期刊文献+
共找到2,091篇文章
< 1 2 105 >
每页显示 20 50 100
Design of Cold-Junction Compensation and Disconnection Detection Circuits of Various Thermocouples and Implementation of Multi-Channel Interfaces Using Them-A Secondary Publication
1
作者 Hyeong-Woo Cha 《Journal of Electronic Research and Application》 2024年第1期93-105,共13页
Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC... Cold-junction compensation(CJC)and disconnection detection circuit design of various thermocouples(TC)and multi-channel TC interface circuits were designed.The CJC and disconnection detection circuit consists of a CJC semiconductor device,an instrumentation amplifier(IA),two resistors,and a diode for disconnection detection.Based on the basic circuit,a multi-channel interface circuit was also implemented.The CJC was implemented using compensation semiconductor and IA,and disconnection detection was detected by using two resistors and a diode so that IA input voltage became-0.42 V.As a result of the experiment using R-type TC,the error of the designed circuit was reduced from 0.14 mV to 3μV after CJC in the temperature range of 0°C to 1400°C.In addition,it was confirmed that the output voltage of IA was saturated from 88 mV to-14.2 V when TC was disconnected from normal.The output voltage of the designed circuit was 0 V to 10 V in the temperature range of 0°C to 1400°C.The results of the 4-channel interface experiment using R-type TC were almost identical to the CJC and disconnection detection results for each channel.The implemented multi-channel interface has a feature that can be applied equally to E,J,K,T,R,and S-type TCs by changing the terminals of CJC semiconductor devices and adjusting the IA gain. 展开更多
关键词 R-type thermocouple(TC) Cold-junction compensation(CJC) TC disconnection detection Multi-channel interface circuit Sensor interface
下载PDF
Research on dynamic error compensation for an armored K type thermocouple 被引量:3
2
作者 郝晓剑 邢恩普 +2 位作者 昝清波 王恒飞 周汉昌 《Journal of Measurement Science and Instrumentation》 CAS 2014年第4期10-15,共6页
A new method was proposed, in which a high-power CO2 laser modulated by high frequency was used as the driv- ing source to heat up a surface-temperature sensor. The continual beam and the pulsed beam sent out by the s... A new method was proposed, in which a high-power CO2 laser modulated by high frequency was used as the driv- ing source to heat up a surface-temperature sensor. The continual beam and the pulsed beam sent out by the same laser could be used in the same system to carry on the static calibration of the radiation thermometer and the dynamic calibration of the temperature sensor to be checked. The frequency-response characteristics of high-speed radiation thermometer surpassed that of the temperature sensor, therefore it could be used as the reference value to calibrate the latter and let system error be cor- rected. Differences in the environment of the sensor installing and the error caused by the change of thermo-physical proper- ty could be avoided. Thus, the difficult problem of traceable dynamic calibration of temperature was solved. In experiment, to obtain the frequency characteristics of the thermocouple and the dynamic performance of the K type thermocouple, which could compensate the dynamic characteristics of the sensor, the sensor was dynamically corrected by using the method, and then the mathematical model was established. 展开更多
关键词 thermocouple SURFACE-TEMPERATURE dynamic calibration error compensation TRACEABILITY
下载PDF
Research on measuring time constant of NANMAC thermocouple 被引量:4
3
作者 冯浩 张志杰 +1 位作者 黄晓敏 张晋文 《Journal of Measurement Science and Instrumentation》 CAS 2014年第4期1-4,共4页
The theory for measuring the time constant of thermocouple was introduced, and the method for measuring the time constant of NANMAC thermocouple by using dynamic calibration system of transient surface temperature sen... The theory for measuring the time constant of thermocouple was introduced, and the method for measuring the time constant of NANMAC thermocouple by using dynamic calibration system of transient surface temperature sensor was proposed. In this system, static and dynamic calibrations were conducted for infrared detectors and thermocouples, and then both temperature-time curves were obtained. Since the frequency response of infrared detector is superior to that of calibrat- ed thermocouple, the values measured by infrared detectors are taken as true values. Through dividing the values measured with thermocouples by those with infrared detectors, a normalized curve was obtained, based on which the time constant of thermocouple was measured. With this method, the experiments were carried out with NANMAC thermocouple to obtain its time constant. The results show that the method for measuring the time constant is feasible and the dynamic calibration of thermocouples can be achieved at microsecond and millisecond level. This research has a certain reference value for research and application of NANMAC thermocouple temperature sensor. 展开更多
