期刊文献+
共找到73篇文章
< 1 2 4 >
每页显示 20 50 100
An Investigation of Battery Energy Storage Aided Wind-Coal Integrated Energy System 被引量:1
1
作者 Enhui Sun Jiahao Shi +3 位作者 Lei Zhang Hongfu Ji Qian Zhang Yongyi Li 《Energy Engineering》 EI 2023年第7期1583-1602,共20页
This paper studies the feasibility of a supply-side wind-coal integrated energy system.Based on grid-side data,the load regulation model of coal-fired power and the wind-coal integrated energy system model are establi... This paper studies the feasibility of a supply-side wind-coal integrated energy system.Based on grid-side data,the load regulation model of coal-fired power and the wind-coal integrated energy system model are established.According to the simulation results,the reasons why the wind-coal combined power supply is difficult to meet the grid-side demand are revealedthrough scenario analysis.Basedon thewind-coal combinedoperation,a wind-coalstorage integrated energy system was proposed by adding lithium-iron phosphate battery energy storage system(LIPBESS)to adjust the load of the system.According to the four load adjustment scenarios of grid-side instructions of the wind-coal system,the difficulty of load adjustment in each scenario is analyzed.Based on the priority degree of LIPBESS charge/discharge in four scenarios at different time periods,the operation mode of two charges and two discharges per day was developed.Based on the independent operation level of coal-fired power,after the addition of LIPBESS(5.5 MWh),the average qualified rate of multi-power operation in March and June reached the level of independent operation of coal-fired power,while the average qualified rate of the remaining months was only 5.4%different from that of independent operation of coal-fired power.Compared with the wind storage mode,the energy storage capacity and investment cost of wind-coal-storage integrated energy system are reduced by 54.2%and 53.7%,respectively. 展开更多
关键词 Wind power lithium-iron phosphate battery energy storage system coal-fired power integrated energy system
下载PDF
A distributed VSG control method for a battery energy storage system with a cascaded H-bridge in a grid-connected mode 被引量:4
2
作者 Yichi Cai Donglian Qi 《Global Energy Interconnection》 EI CAS CSCD 2022年第4期343-352,共10页
With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role ... With the high penetration of renewable energy,new challenges,such as power fluctuation suppression and inertial support capability,have arisen in the power sector.Battery energy storage systems play an essential role in renewable energy integration.In this paper,a distributed virtual synchronous generator(VSG)control method for a battery energy storage system(BESS)with a cascaded H-bridge converter in a grid-connected mode is proposed.The VSG is developed without communication dependence,and state-of-charge(SOC)balancing control is achieved using the distributed average algorithm.Owing to the low varying speed of SOC,the bandwidth of the distributed communication networks is extremely slow,which decreases the cost.Therefore,the proposed method can simultaneously provide inertial support and accurate SOC balancing.The stability is also proved using root locus analysis.Finally,simulations under different conditions are carried out to verify the effectiveness of the proposed method. 展开更多
关键词 VSG Cascaded H-bridge converters battery energy storage system Renewable energy integration
下载PDF
Battery Energy Storage to Strengthen the Wind Generator in Integrated Power System 被引量:2
3
作者 Sharad W. Mohod Mohan V. Aware 《Journal of Electronic Science and Technology》 CAS 2011年第1期23-30,共8页
The wind energy generation,utilization and its grid penetration in electrical grid are increasing world-wide.The wind generated power is always fluctuating due to its time varying nature and causing stability problem.... The wind energy generation,utilization and its grid penetration in electrical grid are increasing world-wide.The wind generated power is always fluctuating due to its time varying nature and causing stability problem.This weak interconnection of wind generating source in the electrical network affects the power quality and reliability.The localized energy storages shall compensate the fluctuating power and support to strengthen the wind generator in the power system.In this paper,it is proposed to control the voltage source inverter (VSI) in current control mode with energy storage,that is,batteries across the dc bus.The generated wind power can be extracted under varying wind speed and stored in the batteries.This energy storage maintains the stiff voltage across the dc bus of the voltage source inverter.The proposed scheme enhances the stability and reliability of the power system and maintains unity power factor.It can also be operated in stand-alone mode in the power system.The power exchange across the wind generation and the load under dynamic situation is feasible while maintaining the power quality norms at the common point of coupling.It strengthens the weak grid in the power system.This control strategy is evaluated on the test system under dynamic condition by using simulation.The results are verified by comparing the performance of controllers. 展开更多
关键词 battery energy storage power quality wind energy generating system.
