期刊文献+
共找到137篇文章
< 1 2 7 >
每页显示 20 50 100
Recovery of carbon monoxide from flue gases by reactive absorption in ionic liquid imidazolium chlorocuprate(I): Mass transfer coefficients 被引量:2
1
作者 Gabriel Zarca Inmaculada Ortiz Ane Urtiaga 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2015年第5期769-774,共6页
Recovery of carbon monoxide from flue gases by selective absorption of carbon monoxide in an imidazolium chlorocuprate(l) ionic liquid is considered in this work as an alternative to the use of molecular volatile so... Recovery of carbon monoxide from flue gases by selective absorption of carbon monoxide in an imidazolium chlorocuprate(l) ionic liquid is considered in this work as an alternative to the use of molecular volatile solvents such as aromatic hydrocarbons. The present work evaluates the CO mass transfer rates from the gas phase to the ionic liquid solutions in the absence of chemical reaction. To that end, carbon dioxide was employed as an inert model gas and absorption experiments were performed to assess the influence of different process variables in a batch reactor with fiat gas-liquid interface. The experimental mass transfer coefficients showed significant var- iation with temperature, (3.4-10.9) × 10^-7 m·s^-1 between 293 and 313 K; stirring speed, (10.2- 33.1)× 10^-7 m.s 1 between 100 and 300 r·min^-1; and concentration of copper(1), (6.6-10.2) × 10^-7 m·s^-1 between 0.25 and 2 mol· L^- 1. In addition, the mass transfer coefficients were eventually found to follow a poten- tial proportionality of the type kL ∝μ^-0.5 and the dimensionless correlation that makes the estimation of the mass transfer coefficients possible in the studied range of process variables was obtained: Sh=10^-2.64 Re^1.07 , Sc^0.75,These results constitute the first step in the kinetic analysis of the reaction between CO and imidazolium chlorocuprate(I) ionic liquid that determines the design of the separation units. 展开更多
关键词 Carbon monoxide Ionic liquid Copper(I)Reactive absorption mass transfer kinetics mass transfer coefficient Carbon dioxide
下载PDF
Gas–liquid flow mass transfer in a T-shape microreactor stimulated with 1.7 MHz ultrasound waves 被引量:4
2
作者 Mona Akbari Masoud Rahimi Mahboubeh Faryadi 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第9期1143-1152,共10页
This paper describes the application of ultrasound waves on hydrodynamics and mass transfer characteristics in the gas–liquid flow in a T-shape microreactor with a diameter of 800 μm. A 1.7 MHz piezoelectric transdu... This paper describes the application of ultrasound waves on hydrodynamics and mass transfer characteristics in the gas–liquid flow in a T-shape microreactor with a diameter of 800 μm. A 1.7 MHz piezoelectric transducer(PZT) was employed to induce the vibration