关键词 thermocouple time constant static calibration dynamic calibration normalized curve
下载PDF
Dynamic Calibration of the Cutting Temperature Sensor of NiCr/NiSi Thin-film Thermocouple 被引量:16
4
作者 CUI Yunxian YANG Deshun +2 位作者 JIA Ying ZENG Qiyong SUN Baoyuan 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2011年第1期73-77,共5页
In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring... In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring transient temperature accurately of cutting area on account of low response speed and limited cutting condition. In this paper, NiCr/NiSi thin-film thermocouples(TFTCs) are fabricated according to temperature characteristic of cutting area in high-speed cutting by means of advanced twinned microwave electro cyclotron resonance(MW-ECR) plasma source enhanced radio frequency(RF) reaction non-balance magnetron sputtering technique, and can be used for transient cutting temperature measurement. The time constants of the TFTCs with different thermo-junction film width are measured at four kinds of sampling frequency by using Ultra-CFR short pulsed laser system that established. One-dimensional unsteady heat conduction model is constructed and the dynamic performance is analyzed theoretically. It can be seen from the analysis results that the NiCr/NiSi TFTCs are suitable for measuring transient temperature which varies quickly, the response speed of TFTCs can be obviously improved by reducing the thickness of thin-film, and the area of thermo-junction has little influence on dynamic response time. The dynamic calibration experiments are made on the constructed dynamic calibration system, and the experimental results confirm that sampling frequency should be larger than 50 kHz in dynamic measurement for stable response time, and the shortest response time is 0.042 ms. Measurement methods and devices of cutting heat and cutting temperature measurement are developed and improved by this research, which provide practical methods and instruments in monitoring cutting heat and cutting temperature for research and production in high-speed machining. 展开更多
关键词 thin-film thermocouple cutting temperature sensor dynamic calibration one-dimensional unsteady heat conduction response time
下载PDF
Improving the Quality of Thermocouple Wire Made of Platinum-rhodium Alloys
5
作者 HORIKOV P. A. MAMONOV S. N. EFIMOV V. N. RADKIN A. N. DROZDOV D. E. 《贵金属》 CAS CSCD 北大核心 2012年第A01期102-103,共2页
For the manufacture of S-type thermocouple the so-called thermocouple wire of platinum and platinum-rhodium alloy is used.One of the main technical requirements for the quality of the wire,according to State Standard ... For the manufacture of S-type thermocouple the so-called thermocouple wire of platinum and platinum-rhodium alloy is used.One of the main technical requirements for the quality of the wire,according to State Standard of Russia(GOST 10821),is the uniformity of its largest thermoelectric force(Thermo-emf) in the length different sections.It was found that a determining impact on the uniformity of the wire thermo-emf is the distribution of rhodium along the length of the wire.The impact of platinum-rhodium melt crystallization conditions on the inhomogeneity of wire manufactured from it.It was suggested that the chemical inhomogeneity of the wire is related to the liquation phase of platinum-rhodium alloy. 展开更多
关键词 thermocouple thermocouple wire platinum-rhodium alloy INHOMOGENEITY CRYSTALLIZATION liquation phase
下载PDF
EMF CHANGES MADE BY COLD DRAWING AND HEATING TREATMENT IN TYPE K HEAVY-GAUGE SHEATHED THERMOCOUPLE CABLES
6
作者 ZHAO Rong-bin(赵容斌) +2 位作者 LI Guan-jun (李冠军) 《Journal of Shanghai Jiaotong university(Science)》 EI 2002年第1期80-83,共4页
