期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Reliability of gas holdup measurements using the differential pressure method in a cyclone-static micro-bubble flotation column 被引量:1
1
作者 Xia Wencheng Yang Jianguo Wang Yuling 《Mining Science and Technology》 EI CAS 2011年第6期797-801,共5页
Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expans... Gas holdup is one of the key parameters in flotation process. Gas holdup as measured by a differential pressure method was investigated and the relative errors compared to the average gas holdup from the volume expansion method. The errors were used to establish optimum measurement positions. The results show that the measurement position should be in the middle of the column and in the region half way from the center to the wall (the half-radius). The gas holdup along the axial direction is lower at the bottom and higher at the top of the floatation column. The gas holdup along the radial direction is lower near the wall and higher near the center of the flotation column. The average gas holdup measure- ment can be replaced by regional gas holdup values. 展开更多
关键词 Gas holdup distribution Differential pressure method measurement positions Axial direction Radial direction
下载PDF
Analysis of differences between anatomic and CT measurements for anterior axial pedicle screw placement
2
作者 郑轶Postgraduate School Southern Med Univ 《外科研究与新技术》 2011年第2期85-85,共1页
Objective To explore the differences between anatomic and CT measurements for anterior transoral axial pedicle screw placement. Methods C2 vertebrae of 60 adult spines were measured anatomically,while 20 adult spine v... Objective To explore the differences between anatomic and CT measurements for anterior transoral axial pedicle screw placement. Methods C2 vertebrae of 60 adult spines were measured anatomically,while 20 adult spine vertebrae were 展开更多
关键词 CT Analysis of differences between anatomic and CT measurements for anterior axial pedicle screw placement
下载PDF
Research on the measurement of connecting bars'axial force of JUNO central detector
3
作者 Xiaoyu Yang Lei Yang +9 位作者 Wei He Yatian Pei Yuekun Heng Xiaoyan Ma Huafeng Li Kaixi Huang Caishen Wang Yi Li Xiaohui Qian Zhi Wu 《Radiation Detection Technology and Methods》 CSCD 2020年第3期362-371,共10页
Background The Jiangmen Underground Neutrino Observatory(JUNO)is a multipurpose neutrino experiment designed to determine neutrino mass hierarchy and precisely measure oscillation parameters and study the solar neutri... Background The Jiangmen Underground Neutrino Observatory(JUNO)is a multipurpose neutrino experiment designed to determine neutrino mass hierarchy and precisely measure oscillation parameters and study the solar neutrino,supernova neutrino,geo-neutrino,etc.JUNO's central detector(CD)has 20 kilo-ton liquid scintillator as target mass,which is contained by a huge acrylic sphere with the inner diameter of 35.4 m,and the acrylic sphere is supported by a stainless steel structure through 590 connecting bars.Motivation Part of the connecting bars bear pull force and the other bars bear push force.There is a direct relationship between the stress of connecting bars and that of acrylic sphere.For the installation process of the CD,the pretightening force and axial force of the connecting bars should be monitored with accuracy,and for the filling process and running condition,the precise measurement of axial force can indicate the safety of structure of the CD.Methods Statistical method was used to evaluate the performance of measurement schemes,and 4-fiber Bragg grating measurement scheme was determined to be the final scheme,which can get the measurement uncertainty better than 0.7 kN.Performance of different measurement schemes are discussed in detail,and some related finite element analysis and evalu-ation method are also introduced in this paper. 展开更多
关键词 Axial force measuring Mechanical sensor FEA Central detector JUNO
原文传递
Simultaneous measurement of axial strain and temperature based on twisted fiber structure
4
作者 Xinyue Jiang Ping Lu +4 位作者 Yuan Sun Hao Liao Deming Liu Ziangshan Zhang Hui Liao 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第4期20-24,共5页
In this Letter, an alternative solution is proposed and demonstrated for simultaneous measurement of axial strain and temperature. This sensor consists of two twisted points on a commercial single mode fiber introduce... In this Letter, an alternative solution is proposed and demonstrated for simultaneous measurement of axial strain and temperature. This sensor consists of two twisted points on a commercial single mode fiber introduced by flame-heated and rotation treatment. The fabrication process modifies the geometrical configuration and refractive index of the fiber. Different cladding modes are excited at the first twisted point, and part of them are coupled back to the fiber core at the second twisted point. Experimental results show distinct sensitivities of 34.9 pm/με with 49.23 pm/℃ and -36.19 pm/με with 62.99 pm/℃ for the two selected destructive interference wavelengths. 展开更多
关键词 length Simultaneous measurement of axial strain and temperature based on twisted fiber structure
原文传递
Mass transfer mechanisms in fixed-bed adsorption of erythromycin 被引量:2
5
作者 Ying SUN Jiawen ZHU +2 位作者 Kui CHEN Sheng ZHU Jie XU 《Frontiers of Chemical Science and Engineering》 SCIE EI CSCD 2008年第4期353-360,共8页
The equilibrium and kinetic characteristics of the adsorption of erythromycin to Sepabeads SP825 were determined.The equilibrium data in a batch system was well described by a Langmuir isotherm.The separation performa... The equilibrium and kinetic characteristics of the adsorption of erythromycin to Sepabeads SP825 were determined.The equilibrium data in a batch system was well described by a Langmuir isotherm.The separation performance was investigated in a fixed-bed system with respect to the adsorption superficial velocity,ionic strength and pH.A mathematical model was used to simulate the mass transfer mechanism,taking film mass transfer,pore diffusion and axial dispersion into account.The model predictions were consistent with the experi-mental data and were consequently used to determine the mass transfer coefficients. 展开更多
关键词 fixed-bed adsorption superficial velocity ionic strength erythromycin However investigations on the parameters governing the performance of this technology are still scarce.In the present work a polymeric and porous resin Sepabeads SP825 resin was used for its higher adsorption efficiency compared with the resins reported.The equilib-rium capacity of Sepabeads SP825 for EM in a batch system was established using a Langmuir isotherm.The effects of superficial velocity ionic strength and pH on the adsorption process were determined from the results of fixed bed experiments.And a model of the purification process was used to simulate the mass transfer mechanism which has taken film mass transfer pore diffusion and axial dispersion into account.The experimental adsorp-tion measurements were compared to the results calcu-lated from the model.The completion of these studies provide some essential parameters which are required in order to design a successful purification process and better understand the fundamentals of these process.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部