SD 18.04)mo. The steepest increase in axial length was present during the first 10 mo of life. After 36 mo, there was no statistically significant axial length growth. CONCLUSION: This study presents the biggest series of pediatric axial lengths in healthy eyes. The axial length model developed with these data may assist in the diagnosis and management of a wide variety of pediatric ophthalmic diseases.
基金Supported by the National Natural Science Foundation of China(No.81371040)Shanghai Smart Medical Special Research Project(No.2018ZHYL0221)+1 种基金Shanghai Municipal Education Commission-Gaofeng Clinical Medicine Grant Support(No.20181810)the Science and Technology Commission of Shanghai(No.17DZ2260100)
文摘AIM: To measure and analysis axial length(AL)/corneal radius of curvature(CRC) ratio and other refractive parameters, provide a medical reference range for refractive development evaluation and earlier visual impairment screening of 3 to 4 y kindergarten students.METHODS: Between April and June 2017, a total of 4350 participants aged 3-to 4-year-old(8700 eyes) from 10 cluster random sampling kindergartens in Shanghai, Pudong District were involved. According to the measurement and analysis of the unaided visual acuity(VA), AL, CRC, AL/CRC ratio, astigmatism and other refractive parameters, the data distribution and reference range were obtained.RESULTS: Uncorrected VA of examined children was 0.23±0.08(logMAR, mean±SD) [95% confidence interval(CI) range ≤0.36];AL was 22.10±0.79 mm(95%CI 20.55-23.65);CRC was 7.86±0.26 mm(95%CI, 7.35-8.37);AL/CRC ratio was 2.81±0.12(95%CI, 2.57-3.05). The median of astigmatism was-0.5 D, a total of 56.3% had astigmatism <-0.50 D, 85.3%<-1.00 D, 6.7%>-1.50 D;71% were astigmatism with the rule. Eye-specific analyses were conducted. Statistical difference of VA was in right and left eyes. There were no significant differences between two eyes of AL, CRC, AL/CRC ratio and astigmatism(P>0.05).CONCLUSION: VA and AL/CRC ratio reference could be used to assess refractive development in children and screening uncorrected refractive errors or amblyopia. Astigmatism needs to be considered in the diagnosis.
文摘AIM: To compare the axial lengths (ALs) measured with Lenstar, IOLMaster and A-scan contact ultrasound (Ultrasound) in normal and high myopia (HM). METHODS: Eighty-four normal eyes and 49 HM eyes were included. Three consecutive measurements were performed on each eye in the following order: Lenstar, IOLMaster, and Ultrasound. The repeatabilities of the AL measurements for each instrument were assessed by calculating the pooled coefficients of variation (CVs) of 18 eyes in each group. Comparisons between the HM and normal groups were made with independent sample t-tests. The inter-device agreements were evaluated with Bland-Altman analyses and paired two-tailed t-tests. RESULTS: For normal group, the CVs of the AL measurements taken with the Lenstar, IOLMaster and Ultrasound were 0.001%, 0.01% and 0.14%, respectively. The corresponding CVs for the HM group were 0.005%, 0.02% and 0.15%, respectively. There was significant difference between the Lenstar and the IOLMaster in normal group (P=0.031) but not in HM group (n=0.100). In the two groups, the Lenstar and the IOLMaster produced higher values than did the Ultrasound (all P〈 0.001). All three instruments exhibited good agreement in terms of AL values. For the intraocular lens (IOL) power calculation using SRK II formula, the Lenstar and the IOLMaster showed 0.5 D higher than Ultrasound in both groups (all P〈0.001). No significant difference existed between the Lenstar and the IOLMaster for the IOL power calculation in both normal (n=0.474) and HM group (P= 0.103). CONCLUSION: The three devices exhibited excellent intra-visit repeatabilities in the AL measurements. The AL and IOL power difference between partial coherence interferometry and ultrasound instruments should be noticed.
