The turbidity criterion for the product water of a WTP according to the State Project ‘863’ on the safeguard technology of drinking water in the southern areas of China is 0.1 NTU. The turbidity removal in the activ...The turbidity criterion for the product water of a WTP according to the State Project ‘863’ on the safeguard technology of drinking water in the southern areas of China is 0.1 NTU. The turbidity removal in the activated carbon filter was analyzed in a pilot-scale test and an innovative technology to improve the turbidity removal in a biologically activated carbon (BAC) filter was put forward in order to meet the criterion. Experimental results showed that the enhanced filtration by adding polymerized aluminium chloride (PAC) into the BAC filter was quite effective in turbidity control. The effluent turbidity was kept at a stable level (mean) of 0.033 NTU with a high removal of about 80% for influent turbidity of 0.110-0.240 NTU with an addition of PAC at 0.05 mg L -1, meeting the requirement for filtrate turbidity equal to or less than 0.1NTUC totally. In addition, the larger the PAC dosage was, the lower the effluent turbidity was. However, further improvement of turbidity removal was not obvious for PAC dosages beyond 0.10 mg L -1, and an optimal PAC dosage in the range of 0.]05-0.10 mg L -1 was proposed.展开更多
To counter the mass reproduction and penetration of crustacean zooplankton in Biological Activated Carbon(BAC)filters which may result in the presence of organisms in potable water and water pollution,this paper analy...To counter the mass reproduction and penetration of crustacean zooplankton in Biological Activated Carbon(BAC)filters which may result in the presence of organisms in potable water and water pollution,this paper analyzed the factors affecting organisms' reproduction in BAC filters.A comparative study was performed on the density and composition of crustacean zooplankton of the concerned water treatment units of two advanced water plants(Plant A and B)which with the same raw water and the same treatment technique in southern China.The results obtained show that the crustaceans' density and composition was very different between the sand filtered water of Plant A and Plant B.which Harpacticoida bred sharply in the sediment tanks and penetrated sand filter into BAC filters was the primary reason of crustaceans reproduce in BAC filters of Plant A.For prevention of the organisms reproduction in BAC,some strengthen measures was taken including pre-chlorination,cleaning coagulation tanks and sediment tanks completely,increasing sludge disposal frequency to stop organisms enter BAC filters,and the finished water quality was improved and enhanced.展开更多
Due to the importance of biological safety in drinking water quality and the disadvantages which exist in traditional methods of detecting typical microorganisms such as Cryptosporidium and Giardia, it is necessary to...Due to the importance of biological safety in drinking water quality and the disadvantages which exist in traditional methods of detecting typical microorganisms such as Cryptosporidium and Giardia, it is necessary to develop an alternative. Particle counts is a qualitative measurement of the amount of dissolved solids in water. The removal rate of particle counts was previously used as an indicator of the effectiveness of a biological activated carbon (BAC) filter in removing Cryptosporidium and Giardia. The particle counts in a BAC filter effluent over one operational period and the effects of BAC filter construction and operational parameters were investigated with a 10 m3/h pilot plant. The results indicated that the maximum particle count in backwash remnant water was as high as 1296 count/ml and it needed about 1.5 h to reduce from the maximum to less than 50 count/ml. During the standard filtration period, particle counts stay constant at less than 50 count/ml for 5 d except when influ- enced by sand filter backwash remnant water. The removal rates of particle counts in the BAC filter are related to characteristics of the carbon. For example, a columned carbon and a sand bed removed 33.3% and 8.5% of particles, respectively, while the particle counts in effluent from a cracked BAC filter was higher than that of the influent. There is no significant difference among particle removal rates with different filtration rates. High post-ozone dosage (>2 mg/L) plays an important role in particle count removal; when the dosage was 3 mg/L, the removal rates by carbon layers and sand beds decreased by 17.5% and increased by 9.5%, respectively, compared with a 2 mg/L dosage.展开更多
文摘The turbidity criterion for the product water of a WTP according to the State Project ‘863’ on the safeguard technology of drinking water in the southern areas of China is 0.1 NTU. The turbidity removal in the activated carbon filter was analyzed in a pilot-scale test and an innovative technology to improve the turbidity removal in a biologically activated carbon (BAC) filter was put forward in order to meet the criterion. Experimental results showed that the enhanced filtration by adding polymerized aluminium chloride (PAC) into the BAC filter was quite effective in turbidity control. The effluent turbidity was kept at a stable level (mean) of 0.033 NTU with a high removal of about 80% for influent turbidity of 0.110-0.240 NTU with an addition of PAC at 0.05 mg L -1, meeting the requirement for filtrate turbidity equal to or less than 0.1NTUC totally. In addition, the larger the PAC dosage was, the lower the effluent turbidity was. However, further improvement of turbidity removal was not obvious for PAC dosages beyond 0.10 mg L -1, and an optimal PAC dosage in the range of 0.]05-0.10 mg L -1 was proposed.
基金Sponsored by the Major National S&T Program-Water Pollution and Governance(Grant No.2009ZX07423-003)
文摘To counter the mass reproduction and penetration of crustacean zooplankton in Biological Activated Carbon(BAC)filters which may result in the presence of organisms in potable water and water pollution,this paper analyzed the factors affecting organisms' reproduction in BAC filters.A comparative study was performed on the density and composition of crustacean zooplankton of the concerned water treatment units of two advanced water plants(Plant A and B)which with the same raw water and the same treatment technique in southern China.The results obtained show that the crustaceans' density and composition was very different between the sand filtered water of Plant A and Plant B.which Harpacticoida bred sharply in the sediment tanks and penetrated sand filter into BAC filters was the primary reason of crustaceans reproduce in BAC filters of Plant A.For prevention of the organisms reproduction in BAC,some strengthen measures was taken including pre-chlorination,cleaning coagulation tanks and sediment tanks completely,increasing sludge disposal frequency to stop organisms enter BAC filters,and the finished water quality was improved and enhanced.
基金Project (No. 2002AA601120) supported by the Hi-Tech Research and Development Program (863) of China
文摘Due to the importance of biological safety in drinking water quality and the disadvantages which exist in traditional methods of detecting typical microorganisms such as Cryptosporidium and Giardia, it is necessary to develop an alternative. Particle counts is a qualitative measurement of the amount of dissolved solids in water. The removal rate of particle counts was previously used as an indicator of the effectiveness of a biological activated carbon (BAC) filter in removing Cryptosporidium and Giardia. The particle counts in a BAC filter effluent over one operational period and the effects of BAC filter construction and operational parameters were investigated with a 10 m3/h pilot plant. The results indicated that the maximum particle count in backwash remnant water was as high as 1296 count/ml and it needed about 1.5 h to reduce from the maximum to less than 50 count/ml. During the standard filtration period, particle counts stay constant at less than 50 count/ml for 5 d except when influ- enced by sand filter backwash remnant water. The removal rates of particle counts in the BAC filter are related to characteristics of the carbon. For example, a columned carbon and a sand bed removed 33.3% and 8.5% of particles, respectively, while the particle counts in effluent from a cracked BAC filter was higher than that of the influent. There is no significant difference among particle removal rates with different filtration rates. High post-ozone dosage (>2 mg/L) plays an important role in particle count removal; when the dosage was 3 mg/L, the removal rates by carbon layers and sand beds decreased by 17.5% and increased by 9.5%, respectively, compared with a 2 mg/L dosage.