Recovery of carbon monoxide from flue gases by selective absorption of carbon monoxide in an imidazolium chlorocuprate(l) ionic liquid is considered in this work as an alternative to the use of molecular volatile so...Recovery of carbon monoxide from flue gases by selective absorption of carbon monoxide in an imidazolium chlorocuprate(l) ionic liquid is considered in this work as an alternative to the use of molecular volatile solvents such as aromatic hydrocarbons. The present work evaluates the CO mass transfer rates from the gas phase to the ionic liquid solutions in the absence of chemical reaction. To that end, carbon dioxide was employed as an inert model gas and absorption experiments were performed to assess the influence of different process variables in a batch reactor with fiat gas-liquid interface. The experimental mass transfer coefficients showed significant var- iation with temperature, (3.4-10.9) × 10^-7 m·s^-1 between 293 and 313 K; stirring speed, (10.2- 33.1)× 10^-7 m.s 1 between 100 and 300 r·min^-1; and concentration of copper(1), (6.6-10.2) × 10^-7 m·s^-1 between 0.25 and 2 mol· L^- 1. In addition, the mass transfer coefficients were eventually found to follow a poten- tial proportionality of the type kL ∝μ^-0.5 and the dimensionless correlation that makes the estimation of the mass transfer coefficients possible in the studied range of process variables was obtained: Sh=10^-2.64 Re^1.07 , Sc^0.75,These results constitute the first step in the kinetic analysis of the reaction between CO and imidazolium chlorocuprate(I) ionic liquid that determines the design of the separation units.展开更多
This paper describes the application of ultrasound waves on hydrodynamics and mass transfer characteristics in the gas–liquid flow in a T-shape microreactor with a diameter of 800 μm. A 1.7 MHz piezoelectric transdu...This paper describes the application of ultrasound waves on hydrodynamics and mass transfer characteristics in the gas–liquid flow in a T-shape microreactor with a diameter of 800 μm. A 1.7 MHz piezoelectric transducer(PZT) was employed to induce the vibration in this microreactor. Liquid side volumetric mass transfer coefficients were measured by physical and chemical methods of CO_2 absorption into water and Na OH solution. The approach of absorption of CO_2 into a 1 mol·L^(-1) Na OH solution was used for analysis of interfacial areas. With the help of a photography system, the fluid flow patterns inside the microreactor were analyzed. The effects of superficial liquid velocity, initial concentration of Na OH, superficial CO_2 gas velocity and length of microreactor on the mass transfer rate were investigated. The comparison between sonicated and plain microreactors(microreactor with and without ultrasound) shows that the ultrasound wave irradiation has a significant effect on kLa and interfacial area at various operational conditions. For the microreactor length of 12 cm, ultrasound waves improved kLa and interfacial area about 21% and 22%, respectively. From this study, it can be concluded that ultrasound wave irradiation in microreactor has a great effect on the mass transfer rate. This study suggests a new enhancement technique to establish high interfacial area and kLa in microreactors.展开更多
The hydrodynamics and mass transfer characteristics of a lab-scale jet bubbling reactor(JBR)including the gas holdup,volumetric mass transfer coefficient and specific interfacial area were assessed experimentally inve...The hydrodynamics and mass transfer characteristics of a lab-scale jet bubbling reactor(JBR)including the gas holdup,volumetric mass transfer coefficient and specific interfacial area were assessed experimentally investigating the influence of temperature,pH and superficial gas velocity.The reactor diameter and height were 11 and 30 cm,respectively.It was equipped with a single sparger,operating at atmospheric pressure,20 and 40℃,and two pH values of 3 and 6.The height of the liquid was 23 cm,while the superficial gas velocity changed within 0.010-0.040 m·s^(-1)range.Experiments were conducted with pure oxygen as the gas phase and saturated lime solution as the liquid phase.The liquid-side volumetric mass transfer coefficient was determined under unsteady-state oxygen absorption in a saturated lime solution.The gas holdup was calculated based on the liquid height change,while the specific interfacial area was obtained by a physical method based on the bubble size distribution(BSD)in different superficial gas velocities.The results indicated that at the same temperature but different pH,the gas holdup variation was negligible,while the liquid-side volumetric mass transfer coefficient at the pH value of 6 was higher than that at the pH=3.At a constant pH but different temperatures,the gas holdup and the liquid-side volumetric mass transfer coefficients at 40℃were higher than that of the same at 20℃.A reasonable and appropriate estimation of the liquid-side volumetric mass transfer coefficient(kla)in a pilot-scale JBR was provided which can be applied to the design and scale-up of JBRs.展开更多
