期刊文献+
共找到118,766篇文章
< 1 2 250 >
每页显示 20 50 100
Uniformity Control of Scanned Beam in 300 MeV Proton and Heavy Ion Accelerator Complex at SESRI
1
作者 HOU Lingxiao YUAN Youjin +10 位作者 SHEN Guodong RUAN Shuang LIU Jie ZHU Yunpeng WANG Geng GUO Hongliang LYU Mingbang GAO Daqing XU Zhiguo SHENG Lina YANG Jiancheng 《原子能科学技术》 EI CAS CSCD 北大核心 2024年第4期705-713,共9页
In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiat... In recent years,heavy ion accelerator technology has been rapidly developing worldwide and widely applied in the fields of space radiation simulation and particle therapy.Usually,a very high uniformity in the irradiation area is required for the extracted ion beams,which is crucial because it directly affects the experimental precision and therapeutic effect.Specifically,ultra-large-area and high-uniformity scanning are crucial requirements for spacecraft radiation effects assessment and serve as core specification for beamline terminal design.In the 300 MeV proton and heavy ion accelerator complex at the Space Environment Simulation and Research Infrastructure(SESRI),proton and heavy ion beams will be accelerated and ultimately delivered to three irradiation terminals.In order to achieve the required large irradiation area of 320 mm×320 mm,horizontal and vertical scanning magnets are used in the extraction beam line.However,considering the various requirements for beam species and energies,the tracking accuracy of power supplies(PSs),the eddy current effect of scanning magnets,and the fluctuation of ion bunch structure will reduce the irradiation uniformity.To mitigate these effects,a beam uniformity optimization method based on the measured beam distribution was proposed and applied in the accelerator complex at SESRI.In the experiment,the uniformity is successfully optimized from 75%to over 90%after five iterations of adjustment to the PS waveforms.In this paper,the method and experimental results were introduced. 展开更多
关键词 heavy ion accelerator beam uniformity scanning magnet MIC
下载PDF
Acousto-optic scanning multi-photon lithography with high printing rate
2
作者 Minghui Hong 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第2期1-3,共3页
As a manufacturing method that is focused on end-users,3D printing has gained a lot of attention in recent years due to its unique advantages in fabricating complex three-dimensional structures.Various new micro-nano ... As a manufacturing method that is focused on end-users,3D printing has gained a lot of attention in recent years due to its unique advantages in fabricating complex three-dimensional structures.Various new micro-nano 3D printing methods have been developed to meet the demand for high-precision and high-yield manufacturing1-9.Among them,multi-photon-photon lithography(MPL) is a promising 3D nanofabrication technology due to its capability of true 3D digital processing and nanoscale processing resolution beyond the diffraction limit.It has been widely used to fabricate microoptics10,11,photonic crystals12,microfluidics13,meta-surfaces14,and mechanical metamaterials15. 展开更多
关键词 PHOTON Acous scanning
下载PDF
Investigation of reflection anisotropy induced by micropipe defects on the surface of a 4H-SiC single crystal using scanning anisotropy microscopy
3
作者 黄威 俞金玲 +7 位作者 刘雨 彭燕 王利军 梁平 陈堂胜 徐现刚 刘峰奇 陈涌海 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期630-637,共8页
Optical reflection anisotropy microscopy mappings of micropipe defects on the surface of a 4H-SiC single crystal are studied by the scanning anisotropy microscopy(SAM)system.The reflection anisotropy(RA)image with a&#... Optical reflection anisotropy microscopy mappings of micropipe defects on the surface of a 4H-SiC single crystal are studied by the scanning anisotropy microscopy(SAM)system.The reflection anisotropy(RA)image with a'butterfly pattern'is obtained around the micropipes by SAM.The RA image of the edge dislocations is theoretically simulated based on dislocation theory and the photoelastic principle.By comparing with the Raman spectrum,it is verified that the micropipes consist of edge dislocations.The different patterns of the RA images are due to the different orientations of the Burgers vectors.Besides,the strain distribution of the micropipes is also deduced.One can identify the dislocation type,the direction of the Burgers vector and the optical anisotropy from the RA image by using SAM.Therefore,SAM is an ideal tool to measure the optical anisotropy induced by the strain field around a defect. 展开更多
