期刊文献+
共找到87篇文章
< 1 2 5 >
每页显示 20 50 100
Optimization Design for Digital Binoculars
1
作者 CEN Jun-bo CHEN Wei-min LI Hui HUANG Shang-lian 《Semiconductor Photonics and Technology》 CAS 2005年第3期212-216,共5页
In order to develop competitive and high performance/cost ratio of digital binoculars, design scheme should be optimized in term of technical capacity, economic benefit, product performance, risk management, etc. The ... In order to develop competitive and high performance/cost ratio of digital binoculars, design scheme should be optimized in term of technical capacity, economic benefit, product performance, risk management, etc. The common optimization method is limited in qualitative analysis, and the parameter optimization method is limited in obtaining optimal parameter only from technical side. Each method has its limitation. Based on the analysis of digital binoculars parameters, optional design schemes are laid down. Analytic hierarchy process combined the qualitative analysis with the quantitative analysis together. The design schemes are optimized, and resuh is worked out. 展开更多
关键词 Digital binoculars Design scheme OPTIMIZATION
下载PDF
精彩触手可及 佳能BINOCULARS 15×50 IS AW双眼望远镜
2
《新潮电子》 2006年第9期68-69,共2页
4年一度的世界杯足球赛终于再度轮回,身为狂热球迷的佻,是否早已打点好行囊,准备亲临赛场感受那令人血脉贲张的热烈气氛,且慢,或许你漏掉了一样不可或缺的工具——望远镜,有了它的帮助,你才不会错过了偶像球星们每一个精妙射门... 4年一度的世界杯足球赛终于再度轮回,身为狂热球迷的佻,是否早已打点好行囊,准备亲临赛场感受那令人血脉贲张的热烈气氛,且慢,或许你漏掉了一样不可或缺的工具——望远镜,有了它的帮助,你才不会错过了偶像球星们每一个精妙射门的特写瞬间。 展开更多
关键词 望远镜 佳能binoculars 15×50 IS AW 世界杯足球赛
下载PDF
Frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students 被引量:1
3
作者 Jie Cai Wen-Wen Fan +5 位作者 Yun-Hui Zhong Cai-Lan Wen Xiao-Dan Wei Wan-Chen Wei Wan-Yan Xiang Jin-Mao Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期374-379,共6页
AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine visio... AIM:To investigate the frequency and associated factors of accommodation and non-strabismic binocular vision dysfunction among medical university students.METHODS:Totally 158 student volunteers underwent routine vision examination in the optometry clinic of Guangxi Medical University.Their data were used to identify the different types of accommodation and nonstrabismic binocular vision dysfunction and to determine their frequency.Correlation analysis and logistic regression were used to examine the factors associated with these abnormalities.RESULTS:The results showed that 36.71%of the subjects had accommodation and non-strabismic binocular vision issues,with 8.86%being attributed to accommodation dysfunction and 27.85%to binocular abnormalities.Convergence insufficiency(CI)was the most common abnormality,accounting for 13.29%.Those with these abnormalities experienced higher levels of eyestrain(χ2=69.518,P<0.001).The linear correlations were observed between the difference of binocular spherical equivalent(SE)and the index of horizontal esotropia at a distance(r=0.231,P=0.004)and the asthenopia survey scale(ASS)score(r=0.346,P<0.001).Furthermore,the right eye's SE was inversely correlated with the convergence of positive and negative fusion images at close range(r=-0.321,P<0.001),the convergence of negative fusion images at close range(r=-0.294,P<0.001),the vergence facility(VF;r=-0.234,P=0.003),and the set of negative fusion images at far range(r=-0.237,P=0.003).Logistic regression analysis indicated that gender,age,and the difference in right and binocular SE did not influence the emergence of these abnormalities.CONCLUSION:Binocular vision abnormalities are more prevalent than accommodation dysfunction,with CI being the most frequent type.Greater binocular refractive disparity leads to more severe eyestrain symptoms. 展开更多
关键词 optometry clinic non-strabismic binocular vision dysfunction college students convergence insufficiency
下载PDF
Comparison of vergence mechanisms between university students with good and poor sleep quality
4
作者 Pui Juan Woi Joyce Yi Ling Lu +1 位作者 Mohd Izzuddin Hairol Wan Nur Amirah Ibrahim 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期353-358,共6页