A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is co...A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is consisted of span80 [ sorbitian monooleate], paraffin oil, D2EHPA [ 2-( 2-ethylhexyl- phosphonic acid)], kerosene as well as HCl solution. The extraction under various conditions such as the span80 concentrations, the flow rate of aqueous, the extraction time and HCl concentrations in receiving phase were studied. Results show that the lower the flow rates of aqueous are, the higher the extraction percentage and enrichment-fold are, and the extraction percentage increases with the increasing of HCl concentrations. When the initial Nd^3+ concentration in feed is maintained at 1000 mg· L^-1 and the emulsion is recycled with 70 times by a counter-flow,展开更多
A pore-array intensified tube-in-tube microchannel(PA-TMC),which is characterized by high throughput and low pressure drop,was developed as a gas–liquid contactor.The sulfite oxidation method was used to determine th...A pore-array intensified tube-in-tube microchannel(PA-TMC),which is characterized by high throughput and low pressure drop,was developed as a gas–liquid contactor.The sulfite oxidation method was used to determine the oxygen efficiency(φ)and volumetric mass transfer coefficient(k_(L)a)of PA-TMC,and the mass transfer amount per unit energy(ε)was calculated by using the pressure drop.The effects of structural and operating parameters were investigated systematically,and the twophase flow behavior was monitored by using a charge-coupled device imaging system.The results indicated that the gas absorption efficiency and mass transfer performance of the PA-TMC were improved with increasing pore number,flow rate,and number of helical coil turns and decreasing pore size,row number,annular size,annular length,and surface tension.Theφ,εand k La of PA-TMC could reach 31.3%,1.73×10^(-4) mol/J,and 7.0 s-1,respectively.The Sherwood number was correlated with the investigated parameters to guide the design of PA-TMC in gas absorption and mass transfer processes.展开更多
A mass transfer model for devolatilization process of highly viscous media in rotating packed bed(RPB) was developed based on penetration theory and mass conservation.Before establishing the model,some mass transfer e...A mass transfer model for devolatilization process of highly viscous media in rotating packed bed(RPB) was developed based on penetration theory and mass conservation.Before establishing the model,some mass transfer experiments of thin film were conducted in a designed diffusion cell including vacuum and feeding system. In this study,acetone was used as the volatile organic compound(VOC) and syrup as the highly viscous media.The thickness of thin film was changed by using different liquid distributor.It was found that bubbling played an important role in the devolatilization.The correlation of diffusion coefficient of acetone in highly viscous dilute solution was proposed.The relative error between predicted and experimental data was within the range of ± 30% for diffusion coefficient of acetone in syrup.A comparison of experimental data of RPB with model indicated that the relative error was within ± 30% for efficiency of acetone removal.展开更多
Danckwert’s method was used to determine the specific interfacial area, a, and the individual mass transfer coefficient, kL, during absorption of CO2 in a bubble column with an anionic surfactant in the carbonate-bi...Danckwert’s method was used to determine the specific interfacial area, a, and the individual mass transfer coefficient, kL, during absorption of CO2 in a bubble column with an anionic surfactant in the carbonate-bicarbonate buffer solution and NaAsO2 as catalyst, the presence of which decreases the specific interfacial area and the individual mass transfer coefficient. The specific interfacial area and the individual mass transfer coefficient increase with increasing su- perficial gas velocity. The specific interfacial area decreases whereas the individual mass transfer coefficient increases with increasing temperature. The results of experiments were used to determine the dependence of a, kL, and kLa on the surface tension, the temperature of the absorption phase, and the superficial velocity of the gas. The calculated results from the correlation were found to be within 10% deviation from the actual experimental results.展开更多
In this work,a novel rotating microchannel extractor(RME)is designed and further used for the extraction of chromium(Ⅲ)from water.Unexpectedly,the micro-extraction had the same effect as carrying out 2.9-stage cross-...In this work,a novel rotating microchannel extractor(RME)is designed and further used for the extraction of chromium(Ⅲ)from water.Unexpectedly,the micro-extraction had the same effect as carrying out 2.9-stage cross-flow extractions.Various factors,including the gas intake methods,gas intake quantity(Qg),distance between inner rotor and outer wall(D),rotational inner rotor speed(R)and volumetric flow rate(Qa,Qo),were selected to investigate their effect on the extraction efficiency(η)thoroughly.The relation map ofηwith Weaand We(o-g)for RME provides a comprehension for the gas–liquid–liquid extraction process in this RME system.展开更多