关键词 scanning anisotropy microscopy SiC reflection anisotropy edge dislocation
下载PDF
A review of understanding electrocatalytic reactions in energy conversion and energy storage systems via scanning electrochemical microscopy
4
作者 Jihye Park Jong Hwan Lim +4 位作者 Jin-Hyuk Kang Jiheon Lim Ho Won Jang Hosun Shin Sun Hwa Park 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第4期155-177,共23页
To address climate change and promote environmental sustainability,electrochemical energy conversion and storage systems emerge as promising alternative to fossil fuels,catering to the escalating demand for energy.Ach... To address climate change and promote environmental sustainability,electrochemical energy conversion and storage systems emerge as promising alternative to fossil fuels,catering to the escalating demand for energy.Achieving optimal energy efficiency and cost competitiveness in these systems requires the strategic design of electrocatalysts,coupled with a thorough comprehension of the underlying mechanisms and degradation behavior occurring during the electrocatalysis processes.Scanning electrochemical microscopy(SECM),an analytical technique for studying surface electrochemically,stands out as a powerful tool offering electrochemical insights.It possesses remarkable spatiotemporal resolution,enabling the visualization of the localized electrochemical activity and surface topography.This review compiles crucial research findings and recent breakthroughs in electrocatalytic processes utilizing the SECM methodology,specifically focusing on applications in electrolysis,fuel cells,and metal–oxygen batteries within the realm of energy conversion and storage systems.Commencing with an overview of each energy system,the review introduces the fundamental principles of SECM,and aiming to provide new perspectives and broadening the scope of applied research by describing the major research categories within SECM. 展开更多
关键词 scanning electrochemical microscopy ELECTROCATALYST ELECTROCATALYSIS Water splitting Fuel cell Metal-oxygen battery
下载PDF
Fatigue properties and damage constitutive model of salt rock based on CT scanning
5
作者 Junbao Wang Xiao Liu +3 位作者 Qiang Zhang Xinrong Liu Zhanping Song Shijin Feng 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第2期245-259,共15页
To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,an... To investigate the macroscopic fatigue properties and the mesoscopic pore evolution characteristics of salt rock under cyclic loading,fatigue tests under different upper-limit stresses were carried out on salt rock,and the mesoscopic pore structures of salt rock before and after fatigue tests and under different cycle numbers were measured using CT scanning instrument.Based on the test results,the effects of the cycle number and the upper-limit stress on the evolution of cracks,pore morphology,pore number,pore volume,pore size,plane porosity,and volume porosity of salt rock were analyzed.The failure path of salt rock specimens under cyclic loading was analyzed using the distribution law of plane porosity.The damage variable of salt rock under cyclic loading was defined on basis of the variation of volume porosity with cycle number.In order to describe the fatigue deformation behavior of salt rock under cyclic loading,the nonlinear Burgers damage constitutive model was further established.The results show that the model established can better reflect the whole development process of fatigue deformation of salt rock under cyclic loading. 展开更多
关键词 Salt rock Cyclic loading CT scanning Mesoscopic pore evolution Constitutive model
下载PDF
Algorithm of automatic identification of diabetic retinopathy foci based on ultra-widefield scanning laser ophthalmoscopy
6
作者 Jie Wang Su-Zhen Wang +7 位作者 Xiao-Lin Qin Meng Chen Heng-Ming Zhang Xin Liu Meng-Jun Xiang Jian-Bin Hu Hai-Yu Huang Chang-Jun Lan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期610-615,共6页