The electromotive force (EMF) changes in type K heavy gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy ... The electromotive force (EMF) changes in type K heavy gauge sheathed thermocouple cables was investigated. To cope with this discrepancy owing to EMF steep reduction and understand the difference between type K heavy gauge sheathed thermocouple cables and small ones, the affects of EMF from sheath pipe, drawing times, annealing temperature, annealing time and annealing way were mainly studied and appropriately analyzed. The results show the change in the thermal EMF is related with the residual stress and crystal defects, which are imparted by cold work during manufacture. The affects of cold work can be removed by annealing. Finally, a feasible way of fabricating heavy gauge sheathed thermocouples was suggested according to practical situation. 展开更多
关键词 EMF CHANGES cold drawing HEATING TREATMENT TYPE K heavy-gauge thermocouple
下载PDF
The Linearized Design Of Thermocouple Sensor
7
作者 Xiang-zhong LI,An-li TAO,Li-na HAN,Jun-guo LIU,Yun-zhou LI,Shao-gang LI (College of Information and Electrical Engineering,Shandong University of Science and Technology,Qingdao 266510, China) 《Journal of Measurement Science and Instrumentation》 CAS 2010年第S1期104-106,共3页
There are large errors of linear measurement when the thermocouple measure temperature as temperature sensor.In order to improve the measurement precision,the sensor cold junction compensation and nonlinear compensati... There are large errors of linear measurement when the thermocouple measure temperature as temperature sensor.In order to improve the measurement precision,the sensor cold junction compensation and nonlinear compensation are usually needed.For the circumstances that the cold junction’s temperature is determinate,there is biggish nonlinear between thermoelectric power and temperature signals of the thermocouple sensor’s output.In order to solve the problem,this paper proposed a practical method of linear compensation,introduced the principle of linear compensation and gave the corresponding compensation circuit and circuit analysis.This circuit has the characteristic of simpleness,high reliability,small linear error and so on. 展开更多
关键词 NONLINEAR thermocouple COMPENSATION
下载PDF
THERMOCOUPLE USED FOR TEMPERATURE MEASUREMENT OF ALUMINIUM CELLS BY DYNAMIC METHOD
8
作者 Yu, Xuebin (Institute of Composite Material, Jiao Tong University, Shanghai 200030)Wang, Huazhang Xue, Jian Liu, Yexiang(Central South University of Technology, Changsha 410083) 《中国有色金属学会会刊:英文版》 CSCD 1994年第4期39-41,共3页
THERMOCOUPLEUSEDFORTEMPERATUREMEASUREMENTOFALUMINIUMCELLSBYDYNAMICMETHOD¥Yu,Xuebin(InstituteofCompositeMater... THERMOCOUPLEUSEDFORTEMPERATUREMEASUREMENTOFALUMINIUMCELLSBYDYNAMICMETHOD¥Yu,Xuebin(InstituteofCompositeMaterial,JiaoTongUnive... 展开更多
关键词 ELECTROLYSER DYNAMIC METHOD TEMPERATURE MEASUREMENT thermocouple
下载PDF
Erosion thermocouple temperature acquisition system
9
作者 王飞跃 张志杰 王文廉 《Journal of Measurement Science and Instrumentation》 CAS 2013年第1期14-18,共5页
Aiming at high requirements of temperature measurement system in high temperature,high pressure,highly corrosive and other special environments,a temperature acquisition system based on field-programmable gate array(F... Aiming at high requirements of temperature measurement system in high temperature,high pressure,highly corrosive and other special environments,a temperature acquisition system based on field-programmable gate array(FPGA) which is the controller of the system is designed.Also a Flash memory is used as the memory and an erosion thermocouple is used as sensor of the system.Compared with the traditional system using complex programmable logic device(CPLD)and microcontroller unit(MCU)as the main body,this system has some advantages,such as short response time,small volume,no loss of data once power is off,high precision,stability and reliability.And the sensor of the system can be reused.In this paper,boiling water experiment is used to verify accuracy of the system.The millisecond level signal from firecrackers is for verifying the stability and fast response characteristics of the system.The results of experiment indicate that the temperature measurement system is more suitable for the field of explosion and other environments which have high requirements for the system. 展开更多
关键词 Tungsten-Rhenium thermocouple field-programmable gate array(FPGA) Flash memory
下载PDF
Proposal and Verification of Simultaneous Measurement Method for Three Thermoelectric Properties with Film-Type Thermocouple Probe
10