The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the ge...The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the geometry, the operating parameters and the physical properties of the liquid phase on gas hold-up and mass transfer coefficient were measuered. Compared with other types of gas-liquid reactor, D-JLR shows higher mass transfer coefficient and lower energy dissipation rate, the optimum diameter ratio was found to be about 0.42-0.6. A model for gas hold-up in D-JLR with Newtonian and non-Newtonian fluids has been developed on the basis of the equation of motion and the concept of average mixing length. The prediction of gas hold-up with the model agreed with the experimental results of this work.展开更多
基金the projects ENE2010-15585 and CTQ2012-31639the FPI postgraduate research grant(BES-2011-046279)
文摘Recovery of carbon monoxide from flue gases by selective absorption of carbon monoxide in an imidazolium chlorocuprate(l) ionic liquid is considered in this work as an alternative to the use of molecular volatile solvents such as aromatic hydrocarbons. The present work evaluates the CO mass transfer rates from the gas phase to the ionic liquid solutions in the absence of chemical reaction. To that end, carbon dioxide was employed as an inert model gas and absorption experiments were performed to assess the influence of different process variables in a batch reactor with fiat gas-liquid interface. The experimental mass transfer coefficients showed significant var- iation with temperature, (3.4-10.9) × 10^-7 m·s^-1 between 293 and 313 K; stirring speed, (10.2- 33.1)× 10^-7 m.s 1 between 100 and 300 r·min^-1; and concentration of copper(1), (6.6-10.2) × 10^-7 m·s^-1 between 0.25 and 2 mol· L^- 1. In addition, the mass transfer coefficients were eventually found to follow a poten- tial proportionality of the type kL ∝μ^-0.5 and the dimensionless correlation that makes the estimation of the mass transfer coefficients possible in the studied range of process variables was obtained: Sh=10^-2.64 Re^1.07 , Sc^0.75,These results constitute the first step in the kinetic analysis of the reaction between CO and imidazolium chlorocuprate(I) ionic liquid that determines the design of the separation units.
文摘This paper describes the application of ultrasound waves on hydrodynamics and mass transfer characteristics in the gas–liquid flow in a T-shape microreactor with a diameter of 800 μm. A 1.7 MHz piezoelectric transducer(PZT) was employed to induce the vibration in this microreactor. Liquid side volumetric mass transfer coefficients were measured by physical and chemical methods of CO_2 absorption into water and Na OH solution. The approach of absorption of CO_2 into a 1 mol·L^(-1) Na OH solution was used for analysis of interfacial areas. With the help of a photography system, the fluid flow patterns inside the microreactor were analyzed. The effects of superficial liquid velocity, initial concentration of Na OH, superficial CO_2 gas velocity and length of microreactor on the mass transfer rate were investigated. The comparison between sonicated and plain microreactors(microreactor with and without ultrasound) shows that the ultrasound wave irradiation has a significant effect on kLa and interfacial area at various operational conditions. For the microreactor length of 12 cm, ultrasound waves improved kLa and interfacial area about 21% and 22%, respectively. From this study, it can be concluded that ultrasound wave irradiation in microreactor has a great effect on the mass transfer rate. This study suggests a new enhancement technique to establish high interfacial area and kLa in microreactors.
基金the authors appreciate the vice-chancellor of research and technology of the University of Isfahan for supporting this work under Grant No.911401707。
文摘The hydrodynamics and mass transfer characteristics of a lab-scale jet bubbling reactor(JBR)including the gas holdup,volumetric mass transfer coefficient and specific interfacial area were assessed experimentally investigating the influence of temperature,pH and superficial gas velocity.The reactor diameter and height were 11 and 30 cm,respectively.It was equipped with a single sparger,operating at atmospheric pressure,20 and 40℃,and two pH values of 3 and 6.The height of the liquid was 23 cm,while the superficial gas velocity changed within 0.010-0.040 m·s^(-1)range.Experiments were conducted with pure oxygen as the gas phase and saturated lime solution as the liquid phase.The liquid-side volumetric mass transfer coefficient was determined under unsteady-state oxygen absorption in a saturated lime solution.The gas holdup was calculated based on the liquid height change,while the specific interfacial area was obtained by a physical method based on the bubble size distribution(BSD)in different superficial gas velocities.The results indicated that at the same temperature but different pH,the gas holdup variation was negligible,while the liquid-side volumetric mass transfer coefficient at the pH value of 6 was higher than that at the pH=3.At a constant pH but different temperatures,the gas holdup and the liquid-side volumetric mass transfer coefficients at 40℃were higher than that of the same at 20℃.A reasonable and appropriate estimation of the liquid-side volumetric mass transfer coefficient(kla)in a pilot-scale JBR was provided which can be applied to the design and scale-up of JBRs.