AIM:To compare the vergence mechanisms between good and poor sleepers in university students.METHODS:A total of 64 university students were recruited in this study.The validated Malay version of Pittsburgh Sleep Quali... AIM:To compare the vergence mechanisms between good and poor sleepers in university students.METHODS:A total of 64 university students were recruited in this study.The validated Malay version of Pittsburgh Sleep Quality Index questionnaire(PSQI-M)was used to measure the participants’sleep quality over the past month.Participants were categorized as good sleepers(n=32)and poor sleepers(n=32)based on the PSQI-M scores.Heterophoria and fusional vergences were measured at distance and near.Mann-Whitney U test was used to compare heterophoria,negative fusional vergence(NFV),and positive fusional vergence(PFV)at distance and near between good and poor sleepers.Spearman correlation analysis was used to study the relationship between PSQI-M score and PFV at distance.RESULTS:Both distance and near heterophorias were not significantly different between good and poor sleepers(P>0.05).There was a difference in distance PFV(P<0.05)between good and poor sleepers,but not in distance NFV,near NFV,and near PFV(P>0.05).Distance PFV was negatively correlated with PSQI-M score(rs=-0.33,P<0.05).CONCLUSION:University students with poor sleep quality demonstrates a reduced ability to maintain fusion with increasing convergence demand at distance.Sleep quality assessment during binocular vision examination in university students is recommended. 展开更多
关键词 binocular vision VERGENCE sleep quality university students
下载PDF
Assessment of the effects of induced anisometropia on binocularity with glasses-free 3D technique 被引量:1
5
作者 Xu-Bo Yang Wei-Dong Huang Yong-Chuan Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期601-607,共7页
AIM:To assess the effect of experimentally induced anisometropia on binocularity in normal adults with glassesfree three-dimensional(3D)technique.METHODS:Totally 54 healthy medical students with normal binocularity in... AIM:To assess the effect of experimentally induced anisometropia on binocularity in normal adults with glassesfree three-dimensional(3D)technique.METHODS:Totally 54 healthy medical students with normal binocularity in the cross-sectional study were enrolled.Anisometropia was induced by placing trail lenses over the right eye,in 0.5 D steps including lenses of-0.5,-1,-1.5,-2,-2.5 D(hyperopic anisometropia)and lenses of+0.5,+1,+1.5,+2,+2.5 D(myopic anisometropia).The glasses-free 3D technique was used to evaluated not only fine stereopsis,but also coarse stereopsis,dynamic stereopsis,foveal suppression,and peripheral suppression in these subjects.One-way analysis of variance was used to compare quantitative data such as fine stereopsis,coarse stereopsis.Pearson’s Chi-square test was performed to compare categorical data such as dynamic stereopsis,foveal suppression and peripheral suppression.RESULTS:The subjects showed a statistically significant decline in fine stereopsis,coarse stereopsis,and dynamic stereopsis with increasing levels of anisometropia(P<0.001).Binocularity was af fected when induced anisometropia was more than 1 D(P<0.05).Foveal suppression and peripheral suppression were evident and increased in proportion to anisometropia(P<0.001).CONCLUSION:The relatively low degrees of anisometropia may have a potentially significant effect on high-grade binocular interaction.The mechanisms underlying the defect of binocularity seem to involve not only foveal suppression,but also peripheral suppression. 展开更多
关键词 ANISOMETROPIA binocularity STEREOPSIS glasses-free 3D technique
下载PDF
Improvement of Binocular Reconstruction Algorithm for Measuring 3D Pavement Texture Using a Single Laser Line Scanning Constraint 被引量:1
6
作者 Yuanyuan Wang RuiWang +1 位作者 Xiaofeng Ren Junan Lei 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1951-1972,共22页