下载PDF
Multifunction Battery Energy Storage System for Distribution Networks 被引量:1
4
作者 Omar H.Abdalla Gamal Abdel-Salam Azza A.A.Mostafa 《Energy Engineering》 EI 2022年第2期569-589,共21页
Battery Energy Storage System(BESS)is one of the potential solutions to increase energy system flexibility,as BESS is well suited to solve many challenges in transmission and distribution networks.Examples of distribu... Battery Energy Storage System(BESS)is one of the potential solutions to increase energy system flexibility,as BESS is well suited to solve many challenges in transmission and distribution networks.Examples of distribution network’s challenges,which affect network performance,are:(i)Load disconnection or technical constraints violation,which may happen during reconfiguration after fault,(ii)Unpredictable power generation change due to Photovoltaic(PV)penetration,(iii)Undesirable PV reverse power,and(iv)Low Load Factor(LF)which may affect electricity price.In this paper,the BESS is used to support distribution networks in reconfiguration after a fault,increasing Photovoltaic(PV)penetration,cutting peak load,and loading valley filling.The paper presents a methodology for BESS optimal locations and sizing considering technical constraints during reconfiguration after a fault and PV power generation changes.For determining themaximumpower generation change due to PV,actual power registration of connected PV plants in South Cairo Electricity Distribution Company(SCEDC)was considered for a year.In addition,the paper provides a procedure for distribution network operator to employ the proposed BESS to perform multi functions such as:the ability to absorb PV power surplus,cut peak load and fill load valley for improving network’s performances.The methodology is applied to a modified IEEE 37-node and a real network part consisting of 158 nodes in SCEDC zone.The simulation studies are performed using the DIgSILENT PowerFactory software andDPL programming language.The Mixed Integer Linear Programming optimization technique(MILP)in MATLAB is employed to choose the best locations and sizing of BESS. 展开更多
关键词 battery energy storage system photovoltaic penetration peak load reduction valley filling MILP optimization
下载PDF
Typical Application Scenarios and Economic Benefit Evaluation Methods of Battery Energy Storage System
5
作者 Ming Zeng Haibin Cao +4 位作者 Ting Pan Pinduan Hu Shi Tian Lijun Zhong Zhi Ling 《Energy Engineering》 EI 2022年第4期1569-1586,共18页
Energy storage system is an important means to improve the flexibility and safety of traditional power system,but it has the problem of high cost and unclear value recovery path.In this paper,the typical application s... Energy storage system is an important means to improve the flexibility and safety of traditional power system,but it has the problem of high cost and unclear value recovery path.In this paper,the typical application scenarios of energy storage system are summarized and analyzed from the perspectives of user side,power grid side and power generation side.Based on the typical application scenarios,the economic benefit assessment framework of energy storage system including value,time and efficiency indicators is proposed.Typical battery energy storage projects are selected for economic benefit calculation according to different scenarios,and key factors are selected for sensitivity analysis.Finally,the key factors affecting economic benefit of the energy storage system are analyzed. 展开更多
关键词 battery energy storage system application scenarios economic benefit evaluation sensitivity analysis
下载PDF
Improved Energy Management Strategy for Prosumer Buildings with Renewable Energy Sources and Battery Energy Storage Systems
6
作者 Pavitra Sharma Krishna Kumar Saini +1 位作者 Hitesh Datt Mathur Puneet Mishra 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期381-392,共12页
The concept of utilizing microgrids(MGs)to convert buildings into prosumers is gaining massive popularity because of its economic and environmental benefits.These pro-sumer buildings consist of renewable energy source... The concept of utilizing microgrids(MGs)to convert buildings into prosumers is gaining massive popularity because of its economic and environmental benefits.These pro-sumer buildings consist of renewable energy sources and usually install battery energy storage systems(BESSs)to deal with the uncertain nature of renewable energy sources.However,because of the high capital investment of BESS and the limitation of available energy,there is a need for an effective energy management strategy for prosumer buildings that maximizes the profit of building owner and increases the operating life span of BESS.In this regard,this paper proposes an improved energy management strategy(IEMS)for the prosumer building