作者 Takumi Yamazaki Ai Ueno Hosei Nagano 《Journal of Electronics Cooling and Thermal Control》 2017年第2期23-32,共10页
A new simultaneous measurement method for the measurement of the three thermoelectric properties with a film-type thermocouple probe was proposed. Seebeck coefficient was measured using the steady-state condi-tion of ... A new simultaneous measurement method for the measurement of the three thermoelectric properties with a film-type thermocouple probe was proposed. Seebeck coefficient was measured using the steady-state condi-tion of the differential method. The electrical resistivity was measured us-ing the four-probe method and the thermal diffusivity is measured using the periodic heating method. The effectiveness of the proposed method was verified using constantan as a reference material. After describing the effectiveness of the method, the measurement of three thermoelectric properties of Bi0.3Sb1.7Te3, which is a thermoelectric material, was per-formed. 展开更多
关键词 Film-Type thermocouple Sensor SIMULTANEOUS Measurement THERMOELECTRIC Properties
下载PDF
Comprehensive effects of traditional Chinese medicine treatment on heart failure and changes in B-type natriuretic peptide levels: A meta-analysis
11
作者 Li-Li Xia Shu-Yun Yang +2 位作者 Jun-Yao Xu Han-Qing Chen Zhu-Yuan Fang 《World Journal of Clinical Cases》 SCIE 2024年第4期766-776,共11页
BACKGROUND Heart failure(HF),a common cardiovascular condition,is characterized by significant morbidity and mortality.While traditional Chinese medicine(TCM)is often used as a complementary approach in HF management,... BACKGROUND Heart failure(HF),a common cardiovascular condition,is characterized by significant morbidity and mortality.While traditional Chinese medicine(TCM)is often used as a complementary approach in HF management,systematic evalua-tions of its impact on clinical outcomes,TCM syndrome scores,and B-type natriuretic peptide(BNP)levels are lacking.This study fills this gap through a comprehensive analysis of randomized controlled trials(RCTs)focusing on TCM for HF treatment.It encompasses an assessment of methodological quality,a meta-analysis,and an evaluation of evidence quality based on established standards.The results offer crucial insights into the potential advantages and constraints of TCM in HF management.RCTs on TCM for HF treatment published since the establishment of the database were searched in four Chinese and English databases,including China National Knowledge Infrastructure,Wanfang,VIP Information Chinese Science and Technology Journal,and PubMed.Methodological quality was assessed for the included studies with the Cochrane risk-of-bias assessment tool,and the meta-analysis and publication bias assessment was performed with the RevMan5.3 software.Finally,the quality of evidence was rated according to the GRADE criteria.RESULTS A total of 1098 RCTs were initially retrieved.After screening,16 RCTs were finally included in our study,which were published between 2020 and 2023.These RCTs involved 1660 HF patients,including 832 in the TCM group[TCM combined with conventional Western medicine(CMW)treatment]and 828 in the CWM group(CWM treatment).The course of treatments varied from 1 wk to 3 months.TCM syndrome differentiation was analyzed in 11 of the included RCTs.In all included RCTs,outcome indicators included comprehensive clinical outcomes,TCM syndrome scores,and BNP levels.The meta-analysis results showed significant differences between the TCM and CWM groups in terms of comprehensive clinical outcomes[risk ratio=-0.54;95%confidence interval(CI)=-0.61,-0.47;P<0.00001],TCM syndrome scores[weighted mean difference(WMD)=-142.07;95%CI=-147.56,-136.57;P<0.00001],and BNP levels(WMD=-142.07;95%CI=-147.56,-136.57;P<0.00001).According to the GRADE criteria,RCTs where"TCM improves clinical comprehensive outcomes"were rated as low-quality evidence,and RCTs where"TCM reduces TCM syndrome scores"or"TCM decreases BNP levels"were rated as medium-quality evidence.CONCLUSION TCM combined with CWM treatment effectively improves comprehensive clinical outcomes and diminishes TCM syndrome scores and BNP levels in HF patients.Given the low and medium quality of the included RCTs,the application of these results should be cautious. 展开更多
关键词 Traditional Chinese medicine Heart failure Comprehensive clinical outcomes Traditional Chinese medicine syndrome score b-type natriuretic peptide level Meta-analysis©The Author(s)2024.Published by Baishideng Publishing Group Inc.