AIM:To propose an algorithm for automatic detection of diabetic retinopathy(DR)lesions based on ultra-widefield scanning laser ophthalmoscopy(SLO).METHODS:The algorithm utilized the FasterRCNN(Faster Regions with CNN ... AIM:To propose an algorithm for automatic detection of diabetic retinopathy(DR)lesions based on ultra-widefield scanning laser ophthalmoscopy(SLO).METHODS:The algorithm utilized the FasterRCNN(Faster Regions with CNN features)+ResNet50(Residua Network 50)+FPN(Feature Pyramid Networks)method for detecting hemorrhagic spots,cotton wool spots,exudates,and microaneurysms in DR ultra-widefield SLO.Subimage segmentation combined with a deeper residual network FasterRCNN+ResNet50 was employed for feature extraction to enhance intelligent learning rate.Feature fusion was carried out by the feature pyramid network FPN,which significantly improved lesion detection rates in SLO fundus images.RESULTS:By analyzing 1076 ultra-widefield SLO images provided by our hospital,with a resolution of 2600×2048 dpi,the accuracy rates for hemorrhagic spots,cotton wool spots,exudates,and microaneurysms were found to be 87.23%,83.57%,86.75%,and 54.94%,respectively.CONCLUSION:The proposed algorithm demonstrates intelligent detection of DR lesions in ultra-widefield SLO,providing significant advantages over traditional fundus color imaging intelligent diagnosis algorithms. 展开更多
关键词 diabetic retinopathy ultra-widefield scanning laser ophthalmoscopy intelligent diagnosis system
下载PDF
Optical scanning endoscope via a single multimode optical fiber
7
作者 Guangxing Wu Runze Zhu +2 位作者 Yanqing Lu Minghui Hong Fei Xu 《Opto-Electronic Science》 2024年第3期1-32,共32页
Optical endoscopy has become an essential diagnostic and therapeutic approach in modern biomedicine for directly observing organs and tissues deep inside the human body,enabling non-invasive,rapid diagnosis and treatm... Optical endoscopy has become an essential diagnostic and therapeutic approach in modern biomedicine for directly observing organs and tissues deep inside the human body,enabling non-invasive,rapid diagnosis and treatment.Optical fiber endoscopy is highly competitive among various endoscopic imaging techniques due to its high flexibility,compact structure,excellent resolution,and resistance to electromagnetic interference.Over the past decade,endoscopes based on a single multimode optical fiber(MMF)have attracted widespread research interest due to their potential to significantly reduce the footprint of optical fiber endoscopes and enhance imaging capabilities.In comparison with other imaging principles of MMF endoscopes,the scanning imaging method based on the wavefront shaping technique is highly developed and provides benefits including excellent imaging contrast,broad applicability to complex imaging scenarios,and good compatibility with various well-established scanning imaging modalities.In this review,various technical routes to achieve light focusing through MMF and procedures to conduct the scanning imaging of MMF endoscopes are introduced.The advancements in imaging performance enhancements,integrations of various imaging modalities with MMF scanning endoscopes,and applications are summarized.Challenges specific to this endoscopic imaging technology are analyzed,and potential remedies and avenues for future developments are discussed. 展开更多
关键词 multimode optical fiber ENDOSCOPE scanning imaging FOCUSING wavefront shaping
下载PDF
Three-dimensional finite element simulation and reconstruction of jointed rock models using CT scanning and photogrammetry
8
作者 Yingxian Lang Zhengzhao Liang Zhuo Dong 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第4期1348-1361,共14页
The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory e... The geometry of joints has a significant influence on the mechanical properties of rocks.To simplify the curved joint shapes in rocks,the joint shape is usually treated as straight lines or planes in most laboratory experiments and numerical simulations.In this study,the computerized tomography (CT) scanning and photogrammetry were employed to obtain the internal and surface joint structures of a limestone sample,respectively.To describe the joint geometry,the edge detection algorithms and a three-dimensional (3D) matrix mapping method were applied to reconstruct CT-based and photogrammetry-based jointed rock models.For comparison tests,the numerical uniaxial compression tests were conducted on