期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
The Determination of Iodide Based on a Flow-injection Coupling Irreversible Biamperometry 被引量:3
1
作者 Li Jun LI Hao CHENG +5 位作者 Wen Yi HUANG Hong Xing KONG Jian Ling WU Jian Ping LU Wei GAO Jun Feng SONG 《Chinese Chemical Letters》 SCIE CAS CSCD 2005年第12期1629-1632,共4页
A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of perm... A novel flow-injection irreversible biamperometric method is described for the direct determination of iodide. The method is based on electrochemical oxidation of iodide at the gold electrode and the reduction of permanganate at the platinum electrode to form an irreversible biamperometric detection system. Under the applied potential difference of 0 V, in the 0.05 mol/L sulfuric acid, iodidecan be determined over the range 4.00×10^-7-1.00×10^-5 mol/L with a sampling frequency of 120 samples per hour. The detection limit for I- is 3.0×10^-7 mol/L and the RSD for 40 replicate determinations of 4.0×10^-5 mol/L potassium iodide is 1.68%. The new method was applied to the analysis of iodide in table salt with satisfactory results. 展开更多
关键词 IODIDE flow injection irreversible biamperometry gold electrode platinum electrode
下载PDF
Determination of chlorogenic acid by flow injection irreversible biamperometry 被引量:3
2
作者 Li Jun Li Qi Feng Chen +5 位作者 Lai Bo Yu Zhao Heng Zhong Jun Feng Hao Cheng Hong Xing Kong Jian Ling Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2007年第4期431-434,共4页
A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum elec... A flow injection irreversible biamperometric method for the determination of chlorogenic acid is described. The proposed method is based on the electrochemical oxidation of chlorogenic acid at pretreated platinum electrode and the reduction of permanganate at another electrode to form an irreversible biamperometric detection system. Under the external potential difference (z^v) of 0 V, in the 0.05 mol/L sulfuric acid, chlorogenic acid can be determined over the range 0.8-120 mg/L with a sample measurement frequency of 80 samples/h. The detection limit is 0.18 mg/L. The proposed method exhibits the satisfactory reproducibility with a relative standard derivation (R.S.D.) of 2.21% for 19 successive determinations of 40 mg/L. 展开更多
关键词 Flow injection Irreversible biamperometry Chlorogenic acid HONEYSUCKLE
下载PDF
Determination of levodopa in pharmaceutical preparations by irreversible biamperometry 被引量:2
3
作者 Li Jun Li Qi Feng Chen +2 位作者 Hao Cheng Lai Bo Yu Jian Ling Wu 《Chinese Chemical Letters》 SCIE CAS CSCD 2008年第6期703-706,共4页
Based on the electrocatalytic oxidation of levodopa at gold electrode and the reduction of permanganate at platinum electrode, a novel flow injection irreversible biamperometric method is developed for the determinati... Based on the electrocatalytic oxidation of levodopa at gold electrode and the reduction of permanganate at platinum electrode, a novel flow injection irreversible biamperometric method is developed for the determination of levodopa under the potential difference of 0 V imposed between two electrodes. In H2SO4 solution, the linear relationships between currents and the concentrations of levodopa are obtained in the range from 0.04 mg/L to 20 mg/L with the detection limit of 0.012 mg/L. The proposed method is applied to the determination of levodopa in pharmaceutical preparations. 展开更多
关键词 Flow injection LEVODOPA Irreversible biamperometry Gold electrode Platinum electrode
下载PDF
Determination of Vitamin B_1 in Pharmaceutical Preparations by Flow-injection Analysis with Biamperometric Detection
4
作者 LI Li-jun CHENG Hao +1 位作者 ZHAO Chuan HU Xiao-ge 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2005年第6期650-653,共4页
A new electrochemical method for the on-line determination of vitamin B1 is presented. Based on dead-stop endpoint biamperometry by using two platinum foil electrodes with an applied potential difference of 150 mV, vi... A new electrochemical method for the on-line determination of vitamin B1 is presented. Based on dead-stop endpoint biamperometry by using two platinum foil electrodes with an applied potential difference of 150 mV, vitamin B1 can be oxidized by hexacyanoferrate ( Ⅲ ) in a sodium hydroxide medium via a reversible indicating couple Fe( CN)6^4- /Fe(CN)6^3- The cell current is linear with the concentration of vitamin B1 in the concentration range of 4. 0 × 10^-6-1.0 × 10^ -3 mol/L with a detection limit of 8.0 ×10 ^-7 mol/L(0. 27 μg/mL). Most familiar excipients, ions and vitamins do not interfere with the determination of vitamin B1. The method displays the advantages of simplicity, high efficiency( 180 samples/h), and high selectivity, and is suitable for the determination of vitamin B1 in pharmaceutical preparations. 展开更多
关键词 Pharmaceutical analysis biamperometry Vitamin B1 How-injection analysis
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部