基金Supported by the Natural Science Foundation of Shanghai(No.18ZR1435700)Clinical Research Project of Shanghai Health and Family Planning Committee(No.201840199)。
文摘AIM:To explore the photopic pupil size behavior in myopic children undergoing overnight orthokeratology(ortho-k)over 1-year period and its effects on the axial elongation.METHODS:A total of 202 Chinese myopic children were enrolled in this prospective clinical trial.Ninetyfive subjects in ortho-k group and eighty-eight subjects in spectacle group completed the 1-year study.Axial length(AL)was measured before enrollment and every 6mo after the start of ortho-k.The photopic pupil diameter(PPD)was determined using the Pentacam AXL and measured in an examination room with lighting of 300-310 Lx.Stepwise multiple linear regression analysis was used to identify variables contribution to axial elongation.RESULTS:Compared with spectacle group,the average 1-year axial elongation was significantly slower in the ortho-k group(0.25±0.27 vs 0.44±0.23 mm,P<0.0001).In ortho-k group,PPDs significantly decreased from 4.21±0.62 mm to 3.94±0.53 mm after 1mo of lens wear(P=0.001,Bonferroni correction)and the change lasts for 3-month visit.No significantly change during the other follow-up visits was found(P>0.05,Bonferroni correction).The 4.81 mm PPD may be a possible cutoff point in the ortho-k group.Subjects with PPD below or equal to 4.81 mm tended to have smaller axial elongation compared to subjects with PPD above 4.81 mm after 1-year period(t=-3.09,P=0.003).In ortho-k group,univariate analyses indicated that those with older age,greater degree of myopia,longer AL,smaller baseline PPD(PPDbaseline)experienced a smaller change in AL.In multivariate analyses,older age,greater AL and smaller PPDbaseline were associated with smaller increases in AL.In spectacle group,PPD tended to be stable(P>0.05,Bonferroni correction)and did not affect axial growth.CONCLUSION:PPDs experience significantly decreases at 1-month and 3-month ortho-k treatment.Children with smaller PPD tend to experience slower axial elongation and may benefit more from ortho-k.
基金Supported by Education Department Foundation of Sichuan Province(No.15ZA0262).
文摘AIM:To present the 1-year results of a prospective cohort study investigating the efficacy,potential mechanism,and safety of orthokeratology(ortho-k)with different back optic zone diameters(BOZD)for myopia control in children.METHODS:This randomized clinical study was performed between Dec.2020 and Dec.2021.Participants were randomly assigned to three groups wearing ortho-k:5 mm BOZD(5-MM group),5.5 mm BOZD(5.5-MM group),and 6 mm BOZD(6-MM group).The 1-year data were recorded,including axial length,relative peripheral refraction(RPR,measured by multispectral refractive topography,MRT),and visual quality.The contrast sensitivity(CS)was evaluated by CSV-1000 instrument with spatial frequencies of 3,6,12,and 18 cycles/degree(c/d);the corneal higher-order aberrations(HOAs)were measured by iTrace aberration analyzer.The one-way ANOVA was performed to assess the differences between the three groups.The correlation between the change in AL and RPR was calculated by Pearson’s correlation coefficient.RESULTS:The 1-year results of 20,21,and 21 subjects in the 5-MM,5.5-MM,and 6-MM groups,respectively,were presented.There were no statistical differences in baseline age,sex,or ocular parameters between the three groups(all P>0.05).At the 1-year visit,the 5-MM group had lower axial elongation than the 6-MM group(0.07±0.09 vs 0.18±0.11 mm,P=0.001).The 5-MM group had more myopic total RPR(TRPR,P=0.014),with RPR in the 15°–30°(RPR 15–30,P=0.015),30°–45°(RPR 30–45,P=0.011),temporal(RPR-T,P=0.008),and nasal area(RPR-N,P<0.001)than the 6-MM group.RPR 15–30 in the 5.5-MM group was more myopic than that in the 6-MM group(P=0.002),and RPR-N in the 5-MM group was more myopic than that in the 5.5-MM group(P<0.001).There were positive correlations between the axial elongation and the change in TRPR(r=0.756,P<0.001),RPR 15–30(r=0.364,P=0.004),RPR 30–45(r=0.306,P=0.016),and RPR-N(r=0.253,P=0.047).The CS decreased at 3 c/d(P<0.001),and the corneal HOAs increased in the 5-MM group(P=0.030).CONCLUSION:Ortho-k with 5 mm BOZD can control myopia progression more effectively.The mechanism may be associated with greater myopic shifts in RPR.