in this microreactor. Liquid side volumetric mass transfer coefficients were measured by physical and chemical methods of CO_2 absorption into water and Na OH solution. The approach of absorption of CO_2 into a 1 mol·L^(-1) Na OH solution was used for analysis of interfacial areas. With the help of a photography system, the fluid flow patterns inside the microreactor were analyzed. The effects of superficial liquid velocity, initial concentration of Na OH, superficial CO_2 gas velocity and length of microreactor on the mass transfer rate were investigated. The comparison between sonicated and plain microreactors(microreactor with and without ultrasound) shows that the ultrasound wave irradiation has a significant effect on kLa and interfacial area at various operational conditions. For the microreactor length of 12 cm, ultrasound waves improved kLa and interfacial area about 21% and 22%, respectively. From this study, it can be concluded that ultrasound wave irradiation in microreactor has a great effect on the mass transfer rate. This study suggests a new enhancement technique to establish high interfacial area and kLa in microreactors. 展开更多
关键词 Ultrasound waves MICROREACTOR gasliquid flow mass transfer ABSORPTION
下载PDF
Experimental determination of gas holdup and volumetric mass transfer coefficient in a jet bubbling reactor 被引量:3
3
作者 Mostafa Abbasian-arani Mohammad Sadegh Hatamipour Amir Rahimi 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2021年第6期61-67,共7页
The hydrodynamics and mass transfer characteristics of a lab-scale jet bubbling reactor(JBR)including the gas holdup,volumetric mass transfer coefficient and specific interfacial area were assessed experimentally inve... The hydrodynamics and mass transfer characteristics of a lab-scale jet bubbling reactor(JBR)including the gas holdup,volumetric mass transfer coefficient and specific interfacial area were assessed experimentally investigating the influence of temperature,pH and superficial gas velocity.The reactor diameter and height were 11 and 30 cm,respectively.It was equipped with a single sparger,operating at atmospheric pressure,20 and 40℃,and two pH values of 3 and 6.The height of the liquid was 23 cm,while the superficial gas velocity changed within 0.010-0.040 m·s^(-1)range.Experiments were conducted with pure oxygen as the gas phase and saturated lime solution as the liquid phase.The liquid-side volumetric mass transfer coefficient was determined under unsteady-state oxygen absorption in a saturated lime solution.The gas holdup was calculated based on the liquid height change,while the specific interfacial area was obtained by a physical method based on the bubble size distribution(BSD)in different superficial gas velocities.The results indicated that