to minimize the operating cost of MG and degradation factor of BESS.Moreover,to estimate the practical operating life span of BESS,this paper utilizes a non-linear battery degradation model.In addition,a flexible load shifting(FLS)scheme is also developed and integrated into the proposed strategy to further improve its performance.The proposed strategy is tested for the real-time annual data of a grid-tied solar photovoltaic(PV)and BESS-powered AC-DC hybrid MG installed at a commercial building.Moreover,the scenario reduction technique is used to handle the uncertainty associated with generation and load demand.To validate the performance of the proposed strategy,the results of IEMS are compared with the well-established energy management strategies.The simulation results verify that the proposed strategy substantially increases the profit of the building owner and operating life span of BESS.Moreover,FLS enhances the performance of IEMS by further improving the financial profit of MG owner and the life span of BESS,thus making the operation of prosumer building more economical and efficient. 展开更多
关键词 Prosumer building battery energy storage system(BESS) battery degradation factor demand response energy management MICROGRID solar photovoltaic(PV)system
原文传递
Virtual Transmission Solution Based on Battery Energy Storage Systems to Boost Transmission Capacity
7
作者 Matías Agüero Jaime Peralta +5 位作者 Eugenio Quintana Victor Velar Anton Stepanov Hossein Ashourian Jean Mahseredjian Roberto Cárdenas 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期466-474,共9页
The increasing penetration of variable renewable energy(VRE)generation along with the decommissioning of conventional power plants in Chile,has raised several operational challenges in the Chilean National Power Grid(... The increasing penetration of variable renewable energy(VRE)generation along with the decommissioning of conventional power plants in Chile,has raised several operational challenges in the Chilean National Power Grid(NPG),including transmission congestion and VRE curtailment.To mitigate these limitations,an innovative virtual transmission solution based on battery energy storage systems(BESSs),known as grid booster(GB),has been proposed to increase the capacity of the main 500 kV corridor of the NPG.This paper analyzes the dynamic performance of the GB using a wide-area electromagnetic transient(EMT)model of the NPG.The GB project,composed of two 500 MVA BESS units at each extreme of the 500 kV corridor,allows increasing the transmission capacity for 15 min during N-1 contingencies,overcoming transmission limitations under normal operation conditions while maintaining system stability during faults.The dynamic behavior of the GB is also analyzed to control power flow as well as voltage stability.The results show that the GB is an effective solution to allow greater penetration of VRE generation while maintaining system stability in the NPG. 展开更多
关键词 battery energy storage system(BESS) grid booster transient stability voltage stability electromagnetic transient(EMT)
原文传递
Multi-Scale Fusion Model Based on Gated Recurrent Unit for Enhancing Prediction Accuracy of State-of-Charge in Battery Energy Storage Systems
8
作者 Hao Liu Fengwei Liang +2 位作者 Tianyu Hu Jichao Hong Huimin Ma 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期405-414,共10页
Accurate prediction of the state-of-charge(SOC)of battery energy storage system(BESS)is critical for its safety and lifespan in electric vehicles.To overcome the imbalance of existing methods between multi-scale featu... Accurate prediction of the state-of-charge(SOC)of battery energy storage system(BESS)is critical for its safety and lifespan in electric vehicles.To overcome the imbalance of existing methods between multi-scale feature fusion and global feature extraction,this paper introduces a novel multi-scale fusion(MSF)model based on gated recurrent unit(GRU),which is specifically designed for complex multi-step SOC prediction in practical BESSs.Pearson correlation analysis is first employed to identify SOC-related parameters.These parameters are then input into a multi-layer GRU for point-wise feature extraction.Concurrently,the parameters undergo patching before entering a dual-stage multi-layer GRU,thus enabling the model to capture nuanced information across varying time intervals.Ultimately,by means of adaptive weight fusion and a fully connected network,multi-step SOC predictions are rendered.Following extensive validation over multiple days,it is illustrated that the proposed model achieves an absolute error of less than 1.5%in real-time SOC prediction. 展开更多
关键词 Electric vehicle battery energy storage system(BESS) state-of-charge(SOC)prediction gated recurrent unit(GRU) multi-scale fusion(MSF).