The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was... The dense and accurate measurement of 3D texture is helpful in evaluating the pavement function.To form dense mandatory constraints and improve matching accuracy,the traditional binocular reconstruction technology was improved threefold.First,a single moving laser line was introduced to carry out global scanning constraints on the target,which would well overcome the difficulty of installing and recognizing excessive laser lines.Second,four kinds of improved algorithms,namely,disparity replacement,superposition synthesis,subregion segmentation,and subregion segmentation centroid enhancement,were established based on different constraint mechanism.Last,the improved binocular reconstruction test device was developed to realize the dual functions of 3D texture measurement and precision self-evaluation.Results show that compared with traditional algorithms,the introduction of a single laser line scanning constraint is helpful in improving the measurement’s accuracy.Among various improved algorithms,the improvement effect of the subregion segmentation centroid enhancement method is the best.It has a good effect on both overall measurement and single pointmeasurement,which can be considered to be used in pavement function evaluation. 展开更多
关键词 3D pavement texture binocular reconstruction algorithm single laser line scanning constraint improved stereo matching
下载PDF
Comparison of visual performance with iTrace analyzer following femtosecond laser-assisted cataract surgery with bilateral implantation of two different trifocal intraocular lenses 被引量:1
7
作者 Rui-Hong Ju Hao-Kun Qu +4 位作者 Zhe-Ming Wu Yun Chen Li-Nan Wu Yuan Long Zheng Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1773-1781,共9页
AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffract... AIM:To compare the postoperative binocular visual performance with an iTrace analyzer following femtosecond laser-assisted cataract surgery(FLACS)combined with bilateral implantation of two different types of diffractive trifocal intraocular lenses(IOL).METHODS:During this retrospective observational study,patients who received bilateral FLACS combined with implantation of two different types of diffractive trifocal IOLs were evaluated.According to the IOLs’different types and design,the patients were divided into AT LISA tri839MP group(tri839 group)and AcrySof PanOptix TFNT00 group(TFNT group).Study parameters included preoperative and postoperative uncorrected distance visual acuity(UDVA)at 5 m,uncorrected near visual acuity(UNVA)at 30 cm and 40 cm,uncorrected intermediate visual acuity(UIVA)at 60 cm and 80 cm,postoperative refractive status,objective visual qualities and total high order aberrations(HOAs)postoperatively.The postoperative complications were also recorded.RESULTS:Totally 56 eyes of 28 patients(tri839 group,n=26;TFNT group,n=30)were included.Preoperative baseline characteristics between groups were not statistically significantly different.UDVA was not significantly different between groups except for 1wk follow-up due to the postoperative corneal edema.TFNT group showed statistically significant better UNIA at 60 cm than tri839 group at the 1wk(0.05±0.19 vs 0.15±0.10 logMAR,P=0.013),1mo(0.05±0.12 vs 0.15±0.09 logMAR,P=0.001)and 3mo(0.04±0.12 vs 0.15±0.11 logMAR,P=0.001)follow-up,while tri839 group showed statistically significant better UNIA at 80 cm than TFNT group at the 1d(0.14±0.15 vs 0.20±0.14 logMAR,P=0.041)and 1mo(0.09±0.07 vs 0.14±0.10 logMAR,P=0.042)follow-up.Postoperative refractive status showed stable at every visit.Modulated transfer function(MTF)values and strehl ratio(SR)values were improved and HOAs were lower significantly after surgery.CONCLUSION:FLACS with bilateral implantations of both tri839 and TFNT00 can achieve satisfactory natural whole-course vision,high postoperative refractive stability and good visual quality but without significantly difference.iTrace aberration instrument can accurately evaluate the visual quality under different status. 展开更多
关键词 femtosecond laser-assisted cataract surgery visual performance BINOCULAR AT LISA tri839MP AcrySof PanOptix TFNT00 iTrace
下载PDF
Hawk‐eye‐inspired perception algorithm of stereo vision for obtaining orchard 3D point cloud navigation map 被引量:1
8
作者 Zichao Zhang Jian Chen +2 位作者 Xinyu Xu Cunjia Liu Yu Han 《CAAI Transactions on Intelligence Technology》 SCIE EI 2023年第3期987-1001,共15页
