Peatlands are unique and complex natural ecosystems that are part of the most important carbon reservoirs on our planet, home to a diversity of microorganisms responsible for fermentation, humification or peat. The ai...Peatlands are unique and complex natural ecosystems that are part of the most important carbon reservoirs on our planet, home to a diversity of microorganisms responsible for fermentation, humification or peat. The aim is to understand chemical and biological indicators of peatland soils. This work aims to determine the physicochemical and bacteriological profile and lipolytic activity of soil bacteria in Bilanko peatlands. The bacterial profile with the production of lipases is carried out by classical microbiology techniques. The results show that the soils are moderately acidic with temperatures of 27.8˚C ± 0.01˚C for Bilanko and 27.1˚C ± 0.57˚C for Ngamakala. The electroconductivity (EC) varies from (9.52 ± 0.002) μS/cm to (39.01 ± 1.4) μS/cm with low turbidity of (2.04 ± 0.66) mg/L to (31.02 ± 0.84) mg/L and low ion concentrations with, however, a richness in phenolic compounds for Bilanko compared to Ngamakala. FMAT diversity ranged from (1.71 ± 0.88)∙104 UFC/g to (2.92 ± 0.07)∙105 UFC/g for Bilanko and (1.30 ± 0.73)∙104 UFC/g to (2.89 ± 0.06)∙104 UFC/g for Ngamakala. Bacillus loads ranged from (5.20 ± 1.40)∙103 CFU/g to (1.22 ± 0.13)∙104 CFU/g and from (1.11 ± 0.13)∙104 CFU/g to (9.20 ± 2.05)∙103 CFU/g;enterobacteria loads from (1.40 ± 0.76)∙103 CFU/g to (8.80 ± 1.73)∙103 CFU/g and from (1.01 ± 0.02)∙103 CFU/g to (9.20 ± 2.05)∙103 CFU/g;in Pseudomonas from 0 to (2.30 ± 0.53)∙102 CFU/g and from 0 to (8.90 ± 2.35)∙102 CFU/g for Bilanko and Ngamakala respectively. These results reveal a variation in bacterial similarity and distribution in the Bilanko and Ngamakala peat bogs.展开更多
液化天然气(LNG)储存运输过程中产生的闪蒸气(boil off gas,BOG)具有一定的安全隐患。本文基于前人关于BOG的研究,查阅大量文献,对BOG的主要组成、产生原因和环境影响进行归纳整理,对以往的传统处理工艺以及新型处理工艺进行总结分析,...液化天然气(LNG)储存运输过程中产生的闪蒸气(boil off gas,BOG)具有一定的安全隐患。本文基于前人关于BOG的研究,查阅大量文献,对BOG的主要组成、产生原因和环境影响进行归纳整理,对以往的传统处理工艺以及新型处理工艺进行总结分析,对减少BOG排放量的相关措施进行评述,并总结目前已经得到应用的新技术,以期为今后更高效地利用BOG提供参考。展开更多
The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refri...The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.展开更多
文摘Peatlands are unique and complex natural ecosystems that are part of the most important carbon reservoirs on our planet, home to a diversity of microorganisms responsible for fermentation, humification or peat. The aim is to understand chemical and biological indicators of peatland soils. This work aims to determine the physicochemical and bacteriological profile and lipolytic activity of soil bacteria in Bilanko peatlands. The bacterial profile with the production of lipases is carried out by classical microbiology techniques. The results show that the soils are moderately acidic with temperatures of 27.8˚C ± 0.01˚C for Bilanko and 27.1˚C ± 0.57˚C for Ngamakala. The electroconductivity (EC) varies from (9.52 ± 0.002) μS/cm to (39.01 ± 1.4) μS/cm with low turbidity of (2.04 ± 0.66) mg/L to (31.02 ± 0.84) mg/L and low ion concentrations with, however, a richness in phenolic compounds for Bilanko compared to Ngamakala. FMAT diversity ranged from (1.71 ± 0.88)∙104 UFC/g to (2.92 ± 0.07)∙105 UFC/g for Bilanko and (1.30 ± 0.73)∙104 UFC/g to (2.89 ± 0.06)∙104 UFC/g for Ngamakala. Bacillus loads ranged from (5.20 ± 1.40)∙103 CFU/g to (1.22 ± 0.13)∙104 CFU/g and from (1.11 ± 0.13)∙104 CFU/g to (9.20 ± 2.05)∙103 CFU/g;enterobacteria loads from (1.40 ± 0.76)∙103 CFU/g to (8.80 ± 1.73)∙103 CFU/g and from (1.01 ± 0.02)∙103 CFU/g to (9.20 ± 2.05)∙103 CFU/g;in Pseudomonas from 0 to (2.30 ± 0.53)∙102 CFU/g and from 0 to (8.90 ± 2.35)∙102 CFU/g for Bilanko and Ngamakala respectively. These results reveal a variation in bacterial similarity and distribution in the Bilanko and Ngamakala peat bogs.
文摘液化天然气(LNG)储存运输过程中产生的闪蒸气(boil off gas,BOG)具有一定的安全隐患。本文基于前人关于BOG的研究,查阅大量文献,对BOG的主要组成、产生原因和环境影响进行归纳整理,对以往的传统处理工艺以及新型处理工艺进行总结分析,对减少BOG排放量的相关措施进行评述,并总结目前已经得到应用的新技术,以期为今后更高效地利用BOG提供参考。
文摘The present study aims to make a thermodynamic analysis of an ethylene cascade re-liquefaction system that consists of the following two subsystems: a liquefaction cycle using ethylene as the working fluid and a refrigeration cycle operating with a hydrocarbon refrigerant. The hydrocarbon refrigerants considered are propane(R290), butane(R600), isobutane(R600a), and propylene(R1270). A computer program written in FORTRAN is developed to compute parameters for characteristic points of the cycles and the system's performance, which is determined and analyzed using numerical solutions for the refrigerant condensation temperature, temperature in tank, and temperature difference in the cascade condenser. Results show that R600 a gives the best performance, followed by(in order) R600, R290, and R1270. Furthermore, it is found that an increase in tank temperature improves system performance but that an increase in refrigerant condensation temperature causes deterioration. In addition, it is found that running the system at a low temperature difference in the cascade condenser is advantageous.