原文传递
An Analytical Method for Delineating Feasible Region for PV Integration Capacities in Net-zero Distribution Systems Considering Battery Energy Storage System Flexibility
9
作者 Shida Zhang Shaoyun Ge +2 位作者 Hong Liu Guocheng Hou Chengshan Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第2期475-487,共13页
To provide guidance for photovoltaic(PV)system integration in net-zero distribution systems(DSs),this paper proposes an analytical method for delineating the feasible region for PV integration capacities(PVICs),where ... To provide guidance for photovoltaic(PV)system integration in net-zero distribution systems(DSs),this paper proposes an analytical method for delineating the feasible region for PV integration capacities(PVICs),where the impact of battery energy storage system(BESS)flexibility is considered.First,we introduce distributionally robust chance constraints on network security and energy/carbon net-zero requirements,which form the upper and lower bounds of the feasible region.Then,the formulation and solution of the feasible region is proposed.The resulting analytical expression is a set of linear inequalities,illustrating that the feasible region is a polyhedron in a high-dimensional space.A procedure is designed to verify and adjust the feasible region,ensuring that it satisfies network loss constraints under alternating current(AC)power flow.Case studies on the 4-bus system,the IEEE 33-bus system,and the IEEE 123-bus system verify the effectiveness of the proposed method.It is demonstrated that the proposed method fully captures the spatio-temporal coupling relationship among PVs,loads,and BESSs,while also quantifying the impact of this relationship on the boundaries of the feasible region. 展开更多
关键词 Net-zero distribution system photovoltaic(PV)integration capacity feasible region battery energy storage system(BESS).
原文传递
Deep reinforcement learning for online scheduling of photovoltaic systems with battery energy storage systems
10
作者 Yaze Li Jingxian Wu Yanjun Pan 《Intelligent and Converged Networks》 EI 2024年第1期28-41,共14页
A new online scheduling algorithm is proposed for photovoltaic(PV)systems with battery-assisted energy storage systems(BESS).The stochastic nature of renewable energy sources necessitates the employment of BESS to bal... A new online scheduling algorithm is proposed for photovoltaic(PV)systems with battery-assisted energy storage systems(BESS).The stochastic nature of renewable energy sources necessitates the employment of BESS to balance energy supplies and demands under uncertain weather conditions.The proposed online scheduling algorithm aims at minimizing the overall energy cost by performing actions such as load shifting and peak shaving through carefully scheduled BESS charging/discharging activities.The scheduling algorithm is developed by using deep deterministic policy gradient(DDPG),a deep reinforcement learning(DRL)algorithm that can deal with continuous state and action spaces.One of the main contributions of this work is a new DDPG reward function,which is designed based on the unique behaviors of energy systems.The new reward function can guide the scheduler to learn the appropriate behaviors of load shifting and peak shaving through a balanced process of exploration and exploitation.The new scheduling algorithm is tested through case studies using real world data,and the results indicate that it outperforms existing algorithms such as Deep Q-learning.The online algorithm can efficiently learn the behaviors of optimum non-casual off-line algorithms. 展开更多
关键词 photovoltaic(PV) battery energy storage system(BESS) Markov decision process(MDP) deep deterministic policy gradient(DDPG)
原文传递
Battery energy storage-based system damping controller for alleviating sub-synchronous oscillations in a DFIG-based wind power plant 被引量:2
11
作者 Neevatika Verma Narendra Kumar Rajeev Kumar 《Protection and Control of Modern Power Systems》 SCIE EI 2023年第2期260-277,共18页
This paper presents the issue of the Sub-synchronous resonance(SSR)phenomenon in a series compensated DFIG-based wind power plant and its alleviation using a Battery Energy Storage-based Damping Controller(BESSDCL).A ... This paper presents the issue of the Sub-synchronous resonance(SSR)phenomenon in a series compensated DFIG-based wind power plant and its alleviation using a Battery Energy Storage-based Damping Controller(BESSDCL).A supplementary damping signal is developed considering the angular speed deviation and is incorporated into the BESS control system.Wide-area Measurement System data is used to determine the angular speed deviation.A lin-earized system model is developed to perform eigenvalue analysis,and to detect and examine unstable SSR modes.The variation of wind speed and three-phase fault are also taken into consideration to validate the robustness of the controller.To further verify the efficacy of the proposed damping controller,time-domain simulations are performed using MATLAB/Simulink.The application of the proposed BESSDCL stabilizes all the unstable system modes effectively at wind speeds of 7 m/s,9 m/s,and 11 m/s,and at 40%,50%,and 60%series compensation levels,as well three-phase fault conditions. 展开更多