下载PDF
(3+1)维B-type Kadomtsev-Petviashvili-Boussinesq方程的周期孤子解 被引量:3
12
作者 彭丽娟 《南昌大学学报(理科版)》 CAS 北大核心 2020年第2期124-127,共4页
Kadomtsev-Petviashvili方程是一类重要的非线性偏微分方程,有很多的应用。本文主要研究(3+1)维B-type Kadomtsev-Petviashvili-Boussinesq方程。利用一个假设,我们找到了该方程大量新的精确解,并通过一些三维图形展示了这些解的物理结... Kadomtsev-Petviashvili方程是一类重要的非线性偏微分方程,有很多的应用。本文主要研究(3+1)维B-type Kadomtsev-Petviashvili-Boussinesq方程。利用一个假设,我们找到了该方程大量新的精确解,并通过一些三维图形展示了这些解的物理结构和特点。 展开更多
关键词 Hirota双线性形式 b-type Kadomtsev-Petviashvili-Boussinesq方程 周期孤子解
下载PDF
Comparative study of galectin-3 and B-type natriuretic peptide as biomarkers for the diagnosis of heart failure 被引量:29
13
作者 Qiu-Sheng YIN Bing SHI Lan Dong Lei BI 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2014年第1期79-82,共4页
Background Heart failure (HF) is a common disease with complex pathophysiological causes. The diagnosis of HF commonly relies on comprehensive analyses of medical history and symptoms, and results from echocardiogra... Background Heart failure (HF) is a common disease with complex pathophysiological causes. The diagnosis of HF commonly relies on comprehensive analyses of medical history and symptoms, and results from echocardiography and biochemical tests. Galectin-3, a rela-tively new biomarker in HF, was approved by the US Food and Drug Administration in 2010 as a marker in the stratification of risk for HF. We assessed galectin-3 as a biomarker for HF diagnosis in patients with preserved ejection fraction (pEF) and compared its performance with that of B-type natriuretic peptide (BNP). Methods Thirty-five pEF patients with HF (HFpEF group) and 43 pEF patients without HF (control group) were enrolled. Plasma levels of galectin-3 and BNP in HFpEF and control subjects were determined. Sensitivity, specificity, pre dictive values, and accuracy of galectin-3 and BNP as markers for HF diagnosis were calculated and compared. Results Levels of galec- tin-3 and BNP were 23.09 ±6.97 ng/mL and 270.46 ± 330.41 pg/mL in the HFpEF group, and 16.74 ± 2.75 ng/mL and 59.94 ± 29.93 pg/mL in the control group, respectively. Differences in levels of galectin-3 and BNP between the two groups were significant (P 〈 0.01). As a bio- marker for HF diagnosis in study subjects, galectin-3 showed sensitivity and specificity of 94.3% and 65.1%, respectively, at a cutoff value of 17.8 ug/mL. BNP showed sensitivity and specificity of 77.1% and 90.7%, respectively, at a cutoff value of 100 pg/mL. Galectin-3 was a significantly more sensitive (P 〈 0.05) but less specific (P 〈 0.01) biomarker compared with BNP. Differences in positive predictive value, negative predictive value, and accuracy between galectin-3 and BNP markers were not significant (P 〉 0.05). Areas under the receiver operating characteristic curve (95% confidence interval) were 0.891 (0.808-0.974) and 0.896 (0.809-0.984) for galectin-3 and BNP, respec- tively, with no significant difference between the two values (P 〉 0.05). Conclusions The level of galectin-3 is significantly elevated in patients with HF. Galectin-3 and BNP are useful biomarkers for the diagnosis of HF in patients with pEF. 展开更多
关键词 Heart failure Preserved ejection fraction GALECTIN-3 b-type natriuretic peptide DIAGNOSIS
下载PDF
Marked elevation of B-type natriuretic peptide in patients with heart failure and preserved ejection fraction 被引量:8
14
作者 Samuel Tate Andrea Griem +2 位作者 Blythe Durbin-Johnson Clifton Watt Saul Schaefer 《The Journal of Biomedical Research》 CAS 2014年第4期255-261,共7页
Marked elevations of B-type natriuretic peptide (BNP) are not generally seen in patients with heart failure and preserved ejection fraction (HFpEF). The objective of this study was to examine the clinical and labo... Marked elevations of B-type natriuretic peptide (BNP) are not generally seen in patients with heart failure and preserved ejection fraction (HFpEF). The objective of this study was to examine the clinical and laboratory characteristics of a large cohort of patients with HFpEF and markedly elevated BNP. A retrospective examination of 421 inpatients at a university hospital admitted with a diagnosis of HFpEF was performed. Clinical and echocardiographic data in 4 groups of patients with levels of BNP ≤ 100 pg/mL, 100-400 pg/mL, 400-1,000 pg/mL and 〉 1,000 pg/mL were compared. Patients with HFpEF and BNP 〉 1,000 pg/mL (28% of the