Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case ...Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case of seismic forces. Numerous retrofitting works using fibre reinforced polymer (FRP) composites are being undertaken worldwide. This work aims to investigate the effectiveness of strengthening beam-column joints using natural and artificial fibres. In this study, basalt (natural fibres) as monolithic composite (BFRP) and as hybrid composite along with glass (artificial fibres) were used for strengthening of beam-column joints. Totally six specimens were prepared and tested under monotonic loading. Specimen details used were: two control specimen, two specimens for monolithic wrapping and remaining two specimens for hybrid wrapping. The test results were compared with control and rehabilitated specimens. The performance of the treated joints was studied using the following parameters: initial and ultimate cracking loads, energy absorption, deflection ductility and stiffness at ultimate. From the test results, it was found that the hybrid combination of Basalt and Glass FRPs were found to be more effective in the treatment of beam-column joints. The strong column weak beam concept was achieved by failure in beam portion which helped in preventing the catastrophic failure of the entire structure.展开更多
Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the p...Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the plastic hinges (PHs) on such main structural components as columns, beams and walls, the complex behavior of shear failure at beam-column joints (BCJs) during major earthquakes is commonly neglected. This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures. Based on the specifications of FEMA-356, a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established, allowing a sophisticated PA to be performed. To verify the validity of this method, the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements. By considering shear failure at BCJs, the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames, including seismic capacity and the progressive failure sequence of joints, in a precise and effective manner.展开更多
A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is locate...A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints.展开更多
This paper studies the seismic performance of FRP-strengthened RC interior non-seismically detailed beam-wide columns and beam-wall joints after limited seismic damage.Four eccentric and concentric beam-wide column jo...This paper studies the seismic performance of FRP-strengthened RC interior non-seismically detailed beam-wide columns and beam-wall joints after limited seismic damage.Four eccentric and concentric beam-wide column joints and two beam-wall joints,initially damaged in a previous study,were repaired and tested under constant axial loads(0.1fc′Ag and 0.35fc′Ag) and lateral cyclic loading.The rapid repair technique developed,aimed to restore the original strength and to provide minimum drift capacity.The repair schemes were characterized by the use of:(a) epoxy injections and polymer modified cementitious mortar to seal the cracks and replace spalled concrete;and(b) glass(GFRP) and carbon(CFRP) sheets to enhance the joint performance.The FRP sheets were effectively prevented against possible debonding through the use of fiber anchors.Comparison between responses of specimens before and after repair clearly indicated reasonable restoration in strength,drift capacity,stiffness and cumulative energy dissipation capacity.All specimens failed with delamination of FRP sheets at beam-column joint interfaces.The rapid repair technique developed in this study is recommended for mass upgrading or repair of earthquake damaged beam-column joints.展开更多
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ...A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.展开更多
The behavior of Beam-Column Joints in moment resisting frame structures are susceptible to damage caused by seismic effects due to poor performance of the joint.A good number of researches were carried out to understa...The behavior of Beam-Column Joints in moment resisting frame structures are susceptible to damage caused by seismic effects due to poor performance of the joint.A good number of researches were carried out to understand the complex mechanism of RC joints which are considered in seismic design code practices presently adopted.The traditional construction detailing of transverse reinforcement have shown serious joint failure. This paper introduces a new design philosophy involving the use of additional diagonal bars within the joint particularly suitable for low to medium seismic effects in earthquake zones throughout the world.In lieu to this study,ten(10) full-scale interior beam-column specimens were constructed with various additional reinforcement details and configurations as will be discussed in the later.The experiment provided adequate results to proof the idea of additional bars as suitable approach in reinforced concrete structures where earthquake is eminent.While compared with overall cracking observation during the test,the specimen with additional bars (diagonal and straight) had shown few cracks on the column than the ones without.Furthermore,concrete confinement is certainly an important design method as recommended by certain international codes.展开更多
This paper analyses the seismic performance of exterior beam-column joints strengthened with unconventional reinforcement detailing. The beam-column joint specimens were tested with reverse cyclic loading applied at t...This paper analyses the seismic performance of exterior beam-column joints strengthened with unconventional reinforcement detailing. The beam-column joint specimens were tested with reverse cyclic loading applied at the beam end. The samples were divided into two groups based on the joint reinforcement detailing. The first group (Group A) of three non-ductility specimens had joint detailing in accordance with the construction code of practice in India IS456-2000, and the second group (Group B) of three ductility specimens had joint reinforcement detailed as per IS13920-1993, with similar axial load cases as the first group. The experimental studies are proven with the analytical studies carried out by finite element models using ANSYS. The results show that the hysteresis simulation is satisfactory for both un-strengthened and ferrocement strengthened specimens. Furthermore, when ferrocement strengthening is employed, the strengthened beam-column joints exhibit better structural performance than the un-strengthened specimens of about 31.56% and 38.98 for DD-T1 and DD-T2 respectively. The analytical shear strength predictions were in line with the test results reported in the literature, thus adding confidence to the validity of the proposed models.展开更多
文摘Beam-Column joints are critical zones in reinforced concrete structures which are most vulnerable to earthquake forces. Hence strengthening beam-column joint is vital to save the structure and its inhabitants in case of seismic forces. Numerous retrofitting works using fibre reinforced polymer (FRP) composites are being undertaken worldwide. This work aims to investigate the effectiveness of strengthening beam-column joints using natural and artificial fibres. In this study, basalt (natural fibres) as monolithic composite (BFRP) and as hybrid composite along with glass (artificial fibres) were used for strengthening of beam-column joints. Totally six specimens were prepared and tested under monotonic loading. Specimen details used were: two control specimen, two specimens for monolithic wrapping and remaining two specimens for hybrid wrapping. The test results were compared with control and rehabilitated specimens. The performance of the treated joints was studied using the following parameters: initial and ultimate cracking loads, energy absorption, deflection ductility and stiffness at ultimate. From the test results, it was found that the hybrid combination of Basalt and Glass FRPs were found to be more effective in the treatment of beam-column joints. The strong column weak beam concept was achieved by failure in beam portion which helped in preventing the catastrophic failure of the entire structure.