文摘A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is consisted of span80 [ sorbitian monooleate], paraffin oil, D2EHPA [ 2-( 2-ethylhexyl- phosphonic acid)], kerosene as well as HCl solution. The extraction under various conditions such as the span80 concentrations, the flow rate of aqueous, the extraction time and HCl concentrations in receiving phase were studied. Results show that the lower the flow rates of aqueous are, the higher the extraction percentage and enrichment-fold are, and the extraction percentage increases with the increasing of HCl concentrations. When the initial Nd^3+ concentration in feed is maintained at 1000 mg· L^-1 and the emulsion is recycled with 70 times by a counter-flow,
基金supported by National Key Research and Development Program(No.2016YFD0501402-04)National Natural Science Foundation of China(Nos.21776179,21621004)the Program for Changjiang Scholars and Innovative Research Team in University(No.IRT_15R46)。
文摘A pore-array intensified tube-in-tube microchannel(PA-TMC),which is characterized by high throughput and low pressure drop,was developed as a gas–liquid contactor.The sulfite oxidation method was used to determine the oxygen efficiency(φ)and volumetric mass transfer coefficient(k_(L)a)of PA-TMC,and the mass transfer amount per unit energy(ε)was calculated by using the pressure drop.The effects of structural and operating parameters were investigated systematically,and the twophase flow behavior was monitored by using a charge-coupled device imaging system.The results indicated that the gas absorption efficiency and mass transfer performance of the PA-TMC were improved with increasing pore number,flow rate,and number of helical coil turns and decreasing pore size,row number,annular size,annular length,and surface tension.Theφ,εand k La of PA-TMC could reach 31.3%,1.73×10^(-4) mol/J,and 7.0 s-1,respectively.The Sherwood number was correlated with the investigated parameters to guide the design of PA-TMC in gas absorption and mass transfer processes.
基金Supported by the National Natural Science Foundation of China(20821004 20990221) the National High Technology Research and Development Program of China(2006AA030202)+1 种基金 the Program for New Century Excellent Talents in University of China(NCET-07-0053) the National Basic Research Program of China(2009CB219903)
文摘A mass transfer model for devolatilization process of highly viscous media in rotating packed bed(RPB) was developed based on penetration theory and mass conservation.Before establishing the model,some mass transfer experiments of thin film were conducted in a designed diffusion cell including vacuum and feeding system. In this study,acetone was used as the volatile organic compound(VOC) and syrup as the highly viscous media.The thickness of thin film was changed by using different liquid distributor.It was found that bubbling played an important role in the devolatilization.The correlation of diffusion coefficient of acetone in highly viscous dilute solution was proposed.The relative error between predicted and experimental data was within the range of ± 30% for diffusion coefficient of acetone in syrup.A comparison of experimental data of RPB with model indicated that the relative error was within ± 30% for efficiency of acetone removal.
文摘Danckwert’s method was used to determine the specific interfacial area, a, and the individual mass transfer coefficient, kL, during absorption of CO2 in a bubble column with an anionic surfactant in the carbonate-bicarbonate buffer solution and NaAsO2 as catalyst, the presence of which decreases the specific interfacial area and the individual mass transfer coefficient. The specific interfacial area and the individual mass transfer coefficient increase with increasing su- perficial gas velocity. The specific interfacial area decreases whereas the individual mass transfer coefficient increases with increasing temperature. The results of experiments were used to determine the dependence of a, kL, and kLa on the surface tension, the temperature of the absorption phase, and the superficial velocity of the gas. The calculated results from the correlation were found to be within 10% deviation from the actual experimental results.
基金financial support from the National Natural Science Foundation of China(21776181)Sichuan University innovation spark project(2018SCUH0012)+1 种基金Chinese National Key Research and Development Plan(2018YFC1900203-03)Special Project of Building World-class Universities(2030704401004)。
文摘In this work,a novel rotating microchannel extractor(RME)is designed and further used for the extraction of chromium(Ⅲ)from water.Unexpectedly,the micro-extraction had the same effect as carrying out 2.9-stage cross-flow extractions.Various factors,including the gas intake methods,gas intake quantity(Qg),distance between inner rotor and outer wall(D),rotational inner rotor speed(R)and volumetric flow rate(Qa,Qo),were selected to investigate their effect on the extraction efficiency(η)thoroughly.The relation map ofηwith Weaand We(o-g)for RME provides a comprehension for the gas–liquid–liquid extraction process in this RME system.
文摘The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the geometry, the operating parameters and the physical properties of the liquid phase on gas hold-up and mass transfer coefficient were measuered. Compared with other types of gas-liquid reactor, D-JLR shows higher mass transfer coefficient and lower energy dissipation rate, the optimum diameter ratio was found to be about 0.42-0.6. A model for gas hold-up in D-JLR with Newtonian and non-Newtonian fluids has been developed on the basis of the equation of motion and the concept of average mixing length. The prediction of gas hold-up with the model agreed with the experimental results of this work.