population) were characterized by impaired renal function and greater use of anti-hypertensive medications. A subset of these patients with BNP 〉 1,000 pg/mL had normal renal function (21%) and were significantly older, more frequently female, and tended to have lower ejection fractions. Conversely, patients with HFpEF and BNP ≤100 pg/mL were younger and had preserved renal function. BNP was inversely related to the likelihood of subsequent admission for heart failure, but not to myocardial infarction or death. In conclusion: BNP 〉 1,000 pg/mL is seen in almost 1/3 of patients hospitalized with HFpEF. This elevation of BNP often reflects impaired renal function, but can also be seen in patients with preserved renal function but relatively impaired systolic function. 展开更多
关键词 b-type natriuretic peptide diastolic heart failure chronic kidney disease
下载PDF
B-type natriuretic peptide in predicting the severity of community-acquired pneumonia 被引量:19
15
作者 Jing Li Huan Ye Li Zhao 《World Journal of Emergency Medicine》 CAS 2015年第2期131-136,共6页
BACKGROUND: Although pneumonia severity index(PSI) is widely used to evaluate the severity of community-acquired pneumonia(CAP), the calculation of PSI is very complicated. The present study aimed to evaluate the role... BACKGROUND: Although pneumonia severity index(PSI) is widely used to evaluate the severity of community-acquired pneumonia(CAP), the calculation of PSI is very complicated. The present study aimed to evaluate the role of B-type natriuretic peptide(BNP) in predicting the severity of CAP.METHODS: For 202 patients with CAP admitted to the emergency department, BNP levels, cardiac load indexes, inf lammatory indexes including C-reactive protein(CRP), white blood cell count(WBC), and PSI were detected. The correlation between the indexes and PSI was investigated. BNP levels for survivor and non-survivor groups were compared, and a receiver operating characteristic(ROC) curve analysis was performed on the BNP levels versus PSI.RESULTS: The BNP levels increased with CAP severity(r=0.782, P<0.001). The BNP levels of the high-risk group(PSI classes IV and V) were signifi cantly higher than those of the low-risk group(PSI classes I–III)(P<0.001). The BNP levels were signifi cantly higher in the non-survivor group than in the survivor group(P<0.001). In addition, there were positive correlations between BNP levels and PSI scores(r=0.782, P<0.001). The BNP level was highly accurate in predicting the severity of CAP(AUC=0.952). The optimal cut-off point of BNP level for distinguishing high-risk patients from low-risk ones was 125.0 pg/m L, with a sensitivity of 0.891 and a specifi city of 0.946. Moreover, BNP level was accurate in predicting mortality(AUC=0.823). Its optimal cut-off point for predicting death was 299.0 pg/m L, with a sensitivity of 0.675 and a specifi city of 0.816. Its negative predictive cut-off value was 0.926, and the positive predictive cut-off value was 0.426.CONCLUSION: BNP level is positively correlated with the severity of CAP, and may be used as a biomarker for evaluating the severity of CAP. 展开更多
关键词 Community-acquired pneumonia b-type natriuretic peptide Pneumonia severity ndex BIOMARKER EMERGENCY Disease severity assessment
下载PDF
Formation and Developmental Characteristics of A- and B-Type Starch Granules in Wheat Endosperm 被引量:9
16
作者 YIN Yong-an QI Jun-cang +2 位作者 LI Wei-hua CAO Lian-pu WANG Zi-bu 《Journal of Integrative Agriculture》 SCIE CSCD 2012年第1期73-81,共9页
Wheat grain natural transverse sections of 12 periods were observed and analyzed using scanning electron micrographs technology and Bio-Quant system IV image analyzer in order to detect the developing process of A- an... Wheat grain natural transverse sections of 12 periods were observed and analyzed using scanning electron micrographs technology and Bio-Quant system IV image analyzer in order to detect the developing process of A- and B-type starch granules. In addition, the chemical composition and starch granule-bound proteins (SGPs) of A- and B-type starch granules were tested and analyzed. The results showed that A-type starch granules in wheat began from 3 d post anthesis (DPA) till grain maturing and B-type starch granules occured after 15 DPA till grain maturing. Approximately 98.5% of chemical compositions in both A- and B-type starch granules were amylose and amylopectin, and more than half of which were amylopectin. The amylopectin contents, average chain length, and chain length distribution (degree of polymerization〉 40) of amylopectin in A-type starch granules were significant higher than that of B-type starch granules. SGP-145, SGP-140, and SGP-26 kD were associated with A-type starch formation in wheat grain. 展开更多