基金This paper is supported by the Foundation for Research Project of ChinaCommunications Second Highway Survey Design and ResearchInstitute .
文摘The theoretical results of axial force distribution models differ greatly from tests because of the complication of the rock type material. A three-parameter combined-power model is proposed by curves fitting the test data recorded from the pull tests on anchoring bars used in different engineering projects. Based on the comparison of the mechanical characteristics of shaft anchors and prestressed tendons, a two-parameter combined-power function model for prestressed tendons is proposed. The bounded length derived from the model and the suggested values of the parameters are also proposed. Compared with the Gaussian model, the three-parameter combined-power model is more precise and simple in expression. Results also suggest that the bounded length calculated from the average stress method is not safe enough.
文摘AIM:To evaluate the effect of axial length(AL)and anterior chamber depth(ACD)on peripheral refractive profile in myopic patients compared to emmetropic participants.METHODS:This cross-sectional study was conducted in right eyes of 58 participants of whom 38 were emmetropic and 20 were myopic.Central and peripheral refraction were measured at 10°,20°,and 30°eccentricities in nasal and temporal fields using an open-field autorefractor.The Lenstar LS900 was used to measure ACD and AL.The participants were divided into three groups of short(<22.5 mm),normal(22.5-24.5 mm),and long eye(>24.5 mm)according to AL and three groups of low ACD(<3.00 mm),normal ACD(3.00-3.60 mm),and high ACD(>3.60 mm)according to ACD.RESULTS:The mean age of the participants was 22.26±3.09 y(range 18-30 y).The peripheral mean spherical refractive error showed a hypermetropic shift in myopic and emmetropic groups although this shift was more pronounced in the myopic group.The results showed significant changes in the spherical equivalent,J0,and J45 astigmatism in all gazes with an increase in eccentricity(P<0.001).The pattern of refractive error changes was more noticeable in long and short eyes versus normal AL eyes.Moreover,the pattern of peripheral refractive changes was much more prominent in the high ACD group versus the normal ACD group and in the normal ACD group versus the low ACD group.CONCLUSION:Peripheral refraction changes are greater in participants with AL values outside the normal range and deeper ACD values compared to participants with normal AL and ACD.
基金Key Program for Clinical Discipline of Ministry of Health between 2010 and 2012(Grant No.2010-2012-439-175)
文摘Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children.However,when compared with the eyes of normal children,the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus,assessment methods,and statistical outcome,making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed.The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists,with the hope of offering assistance that will enhance long-term therapeutic effects for these children.
基金Supported by the Natural Science Foundation of Shandong Province(No.ZR2020MH172)the Demonstration and Guidance Project of Science and Technology Benefiting People in Qingdao(No.20-3-4-39-nsh)。
文摘AIM:To investigate the association of axial length(AL),lens thickness(LT),and lens vault(LV)with postoperative anterior chamber angle metrics after laser peripheral iridotomy(LPI).METHODS:Prospective observational study of 69 patients(97 eyes)were diagnosed as primary angle-closure suspect(PACS),primary angle closure(PAC)or primary angle-closure glaucoma(PACG).AL,LT,anterior central chamber depth(ACD),angle opening distance(AOD),trabecular iris angle(TIA),and angle recess area(ARA)were measured before and 1 wk after LPI.The association between AL,LT,LV with ACD,AOD,TIA,ARA were analyzed by comparing the differences between preoperative and postoperative measurements for anterior segment biometric parameters.RESULTS:ACD,AOD,TIA,and ARA were significantly increased after LPI(all P<0.05).Greater LT was significantly associated with greater postoperative increases in ACD,AOD,TIA,and ARA(all P<0.05).AL was not significantly associated with changes of anterior segment biometric parameters.Greater LV was significantly associated with greater postoperative increases in ACD,AOD,and TIA(all P<0.05),but was not significantly associated with changes of ARA.CONCLUSION:Greater baseline LT and LV measurements are associated with greater increases in anterior segment biometric parameters after laser peripheral iridotomy.AL are not associated with the change of anterior segment biometric parameters.