an intact rock sample and a sample with a joint simplified to a plane using the parallel computing method.The results indicate that the mechanical characteristics and failure process of jointed rocks are significantly affected by the geometry of joints.The presence of joints reduces the uniaxial compressive strength (UCS),elastic modulus,and released acoustic emission (AE) energy of rocks by 37%–67%,21%–24%,and 52%–90%,respectively.Compared to the simplified joint sample,the proposed photogrammetry-based numerical model makes the most of the limited geometry information of joints.The UCS,accumulative released AE energy,and elastic modulus of the photogrammetry-based sample were found to be very close to those of the CT-based sample.The UCS value of the simplified joint sample (i.e.38.5 MPa) is much lower than that of the CT-based sample (i.e.72.3 MPa).Additionally,the accumulative released AE energy observed in the simplified joint sample is 3.899 times lower than that observed in the CT-based sample.CT scanning provides a reliable means to visualize the joints in rocks,which can be used to verify the reliability of photogrammetry techniques.The application of the photogrammetry-based sample enables detailed analysis for estimating the mechanical properties of jointed rocks. 展开更多
关键词 X-ray computerized tomography(CT)scanning PHOTOGRAMMETRY Parallel computing Numerical simulation Uniaxial compression test Digital image processing
下载PDF
In situ observation of the dissolution kinetics of Al_(2)O_(3) particles in CaO–Al_(2)O_(3)–SiO_(2) slags using laser confocal scanning microscopy 被引量:1
9
作者 Changyu Ren Caide Huang +1 位作者 Lifeng Zhang Ying Ren 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2023年第2期345-353,共9页
The dissolution kinetics of Al_(2)O_(3) in CaO-Al_(2)O_(3) SiOslags was studied using a high-temperature confocal scanning laser microscope at 1773 to 1873 K.The results show that the controlling step during the Al_(2... The dissolution kinetics of Al_(2)O_(3) in CaO-Al_(2)O_(3) SiOslags was studied using a high-temperature confocal scanning laser microscope at 1773 to 1873 K.The results show that the controlling step during the Al_(2)O_(3) dissolution was the diffusionin molten slag.It was found that the dissolution curves of Al_(2)O_(3) particles were hardly agreed with the traditional boundary layer diffusion model with the increase of the CaO/Al_(2)O_(3) ratio of slag.A modified diffusion equation considering slag viscosity was developed to study the dissolution mechanism of Al_(2)O_(3) in slag.Diffusion coefficients of Al_(2)O_(3) in slag were calculated as 2.8×10to 4.1×10m~2/s at the temperature of 1773-1873 K.The dissolution rate of Al_(2)O_(3) increased with higher temperature,CaO/Al_(2)O_(3),and particle size.A new model was shown to be v_(Al_(2)O_(3))=0.16×r_(0)^(1.58)×x^(3.52)×(T-T_(mp))^(1.11)to predict the dissolution rate and the total dissolution time of Al_(2)O_(3) inclusions with various sizes,where vAl_(2)O_(3) is the dissolution rate of Al_(2)O_(3) in volume,μm^(3)/s;x is the value of CaO/Al_(2)O_(3) mass ratio;R_(0) is the initial radius of Al_(2)O_(3),μm;T is the temperature,K;T_(mp) is the melting point of slag,K. 展开更多
关键词 INCLUSION dissolution kinetics confocal scanning laser microscope refining slag
下载PDF
Collection efficiency of a monitor parallel plate ionization chamber for pencil beam scanning proton therapy 被引量:5
10
作者 Rong-Cheng Han Yong-Jiang Li Yue-Hu Pu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第2期1-10,共10页
The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or p... The collection efficiency of monitor parallel plate ionization chambers is the main uncertainty in the beam control of pencil beam scanning systems.Existing calculation methods for collection efficiency in photon or passive scattering proton systems have not considered the characteristics of non-uniform charge density in pencil beam scanning systems.In this study,Boag’s theory was applied to a proton pencil beam scanning system.The transverse distribution of charge density in the ionization chamber was considered to be a Gaussian function and an analytical solution was derived to calculate collection efficiency in the beam spot area.This calculation method is called the integral method and it was used to investigate the effects of beam parameters on collection efficiency.It was determined that collection efficiency is positively correlated with applied voltage,beam size,and beam energy,but negatively correlated with beam current intensity.Additionally,it was confirmed that collection efficiency is improved when the air filling the monitor parallel plate ionization chamber is replaced with nitrogen. 展开更多