The binocular stereo vision is the lowest cost sensor for obtaining 3D information.Considering the weakness of long‐distance measurement and stability,the improvement of accuracy and stability of stereo vision is urg... The binocular stereo vision is the lowest cost sensor for obtaining 3D information.Considering the weakness of long‐distance measurement and stability,the improvement of accuracy and stability of stereo vision is urgently required for application of precision agriculture.To address the challenges of stereo vision long‐distance measurement and stable perception without hardware upgrade,inspired by hawk eyes,higher resolution perception and the adaptive HDR(High Dynamic Range)were introduced in this paper.Simulating the function from physiological structure of‘deep fovea’and‘shallow fovea’of hawk eye,the higher resolution reconstruction method in this paper was aimed at ac-curacy improving.Inspired by adjustment of pupils,the adaptive HDR method was proposed for high dynamic range optimisation and stable perception.In various light conditions,compared with default stereo vision,the accuracy of proposed algorithm was improved by 28.0%evaluated by error ratio,and the stability was improved by 26.56%by disparity accuracy.For fixed distance measurement,the maximum improvement was 78.6%by standard deviation.Based on the hawk‐eye‐inspired perception algorithm,the point cloud of orchard was improved both in quality and quantity.The hawk‐eye‐inspired perception algorithm contributed great advance in binocular 3D point cloud recon-struction in orchard navigation map. 展开更多
关键词 adaptive high dynamic range binocular stereo vision hawk‐eye‐inspired perception point cloud of orchard super‐resolution generative adversarial network
下载PDF
Fast Estimation of Loader’s Shovel Load Volume by 3D Reconstruction of Material Piles
9
作者 Binyun Wu Shaojie Wang +2 位作者 Haojing Lin Shijiang Li Liang Hou 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第5期187-205,共19页
Fast and accurate measurement of the volume of earthmoving materials is of great signifcance for the real-time evaluation of loader operation efciency and the realization of autonomous operation. Existing methods for ... Fast and accurate measurement of the volume of earthmoving materials is of great signifcance for the real-time evaluation of loader operation efciency and the realization of autonomous operation. Existing methods for volume measurement, such as total station-based methods, cannot measure the volume in real time, while the bucket-based method also has the disadvantage of poor universality. In this study, a fast estimation method for a loader’s shovel load volume by 3D reconstruction of material piles is proposed. First, a dense stereo matching method (QORB–MAPM) was proposed by integrating the improved quadtree ORB algorithm (QORB) and the maximum a posteriori probability model (MAPM), which achieves fast matching of feature points and dense 3D reconstruction of material piles. Second, the 3D point cloud model of the material piles before and after shoveling was registered and segmented to obtain the 3D point cloud model of the shoveling area, and the Alpha-shape algorithm of Delaunay triangulation was used to estimate the volume of the 3D point cloud model. Finally, a shovel loading volume measurement experiment was conducted under loose-soil working conditions. The results show that the shovel loading volume estimation method (QORB–MAPM VE) proposed in this study has higher estimation accuracy and less calculation time in volume estimation and bucket fll factor estimation, and it has signifcant theoretical research and engineering application value. 展开更多
关键词 LOADER Volume estimation Binocular stereo vision 3D terrain reconstruction Point cloud registration and segmentation
下载PDF
Effect of visual perception training on binocular visual function reconstruction in patients after strabismus surgery
10
作者 Yu Su Fei Wang +1 位作者 Tao Wang Qin-Mei Wang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第10期1657-1661,共5页
AIM:To explore the effect of visual perception learning software training(VPT)on binocular visual function reconstruction in children with intermittent exotropia after strabismus surgery.METHODS:Ninety children with i... AIM:To explore the effect of visual perception learning software training(VPT)on binocular visual function reconstruction in children with intermittent exotropia after strabismus surgery.METHODS:Ninety children with intermittent exotropia admitted to our hospital from June 2018 to December 2018 were included,and randomly divided into VPT and control groups.Children in the control group received basic binocular vision training,while