at the same temperature but different pH,the gas holdup variation was negligible,while the liquid-side volumetric mass transfer coefficient at the pH value of 6 was higher than that at the pH=3.At a constant pH but different temperatures,the gas holdup and the liquid-side volumetric mass transfer coefficients at 40℃were higher than that of the same at 20℃.A reasonable and appropriate estimation of the liquid-side volumetric mass transfer coefficient(kla)in a pilot-scale JBR was provided which can be applied to the design and scale-up of JBRs. 展开更多
关键词 Jet bubbling reactor liquid-side volumetric mass transfer coefficient gas holdup Specific interfacial area Experimental analysis
下载PDF
Extraction of Neodymium by Emulsion-Liquid-Membrane within Hollow-Fiber-contactor and Its Mass Transfer Properties
4
作者 Gong Fuzhong Luo Yan +1 位作者 Ma Peihua Zhang Limei 《Journal of Rare Earths》 SCIE EI CAS CSCD 2006年第3期280-280,共1页
A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is co... A non-dispersive extraction technique, using an emulsion liquid membrane within a hollow-fiber-contactor for the extraction and enrichment of Nd^3+ from the dilute feed aqueous, was applied. The emulsion system is consisted of span80 [ sorbitian monooleate], paraffin oil, D2EHPA [ 2-( 2-ethylhexyl- phosphonic acid)], kerosene as well as HCl solution. The extraction under various conditions such as the span80 concentrations, the flow rate of aqueous, the extraction time and HCl concentrations in receiving phase were studied. Results show that the lower the flow rates of aqueous are, the higher the extraction percentage and enrichment-fold are, and the extraction percentage increases with the increasing of HCl concentrations. When the initial Nd^3+ concentration in feed is maintained at 1000 mg· L^-1 and the emulsion is recycled with 70 times by a counter-flow, 展开更多
关键词 emulsion liquid membrane hollow-fiber-membrane non-dispersive extraction mass-transfer coefficient NEODYMIUM rare earths
下载PDF
Gas Absorption and Mass Transfer in a Pore-Array Intensified Tube-in-Tube Microchannel
5
作者 Fengshun Xia Wenpeng Li +5 位作者 Junheng Guo You Han Minqing Zhang Baoguo Wang Wei Li Jinli Zhang 《Transactions of Tianjin University》 2021年第5期409-421,共13页
A pore-array intensified tube-in-tube microchannel(PA-TMC),which is characterized by high throughput and low pressure drop,was developed as a gas–liquid contactor.The sulfite oxidation method was used to determine th... A pore-array intensified tube-in-tube microchannel(PA-TMC),which is characterized by high throughput and low pressure drop,was developed as a gas–liquid contactor.The sulfite oxidation method was used to determine the oxygen efficiency(φ)and volumetric mass transfer coefficient(k_(L)a)of PA-TMC,and the mass