关键词 wheat (Triticum aestivum L.) A- and b-type starch granules formation and developmental characteristics
下载PDF
Environmental Embrittlement in A_3B-type Intermetallic Alloys 被引量:3
17
作者 Xiaojing WAN Jiahong ZHU +1 位作者 Kailiang JING Weijie CHEN and Yue WU(Institute of Metallurgy and Materials Science, Shanghai University of Technology, Shanghai, 200072, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1994年第1期39-53,共15页
Environmental embrittlement in A3B-type intermetallics based on Ni3Al and Fe3Al has been studied in this paper. For the Ni3Al doped with 120 wt ppm B and Ni,(Al,Cr.Zr) doped with 80 wt ppm B,their elongation and ultim... Environmental embrittlement in A3B-type intermetallics based on Ni3Al and Fe3Al has been studied in this paper. For the Ni3Al doped with 120 wt ppm B and Ni,(Al,Cr.Zr) doped with 80 wt ppm B,their elongation and ultimate tensile strength decreased in the sequence:of vacuum > air >hydrogen. while for Ni,(Al,Mn) doped with 400 wt ppm B no envifonmental degradation was ob served, although a -Ni3(Al,Mn) alloy without B showed a decrease in ductility when tested in air in stead of oxygen. It is supposed that boron and hydrogen compete for the occupation of interstitial sites near grain boundaries. If boron content is sufficiently low, hydrogen embrittlement occurs ;however, if its content is sufficiently high. boron addition is capable of eliminating envjronmental ef fect in Ni3Al-based alloysi As to the micromechanism of hydrogen embrittlement in Ni3Al+B. S EM in situ observations showed that both grain boundary decohesion and a high stress concentration con tributed to hydrogen-assisted jntergranu lar cracking in this alloy. For the Fe3Al and Fe3 (Al.Cr) alloys.their mechanical properties depended strongly on grain size / grain shape and testing environment. A strain rate effect on ductiIity and fracture strength was also observed in the Fe3Al and Fe,(Al,Cr)+B aIloys. Preoxidation increased the ductility of the Fe,(Al,Cr)+B alloy. All these results can be rationalized from a hypothesis that surface reaction is the controlling process in embrittling Fe3Al-based alloys. 展开更多
关键词 CR TYPE Environmental Embrittlement in A3b-type Intermetallic Alloys FIGURE
下载PDF
Hepatocellular carcinoma with chronic B-type hepatitis complicated by autoimmune hemolytic anemia:A case report 被引量:2
18
作者 Toshie Okada Keiichi Kubota +2 位作者 Junji Kita Masato Kato Tokihiko Sawada 《World Journal of Gastroenterology》 SCIE CAS CSCD 2007年第32期4401-4404,共4页
A 57-year-old man consulted a local hospital because of a persistent slight fever. At the age of 37 years he was diagnosed having B-type hepatitis, but left the liver dysfunction untreated. Twenty years later, he was ... A 57-year-old man consulted a local hospital because of a persistent slight fever. At the age of 37 years he was diagnosed having B-type hepatitis, but left the liver dysfunction untreated. Twenty years later, he was diagnosed having chronic hepatitis B, hepatocellular carcinoma (HCC) and macrocytic anemia, and referred to our hospital for further investigation. A HCC with a maximum diameter of 5.2 cm was detected in segment 8. Results of blood tests included 1.8 mg/dL serum total bilirubin, 0.9 mg/dL bilirubin, less than 10 mg/dL haptoglobin, 7.9 g/dL hemoglobin, 130 fL MCV, and 14.5% reticuloo/tes. A bone marrow sample showed erythroid hyperplasia. The direct Coombs test gave a positive result. We diagnosed the anemia as autoimmmune hemolytic anemia (AIHA), for which prednisolone could not be administered due to positivity for HBsAg and HBeAg. After preparation of washed blood cells for later transfusion, the patient underwent systematic resection of segment 8. The cut surface of the resected specimen demonstrated an encapsulated yellow-brownish tumor measuring 52 mmx 40 mm which was diagnosed pathologicaly as moderately differentiated HCC. On the 9th postoperative day, the patient's temperature rose to 38℃, and exacerbated hemolysis was observed. The maximum total bilirubin value was 5.8 mg/dL and minimum hemoglobin level was 4.6 g/dL. He tolerated this period without blood transfusion. Currently he is being followed up as an outpatient, and shows no signs of HCC recurrence or symptoms of anemia. AIHA associated with HBV infection has been described in only three previous cases, and the present case is the first in which surgery was performed for accompanying HCC. 展开更多