关键词 battery energy storage system Damping controller Doubly-fed induction generator(DFIG) SERIES
原文传递
Distributed Step-by-step Finite-time Consensus Design for Battery Energy Storage Devices with Droop Control 被引量:1
12
作者 Yalin Zhang Yunzhong Song Shumin Fei 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第5期1893-1904,共12页
As all generators are distributed in different areas among large scale power systems,the cooperative manipulation of the multi-generator system cannot operate well without consideration of the distance information of ... As all generators are distributed in different areas among large scale power systems,the cooperative manipulation of the multi-generator system cannot operate well without consideration of the distance information of the generators.A distributed step-by-step finite-time consensus scheme for the heterogeneous battery energy storage system(BESS)is proposed in this paper,where the coordinated consensus can come into reality within a limited time,which is appealing for the electrical engineering community.To be concrete,at first,all BESSs are classified into several clusters according to their locations,and in each cluster,there is an active leader in charge of information receiving from outside.Then,in order to coordinate the multi BESSs,five inputs,which are function oriented,were used to achieve energy level balancing,active/reactive power sharing,and the consensus of voltage and frequency of the multi BESSs.Furthermore,the frequency and voltage restoration to the nominal values of the main grid were made possible by the introduction of a virtual leader,which is actually an external leader.Compared with the centralized methods,this control scheme is entirely distributed,and each BESS only utilizes the information of its own and its neighbors.In addition,this control is robust to the load perturbation and the plug-and-play of the communication topology.Finally,some simulation experiments are executed on the modified IEEE 57-bus system to verify the suggested scheme. 展开更多
关键词 battery energy storage system distributed cooperative control finite-time consensus multi-agent system step-by-step consensus
原文传递
A Two-Layer Fuzzy Control Strategy for the Participation of Energy Storage Battery Systems in Grid Frequency Regulation 被引量:1
13
作者 Wei Chen Na Sun +2 位作者 Zhicheng Ma Wenfei Liu Haiying Dong 《Energy Engineering》 EI 2023年第6期1445-1464,共20页
To address the frequency fluctuation problem caused by the power dynamic imbalance between the power system and the loadwhen a large number of newenergy sources are connected to the grid,a two-layer fuzzy control stra... To address the frequency fluctuation problem caused by the power dynamic imbalance between the power system and the loadwhen a large number of newenergy sources are connected to the grid,a two-layer fuzzy control strategy is proposed for the participation of the energy storage battery system in FM.Firstly,considering the coordination of FM units responding to automatic power generation control commands,a comprehensive allocation strategy of two signals under automatic power generation control commands is proposed to give full play to the advantages of two FM signals while enabling better coordination of two FM units responding to FM commands;secondly,based on the grid FM demand and battery FM capability,a double-layer fuzzy control strategy is proposed for FM units responding to automatic power generation control commands in a coordinated manner under dual-signal allocation mode to precisely allocate the power output depth of FM units,which can control the fluctuation of frequency deviation within a smaller range at a faster speed while maintaining the battery charge state;finally,the proposed Finally,the proposed control strategy is simulated and verified inMatlab/Simulink.The results show that the proposed control strategy can control the frequency deviation within a smaller range in a shorter time,better stabilize the fluctuation of the battery charge level,and improve the utilization of the FM unit. 展开更多