文摘Ultrasonic biometry was done in 232 normal eyes and 138 eyes with primary angle closure glaucoma (ACG), using Ultrascan Digital B System IV (10 MHz). The ratio between the lens thickness and the axial length (lens thickness to axial length factor, LAF) was evaluated as a biometric index for assessing the eye with primary ACG in Chinese. LAF of 2.00 was found to be ideal point of demarcation between ACG and normal eyes (i.e., lens thickness equals to 1/5 of axial length). It appears that LAF is helpful i...
基金OSD, Inc.Alcon+1 种基金New World MedicalJohnson and Johnson Vision。
文摘AIM: To assess the relationship between axial length(AL) and intraocular lens(IOL) rotation among eyes receiving a toric IOL and subsequently entered into an online toric back-calculator database.METHODS: Retrospective analysis of data collected online via astigmatismfix.com, a freely available online toric back-calculator where surgeons enter pre-and postoperative information to help manage residual postoperative astigmatism.Included records were deemed valid with entry of AL and IOL orientation between January 2017 and March 2019.Rotation was determined by a difference of ≥5° between pre-operative intended IOL orientation and actual post-operative IOL orientation.Frequency and magnitude of rotation are presented with means and associated standard deviation(SD).Linear regression models of this association are presented.RESULTS: Records of 6752 eyes were included in the analysis, of which 74.8% were determined to have a rotated IOL.The magnitude of rotation increased with each millimeter(mm) increase in AL with a mean rotation of 13.3°(SD: 12.8°) for eyes with AL 20-20.9 mm and a maximum mean rotation of 30.6°(SD: 30.3°) among eyes with AL 29-29.9 mm.General linear modeling demonstrated a significant association(P<0.0001) with a parameter estimate of 1.19(standard error: 0.159) and R;of 0.0083.CONCLUSION: Analysis from an online database indicates that toric IOLs inserted into eyes with longer AL are more likely to rotate and to rotate more degrees from the target axis.The findings from this study are clinically relevant for surgeons implanting toric IOLs.
基金National Natural Science Foundation of China(No.82070921)。
文摘AIM:To evaluate the accuracy of segmented measurement of axial length(AL)in high myopia filled with silicone oil by immersion B-scan ultrasonography(immersion B-scan).METHODS:From June 2016 to June 2020,a total of 67 ultra-high myopia inpatients(67 eyes)who underwent silicone oil removal combined with cataract extraction and intraocular lens(IOL)implantation were retrospectively enrolled.The preoperative axial length(AL)of 31 patients with severe cataract were segmented measured using immersion B-scan(B-scan group)and another 36 patients with mild or moderate cataract were measured using IOLMaster 500(IOLMaster group).The post-operative ALs in two groups were both measured using IOLMaster 500.The IOL power was calculated with Haigis formula.The differences in ALs between pre-and post-surgery,as well as the postoperative refractive spherical equivalent,absolute refractive error,the prediction deviation of postoperative refraction and best corrected visual acuity(BCVA)were compared.RESULTS:The pre-and post-operative ALs were 30.46±1.63 mm(range 28.09-33.51 mm)and 30.42±1.70 mm(range 28.03-33.90 mm)in B-scan group(t=0.644,P=0.542)and 30.51±1.21 mm(range 28.03-33.90 mm)and 30.43±1.27 mm(range 28.54-33.50 mm)in IOLMaster group(t=1.843,P=0.074),respectively.Three months after surgery,BCVA were 0.45±0.13(range 0.3-0.9)and 0.44±0.20(range 0.2-1.0)in B-scan and IOLMaster group respectively(t=0.086,P=0.932).There was no significant difference of the postoperative spherical equivalent(-3.11±0.65 D vs-3.21±0.51 D,t=0.671,P=0.505)and the absolute refractive error(0.589±0.340 vs 0.470±0.245 D,t=1.615,P=0.112)between two groups.In B-scan group,absolute refractive error within±0.50 D was found in 18 eyes(58.1%),within±1.00 D in 26 eyes(83.9%),and within±1.50 D in 31 eyes(100%).In IOLMaster group,absolute refractive error within±0.50 D was found in 23 eyes(63.9%),within±1.00 D in 34 eyes(94.4%),and within±1.50 D in 36 eyes(Z=0.757,P=0.449).CONCLUSION:The segmented measurement of ALs by immersion B-scan shows comparable measurement accuracy with that of IOLMaster 500 in ultra-high myopia patients with severe cataract secondary to silicone oil filling and can obtain an ideal postoperative refractive state.