关键词 Collection efficiency Monitor ionization chamber Pencil beam scanning Proton therapy
下载PDF
Precise magnetic field control of the scanning magnets for the APTRON beam delivery system 被引量:7
11
作者 Chun-Hui Miao Ming Liu +1 位作者 Chong-Xian Yin Zhen-Tang Zhao 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第12期193-197,共5页
A design for precise scanning magnetic field control for the beam delivery system of the Shanghai Advanced Proton Therapy Facility(APTRON) is presented in this paper. With a novel feedforward algorithm to compensate f... A design for precise scanning magnetic field control for the beam delivery system of the Shanghai Advanced Proton Therapy Facility(APTRON) is presented in this paper. With a novel feedforward algorithm to compensate for magnet hysteresis, the scanning magnetic field can be controlled to within a precision of ± 2.5 G.The main advantage of the proposed feedforward algorithm is that the average settling time is shorter compared with that of a conventional feedback algorithm with acceptable tolerance. 展开更多
关键词 PROTON therapy scanning MAGNET HYSTERESIS FEEDFORWARD control
下载PDF
Equalization of Ti 6Al 4V alloy welded joint by scanning electron beam welding 被引量:2
12
作者 Chen Xiaofeng(陈晓风) Han Zhong(韩忠) +2 位作者 Lou Xinfang(楼新芳) Hu Chuanshun(胡传顺) Sun Changyi(孙长义) 《中国有色金属学会会刊:英文版》 EI CSCD 1999年第3期535-540,共6页
The equalization of Ti 6Al 4V alloy welded joint with base metal on corrosion resistance, strength and ductility was studied. The solidification microstructure is transformed from 650 μm columnar grains to 100 μm eq... The equalization of Ti 6Al 4V alloy welded joint with base metal on corrosion resistance, strength and ductility was studied. The solidification microstructure is transformed from 650 μm columnar grains to 100 μm equiaxed grains by scanning electron beam welding. The anodic polarization curve of 150 μm equiaxed grains coincides with that of base metal. Equal corrosion resistance between weld metal and base metal was obtained. Uniform microstructure and solute distribution are the basis of equalization. Corrosion rate of weld with 150 μm equiaxed grains is the lowest, 2.45 times lower than that of 650 μm columnar grains. Weld strength is 98% as much as that of base metal, yield strength ratio is 99.5%, which is 3.6% higher than that of base metal. 展开更多
关键词 scanning electron beam WELDING TITANIUM ALLOY WELDING equalizationDocument code: A
下载PDF
New clinical application of digital intraoral scanning technology in occlusal reconstruction:A case report
13
作者 Chao Hou Hua-Zhang Zhu +4 位作者 Bai Xue Hong-Jie Song Ying-Bei Yang Xiao-Xue Wang Hui-Qiang Sun 《World Journal of Clinical Cases》 SCIE 2023年第15期3522-3532,共11页
BACKGROUND Digital intraoral scanning,although developing rapidly,is rarely used in occlusal reconstruction.To compensate for the technical drawbacks of current occlusal reconstruction techniques,such as time consumpt... BACKGROUND Digital intraoral scanning,although developing rapidly,is rarely used in occlusal reconstruction.To compensate for the technical drawbacks of current occlusal reconstruction techniques,such as time consumption and high technical requirements,digital intraoral scanning can be used in clinics.This report aims to provide a way of selecting the most suitable maxillo-mandibular relationship(MMR)during recovery.CASE SUMMARY A 68-year-old man with severely worn posterior teeth underwent occlusal reconstruction with fixed prosthesis using digital intraoral scanning.A series of digital models in different stages of treatment were obtained,subsequently compared,and selected using digital intraoral scanning together with traditional measurements,such as cone beam computed tomography,joint imaging,and clinical examination.Using digital intraoral scanning,the MMR in different stages of treatment was accurately recorded,which provided feasibility for deciding the best occlusal reconstruction treatment,made the treatment process easier,and improved patient satisfaction.CONCLUSION This case report highlights the clarity,recordability,repeatability,and selectivity of digital intraoral scanning to replicate and transfer the MMR during occlusal reconstruction,expanding new perspectives for its design,fabrication,and postoperative evaluation. 展开更多