关键词 battery energy storage secondary FM signal distribution mode charge state two-layer fuzzy control
下载PDF
Provision of Ramp-rate Limitation as Ancillary Service from Distribution to Transmission System:Definitions and Methodologies for Control and Sizing of Central Battery Energy Storage System
14
作者 Spyros I.Gkavanoudis Kyriaki-Nefeli D.Malamaki +4 位作者 Eleftherios O.Kontis Aditya Shekhar Umer Mushtaq Sagar Bandi Venu Charis S.Demoulias 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第5期1507-1518,共12页
The variability of the output power of distributed renewable energy sources(DRESs)that originate from the fastchanging climatic conditions can negatively affect the grid stability.Therefore,grid operators have incorpo... The variability of the output power of distributed renewable energy sources(DRESs)that originate from the fastchanging climatic conditions can negatively affect the grid stability.Therefore,grid operators have incorporated ramp-rate limitations(RRLs)for the injected DRES power in the grid codes.As the DRES penetration levels increase,the mitigation of high-power ramps is no longer considered as a system support function but rather an ancillary service(AS).Energy storage systems(ESSs)coordinated by RR control algorithms are often applied to mitigate these power fluctuations.However,no unified definition of active power ramps,which is essential to treat the RRL as AS,currently exists.This paper assesses the various definitions for ramp-rate RR and proposes RRL method control for a central battery ESS(BESS)in distribution systems(DSs).The ultimate objective is to restrain high-power ramps at the distribution transformer level so that RRL can be traded as AS to the upstream transmission system(TS).The proposed control is based on the direct control of theΔP/Δt,which means that the control parameters are directly correlated with the RR requirements included in the grid codes.In addition,a novel method for restoring the state of charge(So C)within a specific range following a high ramp-up/down event is proposed.Finally,a parametric method for estimating the sizing of central BESSs(BESS sizing for short)is developed.The BESS sizing is determined by considering the RR requirements,the DRES units,and the load mix of the examined DS.The BESS sizing is directly related to the constant RR achieved using the proposed control.Finally,the proposed methodologies are validated through simulations in MATLAB/Simulink and laboratory tests in a commercially available BESS. 展开更多
关键词 battery energy storage system distributed renewable energy resource SIZING distribution system transmission system ramp-rate limitation state of charge
原文传递
Model Predictive Control Strategy for Residential Battery Energy Storage System in Volatile Electricity Market with Uncertain Daily Cycling Load
15
作者 Dejan P.Jovanović Gerard F.Ledwich Geoffrey R.Walker 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第2期534-543,共10页
This paper presents a control strategy for residential battery energy storage systems,which is aware of volatile electricity markets and uncertain daily cycling loads.The economic benefits of energy trading for prosum... This paper presents a control strategy for residential battery energy storage systems,which is aware of volatile electricity markets and uncertain daily cycling loads.The economic benefits of energy trading for prosumers are achieved through a novel modification of a conventional model predictive control(MPC).The proposed control strategy guarantees an optimal global solution for the applied control action.A new cost function is introduced to model the effects of volatility on customer benefits more effectively.Specifically,the newly presented cost function models a probabilistic relation between the power exchanged with the grid,the net load,and the electricity market.The probabilistic calculation of the cost function shows the dependence on the mathematical expectation of market price and net load.Computational techniques for calculating this value are presented.The proposed strategy differs from the stochastic and robust MPC in that the cost is calculated across the market price and net load variations rather than across model constraints and parameter variations. 展开更多
关键词 Optimal control model predictive control(MPC) energy market nonlinear constrained optimization revenue for battery energy storage system Gaussian mixture model autoregressive integrated moving average model
原文传递