文摘<strong>Purpose:</strong> Biometry measurement of pre-operative cataract patients plays<span "=""> a major role in calculating intraocular lens power. This study aimed to review and determine the distribution of biometry components, such as axial length (AL), anterior chamber depth (ACD), and lens thickness (LT) of pre-operative cataract patient in Indonesian population. <b>Methods: </b>A cross-sectional study data w</span>ere obtained from 2015-2018 cataract surgery at Prima Husada Citra Hospital, Surabaya, East Java, Indonesia. A total of 1295 eyes with cataract was included in the study based on their medical record. We analyzed the data using descriptive analysis and correlated<span "=""> each variable using the Spearman’s Rho analysis. <b>Results: </b>Mean AL, LT and ACD was 23.81 </span>± 1.46 mm, 4.49 ± 0.55 mm, 3.25 ±<span "=""> 0.70 mm respectively. Male has longer AL and deeper ACD with (<i>p</i> < 0.001), while LT was found thicker in female (<i>p</i></span><span "=""> </span>=<span "=""> </span><span "="">0.005). The increase of AL was accompanied by ACD (<i>r</i> = 0.457;<i>p</i> < 0.001) and a thinner LT (<i>r </i>= </span><span "=""><span style="color:#4F4F4F;">-</span>0.101;<i>p</i> < 0.001). <b>Conclusions: </b>LT is increased with age while AL and ACD are shortened with age. There was a positive correlation between AL and ACD, but a</span>n inverse correlation between AL and LT.
基金Supported by the National Natural Science Foundation of China(No.81770908)the Shanghai Science and Technology Commission(Scientific Innovation Project,No.20Y11911000)。
文摘AIM:To investigate whether the axial length(AL)/total corneal refractive power(TCRP)ratio is a sensitive and simple factor that can be used for the early diagnosis of Marfan’s syndrome(MFS)in children.METHODS:The relationship between the AL/TCRP ratio and the diagnosis of MFS for 192 eyes in 97 children were evaluate.The biological characteristics,including age,sex,AL,and TCRP,were collected from medical records.Receiver operating characteristic(ROC)curve analysis was performed to investigate whether the AL/TCRP ratio effectively distinguishes MFS from other subjects.The Youden index was used to re-divide the whole population into two groups according to an AL/TCRP ratio of 0.59.RESULTS:Of 96 subjects(mean age 7.46±3.28 y)evaluated,56(110 eyes)had a definite diagnosis of MFS in childhood based on the revised Ghent criteria,41(82 eyes)with diagnosis of congenital ectopia lentis(EL)were included as a control group.AL was negatively correlated with TCRP,with a linear regression coefficient of-0.36(R2=0.08).A significant correlation was found between age and the AL/TCRP ratio(P=0.023).ROC curve analysis showed that the AL/TCRP ratio distinguished MFS from the other patients at a threshold of 0.59.MFS patients were present in 24/58(41.38%)patients with an AL/TCRP ratio of≤0.59 and in 34/39(87.18%)patients with an AL/TCRP ratio of>0.59.CONCLUSION:An AL/TCRP ratio of>0.59 is significantly associated with the risk of MFS.The AL/TCRP ratio should be measured as a promising marker for the prognosis of children MFS.Changes in the AL/TCRP ratio should be monitored over time.