transfer amount per unit energy(ε)was calculated by using the pressure drop.The effects of structural and operating parameters were investigated systematically,and the twophase flow behavior was monitored by using a charge-coupled device imaging system.The results indicated that the gas absorption efficiency and mass transfer performance of the PA-TMC were improved with increasing pore number,flow rate,and number of helical coil turns and decreasing pore size,row number,annular size,annular length,and surface tension.Theφ,εand k La of PA-TMC could reach 31.3%,1.73×10^(-4) mol/J,and 7.0 s-1,respectively.The Sherwood number was correlated with the investigated parameters to guide the design of PA-TMC in gas absorption and mass transfer processes. 展开更多
关键词 Pore-array intensified tube-in-tube microchannel(PA-TMCR) gasliquid mass transfer Sulfite oxidation method
下载PDF
A Mass Transfer Model for Devolatilization of Highly Viscous Media in Rotating Packed Bed 被引量:13
6
作者 李沃源 毋伟 +3 位作者 邹海魁 初广文 邵磊 陈建峰 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第2期194-201,共8页
A mass transfer model for devolatilization process of highly viscous media in rotating packed bed(RPB) was developed based on penetration theory and mass conservation.Before establishing the model,some mass transfer e... A mass transfer model for devolatilization process of highly viscous media in rotating packed bed(RPB) was developed based on penetration theory and mass conservation.Before establishing the model,some mass transfer experiments of thin film were conducted in a designed diffusion cell including vacuum and feeding system. In this study,acetone was used as the volatile organic compound(VOC) and syrup as the highly viscous media.The thickness of thin film was changed by using different liquid distributor.It was found that bubbling played an important role in the devolatilization.The correlation of diffusion coefficient of acetone in highly viscous dilute solution was proposed.The relative error between predicted and experimental data was within the range of ± 30% for diffusion coefficient of acetone in syrup.A comparison of experimental data of RPB with model indicated that the relative error was within ± 30% for efficiency of acetone removal. 展开更多
关键词 mass transfer highly viscous liquid volatile organic compound diffusion coefficient rotating packed bed
下载PDF
Modeling of mass transfer characteristics of bubble column reactor with surfactant present 被引量:10
7
作者 赵伟荣 史惠祥 汪大翚 《Journal of Zhejiang University Science》 EI CSCD 2004年第6期714-720,共7页