Contingency Reserve Evaluation for Fast Frequency Response of Multiple Battery Energy Storage Systems in a Large-scale Power Grid
16
作者 Indira Alcaide-Godinez Feifei Bai +1 位作者 Tapan Kumar Saha Rizah Memisevic 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第3期873-883,共11页
Recently,the fast frequency response(FFR)service by large-scale battery energy storage systems(BESSs)has been successfully proved to arrest the frequency excursion during an unexpected power outage.However,adequate fr... Recently,the fast frequency response(FFR)service by large-scale battery energy storage systems(BESSs)has been successfully proved to arrest the frequency excursion during an unexpected power outage.However,adequate frequency response relies on proper evaluation of the contingency reserve of BESSs.The BESS FFR reserve is commonly managed under fixed contracts,ignoring various response characteristics of different BESSs and their coexisting interactions.This paper proposes a new methodology based on dynamic grid response and various BESS response characteristics to optimise the FFR reserves and prevent the frequency from breaching the under-frequency load shedding(UFLS)thresholds.The superiority of the proposed method is demonstrated to manage three large-scale BESSs operating simultaneously in an Australian power grid under high renewable penetration scenarios.Further,the proposed method can identify remaining battery power and energy reserve to be safely utilised for other grid services(e.g.,energy arbitrage).The results can provide valuable insights for integrating FFR into conventional ancillary services and techno-effective management of multiple BESSs. 展开更多
关键词 Fast frequency response(FFR) fast frequency contingency reserve multiple large-scale battery energy storage system(BESS) synthetic inertia requirement under-frequency load shedding(UFLS)
原文传递
Optimal control and management of large-scale battery energy storage system to mitigate fluctuation and intermittence of renewable generations 被引量:42
17
作者 Xiangjun LI Liangzhong YAO Dong HUI 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第4期593-603,共11页
Battery energy storage system(BESS)is one of the effective technologies to deal with power fluctuation and intermittence resulting from grid integration of large renewable generations.In this paper,the system configur... Battery energy storage system(BESS)is one of the effective technologies to deal with power fluctuation and intermittence resulting from grid integration of large renewable generations.In this paper,the system configuration of a China’s national renewable generation demonstration project combining a large-scale BESS with wind farm and photovoltaic(PV)power station,all coupled to a power transmission system,is introduced,and the key technologies including optimal control and management as well as operational status of this BESS are presented.Additionally,the technical benefits of such a large-scale BESS in dealing with power fluctuation and intermittence issues resulting from grid connection of large-scale renewable generation,and for improvement of operation characteristics of transmission grid,are discussed with relevant case studies. 展开更多
关键词 battery energy storage systems Renewable generations Power fluctuation battery energy management system Power control
原文传递
Optimal planning of battery energy storage considering reliability benefit and operation strategy in active distribution system 被引量:26
18
作者 Wenxia LIU Shuya NIU Huiting XU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第2期177-186,共10页
In this paper, a cost-benefit analysis based optimal planning model of battery energy storage system(BESS) in active distribution system(ADS) is established considering a new BESS operation strategy. Reliability impro... In this paper, a cost-benefit analysis based optimal planning model of battery energy storage system(BESS) in active distribution system(ADS) is established considering a new BESS operation strategy. Reliability improvement benefit of BESS is considered and a numerical calculation method based on expectation is proposed for simple and convenient calculation of system reliability improvement with BESS in planning phase. Decision variables include both configuration variables and operation strategy control variables. In order to prevent the interaction between two types of variables and enhance global search ability, intelligent single particle optimizer(ISPO) is adopted to optimize this model. Case studies on a modified IEEE benchmark system verified the performance of the proposed operation strategy and optimal planning model of BESS. 展开更多