文摘Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the plastic hinges (PHs) on such main structural components as columns, beams and walls, the complex behavior of shear failure at beam-column joints (BCJs) during major earthquakes is commonly neglected. This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures. Based on the specifications of FEMA-356, a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established, allowing a sophisticated PA to be performed. To verify the validity of this method, the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements. By considering shear failure at BCJs, the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames, including seismic capacity and the progressive failure sequence of joints, in a precise and effective manner.
文摘A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints.
文摘This paper studies the seismic performance of FRP-strengthened RC interior non-seismically detailed beam-wide columns and beam-wall joints after limited seismic damage.Four eccentric and concentric beam-wide column joints and two beam-wall joints,initially damaged in a previous study,were repaired and tested under constant axial loads(0.1fc′Ag and 0.35fc′Ag) and lateral cyclic loading.The rapid repair technique developed,aimed to restore the original strength and to provide minimum drift capacity.The repair schemes were characterized by the use of:(a) epoxy injections and polymer modified cementitious mortar to seal the cracks and replace spalled concrete;and(b) glass(GFRP) and carbon(CFRP) sheets to enhance the joint performance.The FRP sheets were effectively prevented against possible debonding through the use of fiber anchors.Comparison between responses of specimens before and after repair clearly indicated reasonable restoration in strength,drift capacity,stiffness and cumulative energy dissipation capacity.All specimens failed with delamination of FRP sheets at beam-column joint interfaces.The rapid repair technique developed in this study is recommended for mass upgrading or repair of earthquake damaged beam-column joints.
基金Sponsored by the National Natural Science Foundation of China (Grant No.50478027)
文摘A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.
基金Research Institute of Structural Engineering and Seismic Disaster Prevention,Tongji University
文摘The behavior of Beam-Column Joints in moment resisting frame structures are susceptible to damage caused by seismic effects due to poor performance of the joint.A good number of researches were carried out to understand the complex mechanism of RC joints which are considered in seismic design code practices presently adopted.The traditional construction detailing of transverse reinforcement have shown serious joint failure. This paper introduces a new design philosophy involving the use of additional diagonal bars within the joint particularly suitable for low to medium seismic effects in earthquake zones throughout the world.In lieu to this study,ten(10) full-scale interior beam-column specimens were constructed with various additional reinforcement details and configurations as will be discussed in the later.The experiment provided adequate results to proof the idea of additional bars as suitable approach in reinforced concrete structures where earthquake is eminent.While compared with overall cracking observation during the test,the specimen with additional bars (diagonal and straight) had shown few cracks on the column than the ones without.Furthermore,concrete confinement is certainly an important design method as recommended by certain international codes.
文摘This paper analyses the seismic performance of exterior beam-column joints strengthened with unconventional reinforcement detailing. The beam-column joint specimens were tested with reverse cyclic loading applied at the beam end. The samples were divided into two groups based on the joint reinforcement detailing. The first group (Group A) of three non-ductility specimens had joint detailing in accordance with the construction code of practice in India IS456-2000, and the second group (Group B) of three ductility specimens had joint reinforcement detailed as per IS13920-1993, with similar axial load cases as the first group. The experimental studies are proven with the analytical studies carried out by finite element models using ANSYS. The results show that the hysteresis simulation is satisfactory for both un-strengthened and ferrocement strengthened specimens. Furthermore, when ferrocement strengthening is employed, the strengthened beam-column joints exhibit better structural performance than the un-strengthened specimens of about 31.56% and 38.98 for DD-T1 and DD-T2 respectively. The analytical shear strength predictions were in line with the test results reported in the literature, thus adding confidence to the validity of the proposed models.