关键词 Occlusal reconstruction Digital intraoral scanning Maxillo-mandibular relationship Cone beam computed tomography Case report
下载PDF
Reformatted method for two-dimensional detector arrays measurement data in proton pencil beam scanning 被引量:2
14
作者 Meng-Ya Guo Xiu-Fang Li +6 位作者 Jie Wang Qi Liu Xiu-Zhen Deng Man-Zhou Zhang Li-Ren Shen Yue-Hu Pu Zhi-Ling Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第6期83-93,共11页
The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with are... The spatial resolution of a commercial two-dimensional(2D)ionization chamber(IC)array is limited by the size of the individual detector and the center-to-center distance between sensors.For dose distributions with areas of steep dose gradients,inter-detector dose values are derived by the interpolation of nearby detector readings in the conventional mathematical interpolation of 2D IC array measurements.This may introduce significant errors,particularly in proton spot scanning radiotherapy.In this study,by combining logfile-based reconstructed dose values and detector measurements with the Laplacian pyramid image blending method,a novel method is proposed to obtain a reformatted dose distribution that provides an improved estimation of the delivered dose distribution with high spatial resolution.Meanwhile,the similarity between the measured original data and the downsampled logfilebased reconstructed dose is regarded as the confidence of the reformatted dose distribution.Furthermore,we quantify the performance benefits of this new approach by directly comparing the reformatted dose distributions with 2D IC array detector mathematically interpolated measurements and original low-resolution measurements.The result shows that this new method is better than the mathematical interpolation and achieves gamma pass rates similar to those of the original low-resolution measurements.The reformatted dose distributions generally yield a confidence exceeding 95%. 展开更多
关键词 2D ion chamber array detectors Laplacian pyramid image blending High-resolution reformatted methods Pencil beam scanning Proton therapy
下载PDF
Control on Electron Beam Scanning Track 被引量:3
15
作者 王学东 姚舜 《Journal of Shanghai Jiaotong university(Science)》 EI 2004年第3期1-5,共5页
In order to use electron beam as a movable welding heat source and whose energy distribution along its moving trace can be controlled, a method of electron beam scanning track and scanning mode control was put forward... In order to use electron beam as a movable welding heat source and whose energy distribution along its moving trace can be controlled, a method of electron beam scanning track and scanning mode control was put forward. Based on it, the electron beam scanning track and scanning mode can be edited at will according to actual requirements, and the energy input of each point of the scanning track can be controlled. In addition, the scanning frequency and points control, real time adjusting of the scanning track etc. were explained. This method can be used in electron beam brazing, surface modification, surface heat treatment etc. 展开更多
关键词 电子束 扫描方向 控制模型 活动焊接 EBW
下载PDF
The scanning tunneling microscopy and spectroscopy of GaSb_(1-x)Bi_(x) films of a few-nanometer thickness grown by molecular beam epitaxy 被引量:1
16
作者 Fangxing Zha Qiuying Zhang +4 位作者 Haoguang Dai Xiaolei Zhang Li Yue Shumin Wang Jun Shao 《Journal of Semiconductors》 EI CAS CSCD 2021年第9期42-46,共5页