关键词 battery energy storage system Cost-benefit analysis Reliability improvement benefit Operation strategy Intelligent single particle optimizer
原文传递
Energy Management and Operational Control Methods for Grid Battery Energy Storage Systems 被引量:20
19
作者 Xiangjun Li Shangxing Wang 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第5期1026-1040,共15页
Energy storage is one of the key means for improving the flexibility,economy and security of power system.It is also important in promoting new energy consumption and the energy Internet.Therefore,energy storage is ex... Energy storage is one of the key means for improving the flexibility,economy and security of power system.It is also important in promoting new energy consumption and the energy Internet.Therefore,energy storage is expected to support distributed power and the micro-grid,promote open sharing and flexible trading of energy production and consumption,and realize multi-functional coordination.In recent years,with the rapid development of the battery energy storage industry,its technology has shown the characteristics and trends for large-scale integration and distributed applications with multi-objective collaboration.As a grid-level application,energy management systems(EMS)of a battery energy storage system(BESS)were deployed in real time at utility control centers as an important component of power grid management.Based on the analysis of the development status of a BESS,this paper introduced application scenarios,such as reduction of power output fluctuations,agreement to the output plan at the renewable energy generation side,power grid frequency adjustment,power flow optimization at the power transmission side,and a distributed and niohile energy storage system at the power distribution side.The studies and application status of a BESS in recent years were reviewed.The energy management,operation control methods,and application scenes of large-scale BESSs were also examined in the study. 展开更多
关键词 battery energy storage system(BESS) energy management systems(EMS) multi-objective collaborative control new energy integration power grid ancillary service.
原文传递
Application and Modeling of Battery Energy Storage in Power Systems 被引量:10
20
作者 Xiaokang Xu Martin Bishop +1 位作者 Donna G.Oikarinen Chen Hao 《CSEE Journal of Power and Energy Systems》 SCIE 2016年第3期82-90,共9页
This paper presents engineering experiences from battery energy storage system(BESS)projects that require design and implementation of specialized power conversion systems(a fast-response,automatic power converter and... This paper presents engineering experiences from battery energy storage system(BESS)projects that require design and implementation of specialized power conversion systems(a fast-response,automatic power converter and controller).These projects concern areas of generation,transmission,and distribution of electric energy,as well as end-energy user benefits,such as grid frequency regulation,renewable energy smoothing and leveling,energy dispatching and arbitrage,power quality and reliability improvements for connected customers,islanding operations,and smart microgrid applications.In general,a grid level BESS project sends an interconnect request to utility power grids in the project development stage.Simulation models of equipment are then sent for a system impact study(e.g.,power flow and/or stability analysis),based on utility grid code requirements.The system study then determines the connection’s technical feasibility and impact of the project on the power grid.In this paper,a set of new BESS models is presented that are configured and parameterized for use in system impact studies as well as transmission planning studies.The models,which have been recently approved and released by the U.S.Western Electricity Coordinating Council(WECC),represent the steady state and dynamic performance of the BESS in several software platforms for power system studies based on operating project performance experience.Model benchmarking results as well as a real system case study are also included in the paper to show that the parameterized and tuned models respond correctly and as expected when system operating conditions change following contingency events.Finally,this paper provides useful guidelines in the use of new models to represent a BESS for power system analysis. 展开更多
关键词 battery energy storage CONTINGENCY frequency regulation power flow analysis power quality power reliability renewable energy smart microgrid stability analysis state of charge system impact studies transmission planning
原文传递
上一页 1 2 4 下一页 到第
使用帮助 返回顶部