Danckwert’s method was used to determine the specific interfacial area, a, and the individual mass transfer coefficient, kL, during absorption of CO2 in a bubble column with an anionic surfactant in the carbonate-bi... Danckwert’s method was used to determine the specific interfacial area, a, and the individual mass transfer coefficient, kL, during absorption of CO2 in a bubble column with an anionic surfactant in the carbonate-bicarbonate buffer solution and NaAsO2 as catalyst, the presence of which decreases the specific interfacial area and the individual mass transfer coefficient. The specific interfacial area and the individual mass transfer coefficient increase with increasing su- perficial gas velocity. The specific interfacial area decreases whereas the individual mass transfer coefficient increases with increasing temperature. The results of experiments were used to determine the dependence of a, kL, and kLa on the surface tension, the temperature of the absorption phase, and the superficial velocity of the gas. The calculated results from the correlation were found to be within 10% deviation from the actual experimental results. 展开更多
关键词 mass transfer coefficient SURFACTANT Bubble column reactor gas absorption
下载PDF
Gas-liquid-liquid extraction in a novel rotating microchannel extractor 被引量:2
8
作者 Rui Ma Chunxin Fan +3 位作者 Yubin Wang Jianhong Luo Jun Li Sridhar Komarneni 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2020年第10期2523-2532,共10页
In this work,a novel rotating microchannel extractor(RME)is designed and further used for the extraction of chromium(Ⅲ)from water.Unexpectedly,the micro-extraction had the same effect as carrying out 2.9-stage cross-... In this work,a novel rotating microchannel extractor(RME)is designed and further used for the extraction of chromium(Ⅲ)from water.Unexpectedly,the micro-extraction had the same effect as carrying out 2.9-stage cross-flow extractions.Various factors,including the gas intake methods,gas intake quantity(Qg),distance between inner rotor and outer wall(D),rotational inner rotor speed(R)and volumetric flow rate(Qa,Qo),were selected to investigate their effect on the extraction efficiency(η)thoroughly.The relation map ofηwith Weaand We(o-g)for RME provides a comprehension for the gas–liquid–liquid extraction process in this RME system. 展开更多
关键词 MICROEXTRACTION gasliquidliquid Rotating microchannel extractor mass transfer Extraction efficiency
下载PDF
STUDY OF DOWNFLOW LIQUID JET LOOP REACTOR
9
作者 尚龙安 范代娣 +1 位作者 李宝璋 杨文选 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1996年第3期61-71,共11页
The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the ge... The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the geometry, the operating parameters and the physical properties of the liquid phase on gas hold-up and mass transfer coefficient were measuered. Compared with other types of gas-liquid reactor, D-JLR shows higher mass transfer coefficient and lower energy dissipation rate, the optimum diameter ratio was found to be about 0.42-0.6. A model for gas hold-up in D-JLR with Newtonian and non-Newtonian fluids has been developed on the basis of the equation of motion and the concept of average mixing length. The prediction of gas hold-up with the model agreed with the experimental results of this work. 展开更多