those in the VPT group received VPT after strabismus surgery.Tertiary visual function,visual perception function,Newcastle Control Score(NCS),and ocular position retraction rate were compared at 3 and 12mo after the surgery.RESULTS:At 3 and 12mo after the surgery,the proportion of simultaneous perception,binocular fusion version and binocular stereo vision in the VPT group was conspicuously higher than that in the control group(P<0.05).After the vision training,the binocular visual perception functions of children in both groups were significantly improved compared with that before training(P<0.05).Interestingly,the grating sharpness,texture perception and texture motion perception in the VPT group were dramatically better than control group(P<0.01).The NCS in the VPT group was significantly lower than that in the control group(P<0.05).The ocular position retraction rate in the VPT group was significantly lower than that in the control group at 12mo(8.89%vs 26.67%,P=0.03).CONCLUSION:VPT effectively promotes binocular visual function reconstruction in intermittent exotropia children after strabismus surgery and reduces the strabismus severity and ocular position retraction rate. 展开更多
关键词 CHILDREN intermittent exotropia visual perception training ocular position binocular visual function
下载PDF
双目定位多功能机械臂系统设计
11
作者 于聪 张豪 +1 位作者 赵振儒 谢印忠 《人工智能与机器人研究》 2023年第2期39-47,共9页
准确性、快速性与鲁棒性是机械臂系统设计的要求,经过研究提出一套新形式的机器人视觉系统,利用非接触式测量,对所操控单元进行位姿计算,完成操控单元的三维信息与机械臂执行单元进行命令交互。设计采用双目CMOS工业相机,通过Matlab进... 准确性、快速性与鲁棒性是机械臂系统设计的要求,经过研究提出一套新形式的机器人视觉系统,利用非接触式测量,对所操控单元进行位姿计算,完成操控单元的三维信息与机械臂执行单元进行命令交互。设计采用双目CMOS工业相机,通过Matlab进行相机标定并得到内外参数,然后进行立体校正,结合SGBM立体匹配算法解算出位置深度信息,进而对应帧的二维图像,利用OpenCV视觉算法获取操控器下端标志物的三维坐标,传递执行指令给机械部控制单元。由实验结果分析,在白光环境下该机器人系统同步现实功能展现出良好的跟随准确性,精度误差始终保持在4.5%以内,命令响应时间短,鲁棒性好。 展开更多
关键词 Design of Binocular Positioning Multifunctional Manipulator System
下载PDF
基于双目立体视觉技术的无人化自动装载机研究 被引量:2
12
作者 刘晓红 文怀兴 《机械设计与制造》 北大核心 2010年第12期154-156,共3页
具有双目立体视觉技术的无人化自动装载机不仅具备自动识别作业对象物,自行规划运动轨迹及控制执行单元完成作业任务的能力,还可自行装载,倾倒时无需掉头,来回行走路径简单,大大提高了工作效率、减轻了劳动强度并增加了每次搬运的容量,... 具有双目立体视觉技术的无人化自动装载机不仅具备自动识别作业对象物,自行规划运动轨迹及控制执行单元完成作业任务的能力,还可自行装载,倾倒时无需掉头,来回行走路径简单,大大提高了工作效率、减轻了劳动强度并增加了每次搬运的容量,极大的拓展了装载机的应用领域,具有重要的社会经济效益。 展开更多
关键词 双目 立体视觉技术 无人化 自动识别 装载机 technology BINOCULAR STEREO VISION based 社会经济效益 作业任务 执行单元 运动轨迹 行走路径 劳动强度 工作效率 对象物 容量 倾倒 能力 控制
下载PDF
REAL-TIME STEREO MATCHING ALGORITHM IN PHOTODYNAMIC THERAPY BINOCULAR SURVEILLANCE SYSTEM FOR PORT WINE STAIN
13
作者 唐晓英 应龙 刘伟峰 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2010年第1期45-50,共6页
A stereo matching algorithm based on the epipolar line constraint is designed to meet the real-time and the accuracy requirements. The algorithm is applied to photodynamic therapy binocular surveillance system for por... A stereo matching algorithm based on the epipolar line constraint is designed to meet the real-time and the accuracy requirements. The algorithm is applied to photodynamic therapy binocular surveillance system for port wine stain (PWS) when it monitors the position of the treatment region. The corner matching based on Hu moments is used to calculate the fundamental matrix of the binocular vision system. Experimental results are in agreement with the theoretical calculation. 展开更多
关键词 ROBOTS binocular vision system stereo matching Hu moments
下载PDF
Measurement method for cluster warhead's dispersion area based on binocular stereo vision technique
14
作者 薛英娟 郝利华 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第2期123-128,共6页
Cluster warhead has become the main ammunition of gun,rocket projectile and missile and it has been widely equipped in almost every country.More and more attention is paid to the damage effect of cluster warhead.The s... Cluster warhead has become the main ammunition of gun,rocket projectile and missile and it has been widely equipped in almost every country.More and more attention is paid to the damage effect of cluster warhead.The size of the dispersion area of cluster warhead is the main standard by which the damage effect of cluster warhead is estimated.The practical method of measuring the dispersion area was developed based on binocular stereo vision measurement theory.The calibration principle of the binocular stereo vision cameras was studied.The matching algorithm that relies on the gradient fields of the neighborhood of a pixel has been used to obtain the spatial information of matched points by acquiring apair of corresponding points in the left and right images of binocular cameras.The 3Dpositions of the flying path of cluster warhead were calculated.The umbrella that is similar to the dispersion track of static explosive cluster warhead was applied in the experiment to get the projection area of the umbrella on the ground.Experiment results verify the feasibility of the proposed method. 展开更多