The ultrahigh vacuum scanning tunneling microscope(STM)was used to characterize the GaSb_(1-x)Bi_(x) films of a few nanometers thickness grown by the molecular beam epitaxy(MBE)on the GaSb buffer layer of 100 nm with ... The ultrahigh vacuum scanning tunneling microscope(STM)was used to characterize the GaSb_(1-x)Bi_(x) films of a few nanometers thickness grown by the molecular beam epitaxy(MBE)on the GaSb buffer layer of 100 nm with the GaSb(100)substrates.The thickness of the GaSb_(1-x)Bi_(x) layers of the samples are 5 and 10 nm,respectively.For comparison,the GaSb buffer was also characterized and its STM image displays terraces whose surfaces are basically atomically flat and their roughness is generally less than 1 monolayer(ML).The surface of 5 nm GaSb_(1-x)Bi_(x) film reserves the same terraced morphology as the buffer layer.In contrast,the morphology of the 10 nm GaSb_(1-x)Bi_(x) film changes to the mound-like island structures with a height of a few MLs.The result implies the growth mode transition from the two-dimensional mode as displayed by the 5 nm film to the Stranski-Krastinov mode as displayed by the 10 nm film.The statistical analysis with the scanning tunneling spectroscopy(STS)measurements indicates that both the incorporation and the inhomogeneity of Bi atoms increase with the thickness of the GaSb_(1-x)Bi_(x) layer. 展开更多
关键词 scanning tunneling microscopy molecular beam epitaxy semiconductor surface
下载PDF
Application of Scanning Acoustic Microscopy for Detection of Dental Caries Lesion
17
作者 Yukihiro Naganuma Kouki Hatori +7 位作者 Masahiro Iikubo Masatoshi Takahashi Yoshihiro Hagiwara Kazuto Kobayashi Atsushi Takahashi Kumi Hoshi Yoshifumi Saijo Keiichi Sasaki 《Open Journal of Stomatology》 2023年第1期12-24,共13页
Introduction: A scanning acoustic microscope (SAM) is an apparatus for imaging acoustic properties. This apparatus can non-invasively and rapidly evaluate the hardness of materials in the elastic region. This device s... Introduction: A scanning acoustic microscope (SAM) is an apparatus for imaging acoustic properties. This apparatus can non-invasively and rapidly evaluate the hardness of materials in the elastic region. This device shows great potential for the diagnosis of dental caries in the clinical setting. However, since the tissue elastic modulus measured using a SAM is a property of the elastic region and the Knoop hardness is a property of the plastic region, the hardness properties differ completely. Therefore, we investigated whether the acoustic impedance measured using a SAM is related to the Knoop hardness, which is used as the standard for removal of carious dentin. Method: Polished sections were prepared from 20 extracted carious wisdom teeth. The acoustic impedance and Knoop hardness were measured for each section. In addition to comparing carious and healthy dentin in SAM images, we evaluated the difference between the carious and healthy dentin in terms of the acoustic impedance and Knoop hardness. We also evaluated the correlation between the Knoop hardness and acoustic impedance. Results: The SAM images were visualized as two-dimensional color images based on the acoustic impedance values. The mean acoustic impedance of carious dentin was significantly lower than that of healthy dentin, showing a similar trend as Knoop hardness. A strong correlation was observed between the two. Discussion: The acoustic impedance values obtained through acoustic microscopy differed significantly between carious and sound dentin. Both types of dentins were visualized using two-dimensional color images. A strong correlation was observed between the acoustic impedance value, which indicates the hardness of the elastic region, and the Knoop hardness, which indicates the hardness of the plastic region. The results of the present study indicate that acoustic impedance accurately reflects the hardness of dentin. 展开更多
关键词 scanning Acoustic Microscope Acoustic Impedance CARIES Knoop Hardness
下载PDF
Thermoacoustic imaging:From single-element scanning to portable and array-based imaging
18
作者 Yi-Jie Huang Qi-Kai-Yu Feng Lin Huang 《Journal of Electronic Science and Technology》 EI CAS CSCD 2023年第3期1-20,共20页