关键词 LOOP REACTOR downflow liquid JET gas HOLD-UP mass transfer model
下载PDF
多孔板鼓泡塔流动与传质特性数值模拟
10
作者 王娟 李秀明 +5 位作者 邵炜涛 丁续 霍莹 付连超 白云宇 李迪 《化工学报》 EI CSCD 北大核心 2024年第3期801-814,F0002,共15页
采用Euler-Euler双流体模型对安装不同数量的水平多孔板的鼓泡塔内气液两相流动及传质特性进行数值模拟研究,并探究了不同表观气速条件对鼓泡塔内气含率、气泡直径分布和气液传质系数的影响。结果表明,不同数量的多孔板和不同位置的多... 采用Euler-Euler双流体模型对安装不同数量的水平多孔板的鼓泡塔内气液两相流动及传质特性进行数值模拟研究,并探究了不同表观气速条件对鼓泡塔内气含率、气泡直径分布和气液传质系数的影响。结果表明,不同数量的多孔板和不同位置的多孔板都会影响气含率的分布;随着多孔板的数目增加,鼓泡塔液相上方区域的气含率增加,但影响区域有限;安装多孔板后,鼓泡塔内径向位置的平均气含率变化明显,出现“M”形状的分布。不同表观气速下,未安装多孔板的鼓泡塔内直径为1~2mm的微小气泡占比超过30%;安装多孔板后,微小气泡占比明显增加;气液传质系数在中心区域(径向无量纲为-0.5~0.5)较为平缓,波动不大。最后将模拟计算得到的气液体积传质系数与Akita的关联式计算值进行比较,本文计算结果略高。 展开更多
关键词 鼓泡塔 CFD-PBM模型 气泡直径 气含率 气液体积传质系数
下载PDF
微乳液膜法萃取钕 被引量:21
11
作者 龚福忠 李成海 +2 位作者 马培华 唐艳霞 刘经伟 《化工学报》 EI CAS CSCD 北大核心 2003年第11期1569-1574,共6页
进行了微乳液膜法萃取Nd3 +的研究 ,考察了不同盐酸浓度时微乳液的溶水量及其对Nd3 +的萃取率、内相富集浓度的影响 ,同时还考察了温度、料液浓度、缓冲剂对萃取Nd3 +的影响 .结果表明 ,随着盐酸浓度增大 ,微乳液溶水量增加 ;内相Nd3 +... 进行了微乳液膜法萃取Nd3 +的研究 ,考察了不同盐酸浓度时微乳液的溶水量及其对Nd3 +的萃取率、内相富集浓度的影响 ,同时还考察了温度、料液浓度、缓冲剂对萃取Nd3 +的影响 .结果表明 ,随着盐酸浓度增大 ,微乳液溶水量增加 ;内相Nd3 +富集倍数最高为 2 4 3倍 ,料液Nd3 +浓度相同时 ,内相Nd3 +富集浓度和富集倍数随溶水量增加而减小 ,萃取率则变化不大 ,一般在 70 %~ 80 %范围 ,于料液中加入缓冲剂对Nd3 +的萃取率有很大影响 .根据微乳液膜渗透速率方程计算了传质系数 .通过在微乳液和料液之间加载一层亲水性微孔滤膜 ,避免了微乳液与料液直接接触所产生的乳化 。 展开更多
关键词 微乳液膜 微孔滤膜 萃取 传质系数
下载PDF
溶液除湿冷却系统的再生性能实验研究 被引量:20
12
作者 殷勇高 张小松 +1 位作者 权硕 李秀伟 《工程热物理学报》 EI CAS CSCD 北大核心 2005年第6期915-917,共3页
基于以氯化锂水溶液为除湿剂的除湿冷却系统(DECS),对其溶液的再生过程进行实验研究。研究了热源温度、溶液浓度对填料塔式再生系统再生性能的影响情况,实验表明溶液浓度在20%时,空气含湿量最大增量为37.1 g/kg干空气。计算出几种工况... 基于以氯化锂水溶液为除湿剂的除湿冷却系统(DECS),对其溶液的再生过程进行实验研究。研究了热源温度、溶液浓度对填料塔式再生系统再生性能的影响情况,实验表明溶液浓度在20%时,空气含湿量最大增量为37.1 g/kg干空气。计算出几种工况下的传质系数,最大的传质系数为0.0072 kg/(m2·s),并得出系统有关参数对传质系数的影响,为此类再生器的性能模拟与设计提供关键性的数据。 展开更多
关键词 再生 实验研究 溶液除湿 传质系数
下载PDF
气液传质理论研究进展 被引量:24
13
作者 马友光 白鹏 余国琮 《化学工程》 CAS CSCD 北大核心 1996年第6期7-11,共5页
文内对气液传质的理论研究进行了评述。
关键词 气液传质 传质系数 传质模型
下载PDF
金属板波纹规整填料在CO_2吸收塔中的传质性能 被引量:6
14
作者 杨伟 彭勇 +2 位作者 密建国 汤志刚 陈健 《化学工程》 CAS CSCD 北大核心 2013年第10期13-16,共4页
开发高效规整填料,有利于降低CO2捕集过程的能耗和成本。文章在直径200 mm的填料塔中,使用氢氧化钠水溶液吸收空气中微量CO2的方法研究了金属板波纹规整填料的传质性能,测定了具有不同几何参数的规整填料的有效传质面积。实验结果表明:... 开发高效规整填料,有利于降低CO2捕集过程的能耗和成本。文章在直径200 mm的填料塔中,使用氢氧化钠水溶液吸收空气中微量CO2的方法研究了金属板波纹规整填料的传质性能,测定了具有不同几何参数的规整填料的有效传质面积。实验结果表明:随着气液相流量的增加,有效传质面积逐渐增大,且气相流量的影响相对较大。当气液流量达到一定值时,有效传质面积会超过填料的比表面积。而填料几何参数对有效传质面积也有较大的影响。当波纹倾角α=30°,波纹齿顶角β=75°时,有效传质面积较大。而且α对有效传质面积的影响较β大。在同时考虑气液相流速的影响的基础上,文章提出了新的有效传质面积的关联式,计算值与实验值吻合较好。 展开更多
关键词 CO2吸收 规整填料 液相传质系数 有效传质面积
下载PDF
三相下喷式环流反应器的传质性能 被引量:11
15
作者 李永祥 程振民 +1 位作者 蒋正兴 袁渭康 《高校化学工程学报》 EI CAS CSCD 北大核心 1997年第4期366-371,共6页