关键词 binocular stereo vision cluster warhead dispersion area
下载PDF
Three-Dimensional Reconstruction of Welding Pool Surface by Binocular Vision 被引量:7
15
作者 Zunan Gu Ji Chen Chuansong Wu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2021年第3期272-284,共13页
Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate ... Current research of binocular vision systems mainly need to resolve the camera’s intrinsic parameters before the reconstruction of three-dimensional(3D)objects.The classical Zhang’calibration is hardly to calculate all errors caused by perspective distortion and lens distortion.Also,the image-matching algorithm of the binocular vision system still needs to be improved to accelerate the reconstruction speed of welding pool surfaces.In this paper,a preset coordinate system was utilized for camera calibration instead of Zhang’calibration.The binocular vision system was modified to capture images of welding pool surfaces by suppressing the strong arc interference during gas metal arc welding.Combining and improving the algorithms of speeded up robust features,binary robust invariant scalable keypoints,and KAZE,the feature information of points(i.e.,RGB values,pixel coordinates)was extracted as the feature vector of the welding pool surface.Based on the characteristics of the welding images,a mismatch-elimination algorithm was developed to increase the accuracy of image-matching algorithms.The world coordinates of matching feature points were calculated to reconstruct the 3D shape of the welding pool surface.The effectiveness and accuracy of the reconstruction of welding pool surfaces were verified by experimental results.This research proposes the development of binocular vision algorithms that can reconstruct the surface of welding pools accurately to realize intelligent welding control systems in the future. 展开更多
关键词 Surface reconstruction Welding pool Binocular imaging Gas metal arc welding Feature points matching
下载PDF
Clinical investigation of surgery for intermittent exotropia 被引量:8
16
作者 Chong-qing YANG Ye SHEN Yang-shun GU Wei HAN 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2008年第6期470-473,共4页
Objective: To investigate the time and postoperative binocular vision of strabismus surgery for children with intermittent exotropia (X(T)). Methods: A retrospective investigation was conducted in 80 child patie... Objective: To investigate the time and postoperative binocular vision of strabismus surgery for children with intermittent exotropia (X(T)). Methods: A retrospective investigation was conducted in 80 child patients with intermittent exotropia. Pre- and postoperative angles of deviation fixating at near (33 cm) and distant targets (6 m) were measured with the prolonged alternate cover testing. The binocular function was assessed with synoptophore. Twenty-one patients took the postoperative synoptophore exercise. Results: (1) A week after surgery, 96.2% of the 80 patients had binocular normotopia, while a year after surgery, 91.3% of the 80 patients had binocular normotopia; (2) Preoperatively, 58 patients had near stereoacuity, while postoperatively, 72 patients achieved near stereoacuity (P〈0.05); (3) Preoperatively, 64 patients had Grade Ⅰ for the synoptophore evaluation and postoperatively, 76 patients achieved Grade Ⅰ. Meanwhile, 55 patients had Grade Ⅱ preoperatively and 72 achieved Grade Ⅱ postoperatively. For Grade Ⅲ, there were 49 patients preoperatively and 64 patients postoperatively (P〈0.05); (4) Patients of 5-8 years old had a significantly better recovery rate of binocular vision than those of 9-18 years old (P〈0.05); (5) Patients taking postoperative synoptophore exercise had a better binocular vision than those taking no exercise (P〈0.05). Conclusions: (1) Strabismus surgery can help to preserve or restore the binocular vision for intermittent exotropia; (2) Receiving the surgery at young ages may develop better postoperative binocular vision; (3) The postoperative synoptophore exercise can help to restore the binocular vision. 展开更多