The microwave-induced thermoacoustic imaging(TAI)technology has both the advantages of high contrast of microwave imaging and high resolution of ultrasound imaging(UI),so it has carried out exploratory application res... The microwave-induced thermoacoustic imaging(TAI)technology has both the advantages of high contrast of microwave imaging and high resolution of ultrasound imaging(UI),so it has carried out exploratory application research in various areas,such as the early detection of breast tumors and cerebrovascular diseases.However,the microwave generator used in the traditional TAI technology is huge and expensive,and the temporal resolution is also too low due to the single-element scanning mechanism.Thus,it is difficult to meet the needs of clinical applications.In this paper,the iterative process and the analysis of related application scenarios from single-element scanning to portable and array-based TAI,such as the miniaturized microwave generator,handheld antenna,multi-channel data acquisition,and UI/TAIdual-modality imaging,are reviewed,and the future trends of this technology are discussed.This review helps researchers in the field of TAI learn the technological development process and future trends.It also deepens clinicians’understanding of TAI so as to put forward more application requirements. 展开更多
关键词 Array-based PORTABLE Single-element scanning Thermoacoustic imaging(TAI)
下载PDF
Study on the LAI Single Tree Model Based on Terrestrial Laser Scanning
19
作者 Zhaohua Pan Genshen Fu 《Open Journal of Geology》 CAS 2023年第5期431-448,共18页
Leaf area index (LAI) is a key parameter for studying global terrestrial ecology and environment and has great ecological significance. How to accurately measure and calculate structural parameters of trees has become... Leaf area index (LAI) is a key parameter for studying global terrestrial ecology and environment and has great ecological significance. How to accurately measure and calculate structural parameters of trees has become an urgent matter. This paper reports the use of terrestrial laser scanning (TLS) as a measurement tool to achieve accurate LAI estimation through point cloud preprocessing measures, the LeWos algorithm, and voxel methods. The accuracy and feasibility of this indirect measurement method were explored. It is found that the single wood structure parameters extracted from TLS have a good linear relationship with manual measurement, and the extraction errors meet the requirements of real-scene conversion. The study also found when the voxel size is consistent with the minimum distance of the point cloud set by TLS instrument, it has a strong correlation with the measured value of canopy analyser. These results lay the foundation for conveniently and quickly obtaining structural parameters of trees, tree growth state detection, and canopy ecological benefit assessment. 展开更多
关键词 Leaf Area Index Terrestrial Laser scanning Branch-Leaf Separation Point Cloud Voxelization
下载PDF
Acousto-optic scanning spatial-switching multiphoton lithography
20
作者 Binzhang Jiao Fayu Chen +6 位作者 Yuncheng Liu Xuhao Fan Shaoqun Zeng Qi Dong Leimin Deng Hui Gao Wei Xiong 《International Journal of Extreme Manufacturing》 SCIE EI CAS CSCD 2023年第3期597-606,共10页
Nano-3D printing has obtained widespread attention owing to its capacity to manufacture end-use components with nano-scale features in recent years.Multiphoton lithography(MPL)is one of the most promising 3D nanomanuf... Nano-3D printing has obtained widespread attention owing to its capacity to manufacture end-use components with nano-scale features in recent years.Multiphoton lithography(MPL)is one of the most promising 3D nanomanufacturing technologies,which has been widely used in manufacturing micro-optics,photonic crystals,microfluidics,meta-surface,and mechanical metamaterials.Despite of tremendous potential of MPL in laboratorial and industrial applications,simultaneous achievement of high throughput,high accuracy,high design freedom,and a broad range of material structuring capabilities remains a long-pending challenge.To address the issue,we propose an acousto-optic scanning with spatial-switching multispots(AOSS)method.Inertia-free acousto-optic scanning and nonlinear swept techniques have been developed for achieving ultrahigh-speed and aberration-free scanning.Moreover,a spatial optical switch concept has been implemented to significantly boost the lithography throughput while maintaining high resolution and high design freedom.An eight-foci AOSS system has demonstrated a record-high 3D printing rate of 7.6×10^(7)voxel s^(-1),which is nearly one order of magnitude higher than earlier scanning MPL,exhibiting its promise for future scalable 3D nanomanufacturing. 展开更多
关键词 3D nano-printing acousto-optic scanning aberration-free wavefront spatial-switching
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部