在三相非牛顿型流体体系中,对下喷式环流反应器传质特性进行了实验研究。讨论了表观气速、能量耗散速率、导流筒直径与反应器直径比、喷嘴直径、导流筒下端距反应器底部的距离、固体装填量、羧甲基纤维素钠(CMC)溶液浓度及其流变... 在三相非牛顿型流体体系中,对下喷式环流反应器传质特性进行了实验研究。讨论了表观气速、能量耗散速率、导流筒直径与反应器直径比、喷嘴直径、导流筒下端距反应器底部的距离、固体装填量、羧甲基纤维素钠(CMC)溶液浓度及其流变特性对它的影响。实验结果表明,容积传质系数随表观气速和能量耗散速率的增加有所增加,在实验条件下,发现最优的导流筒直径与反应器直径比在0.4~0.45这一范围、固体装填量大约为3%(体积百分比)、导流筒下端距反应器底部的距离为0.08m左右。同时提出了容积传质系数的经验关联式。 展开更多
关键词 下喷式 环流反应器 传质系数 非牛顿流体 三相
下载PDF
第二液相对气液二相体系传质的影响 被引量:4
16
作者 李文秀 于三三 +1 位作者 史正学 毕颖 《化学工程》 EI CAS CSCD 北大核心 2007年第9期1-3,8,共4页
以CO2气体-K2CO3/KHCO3水溶液吸收过程为研究体系,用酸解法测量气体被吸收的速率,通过对比试验考察了加入第2液相(有机相)对体系传质速率的影响。经过试验研究证明,第2液相的加入对气液传质过程的影响程度与加入的物质有关,在试验条件... 以CO2气体-K2CO3/KHCO3水溶液吸收过程为研究体系,用酸解法测量气体被吸收的速率,通过对比试验考察了加入第2液相(有机相)对体系传质速率的影响。经过试验研究证明,第2液相的加入对气液传质过程的影响程度与加入的物质有关,在试验条件下甲苯对体系强化作用高于异辛醇和庚烷对体系的强化作用。当第2液相加入量较小时,随加入量的增加,其对气液传质过程的促进作用增强,但当第2液相加入量较大时,这种作用则不明显。同时第2液相对传质作用的影响与流动场有关,增加流动场的搅动有助于强化气液传质作用。 展开更多
关键词 气液传质 过程强化 传质系数 第2液相
下载PDF
微量醇及电解质强化气液传质的研究 被引量:5
17
作者 臧晓红 王军 +1 位作者 刘延来 沈自求 《化学反应工程与工艺》 EI CAS CSCD 北大核心 2005年第3期221-226,233,共7页
在气升式内环流反应器中考察了微量醇类物质(乙醇、叔丁醇、季戊四醇)及电解质(CaCl_2)对氧的液相体积传质系数和气含率的影响。结果表明,向空气-水体系中添加微量醇类物质可以明显改善气液传质性能,同时醇类物质强化气-液传质存在一极... 在气升式内环流反应器中考察了微量醇类物质(乙醇、叔丁醇、季戊四醇)及电解质(CaCl_2)对氧的液相体积传质系数和气含率的影响。结果表明,向空气-水体系中添加微量醇类物质可以明显改善气液传质性能,同时醇类物质强化气-液传质存在一极限浓度,超过此浓度后,氧的液相体积传质系数略有降低;当表观气速增加时,去离子水体系和含醇体系的气含率都增加,但醇体系的气含率明显高于去离子水体系。此外,添加电解质 CaCl_2也会使氧的液相体积传质系数有所提高,并从离子强度的角度对其抑制气泡聚并的机理进行了分析。 展开更多
关键词 气液传质 气升式环流反应器 液相体积传质系数 醇类物质 电解质 气含率 氧气 气泡聚并
下载PDF
甲醇、水蒸气在液体石蜡中的溶解度和体积传质系数的研究 被引量:5
18
作者 宋怀俊 张海涛 +1 位作者 应卫勇 房鼎业 《石油化工》 EI CAS CSCD 北大核心 2005年第6期551-555,共5页
在机械搅拌高压釜中,测定了433.15~533.15K、0.110~0.960 MPa之间甲醇和水蒸气在液体石蜡中的溶解度和体积传质系数.实验结果表明,甲醇和水蒸气的溶解度均随压力的升高而增加,随温度的升高而减小,溶解度与压力的关系曲线为通过原点的... 在机械搅拌高压釜中,测定了433.15~533.15K、0.110~0.960 MPa之间甲醇和水蒸气在液体石蜡中的溶解度和体积传质系数.实验结果表明,甲醇和水蒸气的溶解度均随压力的升高而增加,随温度的升高而减小,溶解度与压力的关系曲线为通过原点的直线,符合亨利定律.回归了甲醇和水蒸气的亨利系数与温度的关联式,甲醇和水蒸气的溶解度的计算值与实验值的相对误差小于6.00%.甲醇和水蒸气的体积传质系数随温度和压力的升高而增加. 展开更多
关键词 甲醇 水蒸气 液体石蜡 溶解度 体积传质系数
下载PDF
鼓泡床反应器内流动与传质行为的研究进展 被引量:13
19
作者 何广湘 杨索和 靳海波 《化学工业与工程》 CAS 2007年第1期75-80,共6页
总结了有关浆态鼓泡床反应器内流动、混合用气液传质特性的研究成果,详细地介绍了鼓泡床反应器内气含率、液速、液体轴向扩散系数、传质系数的测量方法,阐述了鼓泡床反应器性能的主要影响因素,如系统压力、温度、气体表观气速、液体性... 总结了有关浆态鼓泡床反应器内流动、混合用气液传质特性的研究成果,详细地介绍了鼓泡床反应器内气含率、液速、液体轴向扩散系数、传质系数的测量方法,阐述了鼓泡床反应器性能的主要影响因素,如系统压力、温度、气体表观气速、液体性质及固含率等对流动、液相混合和传质特性的影响,并对鼓泡床反应器的应用前景进行了详述。 展开更多
关键词 鼓泡床反应器 气含率 液速 轴向扩散系数 传质系数
下载PDF
气升式环流反应器的研究进展 被引量:11
20
作者 何广湘 杨索和 靳海波 《化学工业与工程》 CAS 2008年第1期65-71,共7页
环流反应器在工业上正得到越来越广泛的应用,对其进行深入研究对于此类反应器的设计与放大具有重要意义。对环流反应器的流动、混合及传质特性参数随表观气速、液相物性、系统压力和反应器尺寸等操作条件的变化关系进行了综述。介绍了... 环流反应器在工业上正得到越来越广泛的应用,对其进行深入研究对于此类反应器的设计与放大具有重要意义。对环流反应器的流动、混合及传质特性参数随表观气速、液相物性、系统压力和反应器尺寸等操作条件的变化关系进行了综述。介绍了各特性参数的测量方法,并指出了这些方法的优缺点及可能存在的误差。对环流反应器的流动、混合及传质特性的数学模型进行了评述,并在此基础上对环流反应器研究的发展前景进行了展望。 展开更多
关键词 气升式环流反应器 气含率 循环液速 扩散系数 体积传质系数
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部