关键词 Intermittent exotropia (X(T)) SURGERY Binocular vision
下载PDF
Symptomatic accommodative and binocular dysfunctions from the use of flat-panel displays 被引量:5
17
作者 Esteban Porcar Juan Carlos Montalt +1 位作者 Alvaro M. Pons Enrique Espana-Gregor 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期501-505,共5页
AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: ... AIM: To determine the presence of symptomatic accommodative and non-strabismic binocular dysfunctions (A.sBD) in a non-presbyopic population of video display unit (VDU) users with flat-panel displays. METHODS: One hundred and one VDU users, aged between 20 to 34y, initially participated in the study. This study excluded contact-lens wearers and subjects who had undergone refractive surgery or had any systemic or ocular disease. First, subjects were asked about the type and nature of eye symptoms they experienced during VDU use. Then, a thorough eye examination excluded those subjects with a significant uncorrected refractive error or other problem, such as ocular motility disorders, vertical deviation, strabismus and eye diseases. Finally, the remaining participants underwent an exhaustive assessment of their accommodative and binocular vision status. RESULTS: Eighty-nine VDU users (46 females and 43 males) were included in this study. They used flat-panel displays for an average of 5±1.9h a day. Twenty subjects presented A.sBD (22.5%). Convergence excess was the most frequent non-strabismic binocular dysfunction (9 subjects), followed by fusional vergence dysfunction (3 subjects) and convergence insufficiency (2 subjects). Within the accommodative dysfunctions, accommodative excess was the most common (4 subjects), followed by accommodative insufficiency (2 subjects). Moderate to severe eye symptoms were found in 13 subjects with ANSBD. CONCLUSION: Significant eye symptoms in VDU users with accommodative and/or non-strabismic binocular dysfunctions often occur and should not be underestimated; therefore, an appropriate evaluation of accommodative and binocular vision status is more important for this population, 展开更多
关键词 general binocular dysfunctions accommodativedysfunctions non-strabismic binocular dysfunctions eyesymptoms video display unit
下载PDF
Advances in optical engineering for future telescopes 被引量:14
18
作者 Daewook Kim Heejoo Choi +8 位作者 Trenton Brendel Henry Quach Marcos Esparza Hyukmo Kang Yi-Ting Feng Jaren NAshcraft Xiaolong Ke Tianyi Wang Ewan SDouglas 《Opto-Electronic Advances》 SCIE 2021年第6期20-43,共24页
Significant optical engineering advances at the University of Arizona are being made for design, fabrication, and construction of next generation astronomical telescopes. This summary review paper focuses on the techn... Significant optical engineering advances at the University of Arizona are being made for design, fabrication, and construction of next generation astronomical telescopes. This summary review paper focuses on the technological advances in three key areas. First is the optical fabrication technique used for constructing next-generation telescope mirrors. Advances in ground-based telescope control and instrumentation comprise the second area of development. This includes active alignment of the laser truss-based Large Binocular Telescope(LBT) prime focus camera, the new MOBIUS modular cross-dispersion spectroscopy unit used at the prime focal plane of the LBT, and topological pupil segment optimization. Lastly, future space telescope concepts and enabling technologies are discussed. Among these, the Nautilus space observatory requires challenging alignment of segmented multi-order diffractive elements. The OASIS terahertz space telescope presents unique challenges for characterizing the inflatable primary mirror, and the Hyperion space telescope pushes the limits of high spectral resolution, far-UV spectroscopy. The Coronagraphic Debris and Exoplanet Exploring Pioneer(CDEEP) is a Small Satellite(Small Sat) mission concept for high-contrast imaging of circumstellar disks and exoplanets using vector vortex coronagraph. These advances in optical engineering technologies will help mankind to probe, explore, and understand the scientific beauty of our universe. 展开更多
