The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or p...The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.展开更多
In this paper, the comparison of absorbed dose measurement performed with an extrapolation chamber and a Fanner chamber in high energy electron beam is described. The experiments performed in the course of this work s...In this paper, the comparison of absorbed dose measurement performed with an extrapolation chamber and a Fanner chamber in high energy electron beam is described. The experiments performed in the course of this work show that the Xinjiang extrapolation chamber is suitable for calibration of high energy electron beams produced from medical linear accelerators.展开更多
Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The...Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The present work introduces design and investigation of a new ring-shaped monitor chamber with a PMMA body, graphite-coated PMMA windows (0.5 mm thick), a special graphite-foil central electrode (0.1 mm thick, 0.7 g/cm3 dense) that creating two sensitive volumes and a central hole for crossing the radiation beam with less attenuation. The results of performance tests conducted at the Nuclear Science and Technology Research Institute, AEOI in Karaj- Iran proved the high short and long-term stability, the very low leakage current, the low directional dependence and very high ion collection efficiency through the special design of the collecting electrode. Moreover, the FLUKA Monte Carlo simulations certified the negligible effect of central electrode on this new ring-shaped monitor chamber. According to the results of the performance tests, the new monitor chamber can be used as a standard dosimeter in order to monitor X-ray beam in primary standard dosimetry laboratories.展开更多
The clinical trials of tumor therapy using heavy ions beam 12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy 12C beam in active pencil...The clinical trials of tumor therapy using heavy ions beam 12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy 12C beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy 12C beam in active pencil beam scanning mode.展开更多
文摘The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen.
文摘In this paper, the comparison of absorbed dose measurement performed with an extrapolation chamber and a Fanner chamber in high energy electron beam is described. The experiments performed in the course of this work show that the Xinjiang extrapolation chamber is suitable for calibration of high energy electron beams produced from medical linear accelerators.
文摘Today, dosimeters are used generally for dosimetry of the diagnostic X-ray beam. Ionization chambers are appropriate instruments for monitoring and also the dosimetry of X-ray beam in medical diagnostic equipment. The present work introduces design and investigation of a new ring-shaped monitor chamber with a PMMA body, graphite-coated PMMA windows (0.5 mm thick), a special graphite-foil central electrode (0.1 mm thick, 0.7 g/cm3 dense) that creating two sensitive volumes and a central hole for crossing the radiation beam with less attenuation. The results of performance tests conducted at the Nuclear Science and Technology Research Institute, AEOI in Karaj- Iran proved the high short and long-term stability, the very low leakage current, the low directional dependence and very high ion collection efficiency through the special design of the collecting electrode. Moreover, the FLUKA Monte Carlo simulations certified the negligible effect of central electrode on this new ring-shaped monitor chamber. According to the results of the performance tests, the new monitor chamber can be used as a standard dosimeter in order to monitor X-ray beam in primary standard dosimetry laboratories.
基金Supported by the National Nature Science Foundation of China (No. 10305015, No.10475098)the Major Program of the Chinese Academy of Science (No. O701050YZD)
文摘The clinical trials of tumor therapy using heavy ions beam 12C are now in progress at Institute of Modern Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy 12C beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy 12C beam in active pencil beam scanning mode.