关键词 Hepatocellular carcinoma b-type hepatitis Auto-immune hemolytic anemia
下载PDF
Characterization of A-and B-type starch granules in Chinese wheat cultivars 被引量:9
19
作者 ZHANG Yan GUO Qi +3 位作者 FENG Nan WANG Jin-rong WANG Shu-jun HE Zhong-hu 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2016年第10期2203-2214,共12页
Starch is the major component of wheat flour and serves as a multifunctional ingredient in food industry. The objective of the present study was to investigate starch granule size distribution of Chinese wheat cultiva... Starch is the major component of wheat flour and serves as a multifunctional ingredient in food industry. The objective of the present study was to investigate starch granule size distribution of Chinese wheat cultivars, and to compare structure and functionality of starches in four leading cultivars Zhongmai 175, CA12092, Lunxuan 987, and Zhongyou 206. A wide variation in volume percentages of A- and B-type starch granules among genotypes was observed. Volume percentages of A- and B-type granules had ranges of 68.4–88.9% and 9.7–27.9% in the first cropping seasons, 74.1–90.1% and 7.2–25.3% in the second. Wheat cultivars with higher volume percentages of A- and B-type granules could serve as parents in breeding program for selecting high and low amylose wheat cultivars, respectively. In comparison with the B-type starch granules, the A-type granules starch showed difference in three aspects:(1) higher amount of ordered short-range structure and a lower relative crystallinity,(2) higher gelatinization onset(To) temperatures and enthalpies(ΔH), and lower gelatinization conclusion temperatures(Tc),(3) greater peak, though, and final viscosity, and lower breakdown viscosity and pasting temperature. It provides important information for breeders to develop potentially useful cultivars with particular functional properties of their starches suited to specific applications. 展开更多
关键词 bread wheat A-and b-type starch granules short-range molecular order relative crystallinity gelatinization and pasting properties
下载PDF
Phase Evolution and Magnetic Studies of La and Refractory Metals Co-substituted α-Fe/R_2Fe_(14)B-type Nanocomposites 被引量:1
20
作者 W. C. Changt, S.H. Wang, S.J. Chang and M. Y. Tsai (Department of Physics, Chung Cheng University, Ming-Hsiung, Chia-Yi, 621, Taiwan-China Q.Chen) (Rhodia Inc., Rare Earths and Gallium, CN 7500, Cranbury, New Jersey 08512, U.S.A.) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期102-106,共5页
Phase evolution and magnetic properties of (Nd_o.95La_0.05)9.5-11Febal.M_2B10.5. where M=Cr, Ti, Nb, V, Mo, Zr, Hf, Ta, Mn or W, melt spun ribbons have been investigated. Almost all the alloy ribbons. except for(Nd_0.... Phase evolution and magnetic properties of (Nd_o.95La_0.05)9.5-11Febal.M_2B10.5. where M=Cr, Ti, Nb, V, Mo, Zr, Hf, Ta, Mn or W, melt spun ribbons have been investigated. Almost all the alloy ribbons. except for(Nd_0.95La_0.05)_9.5Fe_78M_2B_10.5(M=Mo and Mn),consist merely two magnetic phases, namely α-Fe and R_2Fe_14B, which display a better combination of _iH_c and magnetic energy product. Remanence (Br) and coercivity (i_H_c) values in the range of 8.0 to 9.1 kG and 9.5 to 18.9 kOe. respectively, can be achieved. Among compositions studied, the Ti and W-substitutions were found to be most effective in increasing the Br and i_H_c, respectively. For a fixed refractory metal substitution, namely, M=C_r, Ti or Nb, an increase in the total rare earth concentration resulted in nanocomposites of small grain sizes and a high volume fraction of the R_2Fe_14B phase, leading to an increase in the magnetic properties. 展开更多
关键词 Fe/R2Fe b-type Nanocomposites Phase Evolution and Magnetic Studies of La and Refractory Metals Co-substituted TYPE LA
下载PDF
上一页 1 2 105 下一页 到第