关键词 computer controlled optical surfacing CCOS multiplexing dwell time optimization optical metrology telescope alignment large binocular telescope MOBIUS pupil segmentation OASIS NAUTILUS HYPERION CDEEP vector vortex coronagraph
下载PDF
An Active Stereo Vision System Based on Neural Pathways of Human Binocular Motor System 被引量:3
19
作者 Yu-zhang Gu Makoto Sato Xiao-lin Zhang 《Journal of Bionic Engineering》 SCIE EI CSCD 2007年第4期185-192,共8页
An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their ... An active stereo vision system based on a model of neural pathways of human binocular motor system is proposed. With this model, it is guaranteed that the two cameras of the active stereo vision system can keep their lines of sight fixed on the same target object during smooth pursuit. This feature is very important for active stereo vision systems, since not only 3D reconstruction needs the two cameras have an overlapping field of vision, but also it can facilitate the 3D reconstruction algorithm. To evaluate the effectiveness of the proposed method, some software simulations are done to demonstrate the same target tracking characteristic in a virtual environment apt to mistracking easily. Here, mistracking means two eyes track two different objects separately. Then the proposed method is implemented in our active stereo vision system to perform real tracking task in a laboratory scene where several persons walk self-determining. Before the proposed model is implemented in the system, mistracking occurred frequently. After it is enabled, mistracking never occurred. The result shows that the vision system based on neural pathways of human binocular motor system can reliably avoid mistracking. 展开更多
关键词 binocular motor system neural pathway GAZE mistracking
下载PDF
Clinical efflcacy of botulinum toxin type A on acute acquired comitant esotropia 被引量:4
20
作者 Xiao-Qi Huang Xue-Min Hu +3 位作者 Yi-Jia Zhao Mei-Hong Ye Bei-Xi Yi Lian-Hong Zhou 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第11期1845-1851,共7页
AIM: To investigate the effects of micro-injection of botulinum toxin A(BTXA) on acute acquired comitant esotropia(AACE). METHODS: A total of 33 AACE patients who underwent BTXA micro-injection at Renmin Hospital of W... AIM: To investigate the effects of micro-injection of botulinum toxin A(BTXA) on acute acquired comitant esotropia(AACE). METHODS: A total of 33 AACE patients who underwent BTXA micro-injection at Renmin Hospital of Wuhan University from September 1^(st), 2019 to July 1^(st), 2021 were retrospective analyzed. Esotropia, eye alignment, stereopsis, and complications were examined at baseline(except complications), 1wk, 1, 3, and 6mo after injection. RESULTS: The average angle of deviation before injection was(+20.24±6.80)^(Δ) at near and(+24.76±6.43)^(Δ) at distance, while(+5.15±5.85)^(Δ) at near and(+7.30±6.17)^(Δ) at distance 6mo after treatment(P<0.05). Six months after injection, the stereopsis of patients had improved. The number of patients having no stereopsis(>800 seconds of arc) decreased from 11 to 3. The number of patients having peripheral stereopsis(300-800 seconds of arc), macular stereopsis(70-200 seconds of arc) and central concave stereopsis(≤60 seconds of arc) increased from 10 to 11, 10 to 12, and 2 to 7, respectively. At the follow-ups at 1wk, 1, 3, and 6mo after injection, success rates were 96.97%, 96.97%, 93.94% and 87.88%, respectively. One week after injection, two patients(6.07%) showed subconjunctival hemorrhage;three patients(9.09%) showed limited eye movement and one patient(3.03%) showed mild vertical strabismus. All the symptoms disappeared by the final follow-up.CONCLUSION: Micro-injection of BTXA can reduce diplopia and improve binocular vision function of AACE patients. Furthermore, the operation is relatively safe with few complications, making it an ideal treatment modality for AACE. 展开更多
关键词 acute acquired comitant esotropia botulinum toxin A binocular visual function STEREOPSIS DIPLOPIA
